Wenyuan Hao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenyuan Hao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Hao Guo
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China, Taiyuan, China
10 shared publications - Huan Fei Wen
North University of China
10 shared publications - Jun Tang
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China, Taiyuan, China
10 shared publications - Zhonghao Li
State Key Laboratory of Widegap Semiconductor Optoelectronic Materials and Technologies, North University of China, Taiyuan 030051, China
10 shared publications - Zongmin Ma
North University of China
10 shared publications - Jun Liu
North University of China
9 shared publications
Latest Publications
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Noninvasive Microwave Distribution Imaging With High-Frequency Resolution Using NV Centers in Diamond
The characterization of microwave fields holds significant engineering importance in high-frequency chip design and performance optimization. In this study, we propose a non-invasive wide-field imaging method based on the spectral hole-burning effect in optically detected magnetic resonance (ODMR). This wide-field imaging method enables imaging of microwave fields at different frequencies under near-field radiator operating conditions. Its feasibility is confirmed by characterizing near-field radiator-generated microwave fields across multiple frequency and power settings. Furthermore, the effectiveness of the method is validated through a comparative analysis of simulation results and experimental measurements. Under the current experimental conditions, the results show that the approach achieves a frequency resolution of 100 kHz over the range of the resonance region, a microwave detection sensitivity of 0.78 nT/Hz1/2, a spatial imaging resolution of 1.55 μm, and the minimum detectable power is 1 mW. The above methods indicate great potential for application in the fields of integrated circuit fault diagnosis, electromagnetic compatibility testing, and radio equipment parameter calibration.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Noninvasive Microwave Distribution Imaging With High-Frequency Resolution Using NV Centers in Diamond
The characterization of microwave fields holds significant engineering importance in high-frequency chip design and performance optimization. In this study, we propose a non-invasive wide-field imaging method based on the spectral hole-burning effect in optically detected magnetic resonance (ODMR). This wide-field imaging method enables imaging of microwave fields at different frequencies under near-field radiator operating conditions. Its feasibility is confirmed by characterizing near-field radiator-generated microwave fields across multiple frequency and power settings. Furthermore, the effectiveness of the method is validated through a comparative analysis of simulation results and experimental measurements. Under the current experimental conditions, the results show that the approach achieves a frequency resolution of 100 kHz over the range of the resonance region, a microwave detection sensitivity of 0.78 nT/Hz1/2, a spatial imaging resolution of 1.55 μm, and the minimum detectable power is 1 mW. The above methods indicate great potential for application in the fields of integrated circuit fault diagnosis, electromagnetic compatibility testing, and radio equipment parameter calibration.
- 25 June 2025
- Published by Wiley in Advanced Quantum Technologies
- Vol. 8 (10)
Optical Detection of Multi‐Channel Digital Signals Using Nitrogen‐Vacancy Centers Array
The efficient detection of digital signals plays a vital role in optimizing the reliability and stability of communication systems. This paper demonstrates a method to optically measure digital signals based on solid‐state quantum spin. The digital signals are non‐intrusively characterized by taking advantage of the optical readability of the spin states of the nitrogen‐vacancy (NV) centers array. Meanwhile, the resonance frequencies of optically detected magnetic resonance (ODMR) spectra are spatially encoded by means of an external magnetic field gradient, thereby realizing the simultaneous acquisition of three‐channel digital signals. Over a continuous detection bandwidth of 258 MHz, digital signals can be detected with a time resolution of 3 ms and a minimum signal strength of 0 dBm. Afterward, the ability of this system to capture digital signals is further substantiated by measuring signals in other channels. This proposal is competent for the simultaneous analysis of multi‐channel signals in real‐time and provides a valuable reference for radio spectrum monitoring, and signal intelligence reconnaissance.
- 25 June 2025
- Published by Wiley in Advanced Quantum Technologies
- Vol. 8 (10)
Optical Detection of Multi‐Channel Digital Signals Using Nitrogen‐Vacancy Centers Array
The efficient detection of digital signals plays a vital role in optimizing the reliability and stability of communication systems. This paper demonstrates a method to optically measure digital signals based on solid‐state quantum spin. The digital signals are non‐intrusively characterized by taking advantage of the optical readability of the spin states of the nitrogen‐vacancy (NV) centers array. Meanwhile, the resonance frequencies of optically detected magnetic resonance (ODMR) spectra are spatially encoded by means of an external magnetic field gradient, thereby realizing the simultaneous acquisition of three‐channel digital signals. Over a continuous detection bandwidth of 258 MHz, digital signals can be detected with a time resolution of 3 ms and a minimum signal strength of 0 dBm. Afterward, the ability of this system to capture digital signals is further substantiated by measuring signals in other channels. This proposal is competent for the simultaneous analysis of multi‐channel signals in real‐time and provides a valuable reference for radio spectrum monitoring, and signal intelligence reconnaissance.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Circuit Subsurface Characterization Based on Magnetic Gradient Tensor Quantum Imaging
With the advancement in electronic device integration, multilayer circuits are now capable of arranging high-capacity wiring within limited spaces, which make them extensively applicable in the electronics industry. It is essential to perform inspections on subsurface circuits to guarantee advancements in manufacturing processes and designs. This article presents a method for magnetic gradient tensor imaging of multilayer circuits under operational conditions, utilizing a quantum wide-field microscope based on nitrogen-vacancy (NV) centers in diamond. Compared to vector magnetic field imaging and scalar magnetic field imaging, the magnetic gradient tensor imaging method exhibits superior boundary recognition capabilities and can effectively mitigate blurring issues arising from magnetic field superposition and divergence, thereby enabling the acquisition of more precise circuit structure details. By packaging the vector magnetic field pixel matrix and performing continuous differential operations on adjacent pixels, the calculation of magnetic gradient tensor imaging was successfully achieved. In this article, a dual-layer circuit with a current of 2 and 0.1 A was tested, with an interlayer spacing of $200~\mu $ m. The highest recognition accuracy for magnetic gradient tensor imaging reached 98.2%. This quantum imaging-based method successfully achieved the noninvasive detection of subsurface defects in multilayer circuits under working conditions, which have great potential in the areas of electromagnetic compatibility testing and electronic device characterization.
- 14 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Circuit Subsurface Characterization Based on Magnetic Gradient Tensor Quantum Imaging
With the advancement in electronic device integration, multilayer circuits are now capable of arranging high-capacity wiring within limited spaces, which make them extensively applicable in the electronics industry. It is essential to perform inspections on subsurface circuits to guarantee advancements in manufacturing processes and designs. This article presents a method for magnetic gradient tensor imaging of multilayer circuits under operational conditions, utilizing a quantum wide-field microscope based on nitrogen-vacancy (NV) centers in diamond. Compared to vector magnetic field imaging and scalar magnetic field imaging, the magnetic gradient tensor imaging method exhibits superior boundary recognition capabilities and can effectively mitigate blurring issues arising from magnetic field superposition and divergence, thereby enabling the acquisition of more precise circuit structure details. By packaging the vector magnetic field pixel matrix and performing continuous differential operations on adjacent pixels, the calculation of magnetic gradient tensor imaging was successfully achieved. In this article, a dual-layer circuit with a current of 2 and 0.1 A was tested, with an interlayer spacing of $200~\mu $ m. The highest recognition accuracy for magnetic gradient tensor imaging reached 98.2%. This quantum imaging-based method successfully achieved the noninvasive detection of subsurface defects in multilayer circuits under working conditions, which have great potential in the areas of electromagnetic compatibility testing and electronic device characterization.
- 29 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Portable Magnetic Camera Using NV Centers
Nitrogen-vacancy (NV) centers in diamond have become a powerful tool for wide-field magnetic field imaging. However, conventional magnetic field imaging system based on NV centers relies on experimental platforms and is not mobile, resulting in limited working scenarios. In this paper, we have designed a portable magnetic camera (PMC, volume: 3.7 dm 3 ) using NV centers and demonstrated its imaging of vector magnetic field at the bent portion of integrated circuit board wiring (width: 200 μm). Reduces footprint by more than 90% compared to magnetic imaging platforms built on top of optical platforms. In addition, a corresponding control box (volume: 6.7 dm 3 ) was designed to integrate the large equipment required for the experiment inside to improve portability. The PMC integrates the optical module and the data acquisition module. The control box integrates a microwave board to provide microwave signals to the PMC to control the NV centers quantum states, and integrates a data acquisition module to collect data. Our study shows that the experimental results are very similar to the theoretical simulation of the electromagnetic field (maximum error: 8%). The magnetic sensitivity of the PMC is about 1.825 μT/Hz 1/2 with a spatial resolution of 2.5 μm and a temporal resolution of 5.5 ms. The device can be used immediately in industrial applications where precise magnetic field imaging is required, providing a new direction in the practical application of NV centers magnetic field imaging system.
- 29 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Portable Magnetic Camera Using NV Centers
Nitrogen-vacancy (NV) centers in diamond have become a powerful tool for wide-field magnetic field imaging. However, conventional magnetic field imaging system based on NV centers relies on experimental platforms and is not mobile, resulting in limited working scenarios. In this paper, we have designed a portable magnetic camera (PMC, volume: 3.7 dm 3 ) using NV centers and demonstrated its imaging of vector magnetic field at the bent portion of integrated circuit board wiring (width: 200 μm). Reduces footprint by more than 90% compared to magnetic imaging platforms built on top of optical platforms. In addition, a corresponding control box (volume: 6.7 dm 3 ) was designed to integrate the large equipment required for the experiment inside to improve portability. The PMC integrates the optical module and the data acquisition module. The control box integrates a microwave board to provide microwave signals to the PMC to control the NV centers quantum states, and integrates a data acquisition module to collect data. Our study shows that the experimental results are very similar to the theoretical simulation of the electromagnetic field (maximum error: 8%). The magnetic sensitivity of the PMC is about 1.825 μT/Hz 1/2 with a spatial resolution of 2.5 μm and a temporal resolution of 5.5 ms. The device can be used immediately in industrial applications where precise magnetic field imaging is required, providing a new direction in the practical application of NV centers magnetic field imaging system.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Traversal Window Inversion of 3-D Boundary of Micro Magnetic Target Based on Quantum Imaging Technique
The 3-D boundary identification of magnetic targets is of significant importance for the magnetic characteristics assessment of magnetic devices. A high-fidelity reconstruction method for the 3-D boundary of tiny-sized magnetic targets through inversion techniques is presented in this article. Based on nitrogen-vacancy (NV) color centers in diamond, vector magnetic imaging with high sensitivity, wide field of view, and alignment-free is realized. Based on the anomaly distribution of the total magnetic field intensity (TMI), we determined the spatial dimensions and depth for the inversion and discretized the 3-D space into a grid. In order to overcome magnetic field noise and overlapping interference, we proposed a multiwindow inversion model by constructing inversion windows of various sizes. The application of various window sizes for inversion, along with the utilization of their corresponding gradient weights in a weighted combination, effectively addresses the ill-conditioned inversion challenges stemming from the nonlinear crosstalk of magnetic field noise. The experimental results show that the proposed method can achieve an inversion accuracy of 99.1% with a sensitivity of$2~\mu $ T/$\surd $ Hz. Compared with the method of L0–L2 norm regularization inversion, the inversion accuracy is improved by 3.5%. This method opens up a way for high-fidelity 3-D magnetic target boundary inversion.- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Traversal Window Inversion of 3-D Boundary of Micro Magnetic Target Based on Quantum Imaging Technique
The 3-D boundary identification of magnetic targets is of significant importance for the magnetic characteristics assessment of magnetic devices. A high-fidelity reconstruction method for the 3-D boundary of tiny-sized magnetic targets through inversion techniques is presented in this article. Based on nitrogen-vacancy (NV) color centers in diamond, vector magnetic imaging with high sensitivity, wide field of view, and alignment-free is realized. Based on the anomaly distribution of the total magnetic field intensity (TMI), we determined the spatial dimensions and depth for the inversion and discretized the 3-D space into a grid. In order to overcome magnetic field noise and overlapping interference, we proposed a multiwindow inversion model by constructing inversion windows of various sizes. The application of various window sizes for inversion, along with the utilization of their corresponding gradient weights in a weighted combination, effectively addresses the ill-conditioned inversion challenges stemming from the nonlinear crosstalk of magnetic field noise. The experimental results show that the proposed method can achieve an inversion accuracy of 99.1% with a sensitivity of$2~\mu $ T/$\surd $ Hz. Compared with the method of L0–L2 norm regularization inversion, the inversion accuracy is improved by 3.5%. This method opens up a way for high-fidelity 3-D magnetic target boundary inversion.- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Three-Dimensional Inverse Reconstruction of Tiny Magnetic Structures by Quantum Technique
Non-destructive measurement of tiny magnetic structures widely found in precision instruments has been a challenging work. Nitrogen vacancy (NV) is a solid-state quantum sensor that enables fast vector magnetic imaging by optical detection. However, NV magnetic detection results lack information about magnetic anomalies in the perpendicular direction, while the dispersive magnetic field blurs the features of the magnetic source. In this paper, we combine optical detection NV magnetic imaging with regularized inversion techniques, and propose a dual-observation-plane detection inversion method. We study the relationship between spatial magnetization intensity and observed magnetic induction intensity, and realizes three-dimensional inversion reconstruction of miniature magnetic structures. For the validation experiments, we chose to perform three-dimensional inverse reconstruction and quantitative analysis of the magnetic structures that break in the middle, which is difficult to detect by traditional methods. The inversion results achieve a spatial resolution of 40 μm in all three directions and a model accuracy of 94.4% at 20 iterations, providing a new solution for magnetic structure detection.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Three-Dimensional Inverse Reconstruction of Tiny Magnetic Structures by Quantum Technique
Non-destructive measurement of tiny magnetic structures widely found in precision instruments has been a challenging work. Nitrogen vacancy (NV) is a solid-state quantum sensor that enables fast vector magnetic imaging by optical detection. However, NV magnetic detection results lack information about magnetic anomalies in the perpendicular direction, while the dispersive magnetic field blurs the features of the magnetic source. In this paper, we combine optical detection NV magnetic imaging with regularized inversion techniques, and propose a dual-observation-plane detection inversion method. We study the relationship between spatial magnetization intensity and observed magnetic induction intensity, and realizes three-dimensional inversion reconstruction of miniature magnetic structures. For the validation experiments, we chose to perform three-dimensional inverse reconstruction and quantitative analysis of the magnetic structures that break in the middle, which is difficult to detect by traditional methods. The inversion results achieve a spatial resolution of 40 μm in all three directions and a model accuracy of 94.4% at 20 iterations, providing a new solution for magnetic structure detection.
- 12 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Three-Dimensional Motion Tracking of High-Speed Magnetic Targets Using Microwave-Free Quantum Imaging Technology
The rapid tracking of magnetic target holds significant importance in biomedicine, precision instrumentation, materials science, and more. The diamond nitrogen vacancy$({NV}^{-})$ color centers exhibit magnetic field detection effect. They have shown high sensitivity, calibration-free nature, easy readout, and operability at room temperature. This article presents an approach to rapidly induce magnetic fields based on the${NV}^{-}$ color centers ensemble without microwave. We demonstrated the magnetic-field-dependent photoluminescence (PL) of the${NV}^{-}$ color centers ensemble quantum system and applied it wide-field imaging. By expanding the magnetic dipole model, we achieved rapid 3-D tracking imaging technology of micro-sized magnetic target. Results show the${NV}^{-}$ color centers ensemble’s high dynamic sensing capabilities for magnetic fields, providing a wide field of view ($3000\times3000\,\,\mu \text{m}$ ) with a time resolution of 5 ms and a magnetic detection sensitivity of$0.5~\mu \text{T}/\surd $ Hz. Furthermore, it eliminated the influence of microwaves and reduced the experimental equipment requirements. These findings offer a direction for rapid tracking the magnetic target based on${NV}^{-}$ color centers ensemble.- 12 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Three-Dimensional Motion Tracking of High-Speed Magnetic Targets Using Microwave-Free Quantum Imaging Technology
The rapid tracking of magnetic target holds significant importance in biomedicine, precision instrumentation, materials science, and more. The diamond nitrogen vacancy$({NV}^{-})$ color centers exhibit magnetic field detection effect. They have shown high sensitivity, calibration-free nature, easy readout, and operability at room temperature. This article presents an approach to rapidly induce magnetic fields based on the${NV}^{-}$ color centers ensemble without microwave. We demonstrated the magnetic-field-dependent photoluminescence (PL) of the${NV}^{-}$ color centers ensemble quantum system and applied it wide-field imaging. By expanding the magnetic dipole model, we achieved rapid 3-D tracking imaging technology of micro-sized magnetic target. Results show the${NV}^{-}$ color centers ensemble’s high dynamic sensing capabilities for magnetic fields, providing a wide field of view ($3000\times3000\,\,\mu \text{m}$ ) with a time resolution of 5 ms and a magnetic detection sensitivity of$0.5~\mu \text{T}/\surd $ Hz. Furthermore, it eliminated the influence of microwaves and reduced the experimental equipment requirements. These findings offer a direction for rapid tracking the magnetic target based on${NV}^{-}$ color centers ensemble.- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (6) , 3514-3521
High-Dynamic-Range Detection of Microwave Signal on Chip Surface Based on Diamond Sensors
This article proposed a microwave (MW) detection method by utilizing the effect of the dual MW on nitrogen-vacancy (NV) centers in diamond. We established a theoretical model of dual MW superposition and experimentally discovered the unusual peak in the optically detected magnetic resonance (ODMR) spectrum. The peak frequency and the full-width at half-maximum of the unusual peak, as well as fluorescence intensity in the nonresonant frequency range of the ODMR spectrum, were systematically analyzed to obtain the frequency and amplitude of the measured MW signals. The broadband MW detection was realized in a wide range of 2240–4512 MHz by utilizing the linear relation between the magnetic field and the resonant frequency in the Zeeman splitting. The experiments showed that the minimum detection power was up to 1 $\mu$ W. The proposed approach can greatly improve the practicability of detecting MW fields on chip surfaces by quantum engineering techniques.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (6) , 3514-3521
High-Dynamic-Range Detection of Microwave Signal on Chip Surface Based on Diamond Sensors
This article proposed a microwave (MW) detection method by utilizing the effect of the dual MW on nitrogen-vacancy (NV) centers in diamond. We established a theoretical model of dual MW superposition and experimentally discovered the unusual peak in the optically detected magnetic resonance (ODMR) spectrum. The peak frequency and the full-width at half-maximum of the unusual peak, as well as fluorescence intensity in the nonresonant frequency range of the ODMR spectrum, were systematically analyzed to obtain the frequency and amplitude of the measured MW signals. The broadband MW detection was realized in a wide range of 2240–4512 MHz by utilizing the linear relation between the magnetic field and the resonant frequency in the Zeeman splitting. The experiments showed that the minimum detection power was up to 1 $\mu$ W. The proposed approach can greatly improve the practicability of detecting MW fields on chip surfaces by quantum engineering techniques.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 28812-28820
Field-of-View-Breaking Localization of Magnetic Source Using Quantum Sensor
The localization and tracking of tiny magnetic source hold great potential for applications in the fields of medical and scientific research. However, cross-order-of-magnitude localization using millimeter sensor is an open problem. In this paper, we proposed a precise localization method for the tiny magnetic source that breaks through the limited field-of-view of the optical quantum sensor imaging. The position of the magnetic source is uniquely resolved by the construction of a magnetic gradient tensor (MGT) based on the vector magnetic field (2.7 mm×2.7 mm, pixel size: 3.45 μm) obtained by nitrogen-vacancy (NV) color centers in a diamond. A 3 mm diameter magnetic source is accurately located within a spatial range of 5cm with a mean error of 8%. In addition, the limitations and influencing factors of the NV-MGT localization method are theoretically discussed. The results provide insight into the localization of tiny magnetic sources and extend the application of quantum sensor.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (23) , 28812-28820
Field-of-View-Breaking Localization of Magnetic Source Using Quantum Sensor
The localization and tracking of tiny magnetic source hold great potential for applications in the fields of medical and scientific research. However, cross-order-of-magnitude localization using millimeter sensor is an open problem. In this paper, we proposed a precise localization method for the tiny magnetic source that breaks through the limited field-of-view of the optical quantum sensor imaging. The position of the magnetic source is uniquely resolved by the construction of a magnetic gradient tensor (MGT) based on the vector magnetic field (2.7 mm×2.7 mm, pixel size: 3.45 μm) obtained by nitrogen-vacancy (NV) color centers in a diamond. A 3 mm diameter magnetic source is accurately located within a spatial range of 5cm with a mean error of 8%. In addition, the limitations and influencing factors of the NV-MGT localization method are theoretically discussed. The results provide insight into the localization of tiny magnetic sources and extend the application of quantum sensor.
- 6 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
Toward Characterizing 3-D Microwave Field With Microscale Resolution Using Nitrogen-Vacancy Centers in Diamond
Measurement of radio frequency chip microwave field is of great importance for the manufacture of precision instruments and the development of integrated circuits. In this paper, the characterization of chip surface three-dimensional (3D) microwave field distribution was realized with high-resolution based on diamond nitrogen-vacancy (NV) centers, and the field-image separation technique was developed to suppress the stray light noise caused by the reflection of the chip. The feasibility of the proposed method was verified by characterizing the planar microwave fields at different powers and the 3D microwave fields at different frequencies radiated by an antenna chip with a characteristic linewidth of 100 μm. The microwave field of chip radiation was accurately reconstructed with a vertical resolution of 30 μm, and the optimal NV detection sensitivity is 0.8 nT/Hz 1/2 . The results provide a new approach for antenna radiation detection and on-chip measurement based on quantum detection techniques.
- 6 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
Toward Characterizing 3-D Microwave Field With Microscale Resolution Using Nitrogen-Vacancy Centers in Diamond
Measurement of radio frequency chip microwave field is of great importance for the manufacture of precision instruments and the development of integrated circuits. In this paper, the characterization of chip surface three-dimensional (3D) microwave field distribution was realized with high-resolution based on diamond nitrogen-vacancy (NV) centers, and the field-image separation technique was developed to suppress the stray light noise caused by the reflection of the chip. The feasibility of the proposed method was verified by characterizing the planar microwave fields at different powers and the 3D microwave fields at different frequencies radiated by an antenna chip with a characteristic linewidth of 100 μm. The microwave field of chip radiation was accurately reconstructed with a vertical resolution of 30 μm, and the optimal NV detection sensitivity is 0.8 nT/Hz 1/2 . The results provide a new approach for antenna radiation detection and on-chip measurement based on quantum detection techniques.