JZJinyi Zhang

Jinyi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinyi Zhang has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Field-Deployable and Ultrasensitive Surface-Enhanced Raman Spectroscopy for Waterborne Arsenic Monitoring Based on Headspace Formation of Arsenic–Silver Nanocomposites

    by Zhinan Chen, Zhankuo Zhang, Xiangyu Liu, Kailai Xu, Yue Qi, Jinyi Zhang, Chengbin Zheng

    Millions of people worldwide are exposed to arsenic-contaminated water, driving an urgent need for field-deployable analytical tools. However, direct, label-free surface-enhanced Raman spectroscopy (SERS) detection of arsenic is hindered by its weak Raman activity and complex matrix interference. Herein, we report an ultrasensitive SERS platform that addresses these issues by integrating hydride generation, headspace solid-phase extraction, and in situ substrate formation into a single step. The target arsenic is converted to volatile AsH3, which simultaneously reduces Ag+ to silver nanoparticles (AgNPs) and codeposits with its oxidation products to form arsenic-associated AgNP composites (As-AgNPs). This design eliminates the need for external Raman reporters or prefabricated SERS substrates and, critically, enables direct fingerprint identification of arsenic via characteristic peaks at 425 and 790 cm–1 under the tested conditions. The in situ generated dense AgNP hotspots, synergized with headspace preconcentration, afford a 2.6% signal relative standard deviation at 10 ppb As(III) (n = 21) and a detection limit as low as 0.085 ppb, alongside tolerance to the coexisting ions under the tested conditions. Field testing at the Minjiang River using a portable Raman spectrometer yielded results in agreement with atomic fluorescence spectrometry (t-test, 95% confidence), with a total assay time of 30 min for six parallel samples. This work provides a robust, field-deployable solution for direct trace arsenic monitoring by coupling analyte collection with reaction-synchronized SERS substrate formation.

  • Iron Single-Atom Catalyst Boosting Dried Blood Spots Digestion for High-Throughput Detection of Arsenic and Cadmium

    by Xiaofang Yang, Jinyi Zhang, Jie Tang, Jiahui Yang, Chengbin Zheng

    Herein, a novel Fenton-like digestion strategy has been developed for undiluted, rapid, and high-throughput digestion of DBS samples. The key of this strategy is the development of a blood collection card loaded with iron single-atom catalysts (Fe-SACs). Then, approximately 40 μL of blood sample was dripped onto the Fe-SACs blood collection card and digested with tens of microliters of H2O2 at 75 °C. Remarkably, digestion of the DBS sample can be achieved within 5 min. It is proposed that the Fe-SACs with their high atomic utilization efficiency, are uniformly immobilized on the paper substrate, thereby increasing the contact area with blood and significantly enhancing sample digestion efficiency. Furthermore, it is worth noting that the issues of intense reaction and severe matrix interference associated with the conventional Fenton-like digestion of whole blood are effectively alleviated by performing the digestion process directly on the paper. The preparation of DBS samples and their Fe-SACs-based Fenton-like digestion can be carried out in a 24-well plate, enabling a theoretical digestion of up to 288 samples per hour, greatly improving sample digestion throughput. The practicality of the developed method was evaluated by analyzing a series of real blood samples. The results showed good agreement with those obtained using conventional wet digestion followed by inductively coupled plasma mass spectrometry (ICP-MS), indicating this strategy retains a good potential for the rapid and efficient digestion of whole blood samples.

  • Endogenous Fluorescence Turn-On of Nitro-Containing Nitazenes via In Situ Reduction for Rapid Detection

    by Yuyang Li, Linchuan Liao, Li Yang, Lu Zhang, Qifu Zhang, Jinyi Zhang, Yao Lin, Chengbin Zheng

    Nitazenes, a rapidly expanding class of highly potent synthetic opioids, have raised global concerns due to their high abuse potential and detrimental effects on both health and social stability. The fluorescence detection of nitazenes remains challenging, primarily due to the limited specificity of exogenous probe-based methods, and very few fluorescence-based assays have been reported for these compounds to date. Herein, we report an endogenous fluorescence turn-on strategy for the rapid detection of nitro-containing nitazenes via precise modulation of their intrinsic fluorescence through in situ chemical reduction. Using Na2S2O4 as the reducing agent, the nitro group is converted to an electron-donating amino group, which restores the conjugation-driven emission and triggers a remarkable fluorescence turn-on response. The proposed mechanism was supported by fluorescence lifetime analysis, liquid chromatography-high-resolution mass spectrometry/tandem mass spectrometry (LC-HRMS/MS), and time-dependent density functional theory (TD-DFT) calculations. The method successfully detected four representative nitazenes (etonitazene, metonitazene, protonitazene, and isotonitazene) with a detection limit as low as 12.57 nM, achieving analytical performance comparable to that of HPLC. Furthermore, the practical applicability was validated in complex biological matrices, including 50% saliva and 50% urine. This endogenous fluorescence activation strategy offers distinct advantages of simplicity, rapidity, and probe-free reaction-triggered signal generation, which would open new possibilities for the direct fluorescence detection of emerging psychoactive substances featuring reducible nitroaromatic groups, thereby holding great promise for on-site forensic analysis and public security screening.

  • A distance-readable gas pressure sensing device for on-site monitoring of the permanganate index (CODMn) in surface water

    by Dali Zhuo, Yuanyuan He, Linghuan Li, Xiaoyu Dong, Xiaoli Xiong, Huimin Yu, Ke Huang, Jinyi Zhang, Zhirong Zou


  • Solid-Phase Fluorescence Filter Effect Based Test Kit for Field Testing of COD Mn in Surface Water

    by Yuanyuan Liu, Jinyi Zhang, Zhankuo Zhang, Yao Lin, Yurong Deng, Chengbin Zheng

    On-site rapid monitoring of the permanganate index (CODMn) is critical for assessing the distribution and transformation of dissolved organic matter (DOM) in surface water. Herein, we proposed a portable field test kit for rapid, visual, and cost-effective CODMn detection, complemented by an unmanned vessel for automated sampling. The method exploits the solid-phase fluorescence filter effect (SPFFE) between carbon dots (CDs) and iodine, enabling the quantification of residual KMnO4 (calculated as CODMn). A smartphone-based reader and a user-friendly fluorescence reference card were developed for quantitative analysis of CODMn and water quality classification. Under optimal conditions, a limit of detection (LOD) of 0.04 mg L–1 was obtained for CODMn with relative standard deviations (RSDs) better than 2.0%. In a field application, 33 water samples were collected and analyzed across a 133,300 m2 lake within 2 h. The results demonstrated a strong agreement with the standard method, exhibiting enhanced sensitivity, reproducibility, and portability. Spatial mapping further revealed that CODMn distribution patterns were influenced by local environmental features. This work establishes a mechanism-driven analytical strategy that couples a previously unexplored SPFFE modulation with field-deployable test kit design and autonomous sampling, advancing practical CODMn measurement for decentralized water quality monitoring and providing a scalable solution for real-time environmental surveillance.


  • Signal-Enhanced Dielectric Barrier Discharge Microplasma Coupled to GC for Sensitive Analysis of Low-Molecular-Weight Gases in Swollen Lithium Polymer Batteries

    by Zhi-Ang Li, Xin Zhou, Jinyi Zhang, Liwen Zheng, Yao Lin, Chengbin Zheng

    The real-time monitoring of low-molecular-weight gases generated during lithium polymer battery (LPB) degradation is crucial for safety. However, the simultaneous and sensitive detection of both inorganic and organic species remains a significant challenge for gas chromatography (GC). Herein, we developed an enhanced dielectric barrier discharge (DBD) microplasma detector that addresses this limitation. By leveraging the atomic or molecular emission characteristics of elements within the plasma, this detector can analyze O2, N2, H2, CO2, CO, CH4, C2H4, C2H6, and polyaromatic hydrocarbons with high sensitivity. The enhanced discharge apparatus physically isolates the electrodes from the plasma chamber, thereby preventing carbon deposition and delivering superior signal strength and stability compared to conventional designs. Furthermore, the influence of discharge chamber dimensions on signal performance was systematically investigated. Under optimal conditions, the detection of limits for H2, CO, CO2, CH4, C2H4, and C2H6 were 6, 0.3, 0.3, 0.5, 0.1, and 0.1 μmol/mol, respectively, significantly outperforming previous reports and commercial detectors. The accuracy of this strategy was confirmed with standard gases, and its practical utility was successfully demonstrated by analyzing gases from real swollen LPBs. This work provides a highly promising and universal solution for sophisticated gas analysis in LPB safety assessment.


  • Wearable Formaldehyde Dosimeter for Field-Ready Monitoring of Occupational Exposure and Indoor Air Quality via an Enhanced Hantzsch Reaction

    by Simin Ye, Zhankuo Zhang, Li Yang, Zhiang Li, Xiaofang Yang, Jinyi Zhang, Chengbin Zheng

    Formaldehyde (HCHO, FA) poses critical health risks ranging from respiratory irritation to carcinogenicity. However, the existing detection strategies often fail to address the dual challenges of on-site acute toxicity monitoring and long-term cumulative exposure assessment. Here, we develop a ratiometric fluorescent sensing platform synergizing the solid-phase fluorescence internal filtering effect (SPFFE) with Hantzsch reaction chemistry, enabling three-tier FA analysis: (1) For complex matrices, SPFFE-separated gas-liquid phase detection achieves 0.03 mg/L sensitivity without pretreatment. (2) For indoor air monitor, 30 min passive sampling delivers 0.01 ppmv visual detection, correlating with WHO acute exposure limits. (3) A wearable paper-based dosimeter quantifies time-weighted average exposure (8-h detection window) through a cumulative signal. Field deployment revealed substantial spatial HCHO variations: bedrooms (0.02-0.07 ppmv), living rooms (0.09-0.12 ppmv), and study rooms (0.31-0.49 ppmv) with enclosed cabinets/drawers exceeded safety limits by 7.5-17.3×, highlighting microenvironmental risks from wood-panel emissions. Wearable dosimetry captured spatiotemporal exposure dynamics (6.3-22.5 vs 1.2-4.8 ppmv·min in high/low emission zones), demonstrating 89% peak exposures during cabinet access and >82% dose contribution from airflow-modulated panel emissions, informing activity-dependent mitigation strategies. This dual-mode system bridges critical gaps between regulatory compliance monitoring and personalized exposure tracking, particularly demonstrating utility for high-risk occupations (3.1-8.7× higher exposure than residential scenarios in decoration workers). The technology establishes a scalable framework for implementing "detect-to-protect" strategies in environmental health management.


  • Underestimated Toxicity: UV Amplifies Low-Dose Cr(VI) Damage to Skin at Molecular and Tissue Levels

    by Jie Tang, Wei Hua, Ruixuan Lu, Yao Lin, Xueshan Chen, Kailai Xu, Huimin Yu, Jinyi Zhang, Chengbin Zheng

    Chromium(VI) [Cr(VI)] is a well-documented environmental carcinogen linked to DNA damage, oxidative stress, and systemic toxicity. Existing risk assessments predominantly focus on single-factor high-dose occupational exposures, while it is usually overlooked that Cr(VI) exists at a low level and coexists with environmental factors in real-world scenarios; thus, assessing the synergistic toxicity of low-dose Cr(VI) with coexposure is imperative. Herein, we reveal that UV irradiation critically amplifies the toxicity of low-dose Cr(VI) at both the molecular and tissue levels. Integrated in vitro and in vivo models, we demonstrate that UV-induced redox cycling of Cr(VI) generates reactive oxygen species (ROS), inducing DNA and protein cleavage, cytotoxicity, and skin barrier damage. Notably, acute UV-Cr(VI) coexposure compromises skin barrier function, evidenced by a 50% increase in transepidermal water loss and disorganized stratum corneum ultrastructure (epidermal thickening, aberrant basal cell activation, and infiltration of inflammatory cells). These findings establish UV as a critical enhancer of Cr(VI) toxicity, revealing the synergistic toxicity of low-dose Cr(VI) and UV irradiation at molecular and tissue levels and challenging the traditional threshold-based safety Cr(VI) dosage. This work emphasizes the urgent need to re-evaluate environmental Cr(VI) risks under real-world light-exposed scenarios, with implications for sunscreen formulations, occupational safety guidelines, and ecological regulations in the face of growing environmental challenges.


  • Matrix-Engineered Self-Assembly of Fluorophores Based on Acidic Annealing for Robust Cellular Imaging

    by Xueshan Chen, Jie Tang, Lingqiao Zhang, Zhankuo Zhang, Jinyi Zhang, Chengbin Zheng

    A key limitation of fluorescein derivatives is acid-induced aggregation, resulting in an inactivation. However, the aggregates obtained after acid annealing showed a 50-fold enhancement of fluorescence compared with the original powder. Herein, we incorporated a polymer or surfactant matrix into the acidic annealing procedure, and the self-assembling properties of fluorescein derivatives in the presence of the matrix are exploited to alter the molecular structure, thereby modifying the optical properties and ultimately producing fluorescent materials with enhanced brightness. Varying the type and concentration of dyes and matrices as well as the assembly time can modulate the geometry of the particles. These biocompatible particles exhibit efficient cellular uptake and superior imaging capabilities, positioning them as potent carriers for traceability. The stability of the assembly against light exposure and high temperatures demonstrates its practical application capabilities. By synergizing host-guest recognition with supramolecular engineering, this work not only redefines acid adaptation mechanisms but also establishes a universal design strategy for multifunctional supramolecular architecture, which expands applications in complex biological systems and opens new pathways for engineering advanced superstructures.


  • Vapor I2-Mediated Robust Aggregation/Etching of Silver Nanoparticles for Sensitive and On-Site SERS Monitoring of Iodine in Seawater

    by Zhinan Chen, Ruiqi Gao, Xueshan Chen, Zhankuo Zhang, Yao Lin, Kailai Xu, Jinyi Zhang, Chengbin Zheng

    While oceanic iodine plays a critical role in monitoring marine pollution and biogeochemical cycles, existing detection methods suffer from compromised sensitivity, laborious pretreatment, and field-incompatible operation. Herein, we present a vapor-phase molecular recognition strategy that leverages iodine (I2)-induced structural transformation of silver nanoparticles (AgNPs) for surface-enhanced Raman scattering (SERS) indirect detection, with rhodamine 6G (Rh6G) as a Raman probe of seawater iodine. Spectroscopic and electron microscopic results showed that I2 induced stronger sequential aggregation and anisotropic etching of nanoparticles than I-, effectively suppressing SERS enhancement. Theoretical calculations reveal that I2 exhibits a 3-fold stronger binding affinity with AgNPs compared to I-. By integrating headspace sampling with paper-based SERS substrates, this method achieves matrix interference elimination through gas-solid phase separation while enhancing sensitivity via vapor preconcentration. The developed approach demonstrates a low detection limit of 15.1 nM for iodide (RSD = 5.0%, n = 15), with a linear response across 50-1000 nM, and no significant interference with coexisting anions at 1000-fold higher concentrations. Field deployment along the Southeast China Sea coastline showed excellent correlation with standard mass spectrometry measurements. This work not only elucidates the molecular-level interaction between I2 and noble metal nanostructures but also establishes a new paradigm for in-field detection of marine radioactive isotopes through vapor-phase reaction engineering.