Jin-Seong Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jin-Seong Cho has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jeong-Hwan Kim
Department of Naval Architecture and Ocean Engineering, Dong-A University, Busan 49315, Republic of Korea
4 shared publications - Young Il Park
Department of Naval Architecture and Ocean Engineering, Dong-A University, Busan 49315, Republic of Korea
3 shared publications - Young Il Park1 shared publication
Latest Publications
- Open Access
- 28 February 2023
- Published by Journal of Advanced Marine Engineering and Technology in Journal of Advanced Marine Engineering and Technology
- Vol. 47 (1) , 16-22
A study on the effect of dynamic material strain on the dynamic crushing behavior of steel structures subjected to impact loads
- 28 February 2023
- Published by Journal of Advanced Marine Engineering and Technology in Journal of Advanced Marine Engineering and Technology
- Vol. 47 (1) , 16-22
Open AccessA study on the effect of dynamic material strain on the dynamic crushing behavior of steel structures subjected to impact loads
- Open Access
- 30 June 2022
- Published by Journal of Advanced Marine Engineering and Technology in Journal of Advanced Marine Engineering and Technology
- Vol. 46 (3) , 101-106
Numerical study of quasi-static crushing behaviors of steel tubular structures according to the slenderness ratio
- 30 June 2022
- Published by Journal of Advanced Marine Engineering and Technology in Journal of Advanced Marine Engineering and Technology
- Vol. 46 (3) , 101-106
Open AccessNumerical study of quasi-static crushing behaviors of steel tubular structures according to the slenderness ratio
- Open Access
Numerical and Experimental Investigation of Quasi-Static Crushing Behaviors of Steel Tubular Structures
In this study, a numerical and experimental investigation of the quasi-static crushing behavior of steel tubular structures was conducted. As the crushing failure behavior involves a high level of nonlinearity for the numerical simulations, these were compared with previous experimental works, including crushing tests of steel square tubes to calibrate the numerical results. Six parameters for the numerical simulations, namely (1) loading boundary condition, (2) geometrical imperfection, (3) friction coefficient, (4) element size, (5) element type, and (6) material nonlinearity model, were examined using a series of finite element analyses. Through the sensitivity study for each parameter, the deformation and crushing load of the steel tube were investigated, and the value that best matched the experimental results was selected. The results of the numerical analysis for the determined model were compared with the experimental results. Finally, the authors provided recommendations that should be considered when performing nonlinear finite element simulations of crushing failure events.
Open AccessNumerical and Experimental Investigation of Quasi-Static Crushing Behaviors of Steel Tubular Structures
In this study, a numerical and experimental investigation of the quasi-static crushing behavior of steel tubular structures was conducted. As the crushing failure behavior involves a high level of nonlinearity for the numerical simulations, these were compared with previous experimental works, including crushing tests of steel square tubes to calibrate the numerical results. Six parameters for the numerical simulations, namely (1) loading boundary condition, (2) geometrical imperfection, (3) friction coefficient, (4) element size, (5) element type, and (6) material nonlinearity model, were examined using a series of finite element analyses. Through the sensitivity study for each parameter, the deformation and crushing load of the steel tube were investigated, and the value that best matched the experimental results was selected. The results of the numerical analysis for the determined model were compared with the experimental results. Finally, the authors provided recommendations that should be considered when performing nonlinear finite element simulations of crushing failure events.
- Open Access
Structural Integrity Assessment of Independent Type-C Cylindrical Tanks Using Finite Element Analysis: Comparative Study Using Stainless Steel and Aluminum Alloy
The International Maritime Organization stipulates that greenhouse gas emissions from ships should be reduced by at least 50% relative to the amount observed in 2008. Consequently, the demand for liquefied natural gas (LNG)-fueled ships has increased significantly. Therefore, an independent type-C cylindrical tank, which is typically applied as an LNG fuel tank, should be investigated. In this study, structural integrity assessments using finite element analysis are performed on C-type LNG fuel tanks for a sea-cleaning vessel. In addition, the applicability of stainless steel and aluminum alloys is evaluated for LNG tank construction. Structural analyses and fatigue limit evaluations, including heat transfer analyses for the tank based on IGC code requirements, are performed, and the results are compared. The results of this study are expected to facilitate the selection of materials used for independent type-C tanks.
Open AccessStructural Integrity Assessment of Independent Type-C Cylindrical Tanks Using Finite Element Analysis: Comparative Study Using Stainless Steel and Aluminum Alloy
The International Maritime Organization stipulates that greenhouse gas emissions from ships should be reduced by at least 50% relative to the amount observed in 2008. Consequently, the demand for liquefied natural gas (LNG)-fueled ships has increased significantly. Therefore, an independent type-C cylindrical tank, which is typically applied as an LNG fuel tank, should be investigated. In this study, structural integrity assessments using finite element analysis are performed on C-type LNG fuel tanks for a sea-cleaning vessel. In addition, the applicability of stainless steel and aluminum alloys is evaluated for LNG tank construction. Structural analyses and fatigue limit evaluations, including heat transfer analyses for the tank based on IGC code requirements, are performed, and the results are compared. The results of this study are expected to facilitate the selection of materials used for independent type-C tanks.