Michael P. Milz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael P. Milz has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Wirtz
Institute of Machining Technology (ISF), TU Dortmund University, Baroper Str. 303, 44227 Dortmund, Germany
4 shared publications - Dirk Biermann
Institute of Machining Technology, TU Dortmund University, 44227 Dortmund, Germany
4 shared publications - Frank Walther
Chair of Materials Test Engineering (WPT) TU Dortmund University Dortmund Germany
4 shared publications - Mohamed Abdulgader
Institute of Materials Engineering, TU Dortmund University, Leonhard-Euler-Str. 2, 44227 Dortmund, Germany
4 shared publications - Wolfgang Tillmann
Institute of Materials Engineering, TU Dortmund University, Leonhard-Euler-Strasse 2, 44227 Dortmund, Germany
4 shared publications - Anke Kalenborn
Chair of Materials Test Engineering (WPT), TU Dortmund University, Baroper Str. 303, 44227 Dortmund, Germany
1 shared publication
Latest Publications
- Open Access
- 2 March 2022
- Published by MDPI AG in Corrosion and Materials Degradation
- Vol. 3 (1) , 127-141
Corrosion Fatigue Behavior of Twin Wire Arc Sprayed and Machine Hammer Peened ZnAl4 Coatings on S355 J2C + C Substrate
Offshore installations, e.g., offshore wind turbines and pipelines, are exposed to various mechanical loads due to wind or waves and corrosive loads such as seawater or mist. ZnAl-based thermal sprayed coatings, often in conjunction with organic coatings, provide sufficient corrosion protection and are well established for applications in marine environments. In this study, machine hammer peening (MHP) is applied after twin wire arc spraying to improve corrosion fatigue behavior through increased hardness, reduced porosity, and roughness compared to as-sprayed coatings. Mn-alloyed structural steel S355 J2 + C with and without ZnAl4 coating as well as with MHP post-treated ZnAl4 coating were cyclically loaded in 3.5% NaCl solution. MHP leads to a uniform coating thickness with lower porosity and roughness. ZnAl4 coating and MHP post-treatment improved corrosion fatigue behavior in the high cycle fatigue regime with an increase of the stress amplitude, applied to reach a number of cycles 1.2 × 106, up to 115% compared to sandblasted specimens. Corrosive attack of the substrate steel was successfully avoided by using the coating systems. Stress- and microstructure-dependent corrosion fatigue damage mechanisms were evaluated by mechanical and electrochemical measurement techniques.
- 2 March 2022
- Published by MDPI AG in Corrosion and Materials Degradation
- Vol. 3 (1) , 127-141
Open AccessCorrosion Fatigue Behavior of Twin Wire Arc Sprayed and Machine Hammer Peened ZnAl4 Coatings on S355 J2C + C Substrate
Offshore installations, e.g., offshore wind turbines and pipelines, are exposed to various mechanical loads due to wind or waves and corrosive loads such as seawater or mist. ZnAl-based thermal sprayed coatings, often in conjunction with organic coatings, provide sufficient corrosion protection and are well established for applications in marine environments. In this study, machine hammer peening (MHP) is applied after twin wire arc spraying to improve corrosion fatigue behavior through increased hardness, reduced porosity, and roughness compared to as-sprayed coatings. Mn-alloyed structural steel S355 J2 + C with and without ZnAl4 coating as well as with MHP post-treated ZnAl4 coating were cyclically loaded in 3.5% NaCl solution. MHP leads to a uniform coating thickness with lower porosity and roughness. ZnAl4 coating and MHP post-treatment improved corrosion fatigue behavior in the high cycle fatigue regime with an increase of the stress amplitude, applied to reach a number of cycles 1.2 × 106, up to 115% compared to sandblasted specimens. Corrosive attack of the substrate steel was successfully avoided by using the coating systems. Stress- and microstructure-dependent corrosion fatigue damage mechanisms were evaluated by mechanical and electrochemical measurement techniques.
- Open Access
Fatigue Assessment of Twin Wire Arc Sprayed and Machine Hammer-Peened ZnAl4 Coatings on S355 JRC+C Substrate
Structural elements for applications in maritime environments, especially offshore installations, are subjected to various stresses, such as mechanical loads caused by wind or waves and corrosive attacks, e.g., by seawater, mist and weather. Thermally sprayed ZnAl coatings are often used for maritime applications, mainly due to good corrosion protection properties. Machine hammer peening (MHP) has the potential to increase fatigue and corrosion fatigue resistance of ZnAl coatings by adjusting various material properties such as hardness, porosity and roughness. This study investigates the fatigue behavior of twin wire arc sprayed and MHP post-treated ZnAl4 coatings. Unalloyed steel (S355 JRC+C) was selected as substrate material and tested as a reference. MHP achieved the desired improvements in material properties with increased hardness, decreased roughness and uniform coating thickness. Multiple and constant amplitude tests have been carried out to evaluate the fatigue capability of coating systems. In the high cycle fatigue regime, the additional MHP post-treatment led to an improvement of the lifetime in comparison to pure sandblasted specimens. The surface was identified as a crack initiation point. ZnAl coating and MHP post-treatment are suitable to improve the fatigue behavior in the high cycle fatigue regime compared to uncoated specimens.
Open AccessFatigue Assessment of Twin Wire Arc Sprayed and Machine Hammer-Peened ZnAl4 Coatings on S355 JRC+C Substrate
Structural elements for applications in maritime environments, especially offshore installations, are subjected to various stresses, such as mechanical loads caused by wind or waves and corrosive attacks, e.g., by seawater, mist and weather. Thermally sprayed ZnAl coatings are often used for maritime applications, mainly due to good corrosion protection properties. Machine hammer peening (MHP) has the potential to increase fatigue and corrosion fatigue resistance of ZnAl coatings by adjusting various material properties such as hardness, porosity and roughness. This study investigates the fatigue behavior of twin wire arc sprayed and MHP post-treated ZnAl4 coatings. Unalloyed steel (S355 JRC+C) was selected as substrate material and tested as a reference. MHP achieved the desired improvements in material properties with increased hardness, decreased roughness and uniform coating thickness. Multiple and constant amplitude tests have been carried out to evaluate the fatigue capability of coating systems. In the high cycle fatigue regime, the additional MHP post-treatment led to an improvement of the lifetime in comparison to pure sandblasted specimens. The surface was identified as a crack initiation point. ZnAl coating and MHP post-treatment are suitable to improve the fatigue behavior in the high cycle fatigue regime compared to uncoated specimens.
- Open Access
The Effect of Argon as Atomization Gas on the Microstructure, Machine Hammer Peening Post-Treatment, and Corrosion Behavior of Twin Wire Arc Sprayed (TWAS) ZnAl4 Coatings
In the twin wire arc spraying (TWAS) process, it is common to use compressed air as atomizing gas. Nitrogen or argon also are used to reduce oxidation and improve coating performance. The heat required to melt the feedstock material depends on the electrical conductivity of the wires used and the ionization energy of both the feedstock material and atomization gas. In the case of ZnAl4, no phase changes were recorded in the obtained coatings by using either compressed air or argon as atomization gas. This fact has led to the assumption that the melting behavior of ZnAl4 with its low melting and evaporating temperature is different from materials with a higher melting point, such as Fe and Ni, which also explains the unexpected compressive residual stresses in the as-sprayed conditions. The heavier atomization gas, argon, led to slightly higher compressive stresses and oxide content. Compressed air as atomization gas led to lower porosity, decreased surface roughness, and better corrosion resistance. In the case of argon, Al precipitated in the form of small particles. The post-treatment machine hammer peening (MHP) has induced horizontal cracks in compressed air sprayed coatings. These cracks were mainly initiated in the oxidized Al phase.
Open AccessThe Effect of Argon as Atomization Gas on the Microstructure, Machine Hammer Peening Post-Treatment, and Corrosion Behavior of Twin Wire Arc Sprayed (TWAS) ZnAl4 Coatings
In the twin wire arc spraying (TWAS) process, it is common to use compressed air as atomizing gas. Nitrogen or argon also are used to reduce oxidation and improve coating performance. The heat required to melt the feedstock material depends on the electrical conductivity of the wires used and the ionization energy of both the feedstock material and atomization gas. In the case of ZnAl4, no phase changes were recorded in the obtained coatings by using either compressed air or argon as atomization gas. This fact has led to the assumption that the melting behavior of ZnAl4 with its low melting and evaporating temperature is different from materials with a higher melting point, such as Fe and Ni, which also explains the unexpected compressive residual stresses in the as-sprayed conditions. The heavier atomization gas, argon, led to slightly higher compressive stresses and oxide content. Compressed air as atomization gas led to lower porosity, decreased surface roughness, and better corrosion resistance. In the case of argon, Al precipitated in the form of small particles. The post-treatment machine hammer peening (MHP) has induced horizontal cracks in compressed air sprayed coatings. These cracks were mainly initiated in the oxidized Al phase.
- Open Access
- 14 October 2021
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 5 (4) , 109
Thermally Assisted Machine Hammer Peening of Arc-Sprayed ZnAl-Based Corrosion Protective Coatings
Structural elements of offshore facilities, e.g., offshore wind turbines, are subject to static and dynamic mechanical and environmental loads, for example, from wind, waves, and corrosive media. Protective coatings such as thermal sprayed ZnAl coatings are often used for protection, mainly against corrosive stresses. The Machine Hammer Peening (MHP) process is an innovative and promising technique for the post-treatment of ZnAl coating systems that helps reducing roughness and porosity and inducing compressive residual stresses. This should lead to an enhancement of the corrosion fatigue behavior. In this paper, the effect of a thermally assisted MHP process was investigated. The softening of the coating materials will have a direct effect on the densification, residual porosity and the distribution of cracks. The investigation results showed the influence of thermally assisted MHP on the surface properties, porosity, residual stresses, and hardness of the post-treated coatings. The best densification of the coating, i.e., the lowest porosity and roughness and the highest compressive residual stresses, were achieved at a process temperature of 300 °C. A further increase in temperature on the other hand caused a higher porosity and, in some cases, locally restricted melting of the coating and consequently poorer coating properties.
- 14 October 2021
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 5 (4) , 109
Open AccessThermally Assisted Machine Hammer Peening of Arc-Sprayed ZnAl-Based Corrosion Protective Coatings
Structural elements of offshore facilities, e.g., offshore wind turbines, are subject to static and dynamic mechanical and environmental loads, for example, from wind, waves, and corrosive media. Protective coatings such as thermal sprayed ZnAl coatings are often used for protection, mainly against corrosive stresses. The Machine Hammer Peening (MHP) process is an innovative and promising technique for the post-treatment of ZnAl coating systems that helps reducing roughness and porosity and inducing compressive residual stresses. This should lead to an enhancement of the corrosion fatigue behavior. In this paper, the effect of a thermally assisted MHP process was investigated. The softening of the coating materials will have a direct effect on the densification, residual porosity and the distribution of cracks. The investigation results showed the influence of thermally assisted MHP on the surface properties, porosity, residual stresses, and hardness of the post-treated coatings. The best densification of the coating, i.e., the lowest porosity and roughness and the highest compressive residual stresses, were achieved at a process temperature of 300 °C. A further increase in temperature on the other hand caused a higher porosity and, in some cases, locally restricted melting of the coating and consequently poorer coating properties.