DMDonald T. Miller

Donald T. Miller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Donald T. Miller has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Structural analysis of cone photoreceptors in AO-OCT enables S-cone identification by a support vector machine classifier

    by Qiuzhi Ji, Marcel T. Bernucci, Yan Liu, James A. Crowell, Davin J. Miller, Donald T. Miller

    Adaptive optics optical coherence tomography (AO-OCT) enables high-resolution, 3-dimensional imaging of cone photoreceptors in the living human retina. Histological studies have shown that short-wavelength-sensitive (S) cones are structurally distinct from medium- (M) and long-wavelength-sensitive (L) cones. However, current in vivo methods for classifying cones–such as retinal densitometry and optoretinography–are technically demanding because they require measuring cone function. Quantifying structural differences with AO-OCT may provide a simpler and faster alternative and offer new biomarkers for understanding how disease differentially affects photoreceptor subtypes. Here, we present a quantitative method that applies a support vector machine (SVM) classifier to structural measurements of AO-OCT volumes to identify individual S cones. We measured six structural parameters related to the inner and outer segments of each cone. Among 13,836 cones analyzed across six subjects, we found S cones exhibited significantly longer inner segments, shorter outer segments, and wider diameters at the inner/outer segment junction than M and L cones. Although M and L cones are widely regarded as morphologically indistinguishable, we also found that L cones, on average, had longer outer segments than M cones. These structural differences were consistent across five of the six subjects at a single retinal eccentricity of 3.7° and across eccentricities from 2° to 12° temporal in one subject. Our SVM model used these features to achieve high classification accuracy for S cones. Validation of classification performance against optoretinography on the same eyes yielded F1 scores ranging from 0.78 to 0.93 in five of the six subjects.


  • Integrated fixation and stimulus channel for adaptive optics ophthalmoscopy

    by Marcel T. Bernucci, Yan Liu, Qiuzhi Ji, James A. Crowell, Kristen Bowles-Johnson, Matthew J. Keller, Donald T. Miller

    Adaptive optics (AO) ophthalmoscopes allow high-resolution imaging of retinal structure and function at the cellular level. Due to their high magnification and small field-of-view (FOV), these systems require precise fixation and light delivery to control the retinal region being imaged and stimulated. We present a high-efficiency fixation and stimulus channel for AO ophthalmoscopy, offering an extended working distance, wide steering range, and broad dioptric correction. For stimulation, the channel delivers intense, near-monochromatic light flashes across much of the visible spectrum. Our design uses all stock components, except for a 3D-printed conic mount and a few machined parts. We balance key system trade-offs and demonstrate design performance through several AO optical coherence tomography (AO-OCT) structural and functional imaging examples. Although originally developed for the Indiana AO-OCT system, these design principles can be readily applied to other AO ophthalmoscopic platforms.


  • Open Access

    Ultrafast adaptive optics for imaging the living human eye

    by Yan Liu, James A. Crowell, Kazuhiro Kurokawa, Marcel T. Bernucci, Qiuzhi Ji, Ayoub Lassoued, Hae Won Jung, Matthew J. Keller, Mary E. Marte, Donald T. Miller

    Adaptive optics (AO) is a powerful method for correcting dynamic aberrations in numerous applications. When applied to the eye, it enables cellular-resolution retinal imaging and enhanced visual performance and stimulation. Most ophthalmic AO systems correct dynamic aberrations up to 1−2 Hz, the commonly-known cutoff frequency for correcting ocular aberrations. However, this frequency may be grossly underestimated for more clinically relevant scenarios where the medical impact of AO will be greatest. Unfortunately, little is known about the aberration dynamics in these scenarios. A major bottleneck has been the lack of sufficiently fast AO systems to measure and correct them. We develop an ultrafast ophthalmic AO system that increases AO bandwidth by ~30× and improves aberration power rejection magnitude by 500×. We demonstrate that this much faster ophthalmic AO is possible without sacrificing other system performances. We find that the discontinuous-exposure AO-control scheme runs 32% slower yet achieves 53% larger AO bandwidth than the commonly used continuous-exposure scheme. Using the ultrafast system, we characterize ocular aberration dynamics in six clinically-relevant scenarios and find their power spectra to be 10−100× larger than normal. We show that ultrafast AO substantially improves aberration correction and retinal imaging performance in these scenarios compared with conventional AO.


  • Open Access

    Cone photoreceptor dysfunction in retinitis pigmentosa revealed by optoretinography

    by Ayoub Lassoued, Furu Zhang, Kazuhiro Kurokawa, Yan Liu, Marcel T. Bernucci, James A. Crowell, Donald T. Miller

    Significance: Many blinding diseases afflict photoreceptors, specialized cells in the retina that capture and transduce light to initiate vision. Biomarkers that are sensitive to photoreceptor health are crucial for early detection and effective treatment monitoring of these diseases yet remain elusive. Here, we develop an optical biomarker, based on optoretinographic photoreceptor responses to light stimulation, that reflects the degree of dysfunction of individual cone photoreceptors in patients with retinitis pigmentosa (RP), the most common inherited retinal degenerative disease. Our results show that this biomarker may be beneficial for assessing the functionality of remaining retinal cells in RP patients and for assessing efficacy of treatments such as gene therapy and stem cell transplantation for RP and other diseases afflicting photoreceptors.


  • Top Cited Papers

    Adaptive optics for high-resolution imaging

    by Karen M. Hampson, Raphaël Turcotte, Donald T. Miller, Kazuhiro Kurokawa, Jared R. Males, Na Ji, Martin J. Booth

    Adaptive optics (AO) is a technique that corrects for optical aberrations. It was originally proposed to correct for the blurring effect of atmospheric turbulence on images in ground-based telescopes and was instrumental in the work that resulted in the Nobel prize-winning discovery of a supermassive compact object at the centre of our galaxy. When AO is used to correct for the eye’s imperfect optics, retinal changes at the cellular level can be detected, allowing us to study the operation of the visual system and to assess ocular health in the microscopic domain. By correcting for sample-induced blur in microscopy, AO has pushed the boundaries of imaging in thick tissue specimens, such as when observing neuronal processes in the brain. In this primer, we focus on the application of AO for high-resolution imaging in astronomy, vision science and microscopy. We begin with an overview of the general principles of AO and its main components, which include methods to measure the aberrations, devices for aberration correction, and how these components are linked in operation. We present results and applications from each field along with reproducibility considerations and limitations. Finally, we discuss future directions.


  • Cellular-Scale Imaging of Transparent Retinal Structures and Processes Using Adaptive Optics Optical Coherence Tomography

    by Donald T. Miller, Kazuhiro Kurokawa

    High-resolution retinal imaging is revolutionizing how scientists and clinicians study the retina on the cellular scale. Its exquisite sensitivity enables time-lapse optical biopsies that capture minute changes in the structure and physiological processes of cells in the living eye. This information is increasingly used to detect disease onset and monitor disease progression during early stages, raising the possibility of personalized eye care. Powerful high-resolution imaging tools have been in development for more than two decades; one that has garnered considerable interest in recent years is optical coherence tomography enhanced with adaptive optics. State-of-the-art adaptive optics optical coherence tomography (AO-OCT) makes it possible to visualize even highly transparent cells and measure some of their internal processes at all depths within the retina, permitting reconstruction of a 3D view of the living microscopic retina. In this review, we report current AO-OCT performance and its success in visualizing and quantifying these once-invisible cells in human eyes.


  • Open Access

    Photoreceptor disc shedding in the living human eye

    by Omer P. Kocaoglu, Zhuolin Liu, Furu Zhang, Kazuhiro Kurokawa, Ravi S. Jonnal, Donald T. Miller

    Cone photoreceptors undergo a daily cycle of renewal and shedding of membranous discs in their outer segments (OS), the portion responsible for light capture. These physiological processes are fundamental to maintaining photoreceptor health, and their dysfunction is associated with numerous retinal diseases. While both processes have been extensively studied in animal models and postmortem eyes, little is known about them in the living eye, in particular human. In this study, we report discovery of the optical signature associated with disc shedding using a method based on adaptive optics optical coherence tomography (AO-OCT) in conjunction with post-processing methods to track and monitor individual cone cells in 4D. The optical signature of disc shedding is characterized by an abrupt transient loss in the cone outer segment tip (COST) reflection followed by its return that is axially displaced anteriorly. Using this signature, we measured the temporal and spatial properties of shedding events in three normal subjects. Average duration of the shedding event was 8.8 ± 13.4 minutes, and average length loss of the OS was 2.1 μm (7.0% of OS length). Prevalence of cone shedding was highest in the morning (14.3%) followed by the afternoon (5.7%) and evening (4.0%), with load distributed across the imaged patch. To the best of our knowledge these are the first images of photoreceptor disc shedding in the living retina.


  • Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics

    by Omer P. Kocaoglu, Barry Cense, Ravi S. Jonnal, Qiang Wang, Sangyeol Lee, Weihua Gao, Donald T. Miller


  • Open Access

    Adaptive optics and the eye (super resolution OCT)

    by D T Miller, O P Kocaoglu, Q Wang, S Lee

    The combination of adaptive optics (AO) and optical coherence tomography (OCT) was first reported 8 years ago and has undergone tremendous technological advances since then. The technical benefits of adding AO to OCT (increased lateral resolution, smaller speckle, and enhanced sensitivity) increase the imaging capability of OCT in ways that make it well suited for three-dimensional (3D) cellular imaging in the retina. Today, AO–OCT systems provide ultrahigh 3D resolution (3 × 3 × 3 μm3) and ultrahigh speed (up to an order of magnitude faster than commercial OCT). AO–OCT systems have been used to capture volume images of retinal structures, previously only visible with histology, and are being used for studying clinical conditions. Here, we present representative examples of cellular structures that can be visualized with AO–OCT. We overview three studies from our laboratory that used ultrahigh-resolution AO–OCT to measure the cross-sectional profiles of individual bundles in the retinal nerve fiber layer; the diameters of foveal capillaries that define the terminal rim of the foveal avascular zone; and the spacing and length of individual cone photoreceptor outer segments as close as 0.5° from the fovea center.


  • 3D imaging of cone photoreceptors over extended time periods using optical coherence tomography with adaptive optics

    by Omer P. Kocaoglu, Sangyeol Lee, Ravi S. Jonnal, Qiang Wang, Ashley E. Herde, Jason Besecker, Weihua Gao, Donald T. Miller

    Optical coherence tomography with adaptive optics (AO-OCT) is a highly sensitive, noninvasive method for 3D imaging of the microscopic retina. The purpose of this study is to advance AO-OCT technology by enabling repeated imaging of cone photoreceptors over extended periods of time (days). This sort of longitudinal imaging permits monitoring of 3D cone dynamics in both normal and diseased eyes, in particular the physiological processes of disc renewal and phagocytosis, which are disrupted by retinal diseases such as age related macular degeneration and retinitis pigmentosa. For this study, the existing AO-OCT system at Indiana underwent several major hardware and software improvements to optimize system performance for 4D cone imaging. First, ultrahigh speed imaging was realized using a Basler Sprint camera. Second, a light source with adjustable spectrum was realized by integration of an Integral laser (Femto Lasers, λc=800nm, ▵λ=160nm) and spectral filters in the source arm. For cone imaging, we used a bandpass filter with λc=809nm and ▵λ=81nm (2.6 μm nominal axial resolution in tissue, and 167 KHz A-line rate using 1,408 px), which reduced the impact of eye motion compared to previous AO-OCT implementations. Third, eye motion artifacts were further reduced by custom ImageJ plugins that registered (axially and laterally) the volume videos. In two subjects, cone photoreceptors were imaged and tracked over a ten day period and their reflectance and outer segment (OS) lengths measured. High-speed imaging and image registration/dewarping were found to reduce eye motion to a fraction of a cone width (1 μm root mean square). The pattern of reflections in the cones was found to change dramatically and occurred on a spatial scale well below the resolution of clinical instruments. Normalized reflectance of connecting cilia (CC) and OS posterior tip (PT) of an exemplary cone was 54±4, 47±4, 48±6, 50±5, 56±1% and 46±4, 53±4, 52±6, 50±5, 44±1% for days #1,3,6,8,10 respectively. OS length of the same cone was 28.9, 26.4, 26.4, 30.6, and 28.1 ìm for days #1,3,6,8,10 respectively. It is plausible these changes are an optical correlate of the natural process of OS renewal and shedding.