Kang Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kang Sun has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jing Zhang
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454000, China
2 shared publications - Bingxuan Li
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454003, China
1 shared publication Jie Long
Jiaozuo Power Supply Company, State Grid Henan Electric Power Company, Jiaozuo, Henan 454000, P. R. China
1 shared publication- Jingdie Guo
Henan Polytechnic University
1 shared publication - Jingdie Guo
State Grid Jiyuan power supply company, Jiyuan 459000, China
1 shared publication Laijun Zhao
School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo, Henan 454000, P. R. China
1 shared publication
Latest Publications
- Open Access
Fault Location Method for Distribution Networks Based on SimAM-GraphSAGE-GAT
In distribution networks, traditional fault location methods have insufficient anti-interference capability and low accuracy in locating high-resistance grounding faults. To address these issues, a distribution network fault location method on the basis of SimAM-GraphSAGE-GAT is proposed. Firstly, the distribution network topology structure is converted into an adjacency matrix, and the electrical parameters of the faulty line are incorporated as node features into the graph structure of the network. Subsequently, the sampling and aggregation mechanism of GraphSAGE is used for learning node representation. Features are refined using SimAM. As a parameter-free attention mechanism, SimAM improves the ability of the model to capture important fault information. Then, the multi-head attention mechanism of GAT is introduced to enhance the representation of neighborhood relationships. Finally, GraphSAGE is utilized once again for deep aggregation, with a view to localizing faults by node classification. An IEEE 33-node distribution network model is adopted to verify the effectiveness of the algorithm in the experiment. The results show that this method can maintain high positioning accuracy even under the tested conditions, such as high-resistance grounding, noise interference, and data loss.
Open AccessFault Location Method for Distribution Networks Based on SimAM-GraphSAGE-GAT
In distribution networks, traditional fault location methods have insufficient anti-interference capability and low accuracy in locating high-resistance grounding faults. To address these issues, a distribution network fault location method on the basis of SimAM-GraphSAGE-GAT is proposed. Firstly, the distribution network topology structure is converted into an adjacency matrix, and the electrical parameters of the faulty line are incorporated as node features into the graph structure of the network. Subsequently, the sampling and aggregation mechanism of GraphSAGE is used for learning node representation. Features are refined using SimAM. As a parameter-free attention mechanism, SimAM improves the ability of the model to capture important fault information. Then, the multi-head attention mechanism of GAT is introduced to enhance the representation of neighborhood relationships. Finally, GraphSAGE is utilized once again for deep aggregation, with a view to localizing faults by node classification. An IEEE 33-node distribution network model is adopted to verify the effectiveness of the algorithm in the experiment. The results show that this method can maintain high positioning accuracy even under the tested conditions, such as high-resistance grounding, noise interference, and data loss.
- Open Access
- 25 March 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-12
FoSSA Optimization-Based SVM Classifier for the Recognition of Partial Discharge Patterns in HV Cables
In order to enhance the classification accuracy and the generalization performance of the SVM classifier in cable partial discharge (PD) pattern recognition, a firefly optimized sparrow search algorithm (FoSSA) is proposed to optimize its kernel function parameters and penalty factors. First, the Circle-Gauss hybrid mapping model is employed in the population initialization stage of the sparrow search algorithm (SSA) to eliminate the uneven population distribution of random mapping. Sparrows tend to fall into local extremums during the search process, while the firefly algorithm has a fast optimization speed and strong local search ability. Thus, a firefly disturbance is added in the sparrow search process, and the fitness value is recalculated to update the sparrow position to enhance the sparrow’s local optimization ability and accuracy. Finally, based on the SSA, a dynamic step-size strategy is adopted to make the step size dynamically decrease with the number of iterations and improve the accuracy of convergence. Six benchmark functions are employed to evaluate the optimization performance of the FoSSA quantitatively. Experiment results show that the recognition accuracy of the PD patterns using the SVM optimized by the FoSSA could reach 97.5%.
- 25 March 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-12
Open AccessFoSSA Optimization-Based SVM Classifier for the Recognition of Partial Discharge Patterns in HV Cables
In order to enhance the classification accuracy and the generalization performance of the SVM classifier in cable partial discharge (PD) pattern recognition, a firefly optimized sparrow search algorithm (FoSSA) is proposed to optimize its kernel function parameters and penalty factors. First, the Circle-Gauss hybrid mapping model is employed in the population initialization stage of the sparrow search algorithm (SSA) to eliminate the uneven population distribution of random mapping. Sparrows tend to fall into local extremums during the search process, while the firefly algorithm has a fast optimization speed and strong local search ability. Thus, a firefly disturbance is added in the sparrow search process, and the fitness value is recalculated to update the sparrow position to enhance the sparrow’s local optimization ability and accuracy. Finally, based on the SSA, a dynamic step-size strategy is adopted to make the step size dynamically decrease with the number of iterations and improve the accuracy of convergence. Six benchmark functions are employed to evaluate the optimization performance of the FoSSA quantitatively. Experiment results show that the recognition accuracy of the PD patterns using the SVM optimized by the FoSSA could reach 97.5%.
- 15 October 2021
- Published by World Scientific Pub Co Pte Ltd in International Journal of Pattern Recognition and Artificial Intelligence
- Vol. 35 (13)
Improving the Classification Rate of Insulation Defects in Power Cables by Automatic Features Extraction and Sample Augmentation of Partial Discharge Signal
Conventional pattern recognition methods employed for differentiating the types of insulation defects in power cables usually rely on the manual extraction of partial discharge features, which is inefficient and easily affected by subjective uncertainty. This work addresses this problem by proposing a new framework based on the automatic features extraction of partial discharge signal. The method first applies a sliding time window to convert partial discharge signals in the time domain into two-dimensional images that serve directly as the input to the convolutional neural networks (CNNs). Then a nonlinear encoder is employed to automatically extract the features of the partial discharge image data as the input of CNNs for classification. In addition, we address the overfitting problem associated with the few-shot by applying a deep convolutional generative adversarial network (DCGAN) to augment the original training dataset. Experimental results demonstrate the validity of the proposed algorithm; it increases the classification accuracy by 4.18% relative to that achieved with manually extracted features; the overall accuracy of the proposed algorithm training with the augmented dataset is 3.175% higher than that with the original experimental dataset.
- 15 October 2021
- Published by World Scientific Pub Co Pte Ltd in International Journal of Pattern Recognition and Artificial Intelligence
- Vol. 35 (13)
Improving the Classification Rate of Insulation Defects in Power Cables by Automatic Features Extraction and Sample Augmentation of Partial Discharge Signal
Conventional pattern recognition methods employed for differentiating the types of insulation defects in power cables usually rely on the manual extraction of partial discharge features, which is inefficient and easily affected by subjective uncertainty. This work addresses this problem by proposing a new framework based on the automatic features extraction of partial discharge signal. The method first applies a sliding time window to convert partial discharge signals in the time domain into two-dimensional images that serve directly as the input to the convolutional neural networks (CNNs). Then a nonlinear encoder is employed to automatically extract the features of the partial discharge image data as the input of CNNs for classification. In addition, we address the overfitting problem associated with the few-shot by applying a deep convolutional generative adversarial network (DCGAN) to augment the original training dataset. Experimental results demonstrate the validity of the proposed algorithm; it increases the classification accuracy by 4.18% relative to that achieved with manually extracted features; the overall accuracy of the proposed algorithm training with the augmented dataset is 3.175% higher than that with the original experimental dataset.
- Open Access
- 1 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (5) , 1641
Robust Estimation of Arrival Time of Complex Noisy Partial Discharge Pulse in Power Cables Based on Adaptive Variational Mode Decomposition
Periodic narrowband signals and white noise are the main interferences in online detection and localization of cable partial discharge (PD), however, existing research has always focused on the white noise suppression only, which is not in line with the actual scene. A novel de-noising method for effectively extracting random PD pulse from complex and strong interferences is proposed in this paper and applied to PD localization. Firstly, an improved adaptive variational mode decomposition (AVMD) is used to decompose periodic narrowband interference, white noise, and PD signal into different intrinsic mode. According to the characteristic that the power of intrinsic mode component of periodic narrowband interference in the discrete Fourier transformation (DFT) power spectrum is much larger than that of PD and white noise, the periodic narrowband is removed out. In order to effectively filter out white noise, a scale adaptive wavelet packet decomposition method based on correlation coefficient is proposed, which decomposes the signal into high, middle, and low-frequency components. The components with low frequency, small amplitude are removed out as the white noise interference according to the threshold method, and the residual is the de-noising PD signal. Experimental results show that the proposed method can robustly suppress the interference of periodic narrowband signal and white noise, and effectively preserve the essential characteristics of the real PD signal. In the multi-sensor travelling wave based localization system of cable PD source using time-varying kurtosis, accurate estimation of first arrival time of PD pulse can be achieved by the de-noising results.
- 1 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (5) , 1641
Open AccessRobust Estimation of Arrival Time of Complex Noisy Partial Discharge Pulse in Power Cables Based on Adaptive Variational Mode Decomposition
Periodic narrowband signals and white noise are the main interferences in online detection and localization of cable partial discharge (PD), however, existing research has always focused on the white noise suppression only, which is not in line with the actual scene. A novel de-noising method for effectively extracting random PD pulse from complex and strong interferences is proposed in this paper and applied to PD localization. Firstly, an improved adaptive variational mode decomposition (AVMD) is used to decompose periodic narrowband interference, white noise, and PD signal into different intrinsic mode. According to the characteristic that the power of intrinsic mode component of periodic narrowband interference in the discrete Fourier transformation (DFT) power spectrum is much larger than that of PD and white noise, the periodic narrowband is removed out. In order to effectively filter out white noise, a scale adaptive wavelet packet decomposition method based on correlation coefficient is proposed, which decomposes the signal into high, middle, and low-frequency components. The components with low frequency, small amplitude are removed out as the white noise interference according to the threshold method, and the residual is the de-noising PD signal. Experimental results show that the proposed method can robustly suppress the interference of periodic narrowband signal and white noise, and effectively preserve the essential characteristics of the real PD signal. In the multi-sensor travelling wave based localization system of cable PD source using time-varying kurtosis, accurate estimation of first arrival time of PD pulse can be achieved by the de-noising results.
- Open Access
Extraction of Partial Discharge Pulses from the Complex Noisy Signals of Power Cables Based on CEEMDAN and Wavelet Packet
While both periodic narrowband noise and white noise are significant sources of interference in the detection and localization of partial discharge (PD) signals in power cables, existing research has focused nearly exclusively on white noise suppression. This paper addresses this issue by proposing a new signal extraction method for effectively detecting random PD signals in power cables subject to complex noise environments involving both white noise and periodic narrowband noise. Firstly, the power cable signal was decomposed using complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN), and the periodic narrowband noise and frequency aliasing in the obtained signal components were suppressed using singular value decomposition. Then, signal components contributing significantly to the PD signal were determined according to the cross-correlation coefficient between each component and the original PD signal, and the PD signal was reconstructed solely from the obtained significant components. Finally, the wavelet packet threshold method was used to filter out residual white noise in the reconstructed PD signal. The performance of the proposed algorithm was demonstrated by its application to synthesized PD signals with complex noise environments composed of both Gaussian white noise and periodic narrowband noise. In addition, the time-varying kurtosis method was demonstrated to accurately determine the PD signal arrival time when applied to PD signals extracted by the proposed method from synthesized signals in complex noise environments with signal-to-noise ratio (SNR) values as low as −6 dB. When the SNR was reduced to −23 dB, the arrival time error of the PD signal was only one sampling point.
Open AccessExtraction of Partial Discharge Pulses from the Complex Noisy Signals of Power Cables Based on CEEMDAN and Wavelet Packet
While both periodic narrowband noise and white noise are significant sources of interference in the detection and localization of partial discharge (PD) signals in power cables, existing research has focused nearly exclusively on white noise suppression. This paper addresses this issue by proposing a new signal extraction method for effectively detecting random PD signals in power cables subject to complex noise environments involving both white noise and periodic narrowband noise. Firstly, the power cable signal was decomposed using complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN), and the periodic narrowband noise and frequency aliasing in the obtained signal components were suppressed using singular value decomposition. Then, signal components contributing significantly to the PD signal were determined according to the cross-correlation coefficient between each component and the original PD signal, and the PD signal was reconstructed solely from the obtained significant components. Finally, the wavelet packet threshold method was used to filter out residual white noise in the reconstructed PD signal. The performance of the proposed algorithm was demonstrated by its application to synthesized PD signals with complex noise environments composed of both Gaussian white noise and periodic narrowband noise. In addition, the time-varying kurtosis method was demonstrated to accurately determine the PD signal arrival time when applied to PD signals extracted by the proposed method from synthesized signals in complex noise environments with signal-to-noise ratio (SNR) values as low as −6 dB. When the SNR was reduced to −23 dB, the arrival time error of the PD signal was only one sampling point.
- 21 September 2017
- Published by Springer Nature
- p. 599-609
On Line Partial Discharge Localization in Cable Based on Time Varying Kurtosis and Time Window Energy Ratio
- 21 September 2017
- Published by Springer Nature
- p. 599-609
On Line Partial Discharge Localization in Cable Based on Time Varying Kurtosis and Time Window Energy Ratio