Hideaki Teshima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hideaki Teshima has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Koji Takahashi
Department of Aeronautics and Astronautics, Kyushu University, 744 Motooka, Fukuoka 819-0395, Japan
8 shared publications - Qin-Yi Li
Department of Aeronautics and Astronautics, Kyushu University, 744 Motooka, Fukuoka 819-0395, Japan
5 shared publications Koji Takahashi
Department of Aeronautics and Astronautics, Kyushu University, Nishi-Ku, Motooka 744, Fukuoka 819-0395, Japan; International Institute for Carbon-Neutral Energy Research (WPI-I2CNER), Kyushu University, Nishi-Ku, Motooka 744, Fukuoka 819-0395, Japan
3 shared publications- Masumi Misaka3 shared publications
Qin-Yi Li
3 shared publicationsHaruya Ishida
Department of Aeronautics and Astronautics, Kyushu University, Nishi-Ku, Motooka 744, Fukuoka 819-0395, Japan
2 shared publications
Latest Publications
- Open Access
- 6 October 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 273
Nanoscale surface roughness enhances wicking through closely spaced and interconnected depressions
- 6 October 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 273
Open AccessNanoscale surface roughness enhances wicking through closely spaced and interconnected depressions
- Open Access
- 5 August 2026
- Published by Wiley in Advanced Science
- Vol. 13 (60)
Drop‐Location‐Insensitive Droplet‐Based Electricity Generator Using Polydimethylsiloxane Slippery Covalently Attached Liquid Coatings
Droplet‐based electricity generators (DEGs) offer a promising strategy for harvesting untapped water energy from sources such as rain. To ensure high energy harvesting performance, droplets must contact the surface and be rapidly detached. To enable this behavior, superhydrophobic surfaces have been considered a solution. However, conventional superhydrophobic‐DEGs often face difficulties in practical applications due to non‐uniform performance caused by droplet bouncing and splitting. Here, we introduce a polydimethylsiloxane slippery covalently attached liquid (PDMS‐SCAL) coating into a DEG platform to minimize contact line pinning and droplet rebound. The PDMS‐SCAL‐DEG exhibits high open‐circuit voltage output (162.2 ± 3.8 V) and excellent performance stability across various droplet heights, incline angles, and drop locations. In drop‐location sensitivity experiments performed 14.1 mm apart from the optimum point, only a ≤25% performance degradation was observed. Experiments on a superhydrophobic‐DEG revealed that the same conditions led to a more than 92% performance degradation. Developed PDMS‐SCAL‐DEG maintains stable energy‐harvesting performance even after 10000 energy‐harvesting cycles. The reliability of PDMS‐SCAL‐DEG was also demonstrated through field testing in rainy environments. We further confirmed the comprehensive durability, including mechanical and chemical durability. This work presents a previously unexplored DEG platform with drop‐location‐insensitive characteristics to expand the scope of DEG applications.
- 5 August 2026
- Published by Wiley in Advanced Science
- Vol. 13 (60)
Open AccessDrop‐Location‐Insensitive Droplet‐Based Electricity Generator Using Polydimethylsiloxane Slippery Covalently Attached Liquid Coatings
Droplet‐based electricity generators (DEGs) offer a promising strategy for harvesting untapped water energy from sources such as rain. To ensure high energy harvesting performance, droplets must contact the surface and be rapidly detached. To enable this behavior, superhydrophobic surfaces have been considered a solution. However, conventional superhydrophobic‐DEGs often face difficulties in practical applications due to non‐uniform performance caused by droplet bouncing and splitting. Here, we introduce a polydimethylsiloxane slippery covalently attached liquid (PDMS‐SCAL) coating into a DEG platform to minimize contact line pinning and droplet rebound. The PDMS‐SCAL‐DEG exhibits high open‐circuit voltage output (162.2 ± 3.8 V) and excellent performance stability across various droplet heights, incline angles, and drop locations. In drop‐location sensitivity experiments performed 14.1 mm apart from the optimum point, only a ≤25% performance degradation was observed. Experiments on a superhydrophobic‐DEG revealed that the same conditions led to a more than 92% performance degradation. Developed PDMS‐SCAL‐DEG maintains stable energy‐harvesting performance even after 10000 energy‐harvesting cycles. The reliability of PDMS‐SCAL‐DEG was also demonstrated through field testing in rainy environments. We further confirmed the comprehensive durability, including mechanical and chemical durability. This work presents a previously unexplored DEG platform with drop‐location‐insensitive characteristics to expand the scope of DEG applications.
- Open Access
- 15 May 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (20) , 6698-6704
Hydrophobicity Does Not Affect Water Slip: Insights from Slip Length Mapping
While slip at solid-water interfaces has attracted broad interest, slip lengths reported in experiments─especially on hydrophobic surfaces (i.e., contact angles >90°)─vary widely due to surface topographical and chemical heterogeneity, hindering quantitative understanding of the true slip length. Using highly sensitive frequency-modulation atomic force microscopy, we achieved simultaneous nanoscale mapping of slip length and surface topography, with a 159-fold improvement in slip length detection sensitivity. True slip lengths measured on flat regions of various substrates were found to be almost zero, following a scaling rule predicted by molecular dynamics simulations. As the only exception, a large slip length of 43.2 ± 5.8 nm was measured on graphite in deionized water, but it vanished upon immersion in electrolyte solutions. This unique behavior was rationalized by graphite's atomic-scale smoothness, chemical homogeneity, and ion adsorption. Our method experimentally advances a unified picture of fluid slip.
- 15 May 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (20) , 6698-6704
Open AccessHydrophobicity Does Not Affect Water Slip: Insights from Slip Length Mapping
While slip at solid-water interfaces has attracted broad interest, slip lengths reported in experiments─especially on hydrophobic surfaces (i.e., contact angles >90°)─vary widely due to surface topographical and chemical heterogeneity, hindering quantitative understanding of the true slip length. Using highly sensitive frequency-modulation atomic force microscopy, we achieved simultaneous nanoscale mapping of slip length and surface topography, with a 159-fold improvement in slip length detection sensitivity. True slip lengths measured on flat regions of various substrates were found to be almost zero, following a scaling rule predicted by molecular dynamics simulations. As the only exception, a large slip length of 43.2 ± 5.8 nm was measured on graphite in deionized water, but it vanished upon immersion in electrolyte solutions. This unique behavior was rationalized by graphite's atomic-scale smoothness, chemical homogeneity, and ion adsorption. Our method experimentally advances a unified picture of fluid slip.
- Open Access
- 26 March 2026
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 28 (17) , 10645-10651
Slide electrification charge can exist without residual liquid film: KPFM measurements near receding three-phase contact lines
Kelvin probe force microscopy reveals that receding contact lines leave stable surface charge on SiO 2 even without residual liquid films or nanodroplets. A charge-relaxation extension reconciles the measured profiles using Debye-length-based theory.
- 26 March 2026
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 28 (17) , 10645-10651
Open AccessSlide electrification charge can exist without residual liquid film: KPFM measurements near receding three-phase contact lines
Kelvin probe force microscopy reveals that receding contact lines leave stable surface charge on SiO 2 even without residual liquid films or nanodroplets. A charge-relaxation extension reconciles the measured profiles using Debye-length-based theory.
- Open Access
- 10 March 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 263
Hydrophilic nanofiber alignment governs precursor film propagation
- 10 March 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 263
Open AccessHydrophilic nanofiber alignment governs precursor film propagation
- 28 December 2025
- Published by Elsevier in Applied Surface Science
- Vol. 725
Real-time observation of electrochemically generated nanobubbles and micropancakes with partial contact-line pinning
- 28 December 2025
- Published by Elsevier in Applied Surface Science
- Vol. 725
Real-time observation of electrochemically generated nanobubbles and micropancakes with partial contact-line pinning
- Open Access
- 24 December 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (1) , 917-925
Impact of Sub-Nanoscale Surface Topography on Contact Line Profile: Insights from Coherence Scanning Interferometry
Despite the importance of the effect of subnanoscale roughness on contact line behavior, it is difficult to directly observe the local behavior of contact lines at the micro- and nanoscale, leaving significant gaps in our current understanding. In this research, we investigate contact line motions and their relationship with nanoscale surface topography using coherence scanning interferometry. Our experiments were conducted on the substrates with different wettability without changing nanoscale surface topography. Titanium dioxide was used as a substrate, the wettability of which was varied under UV-light irradiation. A ridge-like structure with a height of approximately 1 nm was observed to cause contact line deformation toward the droplet side, regardless of the direction of the contact line motion. This was explained in terms of an imbalance in the local capillary pressure at the nanoscale contact line. We also found that the deformation becomes larger on the more hydrophilic surface, which was rationalized by theoretical prediction based on analysis of the work done by the force acting on the contact line and the change in surface free energy associated with the deformation of the liquid/gas interface. Furthermore, it was revealed by contact angle measurements that the maximum pinning forces on a hydrophilic surface were less than half of those on a hydrophobic surface. We attributed the weak pinning force on the hydrophilic surface to cascading depinning, where the initial depinning event triggers a chain reaction of subsequent depinning events, driven by the conversion of excess surface energy to kinetic energy. Our experimental works provide new insights of the relationship between the subnanoscale surface roughness and macroscopic contact line motion.
- 24 December 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (1) , 917-925
Open AccessImpact of Sub-Nanoscale Surface Topography on Contact Line Profile: Insights from Coherence Scanning Interferometry
Despite the importance of the effect of subnanoscale roughness on contact line behavior, it is difficult to directly observe the local behavior of contact lines at the micro- and nanoscale, leaving significant gaps in our current understanding. In this research, we investigate contact line motions and their relationship with nanoscale surface topography using coherence scanning interferometry. Our experiments were conducted on the substrates with different wettability without changing nanoscale surface topography. Titanium dioxide was used as a substrate, the wettability of which was varied under UV-light irradiation. A ridge-like structure with a height of approximately 1 nm was observed to cause contact line deformation toward the droplet side, regardless of the direction of the contact line motion. This was explained in terms of an imbalance in the local capillary pressure at the nanoscale contact line. We also found that the deformation becomes larger on the more hydrophilic surface, which was rationalized by theoretical prediction based on analysis of the work done by the force acting on the contact line and the change in surface free energy associated with the deformation of the liquid/gas interface. Furthermore, it was revealed by contact angle measurements that the maximum pinning forces on a hydrophilic surface were less than half of those on a hydrophobic surface. We attributed the weak pinning force on the hydrophilic surface to cascading depinning, where the initial depinning event triggers a chain reaction of subsequent depinning events, driven by the conversion of excess surface energy to kinetic energy. Our experimental works provide new insights of the relationship between the subnanoscale surface roughness and macroscopic contact line motion.
- Open Access
- 23 September 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 678 (Pt C) , 1230-1238
Precursor-film-driven ultra-early depinning of the three-phase contact line
- 23 September 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 678 (Pt C) , 1230-1238
Open AccessPrecursor-film-driven ultra-early depinning of the three-phase contact line
- Open Access
- 18 March 2024
- Published by Elsevier in International Journal of Thermofluids
- Vol. 22
Optimizing the methodology for accurate and accessible slip length measurement with atomic force microscopy
- 18 March 2024
- Published by Elsevier in International Journal of Thermofluids
- Vol. 22
Open AccessOptimizing the methodology for accurate and accessible slip length measurement with atomic force microscopy
- 21 January 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 46
Nano-captured water affects the wettability of cellulose nanofiber films
- 21 January 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 46
Nano-captured water affects the wettability of cellulose nanofiber films