Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiwon Choi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Jeonghun Ko

    Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea

    3 shared publications
  • Sanghoo Park

    Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea

    3 shared publications
  • Hyunseung Lee

    Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea

    2 shared publications
  • Ji Young Choi

    Center for Precision Neutrino Research (CPNR), Department of Physics, Chonnam National University , Yongbong-ro 77, Puk-gu, Gwangju 61186

    2 shared publications
  • Kyung Kwang Joo

    Center for Precision Neutrino Research (CPNR), Department of Physics, Chonnam National University , Yongbong-ro 77, Puk-gu, Gwangju 61186

    2 shared publications
  • Changmin Shin

    Department of Nuclear and Quantum Engineering Korea Advanced Institute of Science and Technology 291 Daehak‐ro Yuseong‐gu Daejeon 34141 Republic of Korea

    1 shared publication

Latest Publications

  • Optimization-based reconstruction of parameterized electron energy distribution functions from optical emission spectra in low-pressure argon plasma

    by Chunyue Huang, Changmin Shin, Jonggu Han, Jiwon Choi, Jeonghun Ko, Sanghoo Park, Se Youn Moon, Wonho Choe

    The electron energy distribution function (EEDF) is a fundamental indicator of the nonequilibrium nature of low-temperature plasmas that govern electron-driven physical and chemical processes. In this study, an optimization-based inversion framework was developed to reconstruct parameterized EEDFs, described by a generalized functional form, in lowpressure argon plasmas; these EEDFs are reconstructed from optical emission spectra. A collisional-radiative model was coupled with a genetic algorithm to determine the parameters of the adopted generalized EEDF expression by fitting the intensities of the selected emission lines. Numerical tests demonstrated that the proposed method could accurately reproduce the prescribed EEDF shapes, and it exhibited a certain degree of robustness against spectral noise. The framework was further validated experimentally in two different argon-based inductively-coupled plasma systems; the retrieved EEDFs showed good agreement with those obtained from the Langmuir probe measurements, particularly in the low-energy region. The role of the metastable-assisted stepwise excitation from the 1s manifold in enhancing the spectral sensitivity to low-energy electrons was analyzed. These results indicate that the proposed approach provides a feasible and physically consistent solution for detailed diagnostics of non-equilibrium electron kinetics in low-pressure plasmas, and its applicability and limitations are clearly defined.

  • Volumetric characterization of CCPs via 2.5-dimensional optical emission tomography

    by Hyunseung Lee, Jiwon Choi, Jeonghun Ko, Daehee Wi, Chansoo Kang, Sejin Oh, June Young Kim, Sanghoo Park

    Multidimensional diagnostics capable of mapping the in–situ, real–time characteristics of industrial plasmas remain a longstanding need. Here, we demonstrate optical emission tomography (OET) for volumetric characterization of capacitively coupled plasmas (CCPs). Using line–integrated optical intensity data, two–dimensional (2D) emission profiles parallel to the electrode surfaces are reconstructed via Phillips–Tikhonov regularization. Stacking reconstructions at multiple heights (z) above the bottom electrode yields a quasi–3D (2.5D) representation of the discharge. At a fixed 13.56 MHz radio–frequency power of 250 W, we observe significant 3D changes in plasma distribution as the working pressure is varied from 10 to 500 mTorr, including both radial and axial transitions. In particular, the radial profile evolves from center–bright, bell–shaped emission to edge-bright, hollow emission with a strong z–dependence: at z=40 mm, the edge–to–center intensity ratio [i.e., I(r=110 mm)/I(r=0 mm)] increases from ~0.4 at 10 mTorr to ~7.0 at 500 mTorr, indicating a transition from non–local to local power deposition. Furthermore, OET successfully captures point–like emission intentionally induced by a dc–biased probe tip, even in the presence of strong background plasma emission. Our results reveal that 2.5D OET enables reliable visualization of volumetric plasma behavior and offers a practical pathway toward real–time 3D, non–invasive monitoring and process control in industrial CCP reactors.


  • Ray-tracing-assisted optical emission tomography for industrial processing plasmas

    by Jiwon Choi, Hyunseung Lee, Jeonghun Ko, Sanghoo Park

    Optical emission tomography is valuable for resolving spatial variations of semiconductor processing plasmas, but in realistic reactor environments, reconstruction accuracy is often compromised by two systematic errors: (i) inaccurate detector line-of-sight information due to chamber-induced distortions (e.g. refraction) or line-of-sight measurement errors, and (ii) a projection weight matrix that does not account for internal reflections in the chamber. We report an essential calibration strategy that compensates for both effects prior to tomographic reconstruction. First, a shade-marker method with a light source determines the true position and orientation of every detector pixel. Second, a ray-tracing model implemented in COMSOL Multiphysics tracks photon trajectories from the plasma, through the quartz window, and into the detector; the resulting path densities are directly embedded into the projection weight matrix, thereby incorporating FoV distortion into the forward model. Phantom-based reconstruction tests demonstrate that neglecting FoV distortion increases the root-mean-square error (RMSE) of reconstruction by up to a factor of six, while a 2.5° detector misalignment doubles the error. Applying the proposed protocol to a 200 mm, 13.56 MHz capacitively coupled argon discharge reduces the forward-projection RMSE from 21.2 to 10.0 (52.8% reduction). This methodology is readily extensible to other plasma tools and provides a rigorous front-end for next-generation, in-situ plasma diagnostics.


  • Development of water-based liquid scintillator based on hydrophilic-lipophilic balance index

    by J W Choi, J Y Choi, K K Joo, H J Woo

    Liquid scintillator (LS) dissolves a scintillating fluor in an organic base solvent to emit light. LS emits light when it receives energy from external sources. In this study, we developed a water-based liquid scintillator (WbLS), where a surfactant was used to mix water and oil. There are various surfactants in the market, hence, finding a suitable surfactant plays an important role in synthesizing liquid scintillators using water. We performed a feasibility study on synthesizing WbLS based on the hydrophilic-lipophilic balance (HLB) index. As far as we are concerned, no literature report on the investigation of WbLS using HLB index has been found. Long-term stability is very important for the WbLS, and it needs to be observed for at least a year for any changes. Meanwhile, as an application of WbLS, sinogram analysis was performed with Radon transformation. It was possible to reconstruct transverse images with longitudinal photo images of the WbLS sample. Optical tomography was done by combining WbLS and digital camera.


  • Open Access

    Estimation of Fluor Emission Spectrum through Digital Photo Image Analysis with a Water-Based Liquid Scintillator

    by Ji-Won Choi, Ji-Young Choi, Kyung-Kwang Joo

    In this paper, we performed a feasibility study of using a water-based liquid scintillator (WbLS) for conducting imaging analysis with a digital camera. The liquid scintillator (LS) dissolves a scintillating fluor in an organic base solvent to emit light. We synthesized a liquid scintillator using water as a solvent. In a WbLS, a suitable surfactant is needed to mix water and oil together. As an application of the WbLS, we introduced a digital photo image analysis in color space. A demosaicing process to reconstruct and decode color is briefly described. We were able to estimate the emission spectrum of the fluor dissolved in the WbLS by analyzing the pixel information stored in the digital image. This technique provides the potential to estimate fluor components in the visible region without using an expensive spectrophotometer. In addition, sinogram analysis was performed with Radon transformation to reconstruct transverse images with longitudinal photo images of the WbLS sample.