In Gyu Lee
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
In Gyu Lee has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Beom-Soo Kim
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea
2 shared publications - Byung-Woo Min
Department of Orthopedic Surgery, Keimyung University School of Medicine, Daegu, Korea
2 shared publications - Kyung-Jae Lee
Department of Orthopaedic Surgery, Keimyung university Dongsan Hospital, Daegu, South Korea
2 shared publications - Chul-Hyun Cho
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Republic of Korea
1 shared publication - Chul-Hyun Cho
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, 1035 Dalgubeol-daero, Dalseo-gu, Daegu 42601, Korea
1 shared publication - Eun-Seok Son
Department of Orthopedic Surgery Keimyung University Dongsan Hospital, Keimyung University School of Medicine Daegu South Korea
1 shared publication
Latest Publications
- Open Access
- 9 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 6994
Is the Direct Fixation of Displaced Quadrilateral Plates in Acetabular Fractures Necessary?
Quadrilateral plate fractures represent a heterogeneous group of acetabular fractures. Accurate reduction is required to prevent post-traumatic arthritis. The purpose of this study is to determine the reduction effect of the direct fixation of quadrilateral plates in acetabular fractures, and to evaluate the strength of direct fixation compared to indirect fixation. Between 2005 and 2021, 49 patients underwent surgery for open reduction and internal fixation in acetabular fractures with severely displaced quadrilateral plates. Twenty-nine patients comprised the indirect fixation group, and twenty patients comprised the direct fixation group. In a comparison of primary outcome between two groups, 10 out of 29 indirect-group patients and 1 out of 20 direct-group patients developed post-traumatic osteoarthritis, wherein the difference between the two groups is statistically significant. In the assessment of postoperative Matta’s radiological reduction status, 19 out of 20 patients in the direct group had achieved anatomical and congruent reduction. The treatment using a direct reduction and internal fixation improved the reduction quality of articular displacement and offered a better survivorship of the affected hip joint.
- 9 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 6994
Open AccessIs the Direct Fixation of Displaced Quadrilateral Plates in Acetabular Fractures Necessary?
Quadrilateral plate fractures represent a heterogeneous group of acetabular fractures. Accurate reduction is required to prevent post-traumatic arthritis. The purpose of this study is to determine the reduction effect of the direct fixation of quadrilateral plates in acetabular fractures, and to evaluate the strength of direct fixation compared to indirect fixation. Between 2005 and 2021, 49 patients underwent surgery for open reduction and internal fixation in acetabular fractures with severely displaced quadrilateral plates. Twenty-nine patients comprised the indirect fixation group, and twenty patients comprised the direct fixation group. In a comparison of primary outcome between two groups, 10 out of 29 indirect-group patients and 1 out of 20 direct-group patients developed post-traumatic osteoarthritis, wherein the difference between the two groups is statistically significant. In the assessment of postoperative Matta’s radiological reduction status, 19 out of 20 patients in the direct group had achieved anatomical and congruent reduction. The treatment using a direct reduction and internal fixation improved the reduction quality of articular displacement and offered a better survivorship of the affected hip joint.
- 7 October 2022
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 931, 167502
Codoping of Al and In atoms in β-Ga2O3 semiconductors
- 7 October 2022
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 931, 167502
Codoping of Al and In atoms in β-Ga2O3 semiconductors
- Open Access
- 1 January 2021
- Published by Korean Society of Spine Surgery in Journal of Korean Society of Spine Surgery
- Vol. 28 (3) , 71-79
Morphological Features and Clinical Results of C2 Vertebral Body Fractures
- 1 January 2021
- Published by Korean Society of Spine Surgery in Journal of Korean Society of Spine Surgery
- Vol. 28 (3) , 71-79
Open AccessMorphological Features and Clinical Results of C2 Vertebral Body Fractures
- Open Access
- 22 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3758
High Failure Rates of Locking Compression Plate Osteosynthesis with Transverse Fracture around a Well-Fixed Stem Tip for Periprosthetic Femoral Fracture
This study investigated the incidence of failure after locking compression plate (LCP) osteosynthesis around a well-fixed stem of periprosthetic femoral fractures (PFFs). We retrospectively evaluated outcomes of 63 Vancouver type B1 and C PFFs treated with LCP between May 2001 and February 2018. The mean follow-up duration was 47 months. Only patients with fracture fixation with a locking plate without supplemental allograft struts were included. We identified six periprosthetic fractures of proximal Vancouver B1 fractures with spiral pattern (Group A). Vancouver B1 fractures around the stem tip were grouped into seven transverse fracture patterns (Group B) and 38 other fracture patterns such as comminuted, oblique, or spiral (Group C). Vancouver C fractures comprised 12 periprosthetic fractures with spiral, comminuted, or oblique patterns (Group D). Fracture healing without complications was achieved in all six cases in Group A, 4/7 (57%) in Group B, 35/38 (92%) in Group C, and 11/12 (92%) in Group D, respectively. The failure rates of transverse Vancouver type B1 PFFs around the stem tip were significantly different from those of Vancouver type B1/C PFFs with other patterns. For fracture with transverse pattern around the stem tip, additional fixation is necessary because LCP osteosynthesis has high failure rates.
- 22 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3758
Open AccessHigh Failure Rates of Locking Compression Plate Osteosynthesis with Transverse Fracture around a Well-Fixed Stem Tip for Periprosthetic Femoral Fracture
This study investigated the incidence of failure after locking compression plate (LCP) osteosynthesis around a well-fixed stem of periprosthetic femoral fractures (PFFs). We retrospectively evaluated outcomes of 63 Vancouver type B1 and C PFFs treated with LCP between May 2001 and February 2018. The mean follow-up duration was 47 months. Only patients with fracture fixation with a locking plate without supplemental allograft struts were included. We identified six periprosthetic fractures of proximal Vancouver B1 fractures with spiral pattern (Group A). Vancouver B1 fractures around the stem tip were grouped into seven transverse fracture patterns (Group B) and 38 other fracture patterns such as comminuted, oblique, or spiral (Group C). Vancouver C fractures comprised 12 periprosthetic fractures with spiral, comminuted, or oblique patterns (Group D). Fracture healing without complications was achieved in all six cases in Group A, 4/7 (57%) in Group B, 35/38 (92%) in Group C, and 11/12 (92%) in Group D, respectively. The failure rates of transverse Vancouver type B1 PFFs around the stem tip were significantly different from those of Vancouver type B1/C PFFs with other patterns. For fracture with transverse pattern around the stem tip, additional fixation is necessary because LCP osteosynthesis has high failure rates.