LMLukas Malena

Lukas Malena

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lukas Malena has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • David Vrba

    Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    3 shared publications
  • Jan Vrba

    Czech Technical University in Prague

    3 shared publications
  • Tomas Drizdal

    Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    3 shared publications
  • Ondrej Fiser

    Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Prague, Czech Republic

    2 shared publications
  • Dario B. Rodrigues

    University of Maryland Baltimore School of Medicine, 850 W Baltimore St, Baltimore, Baltimore, Maryland, 21201, UNITED STATES

    1 shared publication
  • David Vrba

    Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic

    1 shared publication

Latest Publications

  • Open Access

    Feasibility of Glucose Concentration Estimation in Whole Blood Samples Using Noninvasive Metamaterial Microwave Sensor

    by Lukas Malena, Ondrej Fiser, Tomas Drizdal, Tomas Pokorny, Marek Novak, Jan Vrba, David Vrba

    For a first time 20 human blood samples with varying glucose concentrations using previously introduced metamaterial microwave (MTM) sensors, which had been already tested with phantoms. The MTM sensors based on composite right/left-handed metamaterial transmission line showed a detectable phase shift in the forward transmission parameter (∠S21) which is related to the blood glucose concentration. Application of a novel biochemical approach introduces separate mathematical models based on gender, reflecting physiological difference in blood, which were further evidenced by measured variations in blood dielectric properties. This contributed to enhanced sensor performance as well as the professional sample preservation system. The accuracy of glucose concentration estimation was analyzed using mean absolute relative difference (MARD) and Parkes error grids. The MARD values for the Female and Male group reached 23 % and 29 % respectively. The findings demonstrate the potential of the MTM sensor for non-invasive glycemia monitoring.


  • Open Access

    Application of photogrammetry reconstruction for hyperthermia quality control measurements

    by Tomas Drizdal, Margarethus M. Paulides, Kemal Sumser, David Vrba, Lukas Malena, Jan Vrba, Ondrej Fiser, Gerard C. van Rhoon


  • Open Access

    Numerical Analysis of Transcranial Magnetic Stimulation Application in Patients With Orofacial Pain

    by David Vrba, Lukas Malena, Jakub Albrecht, Jitka Fricova, Martin Anders, Richard Rokyta, Dario Rodrigues, Jan Vrba

    In this paper, we monitored the accuracy of non-navigated application of repetitive Transcranial Magnetic Stimulation (rTMS) in 10 patients suffering from orofacial pain by using functional magnetic resonance (fMRI), computer modeling and numerical simulation. Through a unique process, each fMRI scan was used to define a Region of Interest (ROI) where the source of the orofacial pain was located, which was to be stimulated using rTMS. For each patient, MRI scans with a spatial resolution of 0.7 mm were converted into an anatomically accurate head model. The head model including the ROI was then co-registered with a model of the stimulation coil in an electromagnetic field numerical simulator. The accuracy of rTMS application was evaluated based on the calculations of electric field intensity distribution in the ROI. The research has yielded unique insight into ROIs (with average volume 904mm3) in patients with orofacial pain and has also extended further possibilities of human head MRI image semi-automatic segmentation. According to the calculations performed, the average ROI volume that was stimulated by an electric field with an intensity of over 80 V/m was only 4.4%, with the maximum ROI volume being 20.5%. Furthermore, a numerical study of the impact of coil rotation and translation was performed. It demonstrated a) the optimal placement of the stimulation coil can significantly increase the volume of the stimulated ROI up to 60% and b) patients with orofacial pain would need precise coil positioning with a navigation error lower than 10 mm. Due to an acceptable proccessing time of up to 6 hours, described numerical simulation opens up new options for precise rTMS treatment planning. This planning platform together withpatient-specific navigated rTMS, could lead to significant increase of treatment outcomes in patients suffering from orofacial pain.


  • Open Access

    Feasibility Evaluation of Metamaterial Microwave Sensors for Non-Invasive Blood Glucose Monitoring

    by Lukas Malena, Ondrej Fiser, Paul R. Stauffer, Tomas Drizdal, Jan Vrba, David Vrba

    The use of microwave technology is currently under investigation for non-invasive estimation of glycemia in patients with diabetes. Due to their construction, metamaterial (MTM)-based sensors have the potential to provide higher sensitivity of the phase shift of the S21 parameter (∠S21) to changes in glucose concentration compared to standard microstrip transmission line (MSTL)-based sensors. In this study, a MSTL sensor and three MTM sensors with 5, 7, and 9 MTM unit cells are exposed to liquid phantoms with different dielectric properties mimicking a change in blood glucose concentration from 0 to 14 mmol/L. Numerical models were created for the individual experiments, and the calculated S-parameters show good agreement with experimental results, expressed by the maximum relative error of 8.89% and 0.96% at a frequency of 1.99 GHz for MSTL and MTM sensor with nine unit cells, respectively. MTM sensors with an increasing number of cells show higher sensitivity of 0.62° per mmol/L and unit cell to blood glucose concentration as measured by changes in ∠S21. In accordance with the numerical simulations, the MTM sensor with nine unit cells showed the highest sensitivity of the sensors proposed by us, with an average of 3.66° per mmol/L at a frequency of 1.99 GHz, compared to only 0.48° per mmol/L for the MSTL sensor. The multi-cell MTM sensor has the potential to proceed with evaluation of human blood samples.