TPThomas W. Powers

Thomas W. Powers

*This is an algorithmically generated author record based on publicly available information.

Thomas W. Powers has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and implementation of an LC-MS-based multi-attribute method for adeno-associated virus

    by Thomas W. Powers, Shawn Mariani, Halyna Narepekha, Daniel Ryan, Savita Sankar, Thomas F. Lerch


  • Open Access

    Double-stranded RNA sequencing via RNase III E38A digestion followed by HPLC-MS/MS analysis

    by Mark Chipley, Brian Gau, Cadence Allen, Gretchen Neuschwander, Tiffany Shields, Jamie Sullivan, Thomas W. Powers

  • Open Access

    Implementing a robust platform analytical procedure for measuring adeno-associated virus vector genome titer

    by Thomas W. Powers, Courtney D.K. Sloan, Don Stano, Brad Evans, Kang Liu, Shawn Mariani, Jessica A. Campbell, Thomas F. Lerch, Jim J. Mo


  • Open Access

    Identification of Recombinant Chimpanzee Adenovirus C68 Degradation Products Detected by AEX-HPLC

    by Thomas W. Powers, Elise K. Mullins, Kun Zhang, Joseph J. Binder, Olga Friese, Herbert A. Runnels, Lawrence C. Thompson

    Physicochemical tests represent important tools for the analytical control strategy of biotherapeutics. For adenoviral modalities, anion-exchange high performance liquid chromatography (AEX-HPLC) represents an important methodology, as it is able to simultaneously provide information on viral particle concentration, product purity and surface charge in a high-throughput manner. During product development of an adenoviral-based therapeutic, an accelerated stability study was performed and showed changes in each of the AEX-HPLC reportable attributes. These changes also correlated with a decrease in product infectivity prompting a detailed characterization of the impurity and mechanism of the surface charge change. Characterization experiments identified the impurity to be free hexon trimer, suggesting that capsid degradation could be contributing to both the impurity and reduced particle concentration. Additional mass spectrometry characterization identified deamidation of specific hexon residues to be associated with the external surface charge modification observed upon thermal stress conditions. To demonstrate a causal relationship between deamidation and surface charge changes observed by AEX-HPLC, site-directed mutagenesis experiments were performed. Through this effort, it was concluded that deamidation of asparagine 414 was responsible for the surface charge alteration observed in the AEX-HPLC profile but was not associated with the reduction in infectivity. Overall, this manuscript details critical characterization efforts conducted to enable understanding of a pivotal physicochemical test for adenoviral based therapeutics.

  • Open Access

    Assessment of genome packaging in AAVs using Orbitrap-based charge-detection mass spectrometry

    by Tobias P. Wörner, Joost Snijder, Olga Friese, Thomas Powers, Albert J.R. Heck


  • Open Access

    Comparison of analytical techniques to quantitate the capsid content of adeno-associated viral vectors

    by Amanda K. Werle, Thomas W. Powers, James F. Zobel, Caitlin N. Wappelhorst, Martin F. Jarrold, Nicholas A. Lyktey, Courtney D.K. Sloan, Andrew J. Wolf, Sharee Adams-Hall, Phoebe Baldus, et al.


  • Open Access

    Quantitative analysis of genome packaging in recombinant AAV vectors by charge detection mass spectrometry

    by Lauren F. Barnes, Benjamin E. Draper, Yu-Ting Chen, Thomas W. Powers, Martin F. Jarrold


  • Open Access

    Enhancing the multi-attribute method through an automated and high-throughput sample preparation

    by Pongkwan Sitasuwan, Thomas W. Powers, Tiffany Medwid, Yuting Huang, Bradley Bare, L. Andrew Lee

    The multi-attribute method (MAM), a recent advance in the application of liquid chromatography-mass spectrometry within the pharmaceutical industry, enables the simultaneous monitoring of multiple product quality attributes in a single analytical method. While MAM is coupled with automated data processing and reporting, the sample preparation, based on proteolytic peptide mapping, remains cumbersome and low throughput. The standard sample preparation for MAM relies on protein denaturation, reduction, and alkylation prior to proteolytic digestion, but often a desalting step is required to maintain enzymatic activity. While most of the sample preparation can be automated on a standard robotic liquid handling system, a streamlined approach for protein desalting and temperature modulation is required for a viable, fully automated digestion. In this work, for the first time, a complete tip-based MAM sample preparation is automated on a single robotic liquid handling system, leveraging a deck layout that integrates both heating and cooling functionalities. The fully automated method documented herein achieves a high-throughput sample preparation for MAM, while maintaining superior method performance. Abbreviations: MAM: multi-attribute method; PQAs: product quality attributes; CE: capillary electrophoresis; IEX: ion-exchange chromatography; HILIC-FLR: hydrophilic interaction liquid chromatography coupled to a fluorescence detector; RP-LC/UV: reversed-phase liquid chromatography coupled to a UV detector; MS: mass spectrometry; NPD: new peak detection; GdnHCl: guanidine hydrochloride; TIC: total ion current; pAb: polyclonal antibody; IgG: immunoglobulin G; DTT: dithiothreitol; IAA: iodoacetic acid; TFA: trifluoroacetic acid; A280: absorbance at 280 nm wavelength; 96MPH: 96-channel multi-probe head; CPAC: Cold Plate Air Cooled; HHS: Hamilton Heater Shaker; DWP: Deep-Well Plate; PCR: Polymerase Chain Reaction; NTR: Nested Tip Rack; Met: methionine; Trp: tryptophan; N-term pQ: N-terminal glutamine cyclization; Lys: lysine; PAM: peptidylglycine α-amidating monooxygenase; G0F: asialo-, agalacto-, bi-antennary, core substituted with fucose; G1F: asialo-, mono-galactosylated bi-antennary, core substituted with fucose; G2F: asialo-, bi-galactosylated bi-antennary, core substituted with fucose; G0: asialo-, agalacto-, bi-antennary; Man5: oligomannose 5; Man8: oligomannose 8; TriF: asialo-, tri-galactosylated tri-antennary, core substituted with fucose.


  • Open Access

    Adeno-associated virus capsid assembly is divergent and stochastic

    by Tobias P. Wörner, Antonette Bennett, Sana Habka, Joost Snijder, Olga V Friese, Thomas W Powers, Mavis Agbandje-McKenna, Albert J.R. Heck

    Adeno-associated viruses (AAVs) are small, non-enveloped, and have a T=1 icosahedral capsid. They belong to the Parvoviridae , genus Dependoparvovirus . Interest in AAVs has grown over recent years as they have emerged as promising gene therapy vectors. The AAV capsid, encapsulating the transgene, consists, in total, of 60 subunits made up from three distinct viral proteins (VPs) originating from the same cap gene (VP1, VP2, and VP3), which vary only in their N-terminus. While all three VPs play a crucial and specific role in cell-entry and transduction, their exact stoichiometry and organization in AAV capsids has, despite the availability of several high-resolution structures remained elusive. Here we obtained a set of native mass spectra of intact AAV capsids (Mw ≈ 3.8 MDa) that display both highly resolved regions and regions wherein interferences occur. Through spectrum simulation we resolved and elucidated this spectral complexity, allowing us to directly assess the VP stoichiometries in a panel of serotypes from different production platforms. The data reveals an extremely heterogeneous population of capsids of variable composition. The relative abundance for each of the hundreds of co-occurring capsid compositions is accurately described by a model based upon stochastic assembly from a mixed pool of expressed VP1, VP2, and VP3. We show that even the single-most abundant VP stoichiometry represents only a few percent of the total AAV population. We estimate that virtually every AAV capsid in a particular preparation has a unique composition and arrangement, i.e . no particle is identical. The systematic scoring of the stochastic assembly model against experimental high-resolution native MS data offers a sensitive and accurate new method to characterize these exceptionally heterogeneous gene-delivery vectors.


  • Open Access

    Two-Dimensional N-Glycan Distribution Mapping of Hepatocellular Carcinoma Tissues by MALDI-Imaging Mass Spectrometry

    by Thomas W. Powers, Stephanie Holst, Manfred Wuhrer, Anand S. Mehta, Richard R. Drake

    A new mass spectrometry imaging approach to simultaneously map the two-dimensional distribution of N-glycans in tissues has been recently developed. The method uses Matrix Assisted Laser Desorption Ionization Imaging Mass Spectrometry (MALDI-IMS) to spatially profile the location and distribution of multiple N-linked glycan species released by peptide N-glycosidase F in frozen or formalin-fixed tissues. Multiple formalin-fixed human hepatocellular carcinoma tissues were evaluated with this method, resulting in a panel of over 30 N-glycans detected. An ethylation reaction of extracted N-glycans released from adjacent slides was done to stabilize sialic acid containing glycans, and these structures were compared to N-glycans detected directly from tissue profiling. In addition, the distribution of singly fucosylated N-glycans detected in tumor tissue microarray cores were compared to the histochemistry staining pattern of a core fucose binding lectin. As this MALDI-IMS workflow has the potential to be applied to any formalin-fixed tissue block or tissue microarray, the advantages and limitations of the technique in context with other glycomic methods are also summarized.