Éric Barat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Éric Barat has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Dautremer
Université Paris-Saclay CEA F-91120 Palaiseau List France
7 shared publications - Delphine Lazaro
CEA, LIST, F-91191 Gif-sur-Yvette, France
3 shared publications - Mame Diarra Fall
Institut Denis Poisson, UMR CNRS, Université d’Orléans, Orléans, France
3 shared publications - Frederic Laine
CEA, LIST, Université Paris-Saclay, Palaiseau, France
2 shared publications - Frédérick Carrel
CEA, List, Universit Paris-Saclay, Palaiseau, France
2 shared publications - Jonathan Dumazert
Universit Paris-Saclay, CEA, List, Palaiseau, France
2 shared publications
Latest Publications
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 33 (10709908) , 2230-2234
Classifier Weighted Mixture Models
This paper proposes an extension of standard mixture stochastic models, by replacing the constant mixture weights with functional weights defined using a classifier. Classifier Weighted Mixtures enable straightforward density evaluation, explicit sampling, and enhanced expressivity in variational estimation problems, without increasing the number of components nor the complexity of the mixture components.
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 33 (10709908) , 2230-2234
Classifier Weighted Mixture Models
This paper proposes an extension of standard mixture stochastic models, by replacing the constant mixture weights with functional weights defined using a classifier. Classifier Weighted Mixtures enable straightforward density evaluation, explicit sampling, and enhanced expressivity in variational estimation problems, without increasing the number of components nor the complexity of the mixture components.
- Open Access
Bregman geometry-aware split Gibbs sampling for Bayesian Poisson inverse problems
This paper proposes a novel Bayesian framework for solving Poisson inverse problems by devising a Monte Carlo sampling algorithm which accounts for the underlying non-Euclidean geometry. To address the challenges posed by the Poisson likelihood -- such as non-Lipschitz gradients and positivity constraints -- we derive a Bayesian model which leverages exact and asymptotically exact data augmentations. In particular, the augmented model incorporates two sets of splitting variables both derived through a Bregman divergence based on the Burg entropy. Interestingly the resulting augmented posterior distribution is characterized by conditional distributions which benefit from natural conjugacy properties and preserve the intrinsic geometry of the latent and splitting variables. This allows for efficient sampling via Gibbs steps, which can be performed explicitly for all conditionals, except the one incorporating the regularization potential. For this latter, we resort to a Hessian Riemannian Langevin Monte Carlo (HRLMC) algorithm which is well suited to handle priors with explicit or easily computable score functions. By operating on a mirror manifold, this Langevin step ensures that the sampling satisfies the positivity constraints and more accurately reflects the underlying problem structure. Performance results obtained on denoising, deblurring, and positron emission tomography (PET) experiments demonstrate that the method achieves competitive performance in terms of reconstruction quality compared to optimization- and sampling-based approaches.
Open AccessBregman geometry-aware split Gibbs sampling for Bayesian Poisson inverse problems
This paper proposes a novel Bayesian framework for solving Poisson inverse problems by devising a Monte Carlo sampling algorithm which accounts for the underlying non-Euclidean geometry. To address the challenges posed by the Poisson likelihood -- such as non-Lipschitz gradients and positivity constraints -- we derive a Bayesian model which leverages exact and asymptotically exact data augmentations. In particular, the augmented model incorporates two sets of splitting variables both derived through a Bregman divergence based on the Burg entropy. Interestingly the resulting augmented posterior distribution is characterized by conditional distributions which benefit from natural conjugacy properties and preserve the intrinsic geometry of the latent and splitting variables. This allows for efficient sampling via Gibbs steps, which can be performed explicitly for all conditionals, except the one incorporating the regularization potential. For this latter, we resort to a Hessian Riemannian Langevin Monte Carlo (HRLMC) algorithm which is well suited to handle priors with explicit or easily computable score functions. By operating on a mirror manifold, this Langevin step ensures that the sampling satisfies the positivity constraints and more accurately reflects the underlying problem structure. Performance results obtained on denoising, deblurring, and positron emission tomography (PET) experiments demonstrate that the method achieves competitive performance in terms of reconstruction quality compared to optimization- and sampling-based approaches.
- Open Access
- 31 May 2025
- Published by Springer Nature in Computational Statistics
- Vol. 40 (8) , 4675-4716
A simple and efficient method for sampling mixture models based on Dirichlet and Pitman-Yor processes
We introduce a simple and efficient sampling strategy for the Dirichlet process mixture model (DPM) and its two-parameter extension, the Poisson-Dirichlet process mixture model, also known as the Pitman-Yor process mixture model (PYM). Inference in DPM and PYM is typically performed using Markov Chain Monte Carlo (MCMC) methods, specifically the Gibbs sampler. These sampling methods are usually divided into two classes: marginal and conditional algorithms. Each method has its own merits and limitations. The aim of this paper is to propose a simple and effective strategy that combines the main advantages of each class. Extensive experiments on simulated and real data highlight that the proposed sampler is relevant and performs much better than its competitors.
- 31 May 2025
- Published by Springer Nature in Computational Statistics
- Vol. 40 (8) , 4675-4716
Open AccessA simple and efficient method for sampling mixture models based on Dirichlet and Pitman-Yor processes
We introduce a simple and efficient sampling strategy for the Dirichlet process mixture model (DPM) and its two-parameter extension, the Poisson-Dirichlet process mixture model, also known as the Pitman-Yor process mixture model (PYM). Inference in DPM and PYM is typically performed using Markov Chain Monte Carlo (MCMC) methods, specifically the Gibbs sampler. These sampling methods are usually divided into two classes: marginal and conditional algorithms. Each method has its own merits and limitations. The aim of this paper is to propose a simple and effective strategy that combines the main advantages of each class. Extensive experiments on simulated and real data highlight that the proposed sampler is relevant and performs much better than its competitors.
- Open Access
- 24 January 2025
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 538 (3) , 1884-1905
Nebular emission from composite star-forming galaxies – I. A novel modelling approach
We introduce a novel approach to modelling the nebular emission from star-forming galaxies by combining the contributions from many H ii regions incorporating loose trends in physical properties, random dust attenuation, a predefined H$\alpha$ luminosity function, and a diffuse ionized-gas component. Using a machine-learning-based regression artificial neural network trained on a grid of models generated by the photoionization code cloudy, we efficiently predict emission-line properties of individual H ii regions over a wide range of physical conditions. We generate 250 000 synthetic star-forming galaxies composed of up to 3000 H ii regions and explore how variations in parameters affect their integrated emission-line properties. Our results highlight systematic biases in oxygen-abundance estimates derived using traditional methods, emphasizing the importance of accounting for the composite nature of star-forming galaxies when interpreting integrated nebular emission. Future work will leverage this approach to explore in detail its impact on parameter estimates of star-forming galaxies.
- 24 January 2025
- Published by Oxford University Press (OUP) in Monthly Notices of the Royal Astronomical Society
- Vol. 538 (3) , 1884-1905
Open AccessNebular emission from composite star-forming galaxies – I. A novel modelling approach
We introduce a novel approach to modelling the nebular emission from star-forming galaxies by combining the contributions from many H ii regions incorporating loose trends in physical properties, random dust attenuation, a predefined H$\alpha$ luminosity function, and a diffuse ionized-gas component. Using a machine-learning-based regression artificial neural network trained on a grid of models generated by the photoionization code cloudy, we efficiently predict emission-line properties of individual H ii regions over a wide range of physical conditions. We generate 250 000 synthetic star-forming galaxies composed of up to 3000 H ii regions and explore how variations in parameters affect their integrated emission-line properties. Our results highlight systematic biases in oxygen-abundance estimates derived using traditional methods, emphasizing the importance of accounting for the composite nature of star-forming galaxies when interpreting integrated nebular emission. Future work will leverage this approach to explore in detail its impact on parameter estimates of star-forming galaxies.
- 11 May 2023
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM/ASA Journal on Uncertainty Quantification
- Vol. 11 (2) , 452-479
Nonparametric Posterior Learning for Emission Tomography
We continue studies of the uncertainty quantification problem in emission tomographies such as positron emission tomography (PET) or single photon emission computed tomography (SPECT) when additional multimodal data (anatomical magnetic resonance imaging (MRI) images) are available. To solve the aforementioned problem we adapt the recently proposed nonparametric posterior learning technique to the context of Poisson-type data in emission tomography. Using this approach we derive sampling algorithms which are trivially parallelizable, scalable and very easy to implement. In addition, we prove conditional consistency and tightness for the distribution of produced samples in the small noise limit (i.e., when the acquisition time tends to infinity) and derive new geometrical and necessary condition on how MRI images must be used. This condition arises naturally in the context of identifiability problem for misspecified generalized Poisson models with wrong design. We also contrast our approach with Bayesian Markov chain Monte Carlo sampling based on one data augmentation scheme which is very popular in the context of expectation-maximization algorithms for PET or SPECT. We show theoretically and also numerically that such data augmentation significantly increases mixing times for the Markov chain. In view of this, our algorithms seem to give a reasonable trade-off between design complexity, scalability, numerical load and assessment for the uncertainty.
- 11 May 2023
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM/ASA Journal on Uncertainty Quantification
- Vol. 11 (2) , 452-479
Nonparametric Posterior Learning for Emission Tomography
We continue studies of the uncertainty quantification problem in emission tomographies such as positron emission tomography (PET) or single photon emission computed tomography (SPECT) when additional multimodal data (anatomical magnetic resonance imaging (MRI) images) are available. To solve the aforementioned problem we adapt the recently proposed nonparametric posterior learning technique to the context of Poisson-type data in emission tomography. Using this approach we derive sampling algorithms which are trivially parallelizable, scalable and very easy to implement. In addition, we prove conditional consistency and tightness for the distribution of produced samples in the small noise limit (i.e., when the acquisition time tends to infinity) and derive new geometrical and necessary condition on how MRI images must be used. This condition arises naturally in the context of identifiability problem for misspecified generalized Poisson models with wrong design. We also contrast our approach with Bayesian Markov chain Monte Carlo sampling based on one data augmentation scheme which is very popular in the context of expectation-maximization algorithms for PET or SPECT. We show theoretically and also numerically that such data augmentation significantly increases mixing times for the Markov chain. In view of this, our algorithms seem to give a reasonable trade-off between design complexity, scalability, numerical load and assessment for the uncertainty.
- Open Access
Nonparametric posterior learning for emission tomography with multimodal data
We continue studies of the uncertainty quantification problem in emission tomographies such as PET or SPECT when additional multimodal data (e.g., anatomical MRI images) are available. To solve the aforementioned problem we adapt the recently proposed nonparametric posterior learning technique to the context of Poisson-type data in emission tomography. Using this approach we derive sampling algorithms which are trivially parallelizable, scalable and very easy to implement. In addition, we prove conditional consistency and tightness for the distribution of produced samples in the small noise limit (i.e., when the acquisition time tends to infinity) and derive new geometrical and necessary condition on how MRI images must be used. This condition arises naturally in the context of identifiability problem for misspecified generalized Poisson models. We also contrast our approach with Bayesian Markov Chain Monte Carlo sampling based on one data augmentation scheme which is very popular in the context of Expectation-Maximization algorithms for PET or SPECT. We show theoretically and also numerically that such data augmentation significantly increases mixing times for the Markov chain. In view of this, our algorithms seem to give a reasonable trade-off between design complexity, scalability, numerical load and assessment for the uncertainty.
Open AccessNonparametric posterior learning for emission tomography with multimodal data
We continue studies of the uncertainty quantification problem in emission tomographies such as PET or SPECT when additional multimodal data (e.g., anatomical MRI images) are available. To solve the aforementioned problem we adapt the recently proposed nonparametric posterior learning technique to the context of Poisson-type data in emission tomography. Using this approach we derive sampling algorithms which are trivially parallelizable, scalable and very easy to implement. In addition, we prove conditional consistency and tightness for the distribution of produced samples in the small noise limit (i.e., when the acquisition time tends to infinity) and derive new geometrical and necessary condition on how MRI images must be used. This condition arises naturally in the context of identifiability problem for misspecified generalized Poisson models. We also contrast our approach with Bayesian Markov Chain Monte Carlo sampling based on one data augmentation scheme which is very popular in the context of Expectation-Maximization algorithms for PET or SPECT. We show theoretically and also numerically that such data augmentation significantly increases mixing times for the Markov chain. In view of this, our algorithms seem to give a reasonable trade-off between design complexity, scalability, numerical load and assessment for the uncertainty.
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-18
A Reliable Absolute and Relative Bayesian Method for Nuclear Decommissioning: Low-Level Radioactivity Detection With Gamma-Ray Spectrometry
In this article, we aim at measuring a low-activity uranium contamination deposited on concrete surfaces of a nuclear facility and presenting varying enrichment levels. Considering this application field, CEA LIST, has developed an original approach, combining gamma-ray spectrometry based on high-purity germanium (HPGe) measurements and specific Bayesian algorithms. This methodology gives access to an indirect surface activity estimation, assuming that the ratio between the number of alpha particles to be quantified and the number of detected gamma rays is known. The Bayesian approach characteristic property is able to inject a representation of the physical context in the form of a probabilistic a priori. It enables to improve the tradeoff between the true detection rate (TDR) and the false alarm rate (FAR) at low count rates and takes benefit of a richer time-energy information structure than the algorithms used in the conventional detection procedures. The performance evaluation and characterization of Bayesian statistical tests are performed using classical receiver-operating characteristic (ROC) curves by comparison to frequentist hypothesis tests. Results indicate that the Bayesian approach has a superior detection performance for low-activity uranium contamination compared to the frequentist approach. The estimated gain is contained between 30% and 50%, considering a variable or stable radiological background. The Bayesian approach offers the best tradeoff between the TDR, FAR, and the response time and is compatible with the user's requirements.
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-18
A Reliable Absolute and Relative Bayesian Method for Nuclear Decommissioning: Low-Level Radioactivity Detection With Gamma-Ray Spectrometry
In this article, we aim at measuring a low-activity uranium contamination deposited on concrete surfaces of a nuclear facility and presenting varying enrichment levels. Considering this application field, CEA LIST, has developed an original approach, combining gamma-ray spectrometry based on high-purity germanium (HPGe) measurements and specific Bayesian algorithms. This methodology gives access to an indirect surface activity estimation, assuming that the ratio between the number of alpha particles to be quantified and the number of detected gamma rays is known. The Bayesian approach characteristic property is able to inject a representation of the physical context in the form of a probabilistic a priori. It enables to improve the tradeoff between the true detection rate (TDR) and the false alarm rate (FAR) at low count rates and takes benefit of a richer time-energy information structure than the algorithms used in the conventional detection procedures. The performance evaluation and characterization of Bayesian statistical tests are performed using classical receiver-operating characteristic (ROC) curves by comparison to frequentist hypothesis tests. Results indicate that the Bayesian approach has a superior detection performance for low-activity uranium contamination compared to the frequentist approach. The estimated gain is contained between 30% and 50%, considering a variable or stable radiological background. The Bayesian approach offers the best tradeoff between the TDR, FAR, and the response time and is compatible with the user's requirements.
- 29 June 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (14) , 5215-5252
Development and implementation in the Monte Carlo code PENELOPE of a new virtual source model for radiotherapy photon beams and portal image calculation
This work aims at developing a generic virtual source model (VSM) preserving all existing correlations between variables stored in a Monte Carlo pre-computed phase space (PS) file, for dose calculation and high-resolution portal image prediction. The reference PS file was calculated using the PENELOPE code, after the flattening filter (FF) of an Elekta Synergy 6 MV photon beam. Each particle was represented in a mobile coordinate system by its radial position (r s ) in the PS plane, its energy (E), and its polar and azimuthal angles ( d and θ d ), describing the particle deviation compared to its initial direction after bremsstrahlung, and the deviation orientation. Three sub-sources were created by sorting out particles according to their last interaction location (target, primary collimator or FF). For each sub-source, 4D correlated-histograms were built by storing E, r s , d and θ d values. Five different adaptive binning schemes were studied to construct 4D histograms of the VSMs, to ensure histogram efficient handling as well as an accurate reproduction of E, r s , d and θ d distribution details. The five resulting VSMs were then implemented in PENELOPE. Their accuracy was first assessed in the PS plane, by comparing E, r s , d and θ d distributions with those obtained from the reference PS file. Second, dose distributions computed in water, using the VSMs and the reference PS file located below the FF, and also after collimation in both water and heterogeneous phantom, were compared using a 1.5%–0 mm and a 2%–0 mm global gamma index, respectively. Finally, portal images were calculated without and with phantoms in the beam. The model was then evaluated using a 1%–0 mm global gamma index. Performance of a mono-source VSM was also investigated and led, as with the multi-source model, to excellent results when combined with an adaptive binning scheme.
- 29 June 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (14) , 5215-5252
Development and implementation in the Monte Carlo code PENELOPE of a new virtual source model for radiotherapy photon beams and portal image calculation
This work aims at developing a generic virtual source model (VSM) preserving all existing correlations between variables stored in a Monte Carlo pre-computed phase space (PS) file, for dose calculation and high-resolution portal image prediction. The reference PS file was calculated using the PENELOPE code, after the flattening filter (FF) of an Elekta Synergy 6 MV photon beam. Each particle was represented in a mobile coordinate system by its radial position (r s ) in the PS plane, its energy (E), and its polar and azimuthal angles ( d and θ d ), describing the particle deviation compared to its initial direction after bremsstrahlung, and the deviation orientation. Three sub-sources were created by sorting out particles according to their last interaction location (target, primary collimator or FF). For each sub-source, 4D correlated-histograms were built by storing E, r s , d and θ d values. Five different adaptive binning schemes were studied to construct 4D histograms of the VSMs, to ensure histogram efficient handling as well as an accurate reproduction of E, r s , d and θ d distribution details. The five resulting VSMs were then implemented in PENELOPE. Their accuracy was first assessed in the PS plane, by comparing E, r s , d and θ d distributions with those obtained from the reference PS file. Second, dose distributions computed in water, using the VSMs and the reference PS file located below the FF, and also after collimation in both water and heterogeneous phantom, were compared using a 1.5%–0 mm and a 2%–0 mm global gamma index, respectively. Finally, portal images were calculated without and with phantoms in the beam. The model was then evaluated using a 1%–0 mm global gamma index. Performance of a mono-source VSM was also investigated and led, as with the multi-source model, to excellent results when combined with an adaptive binning scheme.
- 1 December 2014
- Published by Elsevier in Physica Medica
- Vol. 30, e141
Development of a new virtual source model for portal image prediction using the Monte Carlo code penelope
- 1 December 2014
- Published by Elsevier in Physica Medica
- Vol. 30, e141
Development of a new virtual source model for portal image prediction using the Monte Carlo code penelope