Francesco Gaetano Casino
Research Subjects
Francesco Gaetano Casino has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Basile
Associazione Nefrologica Gabriella Sebastio , Martina Franca
11 shared publications - Javier Deira
Department of Nephrology, San Pedro de Alcantara Hospital, 10001 Cáceres, Spain
5 shared publications - José Aguilar
Division of Nephrology, San Pedro de Alcantara Hospital, Cáceres, Spain
3 shared publications - Mariana Murea
Department of Internal Medicine, Section on Nephrology, Wake Forest University School of Medicine, Winston-Salem, North Carolina
3 shared publications Antonio Casino
Cronos Europa , Milan
2 shared publications- Giovanni Santarsia
Division of Nephrology, Ospedale Madonna Delle Grazie, Matera, Italy
2 shared publications
Latest Publications
- 28 September 2026
- Published by Wiley in Seminars in Dialysis
- Vol. 39 (5) , 225-236
Efficacy and Safety of Incremental Hemodialysis: A Systematic Review and Meta‐Analysis
Hemodialysis, the most commonly employed renal replacement therapy in end‐stage kidney disease, prescriptions have long been standardized as thrice‐weekly at full‐dose; however, HD implementation is not without major complications. Incremental HD modalities are developed to face such one‐size‐fits‐all approach with hopes for better preservation of residual kidney function, better quality of life and patient compliance, lower complication rates, and improvements in morbidity and mortality. A comprehensive literature search was conducted through PubMed, Scopus, the Cochrane Library, Web of Science, and Ovid MEDLINE to identify relevant clinical studies on the efficacy and safety of incremental HD modalities over standard of care HD approach. We have included a total of 35 clinical studies in our final meta‐analysis. Our analysis has revealed that incremental HD approach was not associated with statistically significant improvement in all‐cause mortality, hospitalization rates, cardiovascular events, intradialytic hypotension or quality of life including mental, and physical components compared to standardized HD approach. Incremental hemodialysis was associated with better preservation of residual kidney function and lower rates of vascular access complications. Incremental hemodialysis was associated with non‐inferior clinical outcomes, better preservation of residual kidney function, and fewer vascular access complications than standard thrice‐weekly hemodialysis. Larger prospective studies with longer follow‐up are needed to support its widespread clinical use.
- 28 September 2026
- Published by Wiley in Seminars in Dialysis
- Vol. 39 (5) , 225-236
Efficacy and Safety of Incremental Hemodialysis: A Systematic Review and Meta‐Analysis
Hemodialysis, the most commonly employed renal replacement therapy in end‐stage kidney disease, prescriptions have long been standardized as thrice‐weekly at full‐dose; however, HD implementation is not without major complications. Incremental HD modalities are developed to face such one‐size‐fits‐all approach with hopes for better preservation of residual kidney function, better quality of life and patient compliance, lower complication rates, and improvements in morbidity and mortality. A comprehensive literature search was conducted through PubMed, Scopus, the Cochrane Library, Web of Science, and Ovid MEDLINE to identify relevant clinical studies on the efficacy and safety of incremental HD modalities over standard of care HD approach. We have included a total of 35 clinical studies in our final meta‐analysis. Our analysis has revealed that incremental HD approach was not associated with statistically significant improvement in all‐cause mortality, hospitalization rates, cardiovascular events, intradialytic hypotension or quality of life including mental, and physical components compared to standardized HD approach. Incremental hemodialysis was associated with better preservation of residual kidney function and lower rates of vascular access complications. Incremental hemodialysis was associated with non‐inferior clinical outcomes, better preservation of residual kidney function, and fewer vascular access complications than standard thrice‐weekly hemodialysis. Larger prospective studies with longer follow‐up are needed to support its widespread clinical use.
- 1 January 2026
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 39 (1) , 72-75
The European Renal Calculator (EuReCa) app: a user-friendly tool for calculating dialysis dose in incremental hemodialysis
Background: Incremental hemodialysis (HD) can exploit the presence of renal urea clearance (KRU) to reduce the frequency and/or dose of HD but must ensure adequate total weekly clearance, expressed as the so-called Continuous Equivalent Clearance (ECC). The aim of this study was to provide an app that could help the nephrologist prescribe dialysis parameters to achieve the appropriate ECC based on the patient's KRU. Methods: Recently, we designed a user-friendly tool for calculating dialysis dose in incremental HD which consists of a few rows of a common spreadsheet. We named it SPEEDY. It is able to provide results that are superimposable to those of Solute-Solver, the software recommended by the KDOQI clinical practice guidelines for HD adequacy. However, there were still difficulties with SPEEDY in calculating the dialysis dose to be prescribed in a timely manner. Therefore, we developed new formulas able to overcome this problem in the incremental HD setting. Results: These new formulas have been utilized to build up the European Renal Calculator (EuReCa) app, freely available at https://clearance.streamlit.app. It is intended exclusively for nephrologists treating adult patients on maintenance HD. EuReCa app is made up of five modules with related instructions for users. It allows to choose and share with the patient the prescription of treatment frequency, dialysis dose, session length, dialyzer clearance, dialyzer device, blood flow rate, ultrafiltration rate, and protein intake. Conclusion: The EuReCa app provides guidance on prescribing key HD operating parameters. Therefore, it is particularly useful for prescribing and assessing incremental HD.
- 1 January 2026
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 39 (1) , 72-75
The European Renal Calculator (EuReCa) app: a user-friendly tool for calculating dialysis dose in incremental hemodialysis
Background: Incremental hemodialysis (HD) can exploit the presence of renal urea clearance (KRU) to reduce the frequency and/or dose of HD but must ensure adequate total weekly clearance, expressed as the so-called Continuous Equivalent Clearance (ECC). The aim of this study was to provide an app that could help the nephrologist prescribe dialysis parameters to achieve the appropriate ECC based on the patient's KRU. Methods: Recently, we designed a user-friendly tool for calculating dialysis dose in incremental HD which consists of a few rows of a common spreadsheet. We named it SPEEDY. It is able to provide results that are superimposable to those of Solute-Solver, the software recommended by the KDOQI clinical practice guidelines for HD adequacy. However, there were still difficulties with SPEEDY in calculating the dialysis dose to be prescribed in a timely manner. Therefore, we developed new formulas able to overcome this problem in the incremental HD setting. Results: These new formulas have been utilized to build up the European Renal Calculator (EuReCa) app, freely available at https://clearance.streamlit.app. It is intended exclusively for nephrologists treating adult patients on maintenance HD. EuReCa app is made up of five modules with related instructions for users. It allows to choose and share with the patient the prescription of treatment frequency, dialysis dose, session length, dialyzer clearance, dialyzer device, blood flow rate, ultrafiltration rate, and protein intake. Conclusion: The EuReCa app provides guidance on prescribing key HD operating parameters. Therefore, it is particularly useful for prescribing and assessing incremental HD.
- 7 August 2025
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 41 (2) , 265-274
New formulas for calculating dialysis dose in incremental haemodialysis
Background: Interest in incremental haemodialysis (HD) is growing. The urea-based adequacy criterion of incremental HD is founded on two equivalent continuous clearances (ECC), i.e. the standard KtV (stdKt/V), which suggests a constant target (2.3 volumes/week), and the equivalent renal urea clearance (EKRU, mL/min), which suggests a variable target as a function of residual kidney urea clearance (KRU): EKRUN = 12 – KRUN, where EKRUN and KRUN are the normalized values of EKRU and KRU, expressed in units of mL/min per 35 L of urea distribution volume (V). The aim of the study was to develop new formulas that provide the dose of dialysis (eKt/V) to be prescribed to achieve the targets of the two ECCs in the incremental HD setting and validate them in a historical cohort of 202 consecutive incident HD patients. Methods: Firstly, two formulas to calculate the two ECCs (either EKRUN or stdKt/V) were obtained from computer simulation of the dialysis sessions by means of the regression analysis: ECC = a + b × KRUN + c × eKt/V + d × WFLN, where WFLN is the normalized weekly fluid loss, and a, b, c and d are the coefficients of the two formulas that predict EKRUN and stdKt/V. The coefficients change according to the treatment schedule and the ECC under evaluation. Then, the two formulas were solved to calculate the eKt/V to be prescribed to get the stdKt/V and EKRUN targets: eKt/V = (ECC target – a – b × KRUN – d × WFLN/c. Results: The stdKtV and EKRUN values estimated with the new formulas were compared with the paired ones obtained using the Solute-solver software, recommended by the Kidney Disease Outcomes Quality Initiative (KDOQI) clinical practice guidelines for HD adequacy. There was an excellent correlation between the paired values, with the regression line virtually coincident with the identity line with a squared Pearson coefficient (R2) >0.97. Conclusions: The new formulas can facilitate the implementation of incremental HD. However, it must be acknowledged that the assessment of HD adequacy cannot be based only on a single depurative index. The dialysis prescription must also take into account the clinical and metabolic status of the patient.
- 7 August 2025
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 41 (2) , 265-274
New formulas for calculating dialysis dose in incremental haemodialysis
Background: Interest in incremental haemodialysis (HD) is growing. The urea-based adequacy criterion of incremental HD is founded on two equivalent continuous clearances (ECC), i.e. the standard KtV (stdKt/V), which suggests a constant target (2.3 volumes/week), and the equivalent renal urea clearance (EKRU, mL/min), which suggests a variable target as a function of residual kidney urea clearance (KRU): EKRUN = 12 – KRUN, where EKRUN and KRUN are the normalized values of EKRU and KRU, expressed in units of mL/min per 35 L of urea distribution volume (V). The aim of the study was to develop new formulas that provide the dose of dialysis (eKt/V) to be prescribed to achieve the targets of the two ECCs in the incremental HD setting and validate them in a historical cohort of 202 consecutive incident HD patients. Methods: Firstly, two formulas to calculate the two ECCs (either EKRUN or stdKt/V) were obtained from computer simulation of the dialysis sessions by means of the regression analysis: ECC = a + b × KRUN + c × eKt/V + d × WFLN, where WFLN is the normalized weekly fluid loss, and a, b, c and d are the coefficients of the two formulas that predict EKRUN and stdKt/V. The coefficients change according to the treatment schedule and the ECC under evaluation. Then, the two formulas were solved to calculate the eKt/V to be prescribed to get the stdKt/V and EKRUN targets: eKt/V = (ECC target – a – b × KRUN – d × WFLN/c. Results: The stdKtV and EKRUN values estimated with the new formulas were compared with the paired ones obtained using the Solute-solver software, recommended by the Kidney Disease Outcomes Quality Initiative (KDOQI) clinical practice guidelines for HD adequacy. There was an excellent correlation between the paired values, with the regression line virtually coincident with the identity line with a squared Pearson coefficient (R2) >0.97. Conclusions: The new formulas can facilitate the implementation of incremental HD. However, it must be acknowledged that the assessment of HD adequacy cannot be based only on a single depurative index. The dialysis prescription must also take into account the clinical and metabolic status of the patient.
- Open Access
- 1 February 2024
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 17 (2) , sfae020
Incremental dialysis: two complementary views
Franco Casino and Mariana Murea discuss today's knowledge about the ‘incremental dialysis’ concept. Franco Casino frames the problem by saying that, in the presence of substantial residual kidney function, kidney replacement therapy can begin with low doses and/or frequencies, to be gradually increased to compensate for any subsequent losses of residual kidney function, keeping the total clearance above the minimum levels of adequacy. He remarks that studies so far have documented that this approach is safe. He recognizes that adequate randomized controlled trials (RCTs) are necessary to confirm the safety and simplify and standardize the practical aspects of this approach. Mariana Murea objects that most of the evidence gathered so far primarily derives from retrospective and observational studies, which can be influenced by socioeconomic constraints. She argues for the need for RCTs to provide compelling empirical evidence on the efficacy of incremental dialysis. Nephrologists are still reluctant to adopt this approach for various reasons, including unfamiliarity with the method, lack of practical guidance and financial disincentives. Several countries have ongoing or planned RCTs comparing incremental dialysis with conventional dialysis. These trials can shift the haemodialysis paradigm if they validate the safety and effectiveness of this approach. The moderators believe that the results of ongoing trials must be carefully interpreted, and further validation may be needed across different patient populations or healthcare settings. The ultimate goal is to gather robust evidence that could lead to widespread adoption of incremental haemodialysis, optimizing treatment, reducing overtreatment, preserving resources and improving patients’ quality of life.
- 1 February 2024
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 17 (2) , sfae020
Open AccessIncremental dialysis: two complementary views
Franco Casino and Mariana Murea discuss today's knowledge about the ‘incremental dialysis’ concept. Franco Casino frames the problem by saying that, in the presence of substantial residual kidney function, kidney replacement therapy can begin with low doses and/or frequencies, to be gradually increased to compensate for any subsequent losses of residual kidney function, keeping the total clearance above the minimum levels of adequacy. He remarks that studies so far have documented that this approach is safe. He recognizes that adequate randomized controlled trials (RCTs) are necessary to confirm the safety and simplify and standardize the practical aspects of this approach. Mariana Murea objects that most of the evidence gathered so far primarily derives from retrospective and observational studies, which can be influenced by socioeconomic constraints. She argues for the need for RCTs to provide compelling empirical evidence on the efficacy of incremental dialysis. Nephrologists are still reluctant to adopt this approach for various reasons, including unfamiliarity with the method, lack of practical guidance and financial disincentives. Several countries have ongoing or planned RCTs comparing incremental dialysis with conventional dialysis. These trials can shift the haemodialysis paradigm if they validate the safety and effectiveness of this approach. The moderators believe that the results of ongoing trials must be carefully interpreted, and further validation may be needed across different patient populations or healthcare settings. The ultimate goal is to gather robust evidence that could lead to widespread adoption of incremental haemodialysis, optimizing treatment, reducing overtreatment, preserving resources and improving patients’ quality of life.
- Open Access
- 10 January 2024
- Published by MDPI AG in Kidney and Dialysis
- Vol. 4 (1) , 27-36
One-Size-Does-Not-Fit-All: The Case of Incremental Hemodialysis
Conventional hemodialysis (HD) (a 4 h session three times a week) is not appropriate for everyone and is excessive in the presence of substantial residual kidney function (RKF). However, it can be safely replaced by a softer incremental approach guided by the urea kinetic model (UKM), starting with one or two sessions a week. Observational data suggest that RKF may be lost less quickly if dialysis is initiated less frequently than 3 times a week. Incremental HD means that, in the presence of substantial RKF, kidney replacement therapy can begin with low doses and/or frequencies, which, however, must be adequately increased to compensate for any subsequent losses of RKF, keeping the total clearance level (kidney + dialysis) always above the minimum levels of adequacy. In HD, there are complexities in combining the dialysis dose with RKF, but tools have been developed to facilitate this issue. The literature findings lend support to the safety of incremental HD and highlight the potential for this method to be implemented as a new standard of care in dialysis patients with substantial RKF. Ongoing and future trials will likely generate further evidence of the clinical and healthcare benefits of incremental HD in routine practice.
- 10 January 2024
- Published by MDPI AG in Kidney and Dialysis
- Vol. 4 (1) , 27-36
Open AccessOne-Size-Does-Not-Fit-All: The Case of Incremental Hemodialysis
Conventional hemodialysis (HD) (a 4 h session three times a week) is not appropriate for everyone and is excessive in the presence of substantial residual kidney function (RKF). However, it can be safely replaced by a softer incremental approach guided by the urea kinetic model (UKM), starting with one or two sessions a week. Observational data suggest that RKF may be lost less quickly if dialysis is initiated less frequently than 3 times a week. Incremental HD means that, in the presence of substantial RKF, kidney replacement therapy can begin with low doses and/or frequencies, which, however, must be adequately increased to compensate for any subsequent losses of RKF, keeping the total clearance level (kidney + dialysis) always above the minimum levels of adequacy. In HD, there are complexities in combining the dialysis dose with RKF, but tools have been developed to facilitate this issue. The literature findings lend support to the safety of incremental HD and highlight the potential for this method to be implemented as a new standard of care in dialysis patients with substantial RKF. Ongoing and future trials will likely generate further evidence of the clinical and healthcare benefits of incremental HD in routine practice.
- Open Access
- 26 September 2023
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 39 (3) , 445-452
Prescribing the dialysis dose and treatment frequency in home haemodialysis
Background: There is growing interest in home haemodialysis (HHD) performed with low-flow dialysate devices and variable treatment schedules. The target standard Kt/V (stdKt/V) should be 2.3 volumes/week, according to KDOQI guidelines (2015). The current formula for stdKt/V does not help prescribe the dialysis dose (eKt/V) and treatment frequency (TF). The aim of this study was to obtain a formula for stdKt/V that is able to define the minimum required values of eKt/V and TF to achieve the targeted stdKtV. Methods: Thirty-eight prevalent patients on HHD were enrolled. A total of 231 clinical datasets were available for urea modelling using the Solute-Solver software (SS), recommended by KDOQI guidelines. A new formula (stdKt/V = a + b × Kru + c × eKt/V) was obtained from multivariable regression analysis of stdKt/V vs eKt/V and residual kidney urea clearance (Kru). The values of coefficients a, b and c depend on the treatment schedules and the day of the week of blood sampling for the kinetic study (labdayofwk) and then vary for each of their foreseen 62 combinations. For practical purposes, we used only seven combinations, assuming Monday as a labdayofwk for each of the most common schedules of the 7 days of the week. Results: The stdKt/V values obtained with SS were compared with the paired ones obtained with the formula. The mean ± standard deviation stdKt/V values obtained with SS and the formula were 3.043 ± 0.530 and 2.990 ± 0.553, respectively, with 95% confidence interval +0.15 to –0.26. A ‘prescription graph’ was built using the formula to draw lines expressing the relationship between Kru and required eKt/V for each TF. Using this graph, TF could have been reduced from the delivered 5.8 ± 0.8 to 4.8 ± 0.8 weekly sessions. Conclusions: The new formula for stdKtV is reliable and can support clinicians to prescribe the dialysis dose and TF in patients undergoing HHD.
- 26 September 2023
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 39 (3) , 445-452
Open AccessPrescribing the dialysis dose and treatment frequency in home haemodialysis
Background: There is growing interest in home haemodialysis (HHD) performed with low-flow dialysate devices and variable treatment schedules. The target standard Kt/V (stdKt/V) should be 2.3 volumes/week, according to KDOQI guidelines (2015). The current formula for stdKt/V does not help prescribe the dialysis dose (eKt/V) and treatment frequency (TF). The aim of this study was to obtain a formula for stdKt/V that is able to define the minimum required values of eKt/V and TF to achieve the targeted stdKtV. Methods: Thirty-eight prevalent patients on HHD were enrolled. A total of 231 clinical datasets were available for urea modelling using the Solute-Solver software (SS), recommended by KDOQI guidelines. A new formula (stdKt/V = a + b × Kru + c × eKt/V) was obtained from multivariable regression analysis of stdKt/V vs eKt/V and residual kidney urea clearance (Kru). The values of coefficients a, b and c depend on the treatment schedules and the day of the week of blood sampling for the kinetic study (labdayofwk) and then vary for each of their foreseen 62 combinations. For practical purposes, we used only seven combinations, assuming Monday as a labdayofwk for each of the most common schedules of the 7 days of the week. Results: The stdKt/V values obtained with SS were compared with the paired ones obtained with the formula. The mean ± standard deviation stdKt/V values obtained with SS and the formula were 3.043 ± 0.530 and 2.990 ± 0.553, respectively, with 95% confidence interval +0.15 to –0.26. A ‘prescription graph’ was built using the formula to draw lines expressing the relationship between Kru and required eKt/V for each TF. Using this graph, TF could have been reduced from the delivered 5.8 ± 0.8 to 4.8 ± 0.8 weekly sessions. Conclusions: The new formula for stdKtV is reliable and can support clinicians to prescribe the dialysis dose and TF in patients undergoing HHD.
- 21 June 2023
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 36 (7) , 1965-1974
Validation of formulas calculating normalized protein catabolic rate in patients undergoing home hemodialysis
Depner and Daugirdas developed a simplified formula to estimate the normalized protein catabolic rate in patients on twice- or thrice-weekly hemodialysis (JASN, 1996). The aim of our work was to establish formulas in more frequent schedules and validate them in home-based hemodialysis patients. We realized that the structure of Depner and Daugirdas’ normalized protein catabolic rate formulas has a general meaning and can be expressed as PCRn = C0/[a + b*(Kt/V) + c/(Kt/V)] + d, where C0 is pre-dialysis blood urea nitrogen, Kt/V is dialysis dose, a, b, c, d are the specific coefficients for each combination of home-based hemodialysis schedules and the day of blood sampling. The same applies to the formula that adjusts C0 (C′0) for residual kidney clearance of blood water urea (Kru) and urea distribution volume (V): C′0 = C0*[1 + (a1 + b1/(Kt/V))*Kru/V]. On this basis, we computed the six coefficients (a, b, c, d, a1, b1) for each of the 50 possible combinations and simulated a total of 24,000 weekly dialysis cycles using the Daugirdas Solute Solver software recommended by the KDOQI 2015 guidelines. From the associated statistical analyses we obtained 50 sets of coefficient values, which were validated comparing the paired normalized protein catabolic rate values (i.e., those estimated with our formulas with those modeled with Solute Solver) in 210 datasets of 27 patients on home-based hemodialysis. The mean values ± SD were 1.06 ± 0.262 and 1.07 ± 0.283 g/kg/day, respectively, with a mean difference of 0.004 ± 0.034 g/kg/day (p = 0.11). The paired values were highly correlated (R2 = 0.99). In conclusion, even if the coefficient values were validated in a relatively small sample of patients, they allow an accurate estimation of normalized protein catabolic rate in home-based hemodialysis patients. Graphical abstract
- 21 June 2023
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 36 (7) , 1965-1974
Validation of formulas calculating normalized protein catabolic rate in patients undergoing home hemodialysis
Depner and Daugirdas developed a simplified formula to estimate the normalized protein catabolic rate in patients on twice- or thrice-weekly hemodialysis (JASN, 1996). The aim of our work was to establish formulas in more frequent schedules and validate them in home-based hemodialysis patients. We realized that the structure of Depner and Daugirdas’ normalized protein catabolic rate formulas has a general meaning and can be expressed as PCRn = C0/[a + b*(Kt/V) + c/(Kt/V)] + d, where C0 is pre-dialysis blood urea nitrogen, Kt/V is dialysis dose, a, b, c, d are the specific coefficients for each combination of home-based hemodialysis schedules and the day of blood sampling. The same applies to the formula that adjusts C0 (C′0) for residual kidney clearance of blood water urea (Kru) and urea distribution volume (V): C′0 = C0*[1 + (a1 + b1/(Kt/V))*Kru/V]. On this basis, we computed the six coefficients (a, b, c, d, a1, b1) for each of the 50 possible combinations and simulated a total of 24,000 weekly dialysis cycles using the Daugirdas Solute Solver software recommended by the KDOQI 2015 guidelines. From the associated statistical analyses we obtained 50 sets of coefficient values, which were validated comparing the paired normalized protein catabolic rate values (i.e., those estimated with our formulas with those modeled with Solute Solver) in 210 datasets of 27 patients on home-based hemodialysis. The mean values ± SD were 1.06 ± 0.262 and 1.07 ± 0.283 g/kg/day, respectively, with a mean difference of 0.004 ± 0.034 g/kg/day (p = 0.11). The paired values were highly correlated (R2 = 0.99). In conclusion, even if the coefficient values were validated in a relatively small sample of patients, they allow an accurate estimation of normalized protein catabolic rate in home-based hemodialysis patients. Graphical abstract
- 18 January 2022
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 35 (5) , 1315-1327
Does delivering more dialysis improve clinical outcomes? What randomized controlled trials have shown
Some randomized controlled trials (RCTs) have sought to determine whether different dialysis techniques, dialysis doses and frequencies of treatment are able to improve clinical outcomes in end-stage kidney disease (ESKD). Virtually all of these RCTs were enacted on the premise that ‘more’ haemodialysis might improve clinical outcomes compared to ‘conventional’ haemodialysis. Aim of the present narrative review was to analyse these landmark RCTs by posing the following question: were their intervention strategies (i.e., earlier dialysis start, higher haemodialysis dose, intensive haemodialysis, increase in convective transport, starting haemodialysis with three sessions per week) able to improve clinical outcomes? The answer is no. There are at least two main reasons why many RCTs have failed to demonstrate the expected benefits thus far: (1) in general, RCTs included relatively small cohorts and short follow-ups, thus producing low event rates and limited statistical power; (2) the designs of these studies did not take into account that ESKD does not result from a single disease entity: it is a collection of different diseases and subtypes of kidney dysfunction. Patients with advanced kidney failure requiring dialysis treatment differ on a multitude of levels including residual kidney function, biochemical parameters (e.g., acid base balance, serum electrolytes, mineral and bone disorder), and volume overload. In conclusion, the different intervention strategies of the RCTs herein reviewed were not able to improve clinical outcomes of ESKD patients. Higher quality studies are needed to guide patients and clinicians in the decision-making process. Future RCTs should account for the heterogeneity of patients when considering inclusion/exclusion criteria and study design, and should a priori consider subgroup analyses to highlight specific subgroups that can benefit most from a particular intervention. Graphical abstract
- 18 January 2022
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 35 (5) , 1315-1327
Does delivering more dialysis improve clinical outcomes? What randomized controlled trials have shown
Some randomized controlled trials (RCTs) have sought to determine whether different dialysis techniques, dialysis doses and frequencies of treatment are able to improve clinical outcomes in end-stage kidney disease (ESKD). Virtually all of these RCTs were enacted on the premise that ‘more’ haemodialysis might improve clinical outcomes compared to ‘conventional’ haemodialysis. Aim of the present narrative review was to analyse these landmark RCTs by posing the following question: were their intervention strategies (i.e., earlier dialysis start, higher haemodialysis dose, intensive haemodialysis, increase in convective transport, starting haemodialysis with three sessions per week) able to improve clinical outcomes? The answer is no. There are at least two main reasons why many RCTs have failed to demonstrate the expected benefits thus far: (1) in general, RCTs included relatively small cohorts and short follow-ups, thus producing low event rates and limited statistical power; (2) the designs of these studies did not take into account that ESKD does not result from a single disease entity: it is a collection of different diseases and subtypes of kidney dysfunction. Patients with advanced kidney failure requiring dialysis treatment differ on a multitude of levels including residual kidney function, biochemical parameters (e.g., acid base balance, serum electrolytes, mineral and bone disorder), and volume overload. In conclusion, the different intervention strategies of the RCTs herein reviewed were not able to improve clinical outcomes of ESKD patients. Higher quality studies are needed to guide patients and clinicians in the decision-making process. Future RCTs should account for the heterogeneity of patients when considering inclusion/exclusion criteria and study design, and should a priori consider subgroup analyses to highlight specific subgroups that can benefit most from a particular intervention. Graphical abstract
- 12 October 2021
- Published by Wiley in Seminars in Dialysis
- Vol. 35 (2) , 107-116
The spectrum of kidney dysfunction requiring chronic dialysis therapy: Implications for clinical practice and future clinical trials
Staging to capture kidney function and pathophysiologic processes according to severity is widely used in chronic kidney disease or acute kidney injury not requiring dialysis. Yet the diagnosis of “end‐stage kidney disease” (ESKD) considers patients as a single homogeneous group, with negligible kidney function, in need of kidney replacement therapy. Herein, we review the evidence behind the heterogeneous nature of ESKD and discuss potential benefits of recasting the terminology used to describe advanced kidney dysfunction from a monolithic entity to a disease with stages of ascending severity. We consider kidney assistance therapy in lieu of kidney replacement therapy to better reconcile all available types of therapy for advanced kidney failure including dietary intervention, kidney transplantation, and dialysis therapy at varied schedules. The lexicon “kidney dysfunction requiring dialysis” (KDRD) with stages of ascending severity based on levels of residual kidney function (RKF)—that is, renal urea clearance—and manifestations related to uremia, fluid status, and other abnormalities is discussed. Subtyping KDRD by levels of RKF could advance dialysis therapy as a form of kidney assistance therapy adjusted based on RKF and clinical symptoms. We focus on intermittent hemodialysis and underscore the need to personalize dialysis treatments and improve characterization of patients included in clinical trials.
- 12 October 2021
- Published by Wiley in Seminars in Dialysis
- Vol. 35 (2) , 107-116
The spectrum of kidney dysfunction requiring chronic dialysis therapy: Implications for clinical practice and future clinical trials
Staging to capture kidney function and pathophysiologic processes according to severity is widely used in chronic kidney disease or acute kidney injury not requiring dialysis. Yet the diagnosis of “end‐stage kidney disease” (ESKD) considers patients as a single homogeneous group, with negligible kidney function, in need of kidney replacement therapy. Herein, we review the evidence behind the heterogeneous nature of ESKD and discuss potential benefits of recasting the terminology used to describe advanced kidney dysfunction from a monolithic entity to a disease with stages of ascending severity. We consider kidney assistance therapy in lieu of kidney replacement therapy to better reconcile all available types of therapy for advanced kidney failure including dietary intervention, kidney transplantation, and dialysis therapy at varied schedules. The lexicon “kidney dysfunction requiring dialysis” (KDRD) with stages of ascending severity based on levels of residual kidney function (RKF)—that is, renal urea clearance—and manifestations related to uremia, fluid status, and other abnormalities is discussed. Subtyping KDRD by levels of RKF could advance dialysis therapy as a form of kidney assistance therapy adjusted based on RKF and clinical symptoms. We focus on intermittent hemodialysis and underscore the need to personalize dialysis treatments and improve characterization of patients included in clinical trials.
- 23 April 2021
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 34 (6) , 2009-2015
Routine assessment of kidney urea clearance, dialysis dose and protein catabolic rate in the once-weekly haemodialysis regimen
Background The dialysis dose (Kt/V) and normalized protein catabolic rate (PCRn) are the most useful indices derived from the urea kinetic model (UKM) in haemodialysis (HD) patients. The kidney urea clearance (Kru) is another important UKM parameter which plays a key role in the prescription of incremental HD. Ideally, the three kinetic parameters should be assessed using the complex software Solute Solver based on the double pool UKM. In the clinical setting, however, the three indices are estimated with simplified formulae. The recently introduced software SPEEDY assembles the aforementioned equations in a plain spreadsheet, to produce quite accurate results of Kru, Kt/V and PCRn. Unfortunately, specific equations to compute Kt/V and PCRn for patients on a once-weekly HD regimen (1HD/wk) were not available at the time SPEEDY was built-up. We devised a new version of SPEEDY (SPEEDY-1) and an even simpler variant (SPEEDY-1S), using two recently published equations for the 1HD/wk schedule . Moreover, we also added a published equation to estimate the equivalent renal clearance (EKR) normalized to urea distribution volume (V) of 35 L (EKR35) from Kru and Kt/V . Aim of the present study was to compare the results obtained using the new methods (SPEEDY-1 and SPEEDY-1S) with those provided by the reference method Solute Solver. Subjects and methods One hundred historical patients being treated with the once-weekly HD regimen were enrolled. A total of 500 HD sessions associated to the availability of monthly UKM studies were analysed in order to obtain Kru, single pool Kt/V (spKt/V), equilibrated Kt/V (eKt/V), V, PCRn and EKR35 values by using Solute Solver, SPEEDY-1 and SPEEDY-1S. Results When comparing the paired values of the above UKM parameters, as computed by SPEEDY-1 and Solute Solver, respectively, all differences but one were statistically significant at the one-sample t-test; however, the agreement limits at Bland–Altman analysis showed that all differences were negligible. When comparing the paired values of the above UKM parameters, as computed by SPEEDY-1S and Solute Solver, respectively, all differences were statistically significant; however, the agreement limits showed that the differences were negligible as far as Kru, spKt/V and eKt/V are concerned, though much larger regarding V, PCRn and EKR35. Conclusions We implemented SPEEDY with a new version specific for the once-weekly HD regimen, SPEEDY-1. It provides accurate results and is presently the best alternative to Solute Solver. Using SPEEDY-1S led to a larger difference in PCRn and EKR35, which could be acceptable for clinical practice if SPEEDY-1 is not available. Graphic abstract
- 23 April 2021
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 34 (6) , 2009-2015
Routine assessment of kidney urea clearance, dialysis dose and protein catabolic rate in the once-weekly haemodialysis regimen
Background The dialysis dose (Kt/V) and normalized protein catabolic rate (PCRn) are the most useful indices derived from the urea kinetic model (UKM) in haemodialysis (HD) patients. The kidney urea clearance (Kru) is another important UKM parameter which plays a key role in the prescription of incremental HD. Ideally, the three kinetic parameters should be assessed using the complex software Solute Solver based on the double pool UKM. In the clinical setting, however, the three indices are estimated with simplified formulae. The recently introduced software SPEEDY assembles the aforementioned equations in a plain spreadsheet, to produce quite accurate results of Kru, Kt/V and PCRn. Unfortunately, specific equations to compute Kt/V and PCRn for patients on a once-weekly HD regimen (1HD/wk) were not available at the time SPEEDY was built-up. We devised a new version of SPEEDY (SPEEDY-1) and an even simpler variant (SPEEDY-1S), using two recently published equations for the 1HD/wk schedule . Moreover, we also added a published equation to estimate the equivalent renal clearance (EKR) normalized to urea distribution volume (V) of 35 L (EKR35) from Kru and Kt/V . Aim of the present study was to compare the results obtained using the new methods (SPEEDY-1 and SPEEDY-1S) with those provided by the reference method Solute Solver. Subjects and methods One hundred historical patients being treated with the once-weekly HD regimen were enrolled. A total of 500 HD sessions associated to the availability of monthly UKM studies were analysed in order to obtain Kru, single pool Kt/V (spKt/V), equilibrated Kt/V (eKt/V), V, PCRn and EKR35 values by using Solute Solver, SPEEDY-1 and SPEEDY-1S. Results When comparing the paired values of the above UKM parameters, as computed by SPEEDY-1 and Solute Solver, respectively, all differences but one were statistically significant at the one-sample t-test; however, the agreement limits at Bland–Altman analysis showed that all differences were negligible. When comparing the paired values of the above UKM parameters, as computed by SPEEDY-1S and Solute Solver, respectively, all differences were statistically significant; however, the agreement limits showed that the differences were negligible as far as Kru, spKt/V and eKt/V are concerned, though much larger regarding V, PCRn and EKR35. Conclusions We implemented SPEEDY with a new version specific for the once-weekly HD regimen, SPEEDY-1. It provides accurate results and is presently the best alternative to Solute Solver. Using SPEEDY-1S led to a larger difference in PCRn and EKR35, which could be acceptable for clinical practice if SPEEDY-1 is not available. Graphic abstract