Raguraman C. M.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raguraman C. M. has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- C. Tara Sasanka
Department of Mechanical Engineering, R.V.R & J.C College of Engineering, Guntur, India
2 shared publications - Purushottam Karthik Janaswamy
Annamalai University Faculty of Engineering and Technology
2 shared publications
Latest Publications
- 28 November 2022
- Published by Taylor & Francis in International Journal of Coal Preparation and Utilization
- Vol. 43 (12) , 2017-2030
Investigation on pH influence for the effective transportation of coal water slurry using experimental design
The present study aims to identify the pH values in preparation of coal water slurry (CWS) that were evaluated. Rheological characteristics and stability of coal water slurry (CWS) were observed with two types of impellers at pH varying from 6.99 to 7.24. The results showed that the concentration of coal water slurry, rheological characteristics and stability of CWS for propeller and rushton impellers. The parameters that are most effected on the objectives are impeller speed (N) and ratio of clearance height with diameter of tank (C/T). The third parameter, ratio of slurry height with tank diameter (Z/T), is not effecting on output. The pH values of concentrated coal water slurry are favorable to transport to coal gasifier. For propeller impeller, the pH values vary from 6.99 to 7.15; for Rushton impeller pH values vary from 7.12 to 7.24 comparatively Rushton impeller having more base which is most favorable and obtain good CWS concentration. The influence of coal particle size is also investigated on pH values for optimal parameters of equipment.
- 28 November 2022
- Published by Taylor & Francis in International Journal of Coal Preparation and Utilization
- Vol. 43 (12) , 2017-2030
Investigation on pH influence for the effective transportation of coal water slurry using experimental design
The present study aims to identify the pH values in preparation of coal water slurry (CWS) that were evaluated. Rheological characteristics and stability of coal water slurry (CWS) were observed with two types of impellers at pH varying from 6.99 to 7.24. The results showed that the concentration of coal water slurry, rheological characteristics and stability of CWS for propeller and rushton impellers. The parameters that are most effected on the objectives are impeller speed (N) and ratio of clearance height with diameter of tank (C/T). The third parameter, ratio of slurry height with tank diameter (Z/T), is not effecting on output. The pH values of concentrated coal water slurry are favorable to transport to coal gasifier. For propeller impeller, the pH values vary from 6.99 to 7.15; for Rushton impeller pH values vary from 7.12 to 7.24 comparatively Rushton impeller having more base which is most favorable and obtain good CWS concentration. The influence of coal particle size is also investigated on pH values for optimal parameters of equipment.
- 15 October 2021
- Published by Taylor & Francis in International Journal of Coal Preparation and Utilization
- Vol. 42 (12) , 3637-3654
Optimization of process parameters for preparation of coal water slurry using ant colony optimization and hydrodynamic simulation
The Ant Colony Optimization algorithm is one of the leading optimization algorithms for nondeterministic polynomial hard problems. The aim of the present work is to find the maximum power of the agitator and selection of the motor power load for agitation equipment by assuming 80% of the maximum power of the agitator for preparation of coal water slurry. The parameters considered for optimization are the particle diameter of solids, jacketed vessel diameter and height, and density of the slurry. They affect the mass ratio and viscosity of the slurry. Sensitivity analysis was conducted with various combinations of ants’ parameters to enhance the result. From the optimization result, the power of the propeller, paddle, and rushton impellers is 13.58 Watts, 54.34 Watts, and 108.67 Watts. The power of the rushton impeller compared with the that of propeller and paddle is around 87.5% and 49%. VisiMix software is used to predict the turbulent shear near the impeller with optimized parameters obtained from ACO. The turbulent shear stress of the rushton impeller of 18.9 N/mm2 is high when compared with the other impellers. The developed algorithm has been justified with standard formulation and found to be satisfactory for implementing maximum power in agitation for uniform suspension to improve heat transfer.
- 15 October 2021
- Published by Taylor & Francis in International Journal of Coal Preparation and Utilization
- Vol. 42 (12) , 3637-3654
Optimization of process parameters for preparation of coal water slurry using ant colony optimization and hydrodynamic simulation
The Ant Colony Optimization algorithm is one of the leading optimization algorithms for nondeterministic polynomial hard problems. The aim of the present work is to find the maximum power of the agitator and selection of the motor power load for agitation equipment by assuming 80% of the maximum power of the agitator for preparation of coal water slurry. The parameters considered for optimization are the particle diameter of solids, jacketed vessel diameter and height, and density of the slurry. They affect the mass ratio and viscosity of the slurry. Sensitivity analysis was conducted with various combinations of ants’ parameters to enhance the result. From the optimization result, the power of the propeller, paddle, and rushton impellers is 13.58 Watts, 54.34 Watts, and 108.67 Watts. The power of the rushton impeller compared with the that of propeller and paddle is around 87.5% and 49%. VisiMix software is used to predict the turbulent shear near the impeller with optimized parameters obtained from ACO. The turbulent shear stress of the rushton impeller of 18.9 N/mm2 is high when compared with the other impellers. The developed algorithm has been justified with standard formulation and found to be satisfactory for implementing maximum power in agitation for uniform suspension to improve heat transfer.