Caiser Bravo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Caiser Bravo has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
A. Irani
Illinois Institute of Technology
1 shared publicationA.S. Erickson
Georgia Institute of Technology
1 shared publication- Alexander McSpaden
Los Alamos National Laboratory
1 shared publication - Alireza Haghighat
Virginia Tech
1 shared publication - Andrew J. Conant
Oak Ridge National Laboratory
1 shared publication - Bryce R. Littlejohn
Illinois Institute of Technology, Chicago, IL (United States)
1 shared publication
Latest Publications
- 7 November 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (5) , 054023
Prototype reactor-antineutrino detector based on 6 Li -doped pulse-shape-discriminating plastic scintillator
An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 ${}^{6}\mathrm{Li}$-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with ${}^{6}\mathrm{Li}$ at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-$\ensuremath{\beta}$-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. This paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.- 7 November 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (5) , 054023
Prototype reactor-antineutrino detector based on 6 Li -doped pulse-shape-discriminating plastic scintillator
An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 ${}^{6}\mathrm{Li}$-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with ${}^{6}\mathrm{Li}$ at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-$\ensuremath{\beta}$-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. This paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.- Open Access
- 14 October 2021
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 195 (sup1) , S55-S79
A New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC
The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.
- 14 October 2021
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 195 (sup1) , S55-S79
Open AccessA New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC
The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.