MKMijin Kim

Mijin Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mijin Kim has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Systematic Analysis of Driving Modes and NiFe Layer Thickness in Planar Hall Magnetoresistance Sensors

    by Changyeop Jeon, Mijin Kim, Jinwoo Kim, Sunghee Yang, Eunseo Choi, Byeonghwa Lim

    Planar Hall magnetoresistance (PHMR) sensors are widely utilized due to their high sensitivity, simple structure, and cost-effectiveness. However, their performance is influenced by both the driving mode and the thickness of the ferromagnetic layer, yet the combined effects of these factors remain insufficiently explored. This study systematically investigates the impact of Ni80Fe20 thickness (5–35 nm) on PHMR sensor performance under constant current (CC) and constant voltage (CV) modes, with a focus on optimizing the peak-to-peak voltage (Vp-p). In CC mode, electron surface scattering at 5–10 nm increases resistance, leading to a sharp rise in Vp-p, followed by a decline as the thickness increases. In contrast, CV mode minimizes resistance-related effects, with sensor signals predominantly governed by magnetization-dependent resistivity. Experimentally, the optimal Vp-p was observed at 25 nm in CV mode. However, for thicknesses beyond this point, the reduction in sensor resistance suggests that voltage distribution across both the sensor and external load resistance significantly influences performance. These findings provide practical insights into optimizing PHMR sensors by elucidating the interplay between driving modes and material properties. The results contribute to the advancement of high-performance PHMR sensors with enhanced signal stability and sensitivity for industrial and scientific applications.


  • Open Access

    Operational Parameters for Sub-Nano Tesla Field Resolution of PHMR Sensors in Harsh Environments

    by Taehyeong Jeon, Proloy Taran Das, Mijin Kim, Changyeop Jeon, Byeonghwa Lim, Ivan Soldatov, CheolGi Kim

    The resolution of planar-Hall magnetoresistive (PHMR) sensors was investigated in the frequency range from 0.5 Hz to 200 Hz in terms of its sensitivity, average noise level, and detectivity. Analysis of the sensor sensitivity and voltage noise response was performed by varying operational parameters such as sensor geometrical architectures, sensor configurations, sensing currents, and temperature. All the measurements of PHMR sensors were carried out under both constant current (CC) and constant voltage (CV) modes. In the present study, Barkhausen noise was revealed in 1/f noise component and found less significant in the PHMR sensor configuration. Under measured noise spectral density at optimized conditions, the best magnetic field detectivity was achieved better than 550 pT/√Hz at 100 Hz and close to 1.1 nT/√Hz at 10 Hz for a tri-layer multi-ring PHMR sensor in an unshielded environment. Furthermore, the promising feasibility and possible routes for further improvement of the sensor resolution are discussed.


  • Highly Bendable Planar Hall Resistance Sensor

    by Mijin Kim, Sunjong Oh, Wooseong Jeong, Artem Talantsev, Taehyeong Jeon, Richa Chaturvedi, Sungwon Lee, Cheolgi Kim

    A set of Planar Hall Resistance (PHR) sensors has been fabricated on rigid and flexible substrates. High signal-to-noise ratio, low offset voltage, nearly zero hysteresis of signal and excellent linearity has been demonstrated for sensors, based on Ta (5 nm)/NiFe (10 nm)/IrMn (10 nm)/Ta (5 nm) thin films, grown on PDMS and Parylene C polymeric substrates. Effect of bending on the performance of the PHR sensors has been studied. The effect of bending deformation on the performance characteristics of the fabricated PHR sensors is reversible until the bending angle reaches a critical one. The critical bending angle is shown to be dependent on the substrate composition. An irreversible deformation of sensor's film, accompanied by the formation of wrinkles and cracks, occurs when the bending angle exceeds the critical one. This deformation originates from the difference between the values of Young's modulus of the substrate and the film. The bending stability of PHR sensor, grown on PDMS substrate, has been improved by deposition of 1 μm of Parylene C both as a buffer and as a capping layer. The performance characteristics of the designed shapeable PHR sensors are compatible with requirements for applications in wearable electronics and medical diagnostic devices.