RKRupert Kellner

Rupert Kellner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rupert Kellner has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Retrospective analysis of clinical laboratory parameters in Han Wistar rat controls

    by Rupert Kellner, Alexander Amberg, Frank Bringezu, Dragomir Ivanov Draganov, Annika Kreuchwig, Wolfgang Muster, Guillemette Duchateau-Nguyen, Nils Oberhauser, Paolo Piraino, Markus Schaefer, et al.

    Introduction: Despite the availability of control animal data sets from toxicological studies, the influence of external factors, such as age of animals, test site and study conditions, on clinical laboratory parameters in rats is only sparsely characterized. Objective: In order to analyze the covariates of study design, we leveraged the largest available curated collection of control animal data from toxicological studies, sourced from five European pharmaceutical companies. We investigated the influence of external factors on commonly measured clinical chemistry, enzyme activity and hematology parameters in Han Wistar rats of both sexes. Materials and Methods: 457,605 control group clinical laboratory data points from 1,288 legacy toxicity studies on Han Wistar rats were curated and analyzed by ANOVA and partial eta squared to discern their effect sizes. Results: Our analysis revealed that bodyweight, used as a surrogate for age in rats, significantly influences some parameters, while demonstrating stability in others. Descriptive statistics and tolerance intervals are provided for 20-g body weight class intervals. The effect size of these body weight classes, as calculated by partial eta squared, is large for parameters that change during development (e.g., phosphate or alkaline phosphatase) but was negligible for more stable parameters (e.g., calcium and alanine aminotransferase). For parameters which are less dependent on body weight class, the relative influence of other factors, namely, the company providing the study data, as well as study year is more prominent. These factors likely act as summary factors for various influences such as changes in analytical protocols, diet or housing conditions. Conclusion: This analysis provides a comprehensive overview of parameter variability and offers critical guidance for parameters which need to be controlled when utilizing historical control data to establish reference intervals or generate virtual control groups.


  • Open Access

    Medical device similarity analysis: a promising approach to medical device equivalence regulation

    by Jan Sündermann, Joaquin Delgado Fernandez, Rupert Kellner, Theodor Doll, Ulrich P. Froriep, Annette Bitsch

    Background: This study aims to facilitate the identification of similar devices for both, the European Medical Device Regulation (MDR) and the US 510(k) equivalence pathway by leveraging existing data. Both are related to the regulatory pathway of read across for chemicals, where toxicological data from a known substance is transferred to one under investigation, as they aim to streamline the accreditation process for new devices and chemicals. Research design and methods: This study employs latent semantic analysis to generate similarity values, harnessing the US Food and Drug Administration 510k-database, utilizing their 'Device Descriptions' and 'Intended Use' statements. Results: For the representative inhaler cluster, similarity values up to 0.999 were generated for devices within a 510(k)-predicate tree, whereas values up to 0.124 were gathered for devices outside this group. Conclusion: Traditionally, MDR equivalence involves manual review of many devices, which is laborious. However, our results suggest that the automated calculation of similarity coefficients streamlines this process, thus reducing regulatory effort, which can be beneficial for patients needing medical devices. Although this study is focused on the European perspective, it can find application within 510(k) equivalence regulation. The conceptual approach is reminiscent of chemical fingerprint similarity analysis employed in read-across. Plain Language Summary This study addresses improvement of the registration process for medical devices by using automated methods to determine how similar they are to existing devices. Such a process is already used in chemistry for analysis of related substances. In the context of Medical Device Regulation (MDR), which sets standards for these devices, this process might be applicable in device equivalence evaluation. Traditionally, proving equivalence involves manually finding devices that are similar, but this is time-consuming, repetitive and labor-intensive. This study proposes a new approach, using advanced computer methods and a database from the US Food and Drug Administration (FDA) to automatically identify similar devices. This could make the process much quicker and more accurate and furthermore reduce bias. The study suggests that by applying these automated methods, the impact of recent regulatory changes could be reduced. This means that proving equivalence, a critical step to facilitate device accreditation, could be done more efficiently. The study shows potential for a significant transformation in compliance processes within the medical device industry, making them more streamlined and automated.


  • Open Access

    The effect of radiofrequency electromagnetic fields (RF-EMF) on biomarkers of oxidative stress in vivo and in vitro: A protocol for a systematic review

    by Bernd Henschenmacher, Annette Bitsch, Tonia de Las Heras Gala, Henry Jay Forman, Athanassios Fragoulis, Pietro Ghezzi, Rupert Kellner, Wolfgang Koch, Jens Kuhne, Dmitrij Sachno, et al.


  • Open Access

    Stadium‐specific transmission of endosymbionts needed for pederin biosynthesis in three species of Paederus rove beetles

    by Rupert L. L. Kellner

    Females of the rove beetle genus Paederus (Coleoptera: Staphylinidae) accumulate large amounts of the defensive compound pederin produced by an endosymbiotic bacterium. Pederin is transferred in the eggs, while the endosymbionts are transmitted via the egg shell. In all three species analyzed (P. melanurus, P. riparius, and P. sabaeus), descendants of aposymbiotic matrilines (lacking both endosymbionts and biosynthetic capabilities) acquire biosynthetic capability by the ingestion of eggs with endosymbionts during larval development. Successful colonization by endosymbionts depends on the number of eggs consumed and the age of the feeding larvae. During the adult stage, however, the females cannot acquire biosynthetic capabilities. Adult females are able to sequester pederin from eggs eaten, and they transfer the substance into their own eggs. Lack of intrinsic biosynthesis after ingestion of endosymbionts indicates that these are not biosynthetically active within the gut and have to reach an unknown internal location before completion of metamorphosis. These results are discussed with regard to the benefit of intraspecific cannibalism.