Julien J. H. Cotelesage
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julien J. H. Cotelesage has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Graham N. George
University of Saskatchewan 114 Science Place
2 shared publications - Ingrid J. Pickering
University of Saskatchewan 114 Science Place
2 shared publications - Linda Vogt
Department of Geological Sciences, University of Saskatchewan
2 shared publications - Albert E. Butterfield
Chevron Energy Technology Company, Richmond, CA 94802, USA
1 shared publication - Ben Huntsman
University of Saskatchewan
1 shared publication - Charles James Titus
Stanford University
1 shared publication
Latest Publications
- Open Access
- 31 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Importance of self-absorption correction for HERFD-XAS of concentrated samples
High energy resolution fluorescence detected X-ray absorption spectroscopy (HERFD-XAS) can dramatically reduce core-hole lifetime broadening that smears out spectroscopic detail in conventional X-ray absorption spectroscopy (XAS). This increased spectroscopic resolution can directly translate to increased speciation capabilities in analysis of complex mixtures. However, spectral distortions due to fluorescence self-absorption are inherent in the HERFD-XAS method and can negate improvements. We discuss a method for correcting self-absorption.
- 31 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessImportance of self-absorption correction for HERFD-XAS of concentrated samples
High energy resolution fluorescence detected X-ray absorption spectroscopy (HERFD-XAS) can dramatically reduce core-hole lifetime broadening that smears out spectroscopic detail in conventional X-ray absorption spectroscopy (XAS). This increased spectroscopic resolution can directly translate to increased speciation capabilities in analysis of complex mixtures. However, spectral distortions due to fluorescence self-absorption are inherent in the HERFD-XAS method and can negate improvements. We discuss a method for correcting self-absorption.
- 18 October 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1845-1849
Oxygen K-edge X-ray absorption spectra of liquids with minimization of window contamination
Oxygen K-edge X-ray absorption spectroscopy is used routinely to study a range of solid materials. However, liquid samples are studied less frequently at the oxygen K-edge due to the combined challenges of high-vacuum conditions and oxygen contamination of window materials. A modular sample holder design with a twist-seal sample containment system that provides a simple method to encapsulate liquid samples under high-vacuum conditions is presented. This work shows that pure silicon nitride windows have lower oxygen contamination than both diamond- and silicon-rich nitride windows, that the levels of oxygen contamination are related to the age of the windows, and provides a protocol for minimizing the background oxygen contamination. Acid-washed 100 nm-thick silicon nitride windows were found to give good quality oxygen K-edge data on dilute liquid samples.
- 18 October 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1845-1849
Oxygen K-edge X-ray absorption spectra of liquids with minimization of window contamination
Oxygen K-edge X-ray absorption spectroscopy is used routinely to study a range of solid materials. However, liquid samples are studied less frequently at the oxygen K-edge due to the combined challenges of high-vacuum conditions and oxygen contamination of window materials. A modular sample holder design with a twist-seal sample containment system that provides a simple method to encapsulate liquid samples under high-vacuum conditions is presented. This work shows that pure silicon nitride windows have lower oxygen contamination than both diamond- and silicon-rich nitride windows, that the levels of oxygen contamination are related to the age of the windows, and provides a protocol for minimizing the background oxygen contamination. Acid-washed 100 nm-thick silicon nitride windows were found to give good quality oxygen K-edge data on dilute liquid samples.