Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lijian Chen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Safe Design of a Hydrogen-Powered Ship: CFD Simulation on Hydrogen Leakage in the Fuel Cell Room

    by Wenfeng Guan, Ju Chen, Lijian Chen, Jiaolong Cao, Hongjun Fan

    Adopting proton exchange membrane fuel cells fuelled by hydrogen presents a promising solution for the shipping industry’s deep decarbonisation. However, the potential safety risks associated with hydrogen leakage pose a significant challenge to the development of hydrogen-powered ships. This study examines the safe design principles and leakage risks of the hydrogen gas supply system of China’s first newbuilt hydrogen-powered ship. This study utilises the computational fluid dynamics tool FLACS to analyse the hydrogen dispersion behaviour and concentration distributions in the hydrogen fuel cell room based on the ship’s parameters. This study predicts the flammable gas cloud and time points when gas monitoring points first reach the hydrogen volume concentrations of 0.8% and 1.6% in various leakage scenarios, including four different diameters (1, 3, 5, and 10 mm) and five different directions. This study’s findings indicate that smaller hydrogen pipeline diameters contribute to increased hydrogen safety. Specifically, in the hydrogen fuel cell room, a single-point leakage in a hydrogen pipeline with an inner diameter not exceeding 3 mm eliminates the possibility of flammable gas cloud explosions. Following a 10 mm leakage diameter, the hydrogen concentration in nearly all room positions reaches 4.0% within 6 s of leakage. While the leakage diameter does not impact the location of the monitoring point that first activates the hydrogen leak alarm and triggers an emergency hydrogen supply shutdown, the presence of obstructions near hydrogen detectors and the leakage direction can affect it. These insights provide guidance on the optimal locations for hydrogen detectors in the fuel cell room and the pipeline diameters on hydrogen gas supply systems, which can facilitate the safe design of hydrogen-powered ships.


  • Open Access

    Safety Design and Engineering Solution of Fuel Cell Powered Ship in Inland Waterway of China

    by Lijian Chen, Wenfeng Guan

    From the perspective of risk control, when hydrogen fuel and fuel cells are used on ships, there is a possibility of low-flash fuel leakage, leading to the risk of explosion. Since the fuel cell space (cabin for fuel cell installations) is an enclosed space, any small amount of leakage must be handled properly. In ship design, area classification is a method of analyzing and classifying the areas where explosive gas atmospheres may occur. If the fuel cell space is regarded as a hazardous area, all the electrical devices inside it must be explosion-proof type, which will make the ship’s design very difficult. This paper takes a Chinese fuel cell powered ship as an example to analyze its safety. Firstly, the leakage rates of fuel cell modules, valves, and connectors are calculated. Secondly, the IEC60079-10-1 algorithm is used to calculate the risk level of the fuel cell space. Finally, the ship and fuel cells are optimized and redesigned, and the risk level of the fuel cell space is recalculated and compared. The result shows that the optimized fuel space risk level could be reduced to the level of the non-hazardous zone.