Elia Landi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elia Landi has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Ada Fort
University of Siena
20 shared publications - Marco Mugnaini
University of Siena
20 shared publications - Valerio Vignoli
University of Siena
14 shared publications - Riccardo Moretti
Department of Information Engineering and Mathematics, University of Siena, Siena, Italy
7 shared publications - Lorenzo Parri
Department of Information Engineering and Mathematics, University of Siena, Siena, Italy
6 shared publications - Enza Panzardi
University of Siena
4 shared publications
Latest Publications
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-15
Optimized Embedded QCM-D System Based on FPGA
This work presents a low-cost Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) system implemented on a Field Programmable Gate Array (FPGA) platform. The design optimizes the trade-off between measurement accuracy and system complexity by improving the analog front-end, signal acquisition, and digital signal processing stages. A short-circuit current readout configuration minimizes the effects of parasitic capacitances and load resistance, ensuring that the measured transient depends only on the electromechanical behavior of the resonator. The system employs a Direct Digital Synthesizer (DDS)-driven mixing stage for down-conversion to baseband, followed by adaptive processing on the FPGA, which extracts the resonance frequency and dissipation factor with high precision. In addition to the system implementation, the paper includes an analysis of the main measurement errors and uncertainty sources, providing a systematic framework to assess the overall metrological performance of this type of architecture. Experimental results demonstrate frequency errors in the parts-per-million (ppm) range and dissipation errors on the order of 10⁻³, confirming that accurate and repeatable QCM-D measurements can be achieved using compact and cost-effective FPGA-based instrumentation suitable for both laboratory and portable applications.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-15
Optimized Embedded QCM-D System Based on FPGA
This work presents a low-cost Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) system implemented on a Field Programmable Gate Array (FPGA) platform. The design optimizes the trade-off between measurement accuracy and system complexity by improving the analog front-end, signal acquisition, and digital signal processing stages. A short-circuit current readout configuration minimizes the effects of parasitic capacitances and load resistance, ensuring that the measured transient depends only on the electromechanical behavior of the resonator. The system employs a Direct Digital Synthesizer (DDS)-driven mixing stage for down-conversion to baseband, followed by adaptive processing on the FPGA, which extracts the resonance frequency and dissipation factor with high precision. In addition to the system implementation, the paper includes an analysis of the main measurement errors and uncertainty sources, providing a systematic framework to assess the overall metrological performance of this type of architecture. Experimental results demonstrate frequency errors in the parts-per-million (ppm) range and dissipation errors on the order of 10⁻³, confirming that accurate and repeatable QCM-D measurements can be achieved using compact and cost-effective FPGA-based instrumentation suitable for both laboratory and portable applications.
- Open Access
- 12 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (3) , 349
Modeling and Design of a Soft Capacitive Slip Sensor with Fluid Dielectric Interlayer
This paper presents the design, modeling, and experimental validation of a capacitive tactile sensor specifically conceived to sense shear-driven contact dynamics in robotic manipulation. The proposed device is a layered flexible capacitive structure, in which controlled tangential interactions are induced. The electrode design maximizes sensitivity to shear motion and promotes an isotropic response with respect to slip direction, thereby addressing two key limitations that affect the majority of existing slip-sensing technologies. An analytical model was developed to describe the essential relationship between shear-induced displacements and the electrical response, providing insight into the design parameters and supporting the selection of geometry and materials. To test the sensor in real conditions, a dedicated capacitive readout circuit based on high-frequency excitation and synchronous demodulation was developed to robustly acquire capacitance variations while rejecting static offsets and parasitic effects. Several formulations for the interposed dielectric layer material were investigated, including viscous fluids and composite mixtures with high-permittivity nanoparticles, with the aim of improving electrical sensitivity while preserving mechanical stability. Experimental results obtained under controlled loading and sliding conditions demonstrate that the sensor is highly sensitive to changes in contact state and tangential interaction dynamics. The sensor responded consistently to both load-induced shear and slip-related phenomena, enabling the reliable monitoring of contact dynamics rather than binary slip detection. A proof-of-concept integration into a robotic finger confirms the suitability of the proposed approach for grasp monitoring.
- 12 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (3) , 349
Open AccessModeling and Design of a Soft Capacitive Slip Sensor with Fluid Dielectric Interlayer
This paper presents the design, modeling, and experimental validation of a capacitive tactile sensor specifically conceived to sense shear-driven contact dynamics in robotic manipulation. The proposed device is a layered flexible capacitive structure, in which controlled tangential interactions are induced. The electrode design maximizes sensitivity to shear motion and promotes an isotropic response with respect to slip direction, thereby addressing two key limitations that affect the majority of existing slip-sensing technologies. An analytical model was developed to describe the essential relationship between shear-induced displacements and the electrical response, providing insight into the design parameters and supporting the selection of geometry and materials. To test the sensor in real conditions, a dedicated capacitive readout circuit based on high-frequency excitation and synchronous demodulation was developed to robustly acquire capacitance variations while rejecting static offsets and parasitic effects. Several formulations for the interposed dielectric layer material were investigated, including viscous fluids and composite mixtures with high-permittivity nanoparticles, with the aim of improving electrical sensitivity while preserving mechanical stability. Experimental results obtained under controlled loading and sliding conditions demonstrate that the sensor is highly sensitive to changes in contact state and tangential interaction dynamics. The sensor responded consistently to both load-induced shear and slip-related phenomena, enabling the reliable monitoring of contact dynamics rather than binary slip detection. A proof-of-concept integration into a robotic finger confirms the suitability of the proposed approach for grasp monitoring.
- Open Access
- 25 September 2025
- Published by MDPI AG in Electronics
- Vol. 14 (19) , 3798
Reliability and Performance Evaluation of IoT-Based Gas Leakage Detection Systems for Residential Environments
This paper presents the reliability assessment of an IoT-based sensor node designed for detecting combustible gas leaks in residential environments. Building on a previously published design that integrates low-power micromachined (Micro-Electro-Mechanical Systems, MEMS) pellistors and electrochemical Volatile Organic Compounds (VOC) sensors, this study evaluates the node’s long-term robustness and stability under both realistic and accelerated operating conditions. The system employs a dual-sensor strategy in which the VOC sensor acts as a sentinel, activating the pellistor only when necessary, thereby optimizing power consumption and extending battery life. BLE and LoRa communication capabilities support flexible deployment and real-time data transmission. To ensure suitability for safety-critical applications, we conducted comprehensive reliability testing, including accelerated life tests and environmental stress testing in compliance with IEC 60068 standards. The results confirm the system’s ability to maintain consistent performance and data integrity under thermal, mechanical, and chemical stress, demonstrating its robustness for prolonged operation in demanding environments. Overall, this work underscores the importance of rigorous reliability validation for IoT-based safety devices and positions the proposed solution as a significant step toward enhancing residential gas safety, with potential applications in broader industrial monitoring scenarios.
- 25 September 2025
- Published by MDPI AG in Electronics
- Vol. 14 (19) , 3798
Open AccessReliability and Performance Evaluation of IoT-Based Gas Leakage Detection Systems for Residential Environments
This paper presents the reliability assessment of an IoT-based sensor node designed for detecting combustible gas leaks in residential environments. Building on a previously published design that integrates low-power micromachined (Micro-Electro-Mechanical Systems, MEMS) pellistors and electrochemical Volatile Organic Compounds (VOC) sensors, this study evaluates the node’s long-term robustness and stability under both realistic and accelerated operating conditions. The system employs a dual-sensor strategy in which the VOC sensor acts as a sentinel, activating the pellistor only when necessary, thereby optimizing power consumption and extending battery life. BLE and LoRa communication capabilities support flexible deployment and real-time data transmission. To ensure suitability for safety-critical applications, we conducted comprehensive reliability testing, including accelerated life tests and environmental stress testing in compliance with IEC 60068 standards. The results confirm the system’s ability to maintain consistent performance and data integrity under thermal, mechanical, and chemical stress, demonstrating its robustness for prolonged operation in demanding environments. Overall, this work underscores the importance of rigorous reliability validation for IoT-based safety devices and positions the proposed solution as a significant step toward enhancing residential gas safety, with potential applications in broader industrial monitoring scenarios.
- Open Access
- 27 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 18180-18191
Sensorization of Soft Robot Joints for Accurate and Durable Bending Measurement
In the practical implementation of soft robots, accurately tracking the deformation of links (or joints) is crucial for obtaining proper control. Therefore, there is a need for lightweight, durable, and cost-effective solutions to monitor the movement of soft segments. This study proposes sensor-equipped flexible joints capable of measuring the angle between the segments of a robotic finger, considering pure in-in-plane bending. Initially, these joints were simulated to assess their mechanical behavior and the feasibility of accommodating strain gauges to measure differential strain, which correlates with angle measurements. Based on the simulation results, three types of sensor-equipped joints with distinct mechanical properties were developed. These joints were characterized in terms of angle measurement accuracy and durability. The experimental evaluation assessed that maximum error, compared to an accurate reference angle measured using a MEMS accelerometer, was less than 1.5°. Durability tests demonstrated that joint performance remained stable over more than 3500 bending cycles, during which the joints were bent up to approximately 65°; the measured angle drift remained below 2°.
- 27 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 18180-18191
Open AccessSensorization of Soft Robot Joints for Accurate and Durable Bending Measurement
In the practical implementation of soft robots, accurately tracking the deformation of links (or joints) is crucial for obtaining proper control. Therefore, there is a need for lightweight, durable, and cost-effective solutions to monitor the movement of soft segments. This study proposes sensor-equipped flexible joints capable of measuring the angle between the segments of a robotic finger, considering pure in-in-plane bending. Initially, these joints were simulated to assess their mechanical behavior and the feasibility of accommodating strain gauges to measure differential strain, which correlates with angle measurements. Based on the simulation results, three types of sensor-equipped joints with distinct mechanical properties were developed. These joints were characterized in terms of angle measurement accuracy and durability. The experimental evaluation assessed that maximum error, compared to an accurate reference angle measured using a MEMS accelerometer, was less than 1.5°. Durability tests demonstrated that joint performance remained stable over more than 3500 bending cycles, during which the joints were bent up to approximately 65°; the measured angle drift remained below 2°.
- 13 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Damped Sine Wave Parameter Extraction: Application to QCM-D Signals for Accurate Measurements
Quartz crystal microbalance with dissipation monitoring (QCM-D) is a sensing technique that finds diverse applications in chemical sensing, biosensing, and industrial fields. By monitoring the vibrational characteristics of a thin piezoelectric SiO2 resonator, this technique provides valuable information about the viscoelastic behavior of media in contact with its surface. This paper evaluates the performance of algorithms applied to 10 MHz AT-cut QCM-D signals for estimating the frequency and time constant related to the fundamental resonant mode, extending the study to assess the effectiveness of disturbance rejection, particularly against quartz spurious oscillating modes. To this end, both damped single-tone and three-tone signals are analyzed to cover all potential outputs of a QCM-D in its fundamental bulk shear mode. Various estimation algorithms are considered: one operating in the frequency domain and others in the time domain, based on model fitting techniques with novel preprocessing steps for optimized initialization. The analysis utilizes signals from a QCM-D measurement set-up and signals simulated according to the characteristics of the AT-CUT crystals used. Among model fitting-based estimators, two techniques were developed for single-tone and three-tone signals, splitting the model fitting problem into non-linear and linear subproblems, demonstrating the best accuracy and processing time. The developed techniques meet strict measurement objectives, achieving frequency measurement resolution around 1 ppm (10 Hz) and decay time accuracy around 1 μs, even with AWGN standard deviations of about 1% of the fundamental tone amplitude in water. These techniques are applicable in various contexts where recovering parameters from damped sine waves in the presence of white noise is required.
- 13 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Damped Sine Wave Parameter Extraction: Application to QCM-D Signals for Accurate Measurements
Quartz crystal microbalance with dissipation monitoring (QCM-D) is a sensing technique that finds diverse applications in chemical sensing, biosensing, and industrial fields. By monitoring the vibrational characteristics of a thin piezoelectric SiO2 resonator, this technique provides valuable information about the viscoelastic behavior of media in contact with its surface. This paper evaluates the performance of algorithms applied to 10 MHz AT-cut QCM-D signals for estimating the frequency and time constant related to the fundamental resonant mode, extending the study to assess the effectiveness of disturbance rejection, particularly against quartz spurious oscillating modes. To this end, both damped single-tone and three-tone signals are analyzed to cover all potential outputs of a QCM-D in its fundamental bulk shear mode. Various estimation algorithms are considered: one operating in the frequency domain and others in the time domain, based on model fitting techniques with novel preprocessing steps for optimized initialization. The analysis utilizes signals from a QCM-D measurement set-up and signals simulated according to the characteristics of the AT-CUT crystals used. Among model fitting-based estimators, two techniques were developed for single-tone and three-tone signals, splitting the model fitting problem into non-linear and linear subproblems, demonstrating the best accuracy and processing time. The developed techniques meet strict measurement objectives, achieving frequency measurement resolution around 1 ppm (10 Hz) and decay time accuracy around 1 μs, even with AWGN standard deviations of about 1% of the fundamental tone amplitude in water. These techniques are applicable in various contexts where recovering parameters from damped sine waves in the presence of white noise is required.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (19) , 31442-31455
Low-Complexity Neural Network-Based Processing Algorithm for QCM-D Signals
This paper introduces a novel approach to estimate the oscillation frequency and decay time constant of Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) signals using low-complexity neural network models. The proposed method involves a two-step process: frequency domain preprocessing using Fast Fourier Transform (FFT) followed by a shallow neural network for frequency estimation, and time domain preprocessing for envelope detection followed by a second shallow neural network for time constant estimation. The networks were trained and tested on datasets from both a dedicated QCM-D testbench and a numerical simulator. The results demonstrate accurate estimation with errors below 10 Hz for the frequency and 1 μs for the time constant, making the approach promising for various QCM-D applications. The simplicity of the neural network models facilitates the implementation on embedded platforms, reducing the system complexity and offering potential for cost-effective QCM-D sensing systems.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (19) , 31442-31455
Low-Complexity Neural Network-Based Processing Algorithm for QCM-D Signals
This paper introduces a novel approach to estimate the oscillation frequency and decay time constant of Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) signals using low-complexity neural network models. The proposed method involves a two-step process: frequency domain preprocessing using Fast Fourier Transform (FFT) followed by a shallow neural network for frequency estimation, and time domain preprocessing for envelope detection followed by a second shallow neural network for time constant estimation. The networks were trained and tested on datasets from both a dedicated QCM-D testbench and a numerical simulator. The results demonstrate accurate estimation with errors below 10 Hz for the frequency and 1 μs for the time constant, making the approach promising for various QCM-D applications. The simplicity of the neural network models facilitates the implementation on embedded platforms, reducing the system complexity and offering potential for cost-effective QCM-D sensing systems.
- Open Access
Advancing Thrombosis Research: A Novel Device for Measuring Clot Permeability
Thromboembolism, a global leading cause of mortality, needs accurate risk assessment for effective prophylaxis and treatment. Current stratification methods fall short in predicting thrombotic events, emphasizing the need for a deeper understanding of clot properties. Fibrin clot permeability, a crucial parameter in hypercoagulable states, impacts clot structure and resistance to lysis. Current clot permeability measurement limitations propel the need for standardized methods. Prior findings underscore the importance of clot permeability in various thrombotic conditions but call for improvements and more precise, repeatable, and standardized methods. Addressing these challenges, our study presents an upgraded, portable, and cost-effective system for measuring blood clot permeability, which utilizes a pressure-based approach that adheres to Darcy’s law. By enhancing precision and sensitivity in discerning clot characteristics, this innovation provides a valuable tool for assessing thrombotic risk and associated pathological conditions. In this paper, the authors present a device that is able to automatically perform the permeability measurements on plasma or fibrinogen in vitro-induced clots on specific holders (filters). The proposed device has been tailored to distinguish clot permeability, with high precision and sensitivity, between healthy subjects and high cardiovascular-risk patients. The precise measure of clot permeability represents an excellent indicator of thrombotic risk, thus allowing the clinician, also on the basis of other anamnestic and laboratory data, to attribute a risk score to the subject. The proposed instrument was characterized by performing permeability measurements in plasma and purified fibrinogen clots derived from 17 Behcet patients and 15 sex- and age-matched controls. As expected, our results clearly indicate a significant difference in plasma clot permeability in Behcet patients with respect to controls (0.0533 ± 0.0199 d vs. 0.0976 ± 0.0160 d, p < 0.001). This difference was confirmed in the patient’s vs. control fibrin clots (0.0487 ± 0.0170 d vs. 0.1167 ± 0.0487 d, p < 0.001). In conclusion, our study demonstrates the feasibility, efficacy, portability, and cost-effectiveness of a novel device for measuring clot permeability, allowing healthcare providers to better stratify thrombotic risk and tailor interventions, thereby improving patient outcomes and reducing healthcare costs, which could significantly improve the management of thromboembolic diseases.
Open AccessAdvancing Thrombosis Research: A Novel Device for Measuring Clot Permeability
Thromboembolism, a global leading cause of mortality, needs accurate risk assessment for effective prophylaxis and treatment. Current stratification methods fall short in predicting thrombotic events, emphasizing the need for a deeper understanding of clot properties. Fibrin clot permeability, a crucial parameter in hypercoagulable states, impacts clot structure and resistance to lysis. Current clot permeability measurement limitations propel the need for standardized methods. Prior findings underscore the importance of clot permeability in various thrombotic conditions but call for improvements and more precise, repeatable, and standardized methods. Addressing these challenges, our study presents an upgraded, portable, and cost-effective system for measuring blood clot permeability, which utilizes a pressure-based approach that adheres to Darcy’s law. By enhancing precision and sensitivity in discerning clot characteristics, this innovation provides a valuable tool for assessing thrombotic risk and associated pathological conditions. In this paper, the authors present a device that is able to automatically perform the permeability measurements on plasma or fibrinogen in vitro-induced clots on specific holders (filters). The proposed device has been tailored to distinguish clot permeability, with high precision and sensitivity, between healthy subjects and high cardiovascular-risk patients. The precise measure of clot permeability represents an excellent indicator of thrombotic risk, thus allowing the clinician, also on the basis of other anamnestic and laboratory data, to attribute a risk score to the subject. The proposed instrument was characterized by performing permeability measurements in plasma and purified fibrinogen clots derived from 17 Behcet patients and 15 sex- and age-matched controls. As expected, our results clearly indicate a significant difference in plasma clot permeability in Behcet patients with respect to controls (0.0533 ± 0.0199 d vs. 0.0976 ± 0.0160 d, p < 0.001). This difference was confirmed in the patient’s vs. control fibrin clots (0.0487 ± 0.0170 d vs. 0.1167 ± 0.0487 d, p < 0.001). In conclusion, our study demonstrates the feasibility, efficacy, portability, and cost-effectiveness of a novel device for measuring clot permeability, allowing healthcare providers to better stratify thrombotic risk and tailor interventions, thereby improving patient outcomes and reducing healthcare costs, which could significantly improve the management of thromboembolic diseases.
- Open Access
Influence of Front-End Electronics on Metrological Performance of QCM Systems
Quartz Crystal Microbalances (QCMs) are versatile sensors employed in various fields, from environmental monitoring to biomedical applications, owing mainly to their very high sensitivity. However, the assessment of their metrological performance, including the impact of conditioning circuits, digital processing algorithms, and working conditions, is a complex and novel area of study. The purpose of this work is to investigate and understand the measurement errors associated with different QCM measurement techniques, specifically focusing on the influence of conditioning electronic circuits. Through a tailored and novel experimental setup, two measurement architectures—a Quartz Crystal Microbalance with dissipation monitoring (QCM-D) system and an oscillator-based QCM-R system—were compared under the same mechanical load conditions. Through rigorous experimentation and signal processing techniques, the study elucidated the complexities of accurately assessing QCM parameters, especially in liquid environments and under large mechanical loads. The comparison between the two different techniques allows for highlighting the critical aspects of the measurement techniques. The experimental results were discussed and interpreted based on models allowing for a deep understanding of the measurement problems encountered with QCM-based measurement systems. The performance of the different techniques was derived, showing that while the QCM-D technique exhibited higher accuracy, the QCM-R technique offered greater precision with a simpler design. This research advances our understanding of QCM-based measurements, providing insights for designing robust measurement systems adaptable to diverse conditions, thus enhancing their effectiveness in various applications.
Open AccessInfluence of Front-End Electronics on Metrological Performance of QCM Systems
Quartz Crystal Microbalances (QCMs) are versatile sensors employed in various fields, from environmental monitoring to biomedical applications, owing mainly to their very high sensitivity. However, the assessment of their metrological performance, including the impact of conditioning circuits, digital processing algorithms, and working conditions, is a complex and novel area of study. The purpose of this work is to investigate and understand the measurement errors associated with different QCM measurement techniques, specifically focusing on the influence of conditioning electronic circuits. Through a tailored and novel experimental setup, two measurement architectures—a Quartz Crystal Microbalance with dissipation monitoring (QCM-D) system and an oscillator-based QCM-R system—were compared under the same mechanical load conditions. Through rigorous experimentation and signal processing techniques, the study elucidated the complexities of accurately assessing QCM parameters, especially in liquid environments and under large mechanical loads. The comparison between the two different techniques allows for highlighting the critical aspects of the measurement techniques. The experimental results were discussed and interpreted based on models allowing for a deep understanding of the measurement problems encountered with QCM-based measurement systems. The performance of the different techniques was derived, showing that while the QCM-D technique exhibited higher accuracy, the QCM-R technique offered greater precision with a simpler design. This research advances our understanding of QCM-based measurements, providing insights for designing robust measurement systems adaptable to diverse conditions, thus enhancing their effectiveness in various applications.
- Open Access
A Low Complexity Rolling Bearing Diagnosis Technique Based on Machine Learning and Smart Preprocessing
In this work, we present a diagnosis system for rolling bearings that leverages simultaneous measurements of vibrations and machine rotation speed. Our approach combines the robustness of simple time domain methods for fault detection with the potential of machine learning techniques for fault location. This research is based on a neural network classifier, which exploits a simple and novel preprocessing algorithm specifically designed for minimizing the dependency of the classifier performance on the machine working conditions, on the bearing model and on the acquisition system set-up. The overall diagnosis system is based on light algorithms with reduced complexity and hardware resource demand and is designed to be deployed in embedded electronics. The fault diagnosis system was trained using emulated data, exploiting an ad-hoc test bench thus avoiding the problem of generating enough data, achieving an overall classifier accuracy larger than 98%. Its noteworthy ability to generalize was proven by using data emulating different working conditions and acquisition set-ups and noise levels, obtaining in all the cases accuracies greater than 97%, thereby proving in this way that the proposed system can be applied in a wide spectrum of different applications. Finally, real data from an on-line database containing vibration signals obtained in a completely different scenario are used to demonstrate the distinctive capability of the proposed system to generalize.
Open AccessA Low Complexity Rolling Bearing Diagnosis Technique Based on Machine Learning and Smart Preprocessing
In this work, we present a diagnosis system for rolling bearings that leverages simultaneous measurements of vibrations and machine rotation speed. Our approach combines the robustness of simple time domain methods for fault detection with the potential of machine learning techniques for fault location. This research is based on a neural network classifier, which exploits a simple and novel preprocessing algorithm specifically designed for minimizing the dependency of the classifier performance on the machine working conditions, on the bearing model and on the acquisition system set-up. The overall diagnosis system is based on light algorithms with reduced complexity and hardware resource demand and is designed to be deployed in embedded electronics. The fault diagnosis system was trained using emulated data, exploiting an ad-hoc test bench thus avoiding the problem of generating enough data, achieving an overall classifier accuracy larger than 98%. Its noteworthy ability to generalize was proven by using data emulating different working conditions and acquisition set-ups and noise levels, obtaining in all the cases accuracies greater than 97%, thereby proving in this way that the proposed system can be applied in a wide spectrum of different applications. Finally, real data from an on-line database containing vibration signals obtained in a completely different scenario are used to demonstrate the distinctive capability of the proposed system to generalize.
- Open Access
A Distributed IoT Air Quality Measurement System for High-Risk Workplace Safety Enhancement
The safety of an operator working in a hazardous environment is a recurring topic in the technical literature of recent years, especially for high-risk environments such as oil and gas plants, refineries, gas depots, or chemical industries. One of the highest risk factors is constituted by the presence of gaseous substances such as toxic compounds such as carbon monoxide and nitric oxides, particulate matter or indoors, in closed spaces, low oxygen concentration atmospheres, and high concentrations of CO2 that can represent a risk for human health. In this context, there exist many monitoring systems for lots of specific applications where gas detection is required. In this paper, the authors present a distributed sensing system based on commercial sensors aimed at monitoring the presence of toxic compounds generated by a melting furnace with the aim of reliably detecting the insurgence of dangerous conditions for workers. The system is composed of two different sensor nodes and a gas analyzer, and it exploits commercial low-cost commercially available sensors.
Open AccessA Distributed IoT Air Quality Measurement System for High-Risk Workplace Safety Enhancement
The safety of an operator working in a hazardous environment is a recurring topic in the technical literature of recent years, especially for high-risk environments such as oil and gas plants, refineries, gas depots, or chemical industries. One of the highest risk factors is constituted by the presence of gaseous substances such as toxic compounds such as carbon monoxide and nitric oxides, particulate matter or indoors, in closed spaces, low oxygen concentration atmospheres, and high concentrations of CO2 that can represent a risk for human health. In this context, there exist many monitoring systems for lots of specific applications where gas detection is required. In this paper, the authors present a distributed sensing system based on commercial sensors aimed at monitoring the presence of toxic compounds generated by a melting furnace with the aim of reliably detecting the insurgence of dangerous conditions for workers. The system is composed of two different sensor nodes and a gas analyzer, and it exploits commercial low-cost commercially available sensors.