Yoshihide Katayama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yoshihide Katayama has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ichiro Baba
Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University
1 shared publication Masahiko Wanibuchi
Osaka Medical and Pharmaceutical University
1 shared publication- Masahiko Wanibuchi
Department of Neurosurgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
1 shared publication - Masahiro Kameda
Department of Neurosurgery, Osaka Medical and Pharmaceutical University
1 shared publication Motomasa Furuse
Osaka Medical and Pharmaceutical University
1 shared publication- Motomasa Furuse
Department of Neurosurgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan
1 shared publication
Latest Publications
- Open Access
- 27 August 2022
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 62 (9) , 2022-0158-443
Multimodal Management of Combined Posterior and Anterior Surgical Approach and Postoperative Pharmacological Therapy for Giant Cell Tumor of the Cervical Spine Encasing the Vertebral Artery: A Technical Case Report
Giant cell tumor (GCT) of bone is essentially benign but locally aggressive, and the rate of local recurrence is high when the resection is not enough. En bloc resection is recommended as an ideal solution for GCT to decrease the risk of local recurrence, but it remains challenging for cervical GCT. In this technical case report, we present a case of extensively infiltrating GCT of the cervical spine completely encasing the vertebral artery (VA) on one side. The tumor was distributed to layers A-D, sectors 3-8 based on the Weinstein-Boriani-Biagini staging. Combined posterior and anterior surgical approach for the cervical spine was successfully performed and followed by postoperative adjuvant pharmacological therapy. This kind of multimodal management may be one of the solutions for advanced cervical GCT.
- 27 August 2022
- Published by Japan Neurosurgical Society in Neurologia medico-chirurgica
- Vol. 62 (9) , 2022-0158-443
Open AccessMultimodal Management of Combined Posterior and Anterior Surgical Approach and Postoperative Pharmacological Therapy for Giant Cell Tumor of the Cervical Spine Encasing the Vertebral Artery: A Technical Case Report
Giant cell tumor (GCT) of bone is essentially benign but locally aggressive, and the rate of local recurrence is high when the resection is not enough. En bloc resection is recommended as an ideal solution for GCT to decrease the risk of local recurrence, but it remains challenging for cervical GCT. In this technical case report, we present a case of extensively infiltrating GCT of the cervical spine completely encasing the vertebral artery (VA) on one side. The tumor was distributed to layers A-D, sectors 3-8 based on the Weinstein-Boriani-Biagini staging. Combined posterior and anterior surgical approach for the cervical spine was successfully performed and followed by postoperative adjuvant pharmacological therapy. This kind of multimodal management may be one of the solutions for advanced cervical GCT.
- Open Access
- 18 October 2021
- Published by Springer Nature in Research Square
Development of novel Mixed Reality-Based Simulator for Endoscopic Transnasal Surgery with HoloLens and multiple AR tracker
Background Virtual reality (VR) and mixed reality (MR) are now widely applied for preoperative simulation and intraoperative navigation. Methods We developed an MR-based simulator for endoscopic transnasal surgery (ETNS) with a head-mounted display HoloLens and evaluated its usefulness. This simulator consisted of MR images of patients and an MR endoscope. HoloLens was used for projection of MR images and recognition of markers. The MR images were reconstructed from the preoperative images of patients and superimposed onto the endoscopic training model of the head. The MR endoscope was superimposed onto a three-dimensional (3D) printed replica of an endoscope. The MR endoscopic images from the replica of the endoscope were projected in the operator’s visual field. The MR images followed the manipulation of the replica of the endoscope through a nasal cavity on the training model. To evaluate the developed simulator, the MR endoscopic images were compared with video-recorded actual operative endoscopic views. And face validity and content validity of the simulator were evaluated by senior residents, using a 5-point Likert scale. Result The 3D MR images through HoloLens correlated well with the actual intraoperative views. Although there was an innate learning curve with the simulator, the face validity and the content validity demonstrated effective simulation of an operative field of view with real-time characteristics of the surgical procedure. Conclusions Our developed simulator for ETNS will contribute to learning the unique and the limited surgical fields through the narrow surgical corridor with endoscope, particularly for novice surgeons.
- 18 October 2021
- Published by Springer Nature in Research Square
Open AccessDevelopment of novel Mixed Reality-Based Simulator for Endoscopic Transnasal Surgery with HoloLens and multiple AR tracker
Background Virtual reality (VR) and mixed reality (MR) are now widely applied for preoperative simulation and intraoperative navigation. Methods We developed an MR-based simulator for endoscopic transnasal surgery (ETNS) with a head-mounted display HoloLens and evaluated its usefulness. This simulator consisted of MR images of patients and an MR endoscope. HoloLens was used for projection of MR images and recognition of markers. The MR images were reconstructed from the preoperative images of patients and superimposed onto the endoscopic training model of the head. The MR endoscope was superimposed onto a three-dimensional (3D) printed replica of an endoscope. The MR endoscopic images from the replica of the endoscope were projected in the operator’s visual field. The MR images followed the manipulation of the replica of the endoscope through a nasal cavity on the training model. To evaluate the developed simulator, the MR endoscopic images were compared with video-recorded actual operative endoscopic views. And face validity and content validity of the simulator were evaluated by senior residents, using a 5-point Likert scale. Result The 3D MR images through HoloLens correlated well with the actual intraoperative views. Although there was an innate learning curve with the simulator, the face validity and the content validity demonstrated effective simulation of an operative field of view with real-time characteristics of the surgical procedure. Conclusions Our developed simulator for ETNS will contribute to learning the unique and the limited surgical fields through the narrow surgical corridor with endoscope, particularly for novice surgeons.