Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kwanhee Lee has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Early-stage diagnosis of bladder cancer using surface-enhanced Raman spectroscopy combined with machine learning algorithms in a rat model

    by Sanghwa Lee, Miyeon Jue, Kwanhee Lee, Bjorn Paulson, Jeongmin Oh, Minju Cho, Jun Ki Kim


  • A Study on the Didactic Transposition of “Transformative Competencies” and “Student Agency” in Elementary Korean Education

    by Kwanhee Lee

    본고에서는 Education 2030 프로젝트의 ‘변혁적 역량’과 ‘학습자 행위 주체성’을 관점이자 지향으로 삼아 특정 교육 요소가 교과서에서 교육 내용화된 양상을 확인하였다. 이때, 두 개념의 주요 요소와 국어교육의 관련 항목을 대당하는 방식보다는, 두 개념의 소통 맥락 및 지향을 국어교육의 입장에서 해석함으로써 교과적 변별성을 확보하고자 하였다. 이러한 관점을 바탕으로 변혁적 역량과 관련해서는 초등 국어 교과서에서 기사문을 다루는 양상을 분석하였다. ‘변혁적’의 의미는 변화 그 자체에만 주목하기보다는 변화 속에서도 불변하는 언어적 요인에 있다고 보아, 기사문 제재를 어떠한 교육 내용과 중핵적으로 연계해야 하는지를 살폈다. 이 과정에서 현재의 교과서에서는 기사문이 국어 교과의 변별성이 두드러지는 방향으로 다루어지지 않았음을 점검하였고, 특히 ‘사실과 의견 구별하기’와의 통합 속에서 기사문을 적극적으로 탐색해야 함을 논의하였다. 행위 주체성의 경우 학습자의 교육적 선택과 책임의 문제로만 접근해서는 국어 교과적 변별성이 부각되지 않는다는 판단 아래, 맥락 구성의 주체로서의 학습자를 조명할 필요가 있음을 논구하였다. 이를 바탕으로 초등 국어 교과서를 점검하여 맥락 속에서의 사용 자원으로 속담이 교육 내용화 되었다고 보기에 제한적인 지점들을 논의의 대상으로 삼았다.

  • Open Access

    Smartphone-Based Rigid Endoscopy Device with Hemodynamic Response Imaging and Laser Speckle Contrast Imaging

    by Youngkyu Kim, Woo June Choi, Jeongmin Oh, Kwanhee Lee, Jun Ki Kim

    Modern smartphones have been employed as key elements in point-of-care (POC) devices due to remarkable advances in their form factor, computing, and display performances. Recently, we reported a combination of the smartphone with a handheld endoscope using laser speckle contrast imaging (LSCI), suggesting potential for functional POC endoscopy. Here, we extended our work to develop a smartphone-combined multifunctional handheld endoscope using dual-wavelength LSCI. Dual-wavelength LSCI is used to monitor the changes in dynamic blood flow as well as changes in the concentration of oxygenated (HbO2), deoxygenated (Hbr), and total hemoglobin (HbT). The smartphone in the device performs fast acquisition and computation of the raw LSCI data to map the blood perfusion parameters. The flow imaging performance of the proposed device was tested with a tissue-like flow phantom, exhibiting a speckle flow index map representing the blood perfusion. Furthermore, the device was employed to assess the blood perfusion status from an exteriorized intestine model of rat in vivo during and after local ischemia, showing that blood flow and HbO2 gradually decreased in the ischemic region whereas hyperemia and excess increases in HbO2 were observed in the same region right after reperfusion. The results indicate that the combination of LSCI with smartphone endoscopy delivers a valuable platform for better understanding of the functional hemodynamic changes in the vasculatures of the internal organs, which may benefit POC testing for diagnosis and treatment of vascular diseases.


  • Open Access

    Spectral Multiplexing of Fluorescent Endoscopy for Simultaneous Imaging with Multiple Fluorophores and Multiple Fields of View

    by Bjorn Paulson, Saeed Bohlooli Darian, Youngkyu Kim, Jeongmin Oh, Marjan Ghasemi, Kwanhee Lee, Jun Ki Kim

    Complex clinical procedures and small-animal research procedures can benefit from dual-site imaging provided by multiple endoscopic devices. Here, an endoscopic system is proposed which enables multiple fluorescence microendoscopes to be spectrally multiplexed on a single microscope base, enabling light sources and optical relays to be shared between endoscopes. The presented system is characterized for resolution using USAF-1951 resolution test charts and for modulation transfer function using the slanted edge method. Imaging is demonstrated both directly and with microendoscopes attached. Imaging of phantoms was demonstrated by targeting USAF charts and fiber tissues dyed for FITC and Texas Red fluorescence. Afterwards, simultaneous liver and kidney imaging was demonstrated in mice expressing mitochondrial Dendra2 and injected with Texas Red-dextran. The results indicate that the system achieves high channel isolation and submicron and subcellular resolution, with resolution limited by the endoscopic probe and by physiological movement during endoscopic imaging. Multi-channel microendoscopy provides a potentially low-cost means of simultaneous multiple endoscopic imaging during biological experiments, resulting in reduced animal harm and potentially increasing insight into temporal connections between connected biological systems.


  • Open Access

    A Wi-Fi–Based Mask-Type Laryngoscope for Telediagnosis During the COVID-19 Pandemic: Instrument Validation Study

    by Youngjin Moon, Jaeho Hyun, Jeongmin Oh, Kwanhee Lee, Yoon Se Lee, Jun Ki Kim

    Background: Owing to the COVID-19 pandemic, social distancing has become mandatory. Wireless endoscopy in contactless examinations promises to protect health care workers and reduce viral spread. Objective: This study aimed to introduce a contactless endoscopic diagnosis system using a wireless endoscope resembling a mask. Methods: The Wi-Fi–based contactless mask endoscopy system comprises a disposable endoscope and a controller. First, the effective force applied by the tip during insertion was evaluated in a simple transoral model consisting of a force sensor on a simulated oropharynx wall. Second, the delay in video streaming was evaluated by comparing the frame rate and delays between a movement and its image over direct and Wi-Fi connections. Third, the system was applied to a detailed laryngopharyngeal tract phantom. Results: The smartphone-controlled wireless endoscopy system was successfully evaluated. The mean, maximum, and minimum collision forces against the wall of the transoral model were 296 mN (30 gf), 363 mN (37 gf), and 235 mN (24 gf), respectively. The delay resulting from the wireless connection was 0.72 seconds. Using the phantom, an inexperienced user took around 1 minute to orient the endoscope to a desired area via the app. Conclusions: Device articulation does not pose a significant risk of laryngopharyngeal wall penetration, and latency does not significantly impede its use. Contactless wireless video streaming was successful within the access point range regardless of the presence of walls. The mask endoscope can be controlled and articulated wirelessly, minimizing contact between patients and device operators. By minimizing contact, the device can protect health care workers from infectious viruses like the coronavirus.


  • Open Access

    A Wi-Fi–Based Mask-Type Laryngoscope for Telediagnosis During the COVID-19 Pandemic: Instrument Validation Study (Preprint)

    by Youngjin Moon, Jaeho Hyun, Jeongmin Oh, Kwanhee Lee, Yoon Se Lee, Jun Ki Kim

    BACKGROUND Owing to the COVID-19 pandemic, social distancing has become mandatory. Wireless endoscopy in contactless examinations promises to protect health care workers and reduce viral spread. OBJECTIVE This study aimed to introduce a contactless endoscopic diagnosis system using a wireless endoscope resembling a mask. METHODS The Wi-Fi–based contactless mask endoscopy system comprises a disposable endoscope and a controller. First, the effective force applied by the tip during insertion was evaluated in a simple transoral model consisting of a force sensor on a simulated oropharynx wall. Second, the delay in video streaming was evaluated by comparing the frame rate and delays between a movement and its image over direct and Wi-Fi connections. Third, the system was applied to a detailed laryngopharyngeal tract phantom. RESULTS The smartphone-controlled wireless endoscopy system was successfully evaluated. The mean, maximum, and minimum collision forces against the wall of the transoral model were 296 mN (30 gf), 363 mN (37 gf), and 235 mN (24 gf), respectively. The delay resulting from the wireless connection was 0.72 seconds. Using the phantom, an inexperienced user took around 1 minute to orient the endoscope to a desired area via the app. CONCLUSIONS Device articulation does not pose a significant risk of laryngopharyngeal wall penetration, and latency does not significantly impede its use. Contactless wireless video streaming was successful within the access point range regardless of the presence of walls. The mask endoscope can be controlled and articulated wirelessly, minimizing contact between patients and device operators. By minimizing contact, the device can protect health care workers from infectious viruses like the coronavirus. CLINICALTRIAL

  • Open Access

    SERS Effect on Spin-Coated Seeding of Tilted Au-ZnO Nanorods for Low-Cost Diagnosis

    by Miyeon Jue, Chan-Gi Pack, Seakhee Oh, Bjorn Paulson, Kwanhee Lee, Jun Ki Kim

    Uniformly parallel Au-coated ZnO nanorods have previously been shown to amplify local Raman signals, providing increased sensitivity to disease markers in the detection of inflammation and cancer. However, practical and cost-effective fabrication methods of substrates for surface-enhanced Raman spectroscopy (SERS) fail to produce highly uniform surfaces. Here, the feasibility of Raman enhancement on less-uniform substrates is assessed. ZnO nanorod structures were fabricated by hydrothermal synthesis, starting from spin-coated seed substrates. Following analysis, the nanostructures were coated with Au to create stochastically variant substrates. The non-uniformity of the fabricated Au-coated ZnO nanorod structures is confirmed morphologically by FE-SEM and structurally by X-ray diffraction, and characterized by the angular distributions of the nanorods. Monte Carlo finite element method simulations matching the measured angular distributions and separations predicted only moderate increases in the overall Raman enhancement with increasing uniformity. Highly variant substrates exhibited approximately 76% of the Raman enhancement of more uniform substrates in simulations and experiments. The findings suggest that, although highly inhomogeneous Au-coated ZnO nanorod substrates may not attain the same Raman enhancement as more uniform substrates, the relaxation of fabrication tolerances may be economically viable.