Brian K. Foster
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brian K. Foster has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Louis Christopher Grandizio
Department of Orthopaedic Surgery, Geisinger Musculoskeletal Institute, Geisinger Commonwealth School of Medicine, Danville, PA
5 shared publications Daniel S. Hayes
Geisinger Commonwealth School of Medicine, Danville, PA, USA
2 shared publicationsYagiz Ozdag
Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, Danville, PA
2 shared publications- A. Michael Luciani
Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
1 shared publication - Alexander W. Mettler
Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, 21-30, 100 N Academy Ave, Danville, PA 17822, USA
1 shared publication Benchaa Boualam
Geisinger Commonwealth School of Medicine, Danville, PA, USA
1 shared publication
Latest Publications
- Open Access
- 16 July 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (2) , e439-e449
Preventing posterior interosseous nerve injury during a distal biceps tendon repair: an anatomic study comparing extensor digitorum communis and extensor carpi ulnaris muscle splitting approaches
- 16 July 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (2) , e439-e449
Open AccessPreventing posterior interosseous nerve injury during a distal biceps tendon repair: an anatomic study comparing extensor digitorum communis and extensor carpi ulnaris muscle splitting approaches
- 14 September 2024
- Published by Elsevier in Journal of Surgical Education
- Vol. 81 (11) , 1645-1649
Artificial Intelligence in Orthopaedics: Performance of ChatGPT on Text and Image Questions on a Complete AAOS Orthopaedic In-Training Examination (OITE)
- 14 September 2024
- Published by Elsevier in Journal of Surgical Education
- Vol. 81 (11) , 1645-1649
Artificial Intelligence in Orthopaedics: Performance of ChatGPT on Text and Image Questions on a Complete AAOS Orthopaedic In-Training Examination (OITE)
- 9 February 2023
- Published by SAGE Publications in HAND
- Vol. 19 (7) , 1125-1131
Publicly Disclosed Pricing for Common Upper-Extremity Procedures: An Analysis of Hospital Chargemasters
Background: American hospitals are required to provide price transparency data (known as a chargemaster) for medical services, which is intended to allow consumers to accurately estimate the cost of medical services. Our purpose was to identify hospital compliance in publishing chargemaster documents and to assess the price information published for common upper-extremity services and procedures. Methods: We performed a cross-sectional analysis of publicly available chargemaster data from 122 hospitals, which included the top-20-ranked Honor Roll hospitals from US News and World Report and 2 top-ranked hospitals from each state. Chargemaster files were accessed for each hospital, and price information was recorded for 10 common upper-extremity procedures including radiographs, injections, and surgeries. Mean procedural prices were compared between academic and nonacademic hospitals. Results: Chargemaster files were able to be accessed for 107 (88%) of 122 institutions. Price estimates for imaging studies were more frequently reported (73%) than those of procedures (23%-41%). With 50 hospitals reporting a price estimate, carpal tunnel injection was the most frequently reported procedure, whereas trigger finger release was the least frequently reported (41% and 23%, respectively). Wide price ranges were noted, with mean charges for a total shoulder arthroplasty listed as US $51 723 (range, US $247-US $364 024). Mean prices between academic and nonacademic hospital systems were similar. Conclusions: While most (88%) of the included hospitals have been compliant with publishing their price transparency files, price estimates for common upper-extremity procedures and imaging studies are inconsistently reported and, when present, demonstrate high levels of price variability between and within hospital systems.
- 9 February 2023
- Published by SAGE Publications in HAND
- Vol. 19 (7) , 1125-1131
Publicly Disclosed Pricing for Common Upper-Extremity Procedures: An Analysis of Hospital Chargemasters
Background: American hospitals are required to provide price transparency data (known as a chargemaster) for medical services, which is intended to allow consumers to accurately estimate the cost of medical services. Our purpose was to identify hospital compliance in publishing chargemaster documents and to assess the price information published for common upper-extremity services and procedures. Methods: We performed a cross-sectional analysis of publicly available chargemaster data from 122 hospitals, which included the top-20-ranked Honor Roll hospitals from US News and World Report and 2 top-ranked hospitals from each state. Chargemaster files were accessed for each hospital, and price information was recorded for 10 common upper-extremity procedures including radiographs, injections, and surgeries. Mean procedural prices were compared between academic and nonacademic hospitals. Results: Chargemaster files were able to be accessed for 107 (88%) of 122 institutions. Price estimates for imaging studies were more frequently reported (73%) than those of procedures (23%-41%). With 50 hospitals reporting a price estimate, carpal tunnel injection was the most frequently reported procedure, whereas trigger finger release was the least frequently reported (41% and 23%, respectively). Wide price ranges were noted, with mean charges for a total shoulder arthroplasty listed as US $51 723 (range, US $247-US $364 024). Mean prices between academic and nonacademic hospital systems were similar. Conclusions: While most (88%) of the included hospitals have been compliant with publishing their price transparency files, price estimates for common upper-extremity procedures and imaging studies are inconsistently reported and, when present, demonstrate high levels of price variability between and within hospital systems.
- 21 September 2022
- Published by SAGE Publications in HAND
- Vol. 19 (3) , 456-463
Reporting Bias in Systematic Reviews and Meta-Analyses Related to the Treatment of Distal Radius Fractures: The Presence of Spin in the Abstract
Background: Spin is a form of reporting bias which suggests a treatment is beneficial despite a statistically nonsignificant difference in outcomes. Our purpose was to define the prevalence of spin within the abstracts of distal radius fracture (DRF) systematic reviews (SRs) and meta-analyses (MA). We also sought to identify article characteristics that were more likely to contain spin. Methods: We performed a SR of multiple databases to identify DRF SRs and MAs. Articles were screened and analyzed by 3 reviewers. We recorded article and journal characteristics including adherence to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, funding disclosures, methodologic quality (AMSTAR 2 instrument), impact factor, and country of origin. Presence of the 9 most severe types of spin in abstracts were recorded. Unadjusted odds ratios (ORs) were calculated to analyze the association between article characteristics and the presence of spin. Results: A total of 112 articles were included. Spin was present in 46% of abstracts, with type 1 spin (“conclusions not supported by findings”) most frequent (19%). Spin was present in 43% of abstracts in PRISMA-adhering journals compared to 49% in journals that did not (OR = 0.79, 95% confidence interval [CI] = 0.37-1.68). For articles originating from China, spin was present in 61% of abstracts compared to 39% of abstracts from other countries (OR = 2.55, 95% CI = 1.13-5.75). Conclusions: In addition to low article quality, there are high rates of spin within the abstracts of SRs and MAs related to treatment of DRF. Articles within journals that adhere to PRISMA do not appear to contain less spin.
- 21 September 2022
- Published by SAGE Publications in HAND
- Vol. 19 (3) , 456-463
Reporting Bias in Systematic Reviews and Meta-Analyses Related to the Treatment of Distal Radius Fractures: The Presence of Spin in the Abstract
Background: Spin is a form of reporting bias which suggests a treatment is beneficial despite a statistically nonsignificant difference in outcomes. Our purpose was to define the prevalence of spin within the abstracts of distal radius fracture (DRF) systematic reviews (SRs) and meta-analyses (MA). We also sought to identify article characteristics that were more likely to contain spin. Methods: We performed a SR of multiple databases to identify DRF SRs and MAs. Articles were screened and analyzed by 3 reviewers. We recorded article and journal characteristics including adherence to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, funding disclosures, methodologic quality (AMSTAR 2 instrument), impact factor, and country of origin. Presence of the 9 most severe types of spin in abstracts were recorded. Unadjusted odds ratios (ORs) were calculated to analyze the association between article characteristics and the presence of spin. Results: A total of 112 articles were included. Spin was present in 46% of abstracts, with type 1 spin (“conclusions not supported by findings”) most frequent (19%). Spin was present in 43% of abstracts in PRISMA-adhering journals compared to 49% in journals that did not (OR = 0.79, 95% confidence interval [CI] = 0.37-1.68). For articles originating from China, spin was present in 61% of abstracts compared to 39% of abstracts from other countries (OR = 2.55, 95% CI = 1.13-5.75). Conclusions: In addition to low article quality, there are high rates of spin within the abstracts of SRs and MAs related to treatment of DRF. Articles within journals that adhere to PRISMA do not appear to contain less spin.
- 1 June 2022
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 32 (2) , 211-217
Shoulder and elbow arthroplasty videos on YouTube: an analysis of video content and quality
- 1 June 2022
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 32 (2) , 211-217
Shoulder and elbow arthroplasty videos on YouTube: an analysis of video content and quality
- 1 January 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (3)
Pathologic Periprosthetic Fracture After Radial Head Arthroplasty
Case: We present 2 cases of pathologic periprosthetic radius fractures in the setting of osteolysis after radial head arthroplasty (RHA) with a porous-coated, press-fit implant. Both patients were managed with implant removal without subsequent instability. Although radiographic lucencies are common after RHA, progressive bone resorption can result in subsequent periprosthetic fractures. Conclusion: Although osteolysis after RHA is not always clinically significant, these cases demonstrate that this radiographic finding may indicate adverse clinical consequences. Surgeons who perform implant excision should be ready to address further instability as needed. Level of Evidence: Level V, case reports.
- 1 January 2022
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 12 (3)
Pathologic Periprosthetic Fracture After Radial Head Arthroplasty
Case: We present 2 cases of pathologic periprosthetic radius fractures in the setting of osteolysis after radial head arthroplasty (RHA) with a porous-coated, press-fit implant. Both patients were managed with implant removal without subsequent instability. Although radiographic lucencies are common after RHA, progressive bone resorption can result in subsequent periprosthetic fractures. Conclusion: Although osteolysis after RHA is not always clinically significant, these cases demonstrate that this radiographic finding may indicate adverse clinical consequences. Surgeons who perform implant excision should be ready to address further instability as needed. Level of Evidence: Level V, case reports.