Jianhong Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianhong Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Wei Li
Zhejiang University
2 shared publications - Kaiyu Wu
College of Energy Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication Wenjian Wu
Electric Power Research Institute of State Grid Zhejiang Electric Power Company Hangzhou , Zhejiang 310014, China
1 shared publication- Yifan Wu
The University of Sydney,Sydney,New South Wales,Australia
1 shared publication Zhenghao Gu
Electric Power Research Institute of State Grid Zhejiang Electric Power Company Hangzhou , Zhejiang 310014, China
1 shared publication- Zhiwei Mao
Electric Power Research Institute of State Grid Zhejiang Electric Power Company Hangzhou , Zhejiang 310014, China
1 shared publication
Latest Publications
- 13 January 2023
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 145 (6) , 1-25
Multi-Objective Optimization of Economy, Safety and Emissions for the Startup Scheduling of a Steam Turbine
With the rapid development of renewable energy, traditional power generation such as combined cycle unit needs to startup or change load quickly to balance the variability brought by renewable resources. In the combined cycle unit, the startup of steam turbine has a great influence on the whole set, and it is necessary to ensure safety, shorten the startup time, and reduce pollutant emissions. These optimization objectives are inter-related and have complex contradiction, which is the difficulty for multi-objective optimization. Costs function consisting of startup costs, fatigue life damage costs, pollutant emissions costs, and revenue gained from electricity is proposed to balance the contradiction more objectively. Finite exhaustive method (FEM) combining thermal-structural finite element calculation and multi-objective optimization is proposed for multi-objective startup process optimization, and its results are compared with those of minimum startup time and minimum fatigue life damage optimization. It can automatically search for a unique global optimal solution for engineering practice, rather than solution sets obtained by Pareto Optimality, which is beneficial for application in different combined cycle steam turbines and startup process. Multi-objective optimization scheduling shortens startup time from 105 to 93 min, reduces maximum stress from 493 MPa to 440 MPa, and reduces costs function by 66.6%. The comparison with the multi-objective optimization results of the response surface method (RSM) proves the reliability and validity of this method. The practical inspection results prove that the optimal scheduling is safe and effective.
- 13 January 2023
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 145 (6) , 1-25
Multi-Objective Optimization of Economy, Safety and Emissions for the Startup Scheduling of a Steam Turbine
With the rapid development of renewable energy, traditional power generation such as combined cycle unit needs to startup or change load quickly to balance the variability brought by renewable resources. In the combined cycle unit, the startup of steam turbine has a great influence on the whole set, and it is necessary to ensure safety, shorten the startup time, and reduce pollutant emissions. These optimization objectives are inter-related and have complex contradiction, which is the difficulty for multi-objective optimization. Costs function consisting of startup costs, fatigue life damage costs, pollutant emissions costs, and revenue gained from electricity is proposed to balance the contradiction more objectively. Finite exhaustive method (FEM) combining thermal-structural finite element calculation and multi-objective optimization is proposed for multi-objective startup process optimization, and its results are compared with those of minimum startup time and minimum fatigue life damage optimization. It can automatically search for a unique global optimal solution for engineering practice, rather than solution sets obtained by Pareto Optimality, which is beneficial for application in different combined cycle steam turbines and startup process. Multi-objective optimization scheduling shortens startup time from 105 to 93 min, reduces maximum stress from 493 MPa to 440 MPa, and reduces costs function by 66.6%. The comparison with the multi-objective optimization results of the response surface method (RSM) proves the reliability and validity of this method. The practical inspection results prove that the optimal scheduling is safe and effective.
- Open Access
Peak-Load-Regulation Nuclear Power Unit Fault Diagnosis Using Thermal Sensors Combined with Improved ICA-RF Algorithm
Owing to the fact that large-scale peak-load-regulation nuclear power turbine units’ thermal signal is greatly influenced by background noise and has non-stationary and nonlinear characteristics, this paper proposes a new fault diagnosis method for thermal sensors based on an improved independent component analysis (Improved-ICA) algorithm and random forest (RF) algorithm. This method is based on independent component analysis (ICA), which is not capable of extracting components independently. Therefore, we propose the use of the maximum approximate information negative entropy optimization model in order to improve the ICA algorithm’s independent principal component extraction ability and obtain better non-Gaussian physical source signal separation results. The improved ICA algorithm is used for the blind source separation of the thermal parameters of peak-load-regulation nuclear power units. A series of stationary physical source functions and a series of non-stationary noise signals are obtained. Then, according to the specific signal format and data volume of the nuclear power parameter signal, the network parameters of the random forest algorithm are determined, giving rise to the fault diagnosis model. Finally, the real-time operation data of an 1121 MW nuclear power unit are used to complete the training and fault diagnosis of the random forest network and analyze the diagnosis results. The results indicate that the model can effectively mine the abnormal sample points of thermal parameters and classify the fault type of the thermal sensor during peak load operation of the nuclear power unit. The accuracy rate is found to be at the threshold of 99%.
Open AccessPeak-Load-Regulation Nuclear Power Unit Fault Diagnosis Using Thermal Sensors Combined with Improved ICA-RF Algorithm
Owing to the fact that large-scale peak-load-regulation nuclear power turbine units’ thermal signal is greatly influenced by background noise and has non-stationary and nonlinear characteristics, this paper proposes a new fault diagnosis method for thermal sensors based on an improved independent component analysis (Improved-ICA) algorithm and random forest (RF) algorithm. This method is based on independent component analysis (ICA), which is not capable of extracting components independently. Therefore, we propose the use of the maximum approximate information negative entropy optimization model in order to improve the ICA algorithm’s independent principal component extraction ability and obtain better non-Gaussian physical source signal separation results. The improved ICA algorithm is used for the blind source separation of the thermal parameters of peak-load-regulation nuclear power units. A series of stationary physical source functions and a series of non-stationary noise signals are obtained. Then, according to the specific signal format and data volume of the nuclear power parameter signal, the network parameters of the random forest algorithm are determined, giving rise to the fault diagnosis model. Finally, the real-time operation data of an 1121 MW nuclear power unit are used to complete the training and fault diagnosis of the random forest network and analyze the diagnosis results. The results indicate that the model can effectively mine the abnormal sample points of thermal parameters and classify the fault type of the thermal sensor during peak load operation of the nuclear power unit. The accuracy rate is found to be at the threshold of 99%.