IKIgor Vladimirovich Khominets

Igor Vladimirovich Khominets

*This is an algorithmically generated author record based on publicly available information.

Igor Vladimirovich Khominets has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Military reconstructive surgery of the extremities. why this concept emerged and what it represents: a review

    by Andrey A. Maksimov, Artur A. Kerimov, Nikolay I. Nelin, Igor V. Khominets, Evgeniy A. Kukushko, Denis I. Vaskul, Vladimir D. Besedin, Natalya G. Shikhaleva, Denis V. Davydov, Leonid K. Brizhan, et al.

    The extensive use of explosive munitions in modern warfare has led to a change in the distribution of sanitary losses and to greater severity of organ and tissue injuries. Improvements in the medical evacuation system have resulted in the formation of a specific group of wounded patients, whose defining characteristic is the presence of extensive combined gunshot tissue defects of the extremities. In this context, there has arisen a need to refine the concept of medical care for the wounded and to define a new multidisciplinary field. Analysis of the scientific data on combat-related surgical trauma and the authors’ experience revealed discrepancies between established military medical doctrine and contemporary requirements for specialized surgical care. In this work, a new treatment concept and the term “military reconstructive surgery of the extremities” are proposed. The concept of military reconstructive surgery of the extremities represents a system of interrelated principles and methods for the diagnosis and treatment of patients with combat-related extremity injuries. The term “military reconstructive surgery of the extremities” denotes a set of interdependent and mutually conditioned actions aimed at providing specialized medical care to wounded patients with combat-related extremity injuries in order to achieve the maximum possible restoration of the anatomy and function of the damaged extremities. Military reconstructive surgery of the extremities constitutes a component of specialized surgical care that requires a multidisciplinary approach and a complex of specialized diagnostic and therapeutic equipment, and represents a logical continuation of military field surgery.


  • Open Access

    BIOMECHANICAL SUBSTANTIATION OF THE USE OF ROD EXTERNAL FIXATION DEVICES IN THE TREATMENT OF WOUNDED WITH GUNSHOT FRACTURES OF LONG BONES OF THE EXTREMITIES

    by A. A. Kerimov, I. V. Khominets, K. K. Bekshokov, O. V. Pimanchev

    Today, the treatment of wounded with gunshot fractures of long bones of the extremities is the most important task of military traumatology and orthopedics. In the context of armed conflicts of recent decades, the nature of military operations is constantly changing and the damaging effects of modern firearms and ammunition are increasing, which is why the treatment of this category of patients requires constant improvement. Traditionally, medical care for the wounded with fractures of long bones of the extremities consisted of timely primary surgical treatment and therapeutic and transport immobilization, which should preferably be performed by extrafocal osteosynthesis using rod external fixation devices (EFD). However, the existing versions and modifications of EFD have different biomechanical and ergonomic characteristics, which, in our opinion, require further revision in order to improve the quality of medical care for the wounded at the stages of medical evacuation. Objective: based on the analysis of biomechanical parameters, assess the stability of external fixation of bone fragments in the constructed loading models “bone – EFD” using various versions of rod EFD using the example of a diaphyseal comminuted fracture of the tibia (type C according to the AO classification). Materials and methods : the material for this study was a 3D printed model of the tibia, built on the basis of CT in the Mimics program. The model took into account spongy and cortical bone tissue. Then, in the SolidWorks automated design system, models of external fixation devices were built, which were then combined with the bone model. Next, a comminuted fracture of the bone diaphysis was formed, type C according to the AO classification. Modeling of the bone – external fixation device system loading was carried out in the Ansys finite element analysis system. Quantitative calculation of the biomechanical characteristics of external fixation was carried out using the finite element method (FE). Results and conclusions : based on the analysis of the biomechanical characteristics, it was revealed that the highest stability indicators for fixing a comminuted fracture are found in the rod external fixation device, the connecting nodes of which were made of titanium alloy. At the same time, the devices, the connecting units of which were made of other materials, demonstrated a sufficient degree of fixation during long loading cycles, without experiencing fatigue damage either in bone tissue or in the elements of the device, which confirms the possibility of using various modifications of rod EFDs in the treatment of comminuted, including gunshot, fractures of the diaphysis of long tubular bones in clinical practice.

  • Open Access

    Efficiency of using antibacterial coatings on titanium implants in the treatment of gunshot fractures

    by D. V. Davydov, L. K. Brizhan, A. A. Kerimov, I. V. Khominets, K. K. Bekshokov, А. A. Gritsyuk, E. A. Kukushk, V. D. Besedin

    Introduction High risk of infectious complications in gunshot wounds remains a pressing issue in military medicine. Analysis of the structure of sanitary losses shows that limb injuries account for 55 % to 81.4 %, with about 35 % of them accompanied by bone fractures. Performing operations for the final stabilization of these fractures under the conditions of primary microbial contamination is associated with a high risk of infectious complications. However, the use of antibacterial coatings on internal implants significantly reduces the risk of such complications.The purpose of the work, based on the analysis of Russian and foreign literary sources, is to determine the effectiveness of using antibacterial coatings on titanium implants for gunshot fractures.Materials and methods The search for scientific publications was carried out in the search engines eLibrary, PubMed and Connected Papers using the keywords: antibacterial coatings, gunshot fractures, implant-associated infection, internal osteosynthesis, infectious complications, antibacterial coating, gunshot fractures, infectious complications, peri-implant infection. The sources were selected based on the hypothesis of the possibility of using antibacterial coatings in clinical practice. The search depth was from 2009 to 2025.Results and discussion The existing systems for delivering antibacterial drugs to the surgical intervention area demonstrate high clinical efficacy in the prevention of peri-implant infection. To date, the most studied agents for creating coatings are metal ions, polymers, as well as composites containing antibacterial / antiseptic drugs. The most effective are multifunctional and intelligent coatings that have a combined effect on microbial biofilms due to their pronounced anti-adhesive and biocidal properties. There is a shortage of research on the use of multifunctional coatings in traumatological and orthopedic practice. There are no publications in the world literature devoted to the use of antibacterial coatings in the treatment of gunshot fractures and their consequences.Conclusion The use of polymer and multifunctional antibacterial coatings, hydrogels, as well as oxides of silver, iodine and zinc demonstrate high efficiency in the prevention of infectious complications after internal osteosynthesis, and, in our opinion, can be considered for use in clinical practice in the treatment of gunshot fractures of limb bones.


  • Open Access

    Sequential osteosynthesis in the context of modern armed conflicts

    by Artur Aslanovich Kerimov, Igor Vladimirovich Khominets, Sergey Nikolaevich Perekhodov, Nikolay Sergeevich Kozlov, Kazbek Kerimovich Bekshokov, Maksim Nikolaevich Nelin, Evgeniy Anatolyevich Kukushko, Vladimir Dmitrievich Besedin, Sergey Ivanovich Tverdokhlebov, Anna Ivanovna Kozelskaya

    BACKGROUND: Limb injuries remain the most prevalent combat injuries in modern armed conflicts, accounting for 55% to 75% of all cases. The transosseous compression-distraction osteosynthesis technique developed by Ilizarov has long been used in Russia to treat this patient population. However, given the current rate of mass casualty admissions to central military medical facilities, there is a growing need to improve treatment quality while shortening treatment time. Sequential internal osteosynthesis is one way for improving care. Antibiotic-coated implants reduce the risk of infectious complications during sequential osteosynthesis. AIM: This study aimed to assess the efficacy of sequential osteosynthesis in the treatment of gunshot fractures of long bones of the limbs in the current armed conflict setting, based on our clinical experience and global scientific data. METHODS: The study is based on an analysis of treatment outcomes in 320 patients with upper and lower limb injuries who received specialized medical care at the Department of Traumatology and Orthopedics of the N.N. Burdenko Main Military Clinical Hospital, Ministry of Defense of the Russian Federation. Patients were divided into three groups based on the osteosynthesis technique used. All patients were male, aged 18 to 59 years, with a mean age of 32.2 ± 9.02 years. Stepwise X-ray examinations were performed in all patients following osteosynthesis. Functional outcomes of humeral fracture treatment were assessed using the DASH score, whereas functional outcomes of femoral and tibial fracture treatment were evaluated using the Neer–Grantham–Shelton scale. RESULTS: The study included 90 patients (28.125%) with humeral fractures and 230 patients (71.875%) with lower limb injuries associated with femoral or tibial fractures. Shrapnel wounds and/or blast injuries predominated in 288 cases (90%). An intergroup comparison showed that antibiotic-coated implants significantly (p 0.0167) accelerated the transition from external to internal fixation and reduced the risk of infectious complications. CONCLUSION: Sequential osteosynthesis has proven to be an effective two-stage treatment for long bone fractures in wounded individuals. In the context of modern armed conflict, it is considered the primary approach to managing isolated and multiple uncomplicated gunshot fractures, provided that established guidelines are strictly followed. Furthermore, given the recent advances in traumatology and orthopedics, antibiotic-coated implants can be used to reduce the risk of infectious complications.


  • An algorithm for treating gunshot wounds and blast injuries to limbs with soft tissue defects

    by Moscow Fsbi Main Military Clinical Hospital Named Af ter Academician N.N. Burdenko Of The Ministry Of Defense Of Russia, A.A. Kerimov, A.A. Maksimov, S.N. Perekhodov, FSBEI HE Russian Universit y of Medicine of the Ministry of Health of the Russian Federation, V.D. Besedin, I.V. Khominets, E.A. Murzin

    The active modernization of weapons carried out by most countries of the world and the change in combat tactics have led to a change in the nature of combat trauma. In modern local armed conflicts, gunshot wounds and blast limb injuries are characterized by significant destruction and damage to soft tissues with extensive defects requiring reconstructive plastic replacement. Purpose: to increase the effectiveness of the treatment of limb gunshot wounds and blast lesions with soft tissue defects. Material and methods. The study included 90 patients with gunshot wounds and blast injuries with extensive soft tissue defects of the extremities. All the wounded were divided into 2 groups: the 1st group (control) included 50 (55.5%) of the wounded who had the traditional treatment method; the 2nd group (comparison) included 40 (44.5%) of the wounded who received the original algorithm for the treatment of gunshot wounds and blast limb lesions. Results. It was found that when using the presented algorithm, it was possible to reduce the number of complications of plastic surgery to 15% in group 2, while this figure in group 1 was 28%. Conclusions. The application of the presented algorithm for the treatment of gunshot wounds and blast lesions of limbs with extensive soft tissue defects can increase the effectiveness of wound treatment in case of combat surgical trauma by preparing the wound for reconstructive plastic surgery in the early stages (up to 30 days) with the use of methods of local physical impact.

  • Open Access

    Application of additive technologies in the treatment of patients with gunshot wounds of the elbow joint

    by Artur Aslanovich Kerimov, Evgenii Anatolevich Kukushko, Evgenii Andreevich Murzin, Igor E. Onnitsev, Igor Vladimirovich Khominets, Vladimir Dmitrievich Besedin, Anna Aleksandrovna Kucherenko, Denis Vladimirovich Davydod, Давыдов Денис Владимирович, Leonid Karlovich Brizhan, et al.

    BACKGROUND: Management of patients with upper extremity gunshot wounds that have destroyed the elbow joint is a major challenge in modern traumatic and orthopedic surgery. AIM: To assess medium-term surgical outcomes in patients with upper extremity gunshot wounds that have destroyed the elbow joint who received combination treatment using additive technology. MATERIALS AND METHODS: Between 2022 and 2024, 25 patients with upper extremity gunshot wounds that have destroyed the elbow were treated using additive technology in the Center for Traumatology and Orthopedics of the Burdenko Main Military Clinical Hospital of the Ministry of Defense of Russia. All patients were male, with a mean age of 34.5±7.82 years. The mean time from injury to elbow replacement surgery was 193±39 days. The range of motion in the elbow joint was assessed. The QuickDASH and the Oxford Elbow Score were used to subjectively assess treatment outcomes after 3 and 6 months. CT examinations were performed at each stage. RESULTS: A follow-up examination after 6 months showed an improvement in the range of motion in the majority of patients. The following criteria indicated a positive outcome: range of motion without limitations (Table 4, RF Government Decree No. 565 of July 4, 2013, On Approval of the Regulation on Military Medical Examination), QuickDASH score 45, and Oxford Elbow Score 70. The outcome was good in 17 (68%) patients and satisfactory in 5 (20%) patients. Three (12%) patients had postoperative complications (one patient’s elbow implant component was destroyed, and two patients developed deep periprosthetic infections), resulting in poor outcomes. Thus, the elbow joint function was successfully restored using additive technology in 22 (88%) patients. CONCLUSION: In patients with upper extremity gunshot wounds that have destroyed the elbow joint, additive technology rapidly and completely restores the upper extremity function. However, the long-term outcomes of this treatment need to be investigated further.

  • Reconstruction of total calcaneus gunshot defect with a free V-shaped iliac bone flap

    by S.V. Tereshchuk, V.A. Sukharev, A.A. Kerimov, E.A. Vasiliev, A.A. Gritsyuk, I.V. Khominets

    The hindfoot bears 80% of the body’s weight and provides a springy connection between the forefoot and the entire foot. Correction of hindfoot defects is a difficult objective, as it is associated with the need to restore the lost bone, soft tissues and connection of calcaneus with flexor muscles of the foot. In this article, we present clinical and radiological results of a new method for correction of total gunshot defect of calcaneus using a V-shaped iliac bone graft with skin platform and anterolateral thigh fasciocutaneous flap. Extensive hindfoot defect included total calcaneus defect, skin defect of plantar, posterior and lateral parts of the foot. We used surgical templates prepared by using of 3D technologies. Another feature of this case is inclusion of iliac bone graft in the distal end of vascular pedicle of anterolateral thigh fasciocutaneous flap. Four months later, CT revealed signs of consolidation of the graft fragments between themselves and foot bones. External fixator was removed. The goal of reconstructive surgery of calcaneus is restoring appropriate anatomical structures and creating conditions for the first phase of walking cycle, i.e. stepping on the heel and redistributing body weight on the entire foot. Various autologous, allogeneic and artificial plastic materials are used. In contrast to these techniques, V-shaped iliac crest graft makes it possible to restore not only height of calcaneus, but also width of its supporting surface. Moreover, we avoid the risk of complications in the donor area following transcendental size of iliac bone graft. The proposed technique provides effective correction of extensive hindfoot defects and total defects of calcaneus resulting from gunshot and mine-explosive wounds.

  • Evaluation of the effectiveness of using biodegradable implants based on magnesium oxide compared to titanium alternatives. Experimental study

    by Moscow Main Military Clinical Hospital Named After Academician N.N. Burdenko Russian Defense Ministry, D.V. Davydov, L.K. Brizhan’, A.A. Kerimov, I.V. Khominets, S.YU. Kalinin, A.A. Artemiev

    The issues of improving surgical implants used in treating patients with traumatological and orthopedic profiles continue to remain relevant. The development of a material not inferior in its elastic-strength properties to metal and that does not require further removal remains a reason for studying new samples that are inert during resorption. The purpose of this study was to experimentally explore and compare the bone tissue reaction to the introduction of titanium and magnesium oxide implants, as well as to study the state of magnesium oxide structures at different times after implantation. The material for the study was an implant based on magnesium oxide manufactured by the «MAGNEZIX» company. We operated on 30 rabbits based on the experimental laboratory of the Main Military Clinical Hospital named after academician N.N. Burdenko Russian Defense Ministry. The main group consisted of 10 rabbits, which were injected with a biodegradable screw made of a material based on magnesium oxide. The control group included 10 rabbits, which were injected with a titanium screw. In addition, another group of rabbits was studied. It included 10 young subjects who were injected with an implant based on magnesium oxide into the growth zone. Subjects were removed from the experiment one at a time at various stages. Then X-ray and histological assessment of the paraimplant zone were performed. As a result, the experiment showed that biomaterials based on magnesium oxide are bioinert, do not cause an inflammation reaction or osteolysis of the surrounding tissue, do not lead to the release of gas and the formation of a pathological cavity. During the introduction of magnesium-containing implants to young subjects, no pathological changes in bone tissue, deformities or stunting in the growth of the studied individuals were detected. Based on the obtained experimental data gathered for 6 months, it should be concluded that the material based on magnesium oxide is very promising and suitable for use in traumatology and orthopedics.