Vincenzo Manuel Marzullo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vincenzo Manuel Marzullo has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Luini
National Research Council
2 shared publications - Alexander A. Mironov
Department of Cell Biology, IFOM ETS—The AIRC Institute of Molecular Oncology, Via Adamello, 16, 20139 Milan, Italy
1 shared publication B. Corrado
ALDA s.r.l.
1 shared publication- Domenico Russo
Institute of Endotypes in Oncology, Metabolism and Immunology “G. Salvatore” (IEOMI) National Research Council Naples Italy
1 shared publication - Federica Liccardo
Cardiovascular Research Institute, Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94143
1 shared publication G. Coppola
Institute of Microelectronics and Microfluidics, National Research Council of Italy
1 shared publication
Latest Publications
- Open Access
- 3 September 2025
- Published by Springer Nature in EMBO Reports
- Vol. 26 (19) , 4742-4765
Cargoes move from cis to trans-Golgi compartments and concentrate in the TGN before exiting
The classical models of intra-Golgi transport envision a movement of cargoes from cis - to trans -Golgi, followed by their sorting at the trans -Golgi network (TGN). During this vectorial transport, the cargoes are processed by sequentially acting glycosylation enzymes. A number of studies challenged the vectorial transport model and proposed alternative transport routes bypassing either directional transport or the TGN. We have re-visited intra-Golgi transport using varied cargo synchronization protocols, employing both imaging and biochemical methods. We find that cargoes move vectorially across the Golgi stack and reach the TGN. Cell type-dependent variations in transport kinetics and the limited resolution of fluorescence microscopy could have influenced earlier discrepant interpretations. Further, we find that exit from TGN is a rate-limiting step leading to the accumulation of cargoes there before their monoexponential exit. These findings support an intriguing model of intra-Golgi transport, which involves classical vectorial transport across the Golgi stack followed by a non-maturation-based transport from the stack to the TGN.
- 3 September 2025
- Published by Springer Nature in EMBO Reports
- Vol. 26 (19) , 4742-4765
Open AccessCargoes move from cis to trans-Golgi compartments and concentrate in the TGN before exiting
The classical models of intra-Golgi transport envision a movement of cargoes from cis - to trans -Golgi, followed by their sorting at the trans -Golgi network (TGN). During this vectorial transport, the cargoes are processed by sequentially acting glycosylation enzymes. A number of studies challenged the vectorial transport model and proposed alternative transport routes bypassing either directional transport or the TGN. We have re-visited intra-Golgi transport using varied cargo synchronization protocols, employing both imaging and biochemical methods. We find that cargoes move vectorially across the Golgi stack and reach the TGN. Cell type-dependent variations in transport kinetics and the limited resolution of fluorescence microscopy could have influenced earlier discrepant interpretations. Further, we find that exit from TGN is a rate-limiting step leading to the accumulation of cargoes there before their monoexponential exit. These findings support an intriguing model of intra-Golgi transport, which involves classical vectorial transport across the Golgi stack followed by a non-maturation-based transport from the stack to the TGN.
- Open Access
Precision localization of cellular proteins with fluorescent Fab-based probes
Currently, a major technical limitation of microscopy based image analysis is the linkage error – which describes the distance between e.g. the target epitope of cellular protein to the fluorescence emitter, which position is finally detected in a microscope. With continuously improving resolution of today’s (super-resolution) microscopes, the linkage errors can severely hamper the correct interpretation of images and is usually introduced in experiments by the use of standard intracellular staining reagents such as fluorescently labelled antibodies. The linkage error of standard labelled antibodies is caused by the size of the antibody and the random distribution of fluorescent emitters on the antibody surface. Together, these two factors account for a fluorescence displacement of ~40nm when staining proteins by indirect immunofluorescence; and ~20nm when staining with fluorescently coupled primary antibodies. In this study, we describe a class of staining reagents that effectively reduce the linkage error by more than five-fold when compared to conventional staining techniques. These reagents, called Fluo-N-Fabs, consist of an antigen binding fragment of a full-length antibody (Fab / fragment antigen binding) that is selectively conjugated at the N-terminal amino group with fluorescent organic molecules, thereby reducing the distance between the fluorescent emitter and the protein target of the analysis. Fluo-N-Fabs also exhibit the capability to penetrate tissues and highly crowded cell compartments, thus allowing for the efficient detection of cellular epitopes of interest in a wide range of fixed samples. We believe this class of reagents realize an unmet need in cell biological super resolution imaging studies where the precise localization of the target of interest is crucial for the understanding of complex biological phenomena.
Open AccessPrecision localization of cellular proteins with fluorescent Fab-based probes
Currently, a major technical limitation of microscopy based image analysis is the linkage error – which describes the distance between e.g. the target epitope of cellular protein to the fluorescence emitter, which position is finally detected in a microscope. With continuously improving resolution of today’s (super-resolution) microscopes, the linkage errors can severely hamper the correct interpretation of images and is usually introduced in experiments by the use of standard intracellular staining reagents such as fluorescently labelled antibodies. The linkage error of standard labelled antibodies is caused by the size of the antibody and the random distribution of fluorescent emitters on the antibody surface. Together, these two factors account for a fluorescence displacement of ~40nm when staining proteins by indirect immunofluorescence; and ~20nm when staining with fluorescently coupled primary antibodies. In this study, we describe a class of staining reagents that effectively reduce the linkage error by more than five-fold when compared to conventional staining techniques. These reagents, called Fluo-N-Fabs, consist of an antigen binding fragment of a full-length antibody (Fab / fragment antigen binding) that is selectively conjugated at the N-terminal amino group with fluorescent organic molecules, thereby reducing the distance between the fluorescent emitter and the protein target of the analysis. Fluo-N-Fabs also exhibit the capability to penetrate tissues and highly crowded cell compartments, thus allowing for the efficient detection of cellular epitopes of interest in a wide range of fixed samples. We believe this class of reagents realize an unmet need in cell biological super resolution imaging studies where the precise localization of the target of interest is crucial for the understanding of complex biological phenomena.