O. V. Nemykina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
O. V. Nemykina has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- P. D. Andrienko
Запорожский национальный технический университет
3 shared publications - Dmitriy Alekseevskiy
National University Zaporizhzhia Polytechnic
2 shared publications - Olexander Blyzniakov
National University Zaporizhzhia Polytechnic
2 shared publications - A. A. Andrienko
Національний університет «Запорізька політехніка
1 shared publication I.YU. Nemudriy
1 shared publication- Richard Mokhnach
Національний університет «Запорізька політехніка
1 shared publication
Latest Publications
- 16 July 2025
- Published by Springer Nature
- p. 316-325
Efficacy Evaluation of High-Power Dual-System Wind Turbines
- 16 July 2025
- Published by Springer Nature
- p. 316-325
Efficacy Evaluation of High-Power Dual-System Wind Turbines
- Open Access
- 13 November 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2023 (6) , 44-53
EFFICIENCY ANALYSIS OF ELECTROMECHANICAL CONVERSION SYSTEMS OF WIND TURBINES WITH AERODYNAMIC MULTIPLICATION
In this article, we have considered the state of development of high-power horizontal wind turbines. The most common wind turbines for operation with variable wind flow speed usually include a frequency converter to ensure the compatibility of generator with network. It leads to decrease in the efficiency of wind energy conversion system, while the use of direct connection of the generator to the axis of wind wheel leads to a significant increase in the weight and cost of the generator. The wind turbine with aerodynamic multiplication is an alternative to such systems. Its prototype with 750 kW power is manufactured and studied in Ukraine. This wind energy conversion system with the synchronous or induction generators offers the property to generate energy under optimal condition with invariable rotational speed of generator rotor within the wide range of variable speed of wind flow. In this case, it is not necessary to apply the frequency converter that contributes to increasing the efficiency and reducing the cost of wind turbine. As shown, the relative performances of mass, cost and efficiency of generators in proposed system comparatively to conventional one depend on the multiplication factor (i.e. ratio of the rotational speeds of wind turbine and generator). When the power of wind turbines is from 750 to 2500 kW, the multiplication factor is within the limits of 10.72 to 4.75. The theoretical and experimental study shows that the wind turbines with aerodynamic multiplication can be competitive as compared to conventional horizontal wind turbines. This article is aimed to comparative analysis of the quantitative and qualitative characteristics of the equipment used in high-power horizontal wind turbines with direct connection of generators to the axis of wind turbine and in wind turbines with aerodynamic multiplication. References 27, tables 1, figures 6.
- 13 November 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2023 (6) , 44-53
Open AccessEFFICIENCY ANALYSIS OF ELECTROMECHANICAL CONVERSION SYSTEMS OF WIND TURBINES WITH AERODYNAMIC MULTIPLICATION
In this article, we have considered the state of development of high-power horizontal wind turbines. The most common wind turbines for operation with variable wind flow speed usually include a frequency converter to ensure the compatibility of generator with network. It leads to decrease in the efficiency of wind energy conversion system, while the use of direct connection of the generator to the axis of wind wheel leads to a significant increase in the weight and cost of the generator. The wind turbine with aerodynamic multiplication is an alternative to such systems. Its prototype with 750 kW power is manufactured and studied in Ukraine. This wind energy conversion system with the synchronous or induction generators offers the property to generate energy under optimal condition with invariable rotational speed of generator rotor within the wide range of variable speed of wind flow. In this case, it is not necessary to apply the frequency converter that contributes to increasing the efficiency and reducing the cost of wind turbine. As shown, the relative performances of mass, cost and efficiency of generators in proposed system comparatively to conventional one depend on the multiplication factor (i.e. ratio of the rotational speeds of wind turbine and generator). When the power of wind turbines is from 750 to 2500 kW, the multiplication factor is within the limits of 10.72 to 4.75. The theoretical and experimental study shows that the wind turbines with aerodynamic multiplication can be competitive as compared to conventional horizontal wind turbines. This article is aimed to comparative analysis of the quantitative and qualitative characteristics of the equipment used in high-power horizontal wind turbines with direct connection of generators to the axis of wind turbine and in wind turbines with aerodynamic multiplication. References 27, tables 1, figures 6.
- Open Access
- 1 January 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 11-16
RESEARCH OF OPERATING MODES OF CONDUCTORS IN POWER SUPPLY SYSTEMS OF CRANES WITH INDUCTION FEED, TAKING INTO ACCOUNT THE INFLUENCE OF HIGHER HARMONICS OF THE CURRENT
Purpose. Investigation of the influence of higher harmonics of current on current distribution, voltage and power losses in the supply systems of crane trolleys and development of a calculation method for practical use. Methodology. The analytical method and the results of the modeling method were used for research. Results. Analytical relationships have been obtained that make it possible to determine the current distribution, voltage and power losses in the systems of induction feeding of crane trolleys, taking into account the composition and amplitude of the higher harmonics of the current. Originality. For the first time, analytical dependences are obtained that take into account the effect of changing the trolley parameters on the frequency in the feed systems. Numerical values have been determined for the most commonly used induction feed systems for cranes. It is shown that with an increase in the cross-section of the feed bar there is a decrease in the main, and especially additional, losses. Practical value. Theoretical relationships have been obtained that can be used to calculate the optimization of induction feed systems in the presence of higher harmonic currents arising in power systems during operation of crane semiconductor controlled electric drives. References 13, tables 4, figures 6.
- 1 January 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 11-16
Open AccessRESEARCH OF OPERATING MODES OF CONDUCTORS IN POWER SUPPLY SYSTEMS OF CRANES WITH INDUCTION FEED, TAKING INTO ACCOUNT THE INFLUENCE OF HIGHER HARMONICS OF THE CURRENT
Purpose. Investigation of the influence of higher harmonics of current on current distribution, voltage and power losses in the supply systems of crane trolleys and development of a calculation method for practical use. Methodology. The analytical method and the results of the modeling method were used for research. Results. Analytical relationships have been obtained that make it possible to determine the current distribution, voltage and power losses in the systems of induction feeding of crane trolleys, taking into account the composition and amplitude of the higher harmonics of the current. Originality. For the first time, analytical dependences are obtained that take into account the effect of changing the trolley parameters on the frequency in the feed systems. Numerical values have been determined for the most commonly used induction feed systems for cranes. It is shown that with an increase in the cross-section of the feed bar there is a decrease in the main, and especially additional, losses. Practical value. Theoretical relationships have been obtained that can be used to calculate the optimization of induction feed systems in the presence of higher harmonic currents arising in power systems during operation of crane semiconductor controlled electric drives. References 13, tables 4, figures 6.