Eno Hysi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eno Hysi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Michael C. Kolios
Toronto Metropolitan University
4 shared publications - Agata A. Exner
Case Western Reserve University
1 shared publication - Ahmad Shahin
Doctoral School of Science and Technology, Lebanese University, Tripoli, Lebanon
1 shared publication - Ann Young
Division of Nephrology, St. Michael’s Hospital, Unity Health, University of Toronto, ON, Canada
1 shared publication Anoja Giles
Sunnybrook Research Institute,Physical Sciences,Toronto,Canada
1 shared publicationAvinash Naraiah Mukkala
Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, St. Michael’s Hospital, Unity Health Toronto, Toronto, ON, Canada
1 shared publication
Latest Publications
- 25 June 2025
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 282 (3) , 389-400
Mitochondrial Transplantation Reduces Injury and Improves Liver Function in a Porcine Model of Hemi-hepatic Ischemia/Reperfusion
Objective: To assess mitochondrial transplantation (MitoTx) via portal vein infusion to reduce liver ischemia-reperfusion injury (I/R) in a survival porcine model. Summary Background Data: MitoTx has been shown to alleviate I/R injury in various organs. Methods: Male Yorkshire pigs (38±1 kg) were subjected to 2 hours of ischemia in the left hemi-liver (left portal-triad clamping), and at the beginning of reperfusion (marked as t=0 h), animals received a 1-hour infusion of autologous mitochondria (MT, 7×10^9/kg) or saline (controls) via the portal vein. Liver tissue oxygen saturation (sO2) was assessed by photoacoustic imaging. Results: Twelve pigs (6 MitoTx vs. 6 controls) underwent 2-hour left hemi-liver I/R. All pigs recovered and were ambulatory at t=6 hours. MitoTx reduced peak AST levels at t=2 hours compared with controls (299.83±46.62 vs. 878.83±255.09 UI/L; P=0.049). At t=24 hours, MitoTx pigs had lowered necrosis area percentage (8.01±4.12 vs. 23.40±7.33 %; P=0.08) in left livers—all right lobes had 0% necrotic area. MitoTx pigs had shorter prothrombin time, plateauing around t=8 hours (12.9±0.3 vs. 14.1±0.1 s; P=0.003), faster lactate clearance (P=0.003] and from the bile [HR: 1.4, (1.1, 1.7); P=0.009] compared with controls. At t=6 hours, MitoTx pigs had decreased IL-6 (304±71 vs. 686±87 pg/mL; P=0.007). Photoacoustic imaging showed that MitoTx pigs had a better recovery of sO2 from baseline in left livers compared with controls (at t=30 min; −3.05±2.72 vs. −15.19±2.92 %; P=0.016). Conclusion: MitoTx reduces injury and improves liver function after prolonged liver I/R, showing promise for liver transplantation.
- 25 June 2025
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 282 (3) , 389-400
Mitochondrial Transplantation Reduces Injury and Improves Liver Function in a Porcine Model of Hemi-hepatic Ischemia/Reperfusion
Objective: To assess mitochondrial transplantation (MitoTx) via portal vein infusion to reduce liver ischemia-reperfusion injury (I/R) in a survival porcine model. Summary Background Data: MitoTx has been shown to alleviate I/R injury in various organs. Methods: Male Yorkshire pigs (38±1 kg) were subjected to 2 hours of ischemia in the left hemi-liver (left portal-triad clamping), and at the beginning of reperfusion (marked as t=0 h), animals received a 1-hour infusion of autologous mitochondria (MT, 7×10^9/kg) or saline (controls) via the portal vein. Liver tissue oxygen saturation (sO2) was assessed by photoacoustic imaging. Results: Twelve pigs (6 MitoTx vs. 6 controls) underwent 2-hour left hemi-liver I/R. All pigs recovered and were ambulatory at t=6 hours. MitoTx reduced peak AST levels at t=2 hours compared with controls (299.83±46.62 vs. 878.83±255.09 UI/L; P=0.049). At t=24 hours, MitoTx pigs had lowered necrosis area percentage (8.01±4.12 vs. 23.40±7.33 %; P=0.08) in left livers—all right lobes had 0% necrotic area. MitoTx pigs had shorter prothrombin time, plateauing around t=8 hours (12.9±0.3 vs. 14.1±0.1 s; P=0.003), faster lactate clearance (P=0.003] and from the bile [HR: 1.4, (1.1, 1.7); P=0.009] compared with controls. At t=6 hours, MitoTx pigs had decreased IL-6 (304±71 vs. 686±87 pg/mL; P=0.007). Photoacoustic imaging showed that MitoTx pigs had a better recovery of sO2 from baseline in left livers compared with controls (at t=30 min; −3.05±2.72 vs. −15.19±2.92 %; P=0.016). Conclusion: MitoTx reduces injury and improves liver function after prolonged liver I/R, showing promise for liver transplantation.
- 1 May 2025
- Published by American Physiological Society in Physiology
- Vol. 40 (3) , 224-232
Photoacoustic Imaging of Metabolic Activities across Biological Length Scales
Imaging is ubiquitous with biomedical research and discovery. This article surveys the role of imaging in our understanding of metabolism and introduces photoacoustic imaging as a compelling candidate for providing high-resolution, label-free, and real-time insights into metabolic processes. As a rapidly evolving modality, photoacoustics holds promising preclinical and clinical potential in imaging of metabolism as well as metabolism-related changes.
- 1 May 2025
- Published by American Physiological Society in Physiology
- Vol. 40 (3) , 224-232
Photoacoustic Imaging of Metabolic Activities across Biological Length Scales
Imaging is ubiquitous with biomedical research and discovery. This article surveys the role of imaging in our understanding of metabolism and introduces photoacoustic imaging as a compelling candidate for providing high-resolution, label-free, and real-time insights into metabolic processes. As a rapidly evolving modality, photoacoustics holds promising preclinical and clinical potential in imaging of metabolism as well as metabolism-related changes.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Canadian Journal of Kidney Health and Disease
- Vol. 8
Evolving Medical Imaging Techniques for the Assessment of Delayed Graft Function: A Narrative Review
Purpose of review: Delayed graft function (DGF) is a significant complication that contributes to poorer graft function and shortened graft survival. In this review, we sought to evaluate the current and emerging role of medical imaging modalities in the assessment of DGF and how it may guide clinical management. Sources of information: PubMed, Google Scholar, and ClinicalTrial.gov up until February 2021. Methods: This narrative review first examined the pathophysiology of DGF and current clinical management. We then summarized relevant studies that utilized medical imaging to assess posttransplant renal complications, namely, DGF. We focused our attention on noninvasive, evolving imaging modalities with the greatest potential for clinical translation, including contrast-enhanced ultrasound (CEUS) and multiparametric magnetic resonance imaging (MRI). Key findings: A kidney biopsy in the setting of DGF can be used to assess the degree of ischemic renal injury and to rule out acute rejection. Biopsies are accompanied by complications and may be limited by sampling bias. Early studies on CEUS and MRI have shown their potential to distinguish between the 2 most common causes of DGF (acute tubular necrosis and acute rejection), but they have generally included only small numbers of patients and have not kept pace with more recent technical advances of these imaging modalities. There remains unharnessed potential with CEUS and MRI, and more robust clinical studies are needed to better evaluate their role in the current era. Limitations: The adaptation of emerging approaches for imaging DGF will depend on additional clinical trials to study the feasibility and diagnostic test characteristics of a given modality. This is limited by access to devices, technical competence, and the need for interdisciplinary collaborations to ensure that such studies are well designed to appropriately inform clinical decision-making.
- 1 January 2021
- Published by SAGE Publications in Canadian Journal of Kidney Health and Disease
- Vol. 8
Open AccessEvolving Medical Imaging Techniques for the Assessment of Delayed Graft Function: A Narrative Review
Purpose of review: Delayed graft function (DGF) is a significant complication that contributes to poorer graft function and shortened graft survival. In this review, we sought to evaluate the current and emerging role of medical imaging modalities in the assessment of DGF and how it may guide clinical management. Sources of information: PubMed, Google Scholar, and ClinicalTrial.gov up until February 2021. Methods: This narrative review first examined the pathophysiology of DGF and current clinical management. We then summarized relevant studies that utilized medical imaging to assess posttransplant renal complications, namely, DGF. We focused our attention on noninvasive, evolving imaging modalities with the greatest potential for clinical translation, including contrast-enhanced ultrasound (CEUS) and multiparametric magnetic resonance imaging (MRI). Key findings: A kidney biopsy in the setting of DGF can be used to assess the degree of ischemic renal injury and to rule out acute rejection. Biopsies are accompanied by complications and may be limited by sampling bias. Early studies on CEUS and MRI have shown their potential to distinguish between the 2 most common causes of DGF (acute tubular necrosis and acute rejection), but they have generally included only small numbers of patients and have not kept pace with more recent technical advances of these imaging modalities. There remains unharnessed potential with CEUS and MRI, and more robust clinical studies are needed to better evaluate their role in the current era. Limitations: The adaptation of emerging approaches for imaging DGF will depend on additional clinical trials to study the feasibility and diagnostic test characteristics of a given modality. This is limited by access to devices, technical competence, and the need for interdisciplinary collaborations to ensure that such studies are well designed to appropriately inform clinical decision-making.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 227-230
Radiation-enhanced nanobubble therapy: Monitoring treatment effects using photoacoustic imaging
In this work we demonstrate the potential of using nanobubbles (NBs) as radiation therapy enhancers for maximizing tumoral cell death. Photoacoustic (PA) imaging can be used to probe the mechanism of action of this treatment due to its ability to examine the oxygenation of tumors. In vivo experiments were performed in mice bearing prostate cancer tumors and the NB therapies were compared with conventional microbubble (MB) treatments combined with radiation. Our preliminary results show that NB combined with a single dose of 8 Gy radiation induce 40% tumor cell death compared to 20% observed with MB treatments. PA imaging suggest that NBs have an extravascular effect.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 227-230
Radiation-enhanced nanobubble therapy: Monitoring treatment effects using photoacoustic imaging
In this work we demonstrate the potential of using nanobubbles (NBs) as radiation therapy enhancers for maximizing tumoral cell death. Photoacoustic (PA) imaging can be used to probe the mechanism of action of this treatment due to its ability to examine the oxygenation of tumors. In vivo experiments were performed in mice bearing prostate cancer tumors and the NB therapies were compared with conventional microbubble (MB) treatments combined with radiation. Our preliminary results show that NB combined with a single dose of 8 Gy radiation induce 40% tumor cell death compared to 20% observed with MB treatments. PA imaging suggest that NBs have an extravascular effect.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 214-218
K-nearest neighbor classification for the differentiation between freshly excised and decellularized rat kidneys using envelope statistics
Decellularization is a technique that permits the removal of cells from intact tissue while preserving the extracellular matrix structure. It has many applications in the fields of regenerative medicine and tissue engineering. Evaluating the efficiency of cell removal from the tissue non-invasively remains a challenge. This work aims to investigate the use of the k-nearest neighbor classifier using envelope statistics, for the differentiation between freshly excised and decellularized rat kidneys. Two probability distributions were fitted with the histogram of the ultrasound backscatter signal envelope intensities: the Rayleigh and Generalized Gamma. Three fit parameters were extractedfrom these distributions andfed into the classifier. The classification resulted in an AUC of 0.93 and an accuracy of 92%. Future work include incorporating other distributions to further improve the accuracy of this classifier, as well as investigating other classifiers of interest.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 214-218
K-nearest neighbor classification for the differentiation between freshly excised and decellularized rat kidneys using envelope statistics
Decellularization is a technique that permits the removal of cells from intact tissue while preserving the extracellular matrix structure. It has many applications in the fields of regenerative medicine and tissue engineering. Evaluating the efficiency of cell removal from the tissue non-invasively remains a challenge. This work aims to investigate the use of the k-nearest neighbor classifier using envelope statistics, for the differentiation between freshly excised and decellularized rat kidneys. Two probability distributions were fitted with the histogram of the ultrasound backscatter signal envelope intensities: the Rayleigh and Generalized Gamma. Three fit parameters were extractedfrom these distributions andfed into the classifier. The classification resulted in an AUC of 0.93 and an accuracy of 92%. Future work include incorporating other distributions to further improve the accuracy of this classifier, as well as investigating other classifiers of interest.
- 3 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8943, 894367-894367-6
Identification of red blood cell rouleaux formation using photoacoustic ultrasound spectroscopy
- 3 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8943, 894367-894367-6
Identification of red blood cell rouleaux formation using photoacoustic ultrasound spectroscopy
- 4 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8581, 85813W
Photoacoustic radio-frequency spectroscopy (PA-RFS): A technique for monitoring absorber size and concentration
A photoacoustic technique for monitoring absorber size and concentration is presented. The technique relies on analyzing the power spectra of the radio-frequency signals and taking into account the receiving transducer response in order to remove system dependencies. By normalizing the power spectra, parameters derived from ultrasound tissue characterization (spectral slope and midband fit) can be obtained. Tissue mimicking phantoms were constructed using black polystyrene beads of various sizes and concentrations as absorbers. The spectral slope decreased by 0.63 dB/MHz when the size of the particle increased from 1 μm to 10 μm at every bead concentration. The midband fit was ~4 dB higher for the 10 μm particle and increased linearly with concentration. These results suggest that photoacoustic radiofrequency spectroscopy (PA-RFS) can potentially monitor changes in absorber size and concentration thus improving the ability of photoacoustic imaging to distinguish structural tissue variations.
- 4 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8581, 85813W
Photoacoustic radio-frequency spectroscopy (PA-RFS): A technique for monitoring absorber size and concentration
A photoacoustic technique for monitoring absorber size and concentration is presented. The technique relies on analyzing the power spectra of the radio-frequency signals and taking into account the receiving transducer response in order to remove system dependencies. By normalizing the power spectra, parameters derived from ultrasound tissue characterization (spectral slope and midband fit) can be obtained. Tissue mimicking phantoms were constructed using black polystyrene beads of various sizes and concentrations as absorbers. The spectral slope decreased by 0.63 dB/MHz when the size of the particle increased from 1 μm to 10 μm at every bead concentration. The midband fit was ~4 dB higher for the 10 μm particle and increased linearly with concentration. These results suggest that photoacoustic radiofrequency spectroscopy (PA-RFS) can potentially monitor changes in absorber size and concentration thus improving the ability of photoacoustic imaging to distinguish structural tissue variations.