Hongcheng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hongcheng Liu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Hung Yi Lee
Department of Industrial and Systems Engineering University of Florida 32611 Gainesville FL USA
4 shared publications - Charles Hernandez
Department of Industrial and Systems Engineering University of Florida 32611 Gainesville FL USA
3 shared publications - Xiaojing Ye
Department of Mathematics and Statistics, Georgia State University, Atlanta, GA 30303 USA
3 shared publications - Yu Yang
Department of Industrial and Systems Engineering, University of Florida, Gainesville, Florida 32611; and Center for Applied Optimization, University of Florida, Gainesville, Florida 32611
3 shared publications Yunmei Chen
3 shared publications- Bo Lu
Department of Radiation Oncology, College of Medicine, University of Florida, Gainesville, FL, USA
2 shared publications
Latest Publications
- 11 August 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (17) , 175004
Performance assessment of variant UNet-based deep-learning dose engines for MR-Linac-based prostate IMRT plans
Objective . UNet-based deep-learning (DL) architectures are promising dose engines for traditional linear accelerator (Linac) models. Current UNet-based engines, however, were designed differently with various strategies, making it challenging to fairly compare the results from different studies. The objective of this study is to thoroughly evaluate the performance of UNet-based models on magnetic-resonance (MR)-Linac-based intensity-modulated radiation therapy (IMRT) dose calculations. Approach . The UNet-based models, including the standard-UNet, cascaded-UNet, dense-dilated-UNet, residual-UNet, HD-UNet, and attention-aware-UNet, were implemented. The model input is patient CT and IMRT field dose in water, and the output is patient dose calculated by DL model. The reference dose was calculated by the Monaco Monte Carlo module. Twenty training and ten test cases of prostate patients were included. The accuracy of the DL-calculated doses was measured using gamma analysis, and the calculation efficiency was evaluated by inference time. Results . All the studied models effectively corrected low-accuracy doses in water to high-accuracy patient doses in a magnetic field. The gamma passing rates between reference and DL-calculated doses were over 86% (1%/1 mm), 98% (2%/2 mm), and 99% (3%/3 mm) for all the models. The inference times ranged from 0.03 (graphics processing unit) to 7.5 (central processing unit) seconds. Each model demonstrated different strengths in calculation accuracy and efficiency; Res-UNet achieved the highest accuracy, HD-UNet offered high accuracy with the fewest parameters but the longest inference, dense-dilated-UNet was consistently accurate regardless of model levels, standard-UNet had the shortest inference but relatively lower accuracy, and the others showed average performance. Therefore, the best-performing model would depend on the specific clinical needs and available computational resources. Significance . The feasibility of using common UNet-based models for MR-Linac-based dose calculations has been explored in this study. By using the same model input type, patient training data, and computing environment, a fair assessment of the models’ performance was present.
- 11 August 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (17) , 175004
Performance assessment of variant UNet-based deep-learning dose engines for MR-Linac-based prostate IMRT plans
Objective . UNet-based deep-learning (DL) architectures are promising dose engines for traditional linear accelerator (Linac) models. Current UNet-based engines, however, were designed differently with various strategies, making it challenging to fairly compare the results from different studies. The objective of this study is to thoroughly evaluate the performance of UNet-based models on magnetic-resonance (MR)-Linac-based intensity-modulated radiation therapy (IMRT) dose calculations. Approach . The UNet-based models, including the standard-UNet, cascaded-UNet, dense-dilated-UNet, residual-UNet, HD-UNet, and attention-aware-UNet, were implemented. The model input is patient CT and IMRT field dose in water, and the output is patient dose calculated by DL model. The reference dose was calculated by the Monaco Monte Carlo module. Twenty training and ten test cases of prostate patients were included. The accuracy of the DL-calculated doses was measured using gamma analysis, and the calculation efficiency was evaluated by inference time. Results . All the studied models effectively corrected low-accuracy doses in water to high-accuracy patient doses in a magnetic field. The gamma passing rates between reference and DL-calculated doses were over 86% (1%/1 mm), 98% (2%/2 mm), and 99% (3%/3 mm) for all the models. The inference times ranged from 0.03 (graphics processing unit) to 7.5 (central processing unit) seconds. Each model demonstrated different strengths in calculation accuracy and efficiency; Res-UNet achieved the highest accuracy, HD-UNet offered high accuracy with the fewest parameters but the longest inference, dense-dilated-UNet was consistently accurate regardless of model levels, standard-UNet had the shortest inference but relatively lower accuracy, and the others showed average performance. Therefore, the best-performing model would depend on the specific clinical needs and available computational resources. Significance . The feasibility of using common UNet-based models for MR-Linac-based dose calculations has been explored in this study. By using the same model input type, patient training data, and computing environment, a fair assessment of the models’ performance was present.
- 19 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (1) , 015002
An ultra-fast deep-learning-based dose engine for prostate VMAT via knowledge distillation framework with limited patient data
Objective . Deep-learning (DL)-based dose engines have been developed to alleviate the intrinsic compromise between the calculation accuracy and efficiency of the traditional dose calculation algorithms. However, current DL-based engines typically possess high computational complexity and require powerful computing devices. Therefore, to mitigate their computational burdens and broaden their applicability to a clinical setting where resource-limited devices are available, we proposed a compact dose engine via knowledge distillation (KD) framework that offers an ultra-fast calculation speed with high accuracy for prostate Volumetric Modulated Arc Therapy (VMAT). Approach . The KD framework contains two sub-models: a large pre-trained teacher and a small to-be-trained student. The student receives knowledge transferred from the teacher for better generalization. The trained student serves as the final engine for dose calculation. The model input is patient computed tomography and VMAT dose in water, and the output is DL-calculated patient dose. The ground-truth \dose was computed by the Monte Carlo module of the Monaco treatment planning system. Twenty and ten prostate cases were included for model training and assessment, respectively. The model’s performance (teacher/student/student-only) was evaluated by Gamma analysis and inference efficiency. Main results . The dosimetric comparisons (input/DL-calculated/ground-truth doses) suggest that the proposed engine can effectively convert low-accuracy doses in water to high-accuracy patient doses. The Gamma passing rate (2%/2 mm, 10% threshold) between the DL-calculated and ground-truth doses was 98.64 ± 0.62% (teacher), 98.13 ± 0.76% (student), and 96.95 ± 1.02% (student-only). The inference time was 16 milliseconds (teacher) and 11 milliseconds (student/student-only) using a graphics processing unit device, while it was 936 milliseconds (teacher) and 374 milliseconds (student/student-only) using a central processing unit device. Significance . With the KD framework, a compact dose engine can achieve comparable accuracy to that of a larger one. Its compact size reduces the computational burdens and computing device requirements, and thus such an engine can be more clinically applicable.
- 19 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (1) , 015002
An ultra-fast deep-learning-based dose engine for prostate VMAT via knowledge distillation framework with limited patient data
Objective . Deep-learning (DL)-based dose engines have been developed to alleviate the intrinsic compromise between the calculation accuracy and efficiency of the traditional dose calculation algorithms. However, current DL-based engines typically possess high computational complexity and require powerful computing devices. Therefore, to mitigate their computational burdens and broaden their applicability to a clinical setting where resource-limited devices are available, we proposed a compact dose engine via knowledge distillation (KD) framework that offers an ultra-fast calculation speed with high accuracy for prostate Volumetric Modulated Arc Therapy (VMAT). Approach . The KD framework contains two sub-models: a large pre-trained teacher and a small to-be-trained student. The student receives knowledge transferred from the teacher for better generalization. The trained student serves as the final engine for dose calculation. The model input is patient computed tomography and VMAT dose in water, and the output is DL-calculated patient dose. The ground-truth \dose was computed by the Monte Carlo module of the Monaco treatment planning system. Twenty and ten prostate cases were included for model training and assessment, respectively. The model’s performance (teacher/student/student-only) was evaluated by Gamma analysis and inference efficiency. Main results . The dosimetric comparisons (input/DL-calculated/ground-truth doses) suggest that the proposed engine can effectively convert low-accuracy doses in water to high-accuracy patient doses. The Gamma passing rate (2%/2 mm, 10% threshold) between the DL-calculated and ground-truth doses was 98.64 ± 0.62% (teacher), 98.13 ± 0.76% (student), and 96.95 ± 1.02% (student-only). The inference time was 16 milliseconds (teacher) and 11 milliseconds (student/student-only) using a graphics processing unit device, while it was 936 milliseconds (teacher) and 374 milliseconds (student/student-only) using a central processing unit device. Significance . With the KD framework, a compact dose engine can achieve comparable accuracy to that of a larger one. Its compact size reduces the computational burdens and computing device requirements, and thus such an engine can be more clinically applicable.
- 1 November 2022
- Published by Springer Nature in Chinese Annals of Mathematics, Series B
- Vol. 43 (6) , 1049-1070
Extrapolated Smoothing Descent Algorithm for Constrained Nonconvex and Nonsmooth Composite Problems
- 1 November 2022
- Published by Springer Nature in Chinese Annals of Mathematics, Series B
- Vol. 43 (6) , 1049-1070
Extrapolated Smoothing Descent Algorithm for Constrained Nonconvex and Nonsmooth Composite Problems
- 1 November 2022
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in Operations Research
- Vol. 70 (6) , 3176-3197
High-Dimensional Learning Under Approximate Sparsity with Applications to Nonsmooth Estimation and Regularized Neural Networks
In “High-Dimensional Learning Under Approximate Sparsity with Applications to Nonsmooth Estimation and Regularized Neural Networks,” Liu, Ye, and Lee study a model fitting problem where there are much fewer data than problem dimensions. Of their particular focus are the scenarios where the commonly imposed sparsity assumption is relaxed, and the usual condition of the restricted strong convexity is absent. The results show that generalization performance can still be ensured in such settings, even if the problem dimensions grow exponentially. The authors further study the sample complexities of high-dimensional nonsmooth estimation and neural networks. Particularly for the latter, it is shown that, with explicit regularization, a neural network is provably generalizable, even if the sample size is only poly-logarithmic in the number of fitting parameters.
- 1 November 2022
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in Operations Research
- Vol. 70 (6) , 3176-3197
High-Dimensional Learning Under Approximate Sparsity with Applications to Nonsmooth Estimation and Regularized Neural Networks
In “High-Dimensional Learning Under Approximate Sparsity with Applications to Nonsmooth Estimation and Regularized Neural Networks,” Liu, Ye, and Lee study a model fitting problem where there are much fewer data than problem dimensions. Of their particular focus are the scenarios where the commonly imposed sparsity assumption is relaxed, and the usual condition of the restricted strong convexity is absent. The results show that generalization performance can still be ensured in such settings, even if the problem dimensions grow exponentially. The authors further study the sample complexities of high-dimensional nonsmooth estimation and neural networks. Particularly for the latter, it is shown that, with explicit regularization, a neural network is provably generalizable, even if the sample size is only poly-logarithmic in the number of fitting parameters.
- 5 October 2022
- Published by Elsevier in Expert Systems with Applications
- Vol. 213
Training generalizable quantized deep neural nets
- 5 October 2022
- Published by Elsevier in Expert Systems with Applications
- Vol. 213
Training generalizable quantized deep neural nets
- Open Access
Learnable Descent Algorithm for Nonsmooth Nonconvex Image Reconstruction
We propose a general learning based framework for solving nonsmooth and nonconvex image reconstruction problems. We model the regularization function as the composition of the $l_{2,1}$ norm and a smooth but nonconvex feature mapping parametrized as a deep convolutional neural network. We develop a provably convergent descent-type algorithm to solve the nonsmooth nonconvex minimization problem by leveraging the Nesterov's smoothing technique and the idea of residual learning, and learn the network parameters such that the outputs of the algorithm match the references in training data. Our method is versatile as one can employ various modern network structures into the regularization, and the resulting network inherits the guaranteed convergence of the algorithm. We also show that the proposed network is parameter-efficient and its performance compares favorably to the state-of-the-art methods in a variety of image reconstruction problems in practice.Open AccessLearnable Descent Algorithm for Nonsmooth Nonconvex Image Reconstruction
We propose a general learning based framework for solving nonsmooth and nonconvex image reconstruction problems. We model the regularization function as the composition of the $l_{2,1}$ norm and a smooth but nonconvex feature mapping parametrized as a deep convolutional neural network. We develop a provably convergent descent-type algorithm to solve the nonsmooth nonconvex minimization problem by leveraging the Nesterov's smoothing technique and the idea of residual learning, and learn the network parameters such that the outputs of the algorithm match the references in training data. Our method is versatile as one can employ various modern network structures into the regularization, and the resulting network inherits the guaranteed convergence of the algorithm. We also show that the proposed network is parameter-efficient and its performance compares favorably to the state-of-the-art methods in a variety of image reconstruction problems in practice. - 15 July 2022
- Published by Springer Nature in Journal of Global Optimization
- Vol. 85 (2) , 257-282
Regularized sample average approximation for high-dimensional stochastic optimization under low-rankness
- 15 July 2022
- Published by Springer Nature in Journal of Global Optimization
- Vol. 85 (2) , 257-282
Regularized sample average approximation for high-dimensional stochastic optimization under low-rankness
- 7 June 2022
- Published by Wiley in Medical Physics
- Vol. 49 (7) , 4335-4352
A practical algorithm for VMAT optimization using column generation techniques
Purpose As a challenging but important optimization problem, the inverse planning for volumetric modulated arc therapy (VMAT) has attracted much research attention. The column generation (CG) type method is so far one of the most effective solution schemes. However, it often relies on simplifications leading to significant gaps between the output and the actual feasible plan. This paper presents a novel column generation (NCG) approach to push the planning results substantially closer to practice. Methods The proposed NCG algorithm is equipped with multiple new quality-enhancing and computation-facilitating modules as below: (1) Flexible constraints are enabled on both dose rates and treatment time to adapt to machine capabilities as well as planner's preferences, respectively; (2) a cross-control-point intermediate aperture simulation is incorporated to better conform to the underlying physics; (3) new pricing and pruning subroutines are adopted to achieve better optimization outputs. To evaluate the effectiveness of this NCG, five VMAT plans, that is, three prostate cases and two head-and-neck cases, were computed using proposed NCG. The planning results were compared with those yielded by a historical benchmark planning scheme. Results The NCG generated plans of significantly better quality than the benchmark planning algorithm. For prostate cases, NCG plans satisfied all planning target volume (PTV) criteria whereas CG plans failed on D10% criteria of PTVs for over 9 Gy or more on all cases. For head-and-neck cases, again, NCG plans satisfied all PTVs criteria while CG plans failed on D10% criteria of PTVs for over 3 Gy or more on all cases as well as the max dose criteria of both cord and brain stem for over 13 Gy on one case. Moreover, the pruning scheme was found to be effective in enhancing the optimization quality. Conclusions The proposed NCG inherits the computational advantages of the traditional CG, while capturing a more realistic characterization of the machine capability and underlying physics. The output solutions of the NCG are substantially closer to practical implementation.
- 7 June 2022
- Published by Wiley in Medical Physics
- Vol. 49 (7) , 4335-4352
A practical algorithm for VMAT optimization using column generation techniques
Purpose As a challenging but important optimization problem, the inverse planning for volumetric modulated arc therapy (VMAT) has attracted much research attention. The column generation (CG) type method is so far one of the most effective solution schemes. However, it often relies on simplifications leading to significant gaps between the output and the actual feasible plan. This paper presents a novel column generation (NCG) approach to push the planning results substantially closer to practice. Methods The proposed NCG algorithm is equipped with multiple new quality-enhancing and computation-facilitating modules as below: (1) Flexible constraints are enabled on both dose rates and treatment time to adapt to machine capabilities as well as planner's preferences, respectively; (2) a cross-control-point intermediate aperture simulation is incorporated to better conform to the underlying physics; (3) new pricing and pruning subroutines are adopted to achieve better optimization outputs. To evaluate the effectiveness of this NCG, five VMAT plans, that is, three prostate cases and two head-and-neck cases, were computed using proposed NCG. The planning results were compared with those yielded by a historical benchmark planning scheme. Results The NCG generated plans of significantly better quality than the benchmark planning algorithm. For prostate cases, NCG plans satisfied all planning target volume (PTV) criteria whereas CG plans failed on D10% criteria of PTVs for over 9 Gy or more on all cases. For head-and-neck cases, again, NCG plans satisfied all PTVs criteria while CG plans failed on D10% criteria of PTVs for over 3 Gy or more on all cases as well as the max dose criteria of both cord and brain stem for over 13 Gy on one case. Moreover, the pruning scheme was found to be effective in enhancing the optimization quality. Conclusions The proposed NCG inherits the computational advantages of the traditional CG, while capturing a more realistic characterization of the machine capability and underlying physics. The output solutions of the NCG are substantially closer to practical implementation.