Thomas Reuter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Reuter has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Andreas Grundmann
ICM – Institut Chemnitzer Maschinen- und Anlagenbau e. V. ; Otto-Schmerbach-Straße 19, Hochhaus 6. Etage , Chemnitz ; Germany
2 shared publications- Christoph Lischer
Equine Clinic, Veterinary Hospital, School of Veterinary Medicine, Freie Universität Berlin, Oertzenweg 19b, 14163 Berlin, Germany
2 shared publications - Guido Fritsch
Leibniz Institute for Zoo and Wildlife Research, Forschungsverbund Berlin e.V., 10315 Berlin, Germany
2 shared publications - Jennifer Gernhardt
Equine Clinic, Freie Universität Berlin, Oertzenweg 19b, 14163 Berlin, Germany
2 shared publications Jens Schmidt
ICM – Institut Chemnitzer Maschinen- und Anlagenbau e. V. ; Otto-Schmerbach-Straße 19, Hochhaus 6. Etage , Chemnitz ; Germany
2 shared publications- Kathrin Mählmann
Equine Clinic Freie Universität Berlin Berlin Germany
2 shared publications
Latest Publications
- 13 May 2026
- Published by Wiley in Equine Veterinary Journal
Novel imaging protocol enables myelography of the cervical vertebral column using computed tomography with flexion and extension comparable to x‐ray
Background: Radiographic myelography is the traditional diagnostic method for detecting cervical spinal cord compression in horses but it is limited by superimposition and restriction to sagittal plane imaging. Computed tomography (CT) and CT myelography overcome many of these limitations yet previous CT protocols have not allowed dynamic imaging in flexion and extension comparable to radiographs. Objectives: To describe and evaluate a novel CT myelography protocol that enables imaging of the equine cervical vertebral column (C 2/3 to C 7 /T 1 ) in flexion, neutral, and extension, and to compare intervertebral angle measurements with those obtained from radiographic myelography. Study Design: Prospective clinical study. Methods: Eight horses with clinical signs related to the cervical vertebral column underwent CT myelography and radiographic myelography under general anaesthesia. A mobile gantry CT system combined with a custom support platform enabled controlled repositioning of the cervical vertebral column. Intervertebral angles (C 2/3 to C 6 /T 1 ) were measured in flexion, neutral, and extension by three blinded image reviewers. Agreement between modalities was assessed using ANOVA, Bland–Altman plot, and concordance correlation coefficients. Results: The entire dynamic CT myelography protocol was completed within 45 min. Across all positions and cervical segments, no statistically significant differences were found between CT and radiographic myelography angle measurements ( p > 0.01). All horses recovered uneventfully from anaesthesia, and no contrast‐related adverse effects were observed. Main Limitations: Small sample size and the absence of repeated intra‐observer measurements. Intervertebral angles served as a proxy for motion but did not directly assess the degree of spinal cord compression. Conclusions: Dynamic CT myelography is feasible, safe, and provides positional sensitivity comparable to radiographic myelography, while overcoming the limitations of superimposition and enabling multiplanar evaluation. This novel protocol offers a reliable diagnostic alternative for assessing cervical spinal pathology in horses and allows complete coverage of the cervical vertebral column from C 2 to T 1 .
- 13 May 2026
- Published by Wiley in Equine Veterinary Journal
Novel imaging protocol enables myelography of the cervical vertebral column using computed tomography with flexion and extension comparable to x‐ray
Background: Radiographic myelography is the traditional diagnostic method for detecting cervical spinal cord compression in horses but it is limited by superimposition and restriction to sagittal plane imaging. Computed tomography (CT) and CT myelography overcome many of these limitations yet previous CT protocols have not allowed dynamic imaging in flexion and extension comparable to radiographs. Objectives: To describe and evaluate a novel CT myelography protocol that enables imaging of the equine cervical vertebral column (C 2/3 to C 7 /T 1 ) in flexion, neutral, and extension, and to compare intervertebral angle measurements with those obtained from radiographic myelography. Study Design: Prospective clinical study. Methods: Eight horses with clinical signs related to the cervical vertebral column underwent CT myelography and radiographic myelography under general anaesthesia. A mobile gantry CT system combined with a custom support platform enabled controlled repositioning of the cervical vertebral column. Intervertebral angles (C 2/3 to C 6 /T 1 ) were measured in flexion, neutral, and extension by three blinded image reviewers. Agreement between modalities was assessed using ANOVA, Bland–Altman plot, and concordance correlation coefficients. Results: The entire dynamic CT myelography protocol was completed within 45 min. Across all positions and cervical segments, no statistically significant differences were found between CT and radiographic myelography angle measurements ( p > 0.01). All horses recovered uneventfully from anaesthesia, and no contrast‐related adverse effects were observed. Main Limitations: Small sample size and the absence of repeated intra‐observer measurements. Intervertebral angles served as a proxy for motion but did not directly assess the degree of spinal cord compression. Conclusions: Dynamic CT myelography is feasible, safe, and provides positional sensitivity comparable to radiographic myelography, while overcoming the limitations of superimposition and enabling multiplanar evaluation. This novel protocol offers a reliable diagnostic alternative for assessing cervical spinal pathology in horses and allows complete coverage of the cervical vertebral column from C 2 to T 1 .
- Open Access
Ex Vivo Computed Tomographic Morphometry and Motion of the Native and Fractured Equine Accessory Carpal Bone
The accessory carpal bone (ACB) is an important component of the equine carpus and a clinically relevant site of fracture, yet its detailed morphology and motion characteristics remain incompletely characterized. The objectives of this ex vivo study were to characterize the three-dimensional morphometry of the native ACB using computed tomography (CT), to assess its kinematics during carpal flexion and extension using dynamic 3D CT, and to evaluate fragment behavior following a standardized vertical fracture. Twelve equine forelimbs underwent CT imaging in the neutral carpal position, maximal flexion, and maximal extension before and after standardized osteotomy simulating a vertical plane fracture. Morphometric measurements included dorsopalmar width, lateromedial thickness, proximodistal length, and radii of medial concavity and lateral convexity. The ACB exhibited consistent geometry among specimens of comparable size. Dynamic imaging revealed independent physiological motion relative to the other carpal bones of the ACB, characterized by medial movement of its medial concave surface toward the caudal aspect of the radius during flexion. Following fracture creation, widening of the fracture gap and proximal displacement of the palmar fragment occurred predominantly in flexion, whereas the neutral carpal position and maximal extension promoted fracture gap closure and distal displacement. These findings improve understanding of ACB morphology and biomechanics and may have implications for fracture pathogenesis and surgical fixation strategies.
Open AccessEx Vivo Computed Tomographic Morphometry and Motion of the Native and Fractured Equine Accessory Carpal Bone
The accessory carpal bone (ACB) is an important component of the equine carpus and a clinically relevant site of fracture, yet its detailed morphology and motion characteristics remain incompletely characterized. The objectives of this ex vivo study were to characterize the three-dimensional morphometry of the native ACB using computed tomography (CT), to assess its kinematics during carpal flexion and extension using dynamic 3D CT, and to evaluate fragment behavior following a standardized vertical fracture. Twelve equine forelimbs underwent CT imaging in the neutral carpal position, maximal flexion, and maximal extension before and after standardized osteotomy simulating a vertical plane fracture. Morphometric measurements included dorsopalmar width, lateromedial thickness, proximodistal length, and radii of medial concavity and lateral convexity. The ACB exhibited consistent geometry among specimens of comparable size. Dynamic imaging revealed independent physiological motion relative to the other carpal bones of the ACB, characterized by medial movement of its medial concave surface toward the caudal aspect of the radius during flexion. Following fracture creation, widening of the fracture gap and proximal displacement of the palmar fragment occurred predominantly in flexion, whereas the neutral carpal position and maximal extension promoted fracture gap closure and distal displacement. These findings improve understanding of ACB morphology and biomechanics and may have implications for fracture pathogenesis and surgical fixation strategies.
- Open Access
- 23 March 2026
- Published by Elsevier in Procedia Computer Science
- Vol. 277, 860-869
AI-Assisted Dismantling of Electric Vehicle Batteries – A Case Study on Technology Networking
- 23 March 2026
- Published by Elsevier in Procedia Computer Science
- Vol. 277, 860-869
Open AccessAI-Assisted Dismantling of Electric Vehicle Batteries – A Case Study on Technology Networking
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 309-310
P39 - Development of a universal instrument system for locking intramedullary nails
In large animals, fractures of the upper long tubular bones such as forearm and humerus as well as lower and upper leg, continue to represent a major surgical challenge. Fixing these fractures with implanted nails has proven to be difficult and requires a high level of X-ray monitoring. Therefore, a camera-marker system was developed without the need for X-ray monitoring during drilling. The results showed that 8 of 10 implants could be securely fixed. However, the described method has great potential in both veterinary and human medicine and does not require X-ray exposure.
- 1 January 2025
- Published by AMA Service GmbH
- p. 309-310
Open AccessP39 - Development of a universal instrument system for locking intramedullary nails
In large animals, fractures of the upper long tubular bones such as forearm and humerus as well as lower and upper leg, continue to represent a major surgical challenge. Fixing these fractures with implanted nails has proven to be difficult and requires a high level of X-ray monitoring. Therefore, a camera-marker system was developed without the need for X-ray monitoring during drilling. The results showed that 8 of 10 implants could be securely fixed. However, the described method has great potential in both veterinary and human medicine and does not require X-ray exposure.
- 20 October 2024
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 119 (10) , 742-748
Fertigungsprozessanalyse eines mittels Innenhochdruck-Umformung hergestellten Bauteils
Series manufacturers in the field of hydroforming do not always have the necessary database for predictive maintenance, especially for the production of complex hydroformed components. Small and medium-sized companies in particular often lack the resources to acquire, process and profitably utilize these data sets under production conditions. The IHU processes that occur in practice are usually highly complex, both in terms of geometry and against the background of additional process steps (punching, plunging). This results in large amounts of data and complex data analyses, which are reflected in the data processing costs. A data analysis is to be carried out on the basis of a complex hydroforming process and its additional benefit for quality management and predictive maintenance is to be explained.
- 20 October 2024
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 119 (10) , 742-748
Fertigungsprozessanalyse eines mittels Innenhochdruck-Umformung hergestellten Bauteils
Series manufacturers in the field of hydroforming do not always have the necessary database for predictive maintenance, especially for the production of complex hydroformed components. Small and medium-sized companies in particular often lack the resources to acquire, process and profitably utilize these data sets under production conditions. The IHU processes that occur in practice are usually highly complex, both in terms of geometry and against the background of additional process steps (punching, plunging). This results in large amounts of data and complex data analyses, which are reflected in the data processing costs. A data analysis is to be carried out on the basis of a complex hydroforming process and its additional benefit for quality management and predictive maintenance is to be explained.
- 7 September 2024
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 119 (9) , 624-632
Vorausschauende Instandhaltung und Effizienzbewertung von Niederspannungsmotoren
The consumption of electric drives in industry and manufacturing accounts for almost two-fifths of all electricity in Germany. Electric motors are thus considered to play a key role in energy savings. Energy savings are particularly high in the power range between 0.75 kW and 40 kW, since this is where most operating hours occur each year. At same time, in addition to energy savings, the maintenance of electric drives also plays a decisive role, as sudden failures can result in high costs due to production downtime or repairs. Against this background, a universally applicable condition monitoring system has been developed that allows electrical performance parameters to be analyzed in a simple and compact way in an industrial environment. The aim of this article is to show the added value of electrical power measurement for energy saving and maintenance planning in mechanical glass processing.
- 7 September 2024
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 119 (9) , 624-632
Vorausschauende Instandhaltung und Effizienzbewertung von Niederspannungsmotoren
The consumption of electric drives in industry and manufacturing accounts for almost two-fifths of all electricity in Germany. Electric motors are thus considered to play a key role in energy savings. Energy savings are particularly high in the power range between 0.75 kW and 40 kW, since this is where most operating hours occur each year. At same time, in addition to energy savings, the maintenance of electric drives also plays a decisive role, as sudden failures can result in high costs due to production downtime or repairs. Against this background, a universally applicable condition monitoring system has been developed that allows electrical performance parameters to be analyzed in a simple and compact way in an industrial environment. The aim of this article is to show the added value of electrical power measurement for energy saving and maintenance planning in mechanical glass processing.
- 1 October 2022
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 117 (10) , 659-666
Entwicklung eines Condition-Monitoring-Systems für Niederspannungsmotoren
Der Verbrauch von elektrischen Antrieben in der Industrie und dem verarbeitenden Gewerbe beträgt in Deutschland fast zwei Fünftel des gesamten Stromes. Somit werden den Elektromotoren eine Schlüsselrolle bei der Energieeinsparung zugeschrieben. Besonders hoch liegt die Energieeinsparung im Leistungsbereich zwischen 0,75 kW und 40 kW, da hier die meisten Betriebsstunden im Jahr anfallen. Gleichzeitig spielt neben der Energieeinsparung auch die Instandhaltung von elektrischen Antrieben eine entscheidende Rolle, da bei plötzlichen Ausfällen hohe Kosten durch Produktionsausfälle oder Reparaturen entstehen können. Um beiden Kriterien gerecht zu werden, wurde ein universell einsetzbares Condition-Monitoring-System entwickelt. Unter Anwendung der integrierten Schwingungsmessung konnten aus unterschiedlichen Belastungs- und Schadensfällen und den daraus ermittelten Kennwerten Vorhersagemodelle und Trendanalysen abgeleitet werden.
- 1 October 2022
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 117 (10) , 659-666
Entwicklung eines Condition-Monitoring-Systems für Niederspannungsmotoren
Der Verbrauch von elektrischen Antrieben in der Industrie und dem verarbeitenden Gewerbe beträgt in Deutschland fast zwei Fünftel des gesamten Stromes. Somit werden den Elektromotoren eine Schlüsselrolle bei der Energieeinsparung zugeschrieben. Besonders hoch liegt die Energieeinsparung im Leistungsbereich zwischen 0,75 kW und 40 kW, da hier die meisten Betriebsstunden im Jahr anfallen. Gleichzeitig spielt neben der Energieeinsparung auch die Instandhaltung von elektrischen Antrieben eine entscheidende Rolle, da bei plötzlichen Ausfällen hohe Kosten durch Produktionsausfälle oder Reparaturen entstehen können. Um beiden Kriterien gerecht zu werden, wurde ein universell einsetzbares Condition-Monitoring-System entwickelt. Unter Anwendung der integrierten Schwingungsmessung konnten aus unterschiedlichen Belastungs- und Schadensfällen und den daraus ermittelten Kennwerten Vorhersagemodelle und Trendanalysen abgeleitet werden.
- 1 May 2022
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 117 (5) , 275-282
Entwicklung eines Überwachungs- und Servicemanagementsystems für Sterilisations- und Schredderanlagen
Die Menge an toxischen Abfällen, die in Krankenhäusern und medizinischen Einrichtungen anfällt, steigt stetig an. Zwar stehen zentrale Entsorgungs- bzw. Betreiberlösungen zur Beseitigung von toxischen Abfällen in hochentwickelten Industrieländern zur Verfügung – dies gilt jedoch nicht für Entwicklungs- und Schwellenländer. Mögliche Gründe hierfür sind der nicht zu unterschätzende logistische Aufwand, der einer zentralen Entsorgungsstraße entgegensteht, sowie die fehlende Qualifikation benötigter Fachkräfte zur Wartung und Reparatur derartiger Anlagen. Um dieser Problematik künftig zu begegnen, wurde ein intelligentes Überwachungs- und Servicemanagementsystem für kompakte Sterilisations- und Schredderanlagen konzipiert. Unter Anwendung der entwickelten Methodik kann das Instandhaltungslevel von einem klassisch reaktiv geführten Service hin zu einem prädiktiven Service durch Fehlerklassifizierungen aus Expertenwissen sowie Vorhersagemodellen aus Maschinen- und Sensordaten gesteigert werden.
- 1 May 2022
- Published by Walter de Gruyter GmbH in Zeitschrift für wirtschaftlichen Fabrikbetrieb
- Vol. 117 (5) , 275-282
Entwicklung eines Überwachungs- und Servicemanagementsystems für Sterilisations- und Schredderanlagen
Die Menge an toxischen Abfällen, die in Krankenhäusern und medizinischen Einrichtungen anfällt, steigt stetig an. Zwar stehen zentrale Entsorgungs- bzw. Betreiberlösungen zur Beseitigung von toxischen Abfällen in hochentwickelten Industrieländern zur Verfügung – dies gilt jedoch nicht für Entwicklungs- und Schwellenländer. Mögliche Gründe hierfür sind der nicht zu unterschätzende logistische Aufwand, der einer zentralen Entsorgungsstraße entgegensteht, sowie die fehlende Qualifikation benötigter Fachkräfte zur Wartung und Reparatur derartiger Anlagen. Um dieser Problematik künftig zu begegnen, wurde ein intelligentes Überwachungs- und Servicemanagementsystem für kompakte Sterilisations- und Schredderanlagen konzipiert. Unter Anwendung der entwickelten Methodik kann das Instandhaltungslevel von einem klassisch reaktiv geführten Service hin zu einem prädiktiven Service durch Fehlerklassifizierungen aus Expertenwissen sowie Vorhersagemodellen aus Maschinen- und Sensordaten gesteigert werden.
- Open Access
- 1 October 2021
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 7 (2) , 355-358
Biphasic parameter identification of 3D scaffold-free cartilage transplants (SFCT) from stress relaxation compression tests using an optimized 3D FE-based method with tension-compression nonlinearity
Cartilage constructs produced by SFCTtechnology provide promising opportunities to restore cartilage defects. Mechanical parameters of soft tissues are explicit markers for quantitative tissue characterization. In this study, we present a biphasic 3D-FE-based method to determine the biomechanical properties of SFCT from stress relaxation compression tests (ε = 20 %, t = 3400 s) whereby cartilaginous tissue is modeled as a biphasic material with tension-compression nonlinearity (BMTCN). The FE-model computation was optimized by exploiting the axial symmetry and mesh resolution. The R² of the fit results varies between 0.970 and 0.983. The Young’s and fiber modulus determined from SFCT are 37-times and 5-times lower than from native articular cartilage, respectively. Permeability, on the other hand, is 11-times higher than from native articular cartilage.
- 1 October 2021
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 7 (2) , 355-358
Open AccessBiphasic parameter identification of 3D scaffold-free cartilage transplants (SFCT) from stress relaxation compression tests using an optimized 3D FE-based method with tension-compression nonlinearity
Cartilage constructs produced by SFCTtechnology provide promising opportunities to restore cartilage defects. Mechanical parameters of soft tissues are explicit markers for quantitative tissue characterization. In this study, we present a biphasic 3D-FE-based method to determine the biomechanical properties of SFCT from stress relaxation compression tests (ε = 20 %, t = 3400 s) whereby cartilaginous tissue is modeled as a biphasic material with tension-compression nonlinearity (BMTCN). The FE-model computation was optimized by exploiting the axial symmetry and mesh resolution. The R² of the fit results varies between 0.970 and 0.983. The Young’s and fiber modulus determined from SFCT are 37-times and 5-times lower than from native articular cartilage, respectively. Permeability, on the other hand, is 11-times higher than from native articular cartilage.