Chongxue Bie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chongxue Bie has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Peter C. M. van Zijl
F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, USA
7 shared publications- Yang Zhou
Chinese Academy of Sciences
7 shared publications - Nirbhay Narayan Yadav
Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
4 shared publications - Chao Zou
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences 1068 Xueyuan Avenue
3 shared publications - Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
3 shared publications - Lin Chen
Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College Xiamen University Xiamen China
3 shared publications
Latest Publications
- 14 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
GRACE ‐ MORE : A Motion‐Resolved Golden‐Angle Radial CEST MRI Technique for Free‐Breathing Abdominal Imaging
Purpose: To develop a motion‐resolved acquisition and reconstruction framework for motion‐robust and spectrally reliable abdominal CEST imaging under free‐breathing conditions. Theory and Methods: A framework termed Golden‐angle RAdial CEST MRI with MOtion‐REsolved reconstruction (GRACE‐MORE) was developed to improve acquisition, respiratory‐phase binning, and reconstruction. An interleaved steady‐state saturation module with golden‐angle radial sampling was adopted to enhance saturation efficiency and ensure uniform k‐space coverage. Respiratory‐phase binning was performed using a self‐gated strategy, in which respiratory amplitude and phase were extracted from central k‐space via principal component analysis, followed by hybrid empirical mode decomposition‐continuous wavelet transform sorting to correct baseline drift and irregular breathing. Reconstruction was performed using a deep unrolled network constrained by low‐rank and sparsity priors, which incorporated a modified U‐Net with channel attention and a sliding‐window grouping scheme to capture spatio‐spectral correlations across saturation offsets. Results: Validation on simulated, preclinical, and clinical datasets demonstrated more than a threefold improvement in binning accuracy compared with conventional methods. GRACE‐MORE reduced reconstruction error, yielded a higher structural similarity index and peak signal‐to‐noise ratio in simulations, and achieved improved anatomical fidelity, effective motion suppression, and up to a fourfold increase in Z‐spectral signal‐to‐noise ratio in vivo. Conclusion: GRACE‐MORE enables motion‐robust and spectrally reliable abdominal CEST imaging under free‐breathing conditions.
- 14 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
GRACE ‐ MORE : A Motion‐Resolved Golden‐Angle Radial CEST MRI Technique for Free‐Breathing Abdominal Imaging
Purpose: To develop a motion‐resolved acquisition and reconstruction framework for motion‐robust and spectrally reliable abdominal CEST imaging under free‐breathing conditions. Theory and Methods: A framework termed Golden‐angle RAdial CEST MRI with MOtion‐REsolved reconstruction (GRACE‐MORE) was developed to improve acquisition, respiratory‐phase binning, and reconstruction. An interleaved steady‐state saturation module with golden‐angle radial sampling was adopted to enhance saturation efficiency and ensure uniform k‐space coverage. Respiratory‐phase binning was performed using a self‐gated strategy, in which respiratory amplitude and phase were extracted from central k‐space via principal component analysis, followed by hybrid empirical mode decomposition‐continuous wavelet transform sorting to correct baseline drift and irregular breathing. Reconstruction was performed using a deep unrolled network constrained by low‐rank and sparsity priors, which incorporated a modified U‐Net with channel attention and a sliding‐window grouping scheme to capture spatio‐spectral correlations across saturation offsets. Results: Validation on simulated, preclinical, and clinical datasets demonstrated more than a threefold improvement in binning accuracy compared with conventional methods. GRACE‐MORE reduced reconstruction error, yielded a higher structural similarity index and peak signal‐to‐noise ratio in simulations, and achieved improved anatomical fidelity, effective motion suppression, and up to a fourfold increase in Z‐spectral signal‐to‐noise ratio in vivo. Conclusion: GRACE‐MORE enables motion‐robust and spectrally reliable abdominal CEST imaging under free‐breathing conditions.
- 8 April 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (5) , e70280
Noninvasive Mapping of Creatine Kinase Metabolism in Human Muscle Using pH‐Insensitive PCrCEST MRI at 3 and 5 T
Phosphocreatine (PCr) recovery after exercise reflects creatine kinase (CK) metabolism and is a key marker of muscle energetics. However, current chemical exchange saturation transfer (CEST)–based PCr imaging (PCrCEST) remains limited by pH‐dependent contrast. Here, we present a pH‐insensitive PCrCEST strategy that minimizes pH‐related signal variability, enabling more reliable in vivo quantification during exercise, when tissue pH may change. Theoretical derivation, simulations, and phantom studies confirmed that PCrCEST signals varied by less than 20% across the physiological pH range when the saturation radial frequency (γ B 1 ) matches the guanidinium proton exchange rate. Under this optimized B 1 condition, kinetic simulations further show that the PCrCEST‐derived recovery time constant ( τ PCr ) closely follows expected behavior even during dynamic pH changes. The pH‐insensitive strategy was implemented at both 3 and 5 T and assessed in human calf muscle during plantar flexion exercise. These results demonstrate that pH‐insensitive PCrCEST enabled robust mapping of muscle CK metabolism. The availability of pH‐insensitive CEST mapping improves the potential of CEST not only for exercise measurements but also for broader clinical translation.
- 8 April 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (5) , e70280
Noninvasive Mapping of Creatine Kinase Metabolism in Human Muscle Using pH‐Insensitive PCrCEST MRI at 3 and 5 T
Phosphocreatine (PCr) recovery after exercise reflects creatine kinase (CK) metabolism and is a key marker of muscle energetics. However, current chemical exchange saturation transfer (CEST)–based PCr imaging (PCrCEST) remains limited by pH‐dependent contrast. Here, we present a pH‐insensitive PCrCEST strategy that minimizes pH‐related signal variability, enabling more reliable in vivo quantification during exercise, when tissue pH may change. Theoretical derivation, simulations, and phantom studies confirmed that PCrCEST signals varied by less than 20% across the physiological pH range when the saturation radial frequency (γ B 1 ) matches the guanidinium proton exchange rate. Under this optimized B 1 condition, kinetic simulations further show that the PCrCEST‐derived recovery time constant ( τ PCr ) closely follows expected behavior even during dynamic pH changes. The pH‐insensitive strategy was implemented at both 3 and 5 T and assessed in human calf muscle during plantar flexion exercise. These results demonstrate that pH‐insensitive PCrCEST enabled robust mapping of muscle CK metabolism. The availability of pH‐insensitive CEST mapping improves the potential of CEST not only for exercise measurements but also for broader clinical translation.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 301-310
Rapid 3D Saturation Transfer Imaging for Simultaneous Phosphocreatine and Glycogen Mapping in Human Muscle
Objective: Phosphocreatine (PCr) and glycogen are key metabolites underpinning the skeletal muscle contractions. Simultaneous 3D imaging of these metabolites is valuable for understanding heterogeneous energetic events. While saturation transfer (ST) MRI can detect metabolites, 3D ST acquisition generally requires long scan times. We developed a rapid, high-resolution 3D scanning scheme for simultaneous quantification of PCr and glycogen. Methods: A 3D sequence was implemented on a 5 T MR scanner, using a continuous-wave saturation pulse and golden-angle stack-of-stars readouts. A patch-based low-rank algorithm was incorporated to reduce scan time. The sensitivity of sequence to concentration variations was validated in phantom experiments, and metabolite distribution was assessed in vivo. Furthermore, exercise protocols were employed to investigate metabolic heterogeneity. Results: The optimized acquisition strategy reduced the scan time to 26.7% of full sampling. Phantom studies showed a linear correlation between contrast signals and metabolite concentrations, in-vivo studies demonstrated uniform PCr and glycogen distribution across slices. Post-exercise, PCr and glycogen depletion was clearly observed. Conclusion and Significance: The 3D rapid ST imaging framework achieves 100 mm coverage of skeletal muscle in 11.2 minutes, showing the potential to monitor muscle physiological processes.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 301-310
Rapid 3D Saturation Transfer Imaging for Simultaneous Phosphocreatine and Glycogen Mapping in Human Muscle
Objective: Phosphocreatine (PCr) and glycogen are key metabolites underpinning the skeletal muscle contractions. Simultaneous 3D imaging of these metabolites is valuable for understanding heterogeneous energetic events. While saturation transfer (ST) MRI can detect metabolites, 3D ST acquisition generally requires long scan times. We developed a rapid, high-resolution 3D scanning scheme for simultaneous quantification of PCr and glycogen. Methods: A 3D sequence was implemented on a 5 T MR scanner, using a continuous-wave saturation pulse and golden-angle stack-of-stars readouts. A patch-based low-rank algorithm was incorporated to reduce scan time. The sensitivity of sequence to concentration variations was validated in phantom experiments, and metabolite distribution was assessed in vivo. Furthermore, exercise protocols were employed to investigate metabolic heterogeneity. Results: The optimized acquisition strategy reduced the scan time to 26.7% of full sampling. Phantom studies showed a linear correlation between contrast signals and metabolite concentrations, in-vivo studies demonstrated uniform PCr and glycogen distribution across slices. Post-exercise, PCr and glycogen depletion was clearly observed. Conclusion and Significance: The 3D rapid ST imaging framework achieves 100 mm coverage of skeletal muscle in 11.2 minutes, showing the potential to monitor muscle physiological processes.
- Open Access
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 676-688
Brain temperature mapping based on chemical exchange saturation transfer signal at 2 ppm
Background: Brain temperature signifies the thermal homeostasis of the tissue, and may serve as a marker for neuroprotective therapy. Currently, it remains challenging to map the human brain temperature with high spatial resolution. The thermal dependence of chemical exchange saturation transfer (CEST) effects of endogenous labile protons may provide a promising mechanism for the absolute brain temperature imaging. In this study, we aimed to investigate the temperature dependency of the CEST effect of creatine (CrCEST), and contemplate its feasibility for brain temperature mapping. Methods: Creatine (Cr) was selected as the endogenous agent to probe the brain temperature. Proof-of-concept phantom experiments were first conducted using a 400 MHz nuclear magnetic resonance (NMR) spectrometer and a 5.0 T magnetic resonance (MR) scanner at various temperatures. A multi-pool Lorentzian fitting model was utilized to quantify the apparent chemical shift, amplitude, linewidth, and integral of CrCEST peak at around 2 ppm. Regression analysis was performed to estimate the thermal response of these CrCEST parameters. Finally, the temperature mapping of ex vivo swine brain tissues was conducted based on the CEST signal at 2 ppm (CEST@2ppm). Results: A robust linear correlation between the apparent chemical shift of CrCEST and temperature was identified in the in vitro phantom experiments (+0.005 ppm/℃, Pex vivo swine brain tissue, a comparable temperature dependency of the apparent chemical shift of CEST@2ppm peak was found (+0.008 ppm/℃), confirming the utility of this approach for mapping brain temperature. Conclusions: The CEST-based approach proposed in this study suggests a path toward label-free brain thermometry in vivo at high resolution and may be potentially applied in other tissues such as muscle and kidney.
- 1 January 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (1) , 676-688
Open AccessBrain temperature mapping based on chemical exchange saturation transfer signal at 2 ppm
Background: Brain temperature signifies the thermal homeostasis of the tissue, and may serve as a marker for neuroprotective therapy. Currently, it remains challenging to map the human brain temperature with high spatial resolution. The thermal dependence of chemical exchange saturation transfer (CEST) effects of endogenous labile protons may provide a promising mechanism for the absolute brain temperature imaging. In this study, we aimed to investigate the temperature dependency of the CEST effect of creatine (CrCEST), and contemplate its feasibility for brain temperature mapping. Methods: Creatine (Cr) was selected as the endogenous agent to probe the brain temperature. Proof-of-concept phantom experiments were first conducted using a 400 MHz nuclear magnetic resonance (NMR) spectrometer and a 5.0 T magnetic resonance (MR) scanner at various temperatures. A multi-pool Lorentzian fitting model was utilized to quantify the apparent chemical shift, amplitude, linewidth, and integral of CrCEST peak at around 2 ppm. Regression analysis was performed to estimate the thermal response of these CrCEST parameters. Finally, the temperature mapping of ex vivo swine brain tissues was conducted based on the CEST signal at 2 ppm (CEST@2ppm). Results: A robust linear correlation between the apparent chemical shift of CrCEST and temperature was identified in the in vitro phantom experiments (+0.005 ppm/℃, Pex vivo swine brain tissue, a comparable temperature dependency of the apparent chemical shift of CEST@2ppm peak was found (+0.008 ppm/℃), confirming the utility of this approach for mapping brain temperature. Conclusions: The CEST-based approach proposed in this study suggests a path toward label-free brain thermometry in vivo at high resolution and may be potentially applied in other tissues such as muscle and kidney.
- Open Access
- 30 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
In vivo imaging of glycogen in human muscle
Probing regional glycogen metabolism in humans non-invasively has been challenging due to a lack of sensitive approaches. Here we studied human muscle glycogen dynamics post-exercise with a spatial resolution of millimeters and temporal resolution of minutes, using relayed nuclear Overhauser effect (glycoNOE) MRI. Data at 5T showed a homogeneous distribution of glycogen in resting muscle, with an average concentration of 99 ± 13 mM. After plantar flexion exercise following fasting with recovery under fasting conditions, the calf muscle showed spatially heterogeneous glycogen depletion and repletion kinetics that correlated with the severity of this depletion. Three types of regional glycogen kinetics were observed: (i) single exponential repletion (type a); (ii) biphasic recovery of rapid repletion followed by additional depletion (type b); (iii) biphasic recovery where continued depletion is followed by an exponential recovery (type c). The study of the complex patterns of glycogen kinetics suggests that glycogen breakdown may be quantitatively important during the initial recovery.
- 30 December 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Open AccessIn vivo imaging of glycogen in human muscle
Probing regional glycogen metabolism in humans non-invasively has been challenging due to a lack of sensitive approaches. Here we studied human muscle glycogen dynamics post-exercise with a spatial resolution of millimeters and temporal resolution of minutes, using relayed nuclear Overhauser effect (glycoNOE) MRI. Data at 5T showed a homogeneous distribution of glycogen in resting muscle, with an average concentration of 99 ± 13 mM. After plantar flexion exercise following fasting with recovery under fasting conditions, the calf muscle showed spatially heterogeneous glycogen depletion and repletion kinetics that correlated with the severity of this depletion. Three types of regional glycogen kinetics were observed: (i) single exponential repletion (type a); (ii) biphasic recovery of rapid repletion followed by additional depletion (type b); (iii) biphasic recovery where continued depletion is followed by an exponential recovery (type c). The study of the complex patterns of glycogen kinetics suggests that glycogen breakdown may be quantitatively important during the initial recovery.
- 11 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1782-1792
Simultaneous monitoring of glycogen, creatine, and phosphocreatine in type II glycogen storage disease using saturation transfer MRI
Purpose: There is a need for non‐invasive approaches to assess the progression of glycogen storage diseases (GSD). Here, we use saturation transfer (ST) MRI via relayed nuclear Overhauser effects (glycoNOE) to detect abnormal changes in muscle glycogen of a GSD II mouse model. In addition to glycogen, the energy metabolites phosphocreatine (PCr) and creatine (Cr) were studied to assess the muscle disease. Methods: Water saturation (Z‐spectra) and 1 H MRS were acquired at 9.4 T on the skeletal muscle of healthy control mice and homozygous acid ‐glucosidase (GAA) knock‐out mice (ages of 2–48 weeks). The glycoNOE (−1 ppm), total creatine (tCr)* (+2 ppm, = a × [Cr] + b × [PCr]), and PCr (+2.5 ppm) from Z‐spectra and the ratio between tCr and taurine signals (tCr/Tau) from 1 H MRS spectra were quantified by using multi‐pool Lorentzian fitting methods. The concentrations of the metabolites were also measured via tissue assays. Results: The postnatal GSD II mice (age <12 weeks) showed a continued accumulation of muscle glycoNOE signal. GlycoNOE in adult GSD II mice (age ≥12 weeks) reached a plateau, at a level above 400% of that in normal mice. PCr, tCr*, and tCr/Tau gradually decreased in GSD II mice during the postnatal stage, then stabilized at levels comparable to adult control, yet PCr in adult GSD II mice was lower than that in controls. Conclusion: This study demonstrates that ST MRI of glycogen can provide in situ non‐invasive biomarkers for GSD II disease progression, with the potential to study the progression and treatment response of GSDs.
- 11 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1782-1792
Simultaneous monitoring of glycogen, creatine, and phosphocreatine in type II glycogen storage disease using saturation transfer MRI
Purpose: There is a need for non‐invasive approaches to assess the progression of glycogen storage diseases (GSD). Here, we use saturation transfer (ST) MRI via relayed nuclear Overhauser effects (glycoNOE) to detect abnormal changes in muscle glycogen of a GSD II mouse model. In addition to glycogen, the energy metabolites phosphocreatine (PCr) and creatine (Cr) were studied to assess the muscle disease. Methods: Water saturation (Z‐spectra) and 1 H MRS were acquired at 9.4 T on the skeletal muscle of healthy control mice and homozygous acid ‐glucosidase (GAA) knock‐out mice (ages of 2–48 weeks). The glycoNOE (−1 ppm), total creatine (tCr)* (+2 ppm, = a × [Cr] + b × [PCr]), and PCr (+2.5 ppm) from Z‐spectra and the ratio between tCr and taurine signals (tCr/Tau) from 1 H MRS spectra were quantified by using multi‐pool Lorentzian fitting methods. The concentrations of the metabolites were also measured via tissue assays. Results: The postnatal GSD II mice (age <12 weeks) showed a continued accumulation of muscle glycoNOE signal. GlycoNOE in adult GSD II mice (age ≥12 weeks) reached a plateau, at a level above 400% of that in normal mice. PCr, tCr*, and tCr/Tau gradually decreased in GSD II mice during the postnatal stage, then stabilized at levels comparable to adult control, yet PCr in adult GSD II mice was lower than that in controls. Conclusion: This study demonstrates that ST MRI of glycogen can provide in situ non‐invasive biomarkers for GSD II disease progression, with the potential to study the progression and treatment response of GSDs.
- 27 November 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 1115-1121
In vivo characterization of glycogen storage disease type III in a mouse model using glycoNOE MRI
Purpose: Glycogen storage disease type III (GSD III) is a rare inherited metabolic disease characterized by excessive accumulation of glycogen in liver, skeletal muscle, and heart. Currently, there are no widely available noninvasive methods to assess tissue glycogen levels and disease load. Here, we use glycogen nuclear Overhauser effect (glycoNOE) MRI to quantify hepatic glycogen levels in a mouse model of GSD III.Methods: Agl knockout mice (n = 13) and wild‐type controls (n = 10) were scanned for liver glycogen content using glycoNOE MRI. All mice were fasted for 12 to 16 h before MRI scans. GlycoNOE signal was quantified by fitting the Z‐spectrum using a four‐pool Voigt lineshape model. Next, the fitted direct water saturation pool was removed and glycoNOE signal was estimated from the integral of the residual Z spectrum within −0.6 to −1.4 ppm. Glycogen concentration was also measured ex vivo using a biochemical assay.Results: GlycoNOE MRI clearly distinguished Agl knockout mice from wild‐type controls, showing a statistically significant difference in glycoNOE signals in the livers across genotypes. There was a linear correlation between glycoNOE signal and glycogen concentration determined by the biochemical assay. The obtained glycoNOE maps of mouse livers also showed higher glycogen levels in Agl knockout mice compared to wild‐type mice.Conclusion: GlycoNOE MRI was used successfully as a noninvasive method to detect liver glycogen levels in mice, suggesting the potential of this method to be applied to assess glycogen storage diseases.
- 27 November 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 1115-1121
In vivo characterization of glycogen storage disease type III in a mouse model using glycoNOE MRI
Purpose: Glycogen storage disease type III (GSD III) is a rare inherited metabolic disease characterized by excessive accumulation of glycogen in liver, skeletal muscle, and heart. Currently, there are no widely available noninvasive methods to assess tissue glycogen levels and disease load. Here, we use glycogen nuclear Overhauser effect (glycoNOE) MRI to quantify hepatic glycogen levels in a mouse model of GSD III.Methods: Agl knockout mice (n = 13) and wild‐type controls (n = 10) were scanned for liver glycogen content using glycoNOE MRI. All mice were fasted for 12 to 16 h before MRI scans. GlycoNOE signal was quantified by fitting the Z‐spectrum using a four‐pool Voigt lineshape model. Next, the fitted direct water saturation pool was removed and glycoNOE signal was estimated from the integral of the residual Z spectrum within −0.6 to −1.4 ppm. Glycogen concentration was also measured ex vivo using a biochemical assay.Results: GlycoNOE MRI clearly distinguished Agl knockout mice from wild‐type controls, showing a statistically significant difference in glycoNOE signals in the livers across genotypes. There was a linear correlation between glycoNOE signal and glycogen concentration determined by the biochemical assay. The obtained glycoNOE maps of mouse livers also showed higher glycogen levels in Agl knockout mice compared to wild‐type mice.Conclusion: GlycoNOE MRI was used successfully as a noninvasive method to detect liver glycogen levels in mice, suggesting the potential of this method to be applied to assess glycogen storage diseases.
- 13 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (4) , 1429-1440
Ultrafast Z‐spectroscopic imaging in vivo at 3T using through‐slice spectral encoding (TS‐UFZ)
Purpose: Acquisition of high‐resolution Z‐spectra for CEST or magnetization transfer contrast (MTC) MRI requires excessive scan times. Ultrafast Z‐spectroscopy (UFZ) has been proposed to address this; however, the quality of in vivo UFZ spectra has been insufficient. Here, we present a simple approach to improve this.Theory and Methods: UFZ imaging acquires full Z‐spectra by encoding the spectral dimension spatially via a gradient applied concurrently with the RF saturation pulse. Different from previous implementations, both this saturation gradient and its readout were applied in the slice direction, resulting in a relatively uniform voxel composition. Phase‐encoding was applied in both in‐plane directions, allowing additional under‐sampling and acceleration.Results: In phantoms, UFZ imaging with through‐slice Z‐spectral encoding (TS‐UFZ) provided Z‐spectra of salicylic acid and egg white in excellent agreement with conventional acquisitions. In vivo brain Z‐spectra were influenced by flow through the imaging slice which affected the Z‐spectral baseline. Still, CEST signals could be quantified after baseline fitting and mapping the residual CEST signal. Amide proton transfer (APT) contrast intensities obtained by TS‐UFZ were on the same order of magnitude as conventional CEST but with different contrast across slice which likely is a result of different tissue regions contributing.Conclusion: TS‐UFZ approach improves signal stability and spectral uniformity over previous implementations and allows high spectral‐resolution imaging of saturation transfer effects in the human brain at 3T. This implementation allows for further acceleration by reducing phase encoding steps and thus opens up the possibility of mapping dynamic CEST signals in vivo with a practical temporal resolution.
- 13 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (4) , 1429-1440
Ultrafast Z‐spectroscopic imaging in vivo at 3T using through‐slice spectral encoding (TS‐UFZ)
Purpose: Acquisition of high‐resolution Z‐spectra for CEST or magnetization transfer contrast (MTC) MRI requires excessive scan times. Ultrafast Z‐spectroscopy (UFZ) has been proposed to address this; however, the quality of in vivo UFZ spectra has been insufficient. Here, we present a simple approach to improve this.Theory and Methods: UFZ imaging acquires full Z‐spectra by encoding the spectral dimension spatially via a gradient applied concurrently with the RF saturation pulse. Different from previous implementations, both this saturation gradient and its readout were applied in the slice direction, resulting in a relatively uniform voxel composition. Phase‐encoding was applied in both in‐plane directions, allowing additional under‐sampling and acceleration.Results: In phantoms, UFZ imaging with through‐slice Z‐spectral encoding (TS‐UFZ) provided Z‐spectra of salicylic acid and egg white in excellent agreement with conventional acquisitions. In vivo brain Z‐spectra were influenced by flow through the imaging slice which affected the Z‐spectral baseline. Still, CEST signals could be quantified after baseline fitting and mapping the residual CEST signal. Amide proton transfer (APT) contrast intensities obtained by TS‐UFZ were on the same order of magnitude as conventional CEST but with different contrast across slice which likely is a result of different tissue regions contributing.Conclusion: TS‐UFZ approach improves signal stability and spectral uniformity over previous implementations and allows high spectral‐resolution imaging of saturation transfer effects in the human brain at 3T. This implementation allows for further acceleration by reducing phase encoding steps and thus opens up the possibility of mapping dynamic CEST signals in vivo with a practical temporal resolution.
- Open Access
- 20 June 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (6) , e4778
The relayed nuclear Overhauser effect in magnetization transfer and chemical exchange saturation transfer MRI
Magnetic resonance (MR) is a powerful technique for noninvasively probing molecular species in vivo but suffers from low signal sensitivity. Saturation transfer (ST) MRI approaches, including chemical exchange saturation transfer (CEST) and conventional magnetization transfer contrast (MTC), allow imaging of low‐concentration molecular components with enhanced sensitivity using indirect detection via the abundant water proton pool. Several recent studies have shown the utility of chemical exchange relayed nuclear Overhauser effect (rNOE) contrast originating from nonexchangeable carbon‐bound protons in mobile macromolecules in solution. In this review, we describe the mechanisms leading to the occurrence of rNOE‐based signals in the water saturation spectrum (Z‐spectrum), including those from mobile and immobile molecular sources and from molecular binding. While it is becoming clear that MTC is mainly an rNOE‐based signal, we continue to use the classical MTC nomenclature to separate it from the rNOE signals of mobile macromolecules, which we will refer to as rNOEs. Some emerging applications of the use of rNOEs for probing macromolecular solution components such as proteins and carbohydrates in vivo or studying the binding of small substrates are discussed.
- 20 June 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (6) , e4778
Open AccessThe relayed nuclear Overhauser effect in magnetization transfer and chemical exchange saturation transfer MRI
Magnetic resonance (MR) is a powerful technique for noninvasively probing molecular species in vivo but suffers from low signal sensitivity. Saturation transfer (ST) MRI approaches, including chemical exchange saturation transfer (CEST) and conventional magnetization transfer contrast (MTC), allow imaging of low‐concentration molecular components with enhanced sensitivity using indirect detection via the abundant water proton pool. Several recent studies have shown the utility of chemical exchange relayed nuclear Overhauser effect (rNOE) contrast originating from nonexchangeable carbon‐bound protons in mobile macromolecules in solution. In this review, we describe the mechanisms leading to the occurrence of rNOE‐based signals in the water saturation spectrum (Z‐spectrum), including those from mobile and immobile molecular sources and from molecular binding. While it is becoming clear that MTC is mainly an rNOE‐based signal, we continue to use the classical MTC nomenclature to separate it from the rNOE signals of mobile macromolecules, which we will refer to as rNOEs. Some emerging applications of the use of rNOEs for probing macromolecular solution components such as proteins and carbohydrates in vivo or studying the binding of small substrates are discussed.
- Open Access
- 5 April 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 901-915
Detection of electrostatic molecular binding using the water proton signal
Purpose: Saturation transfer MRI has previously been used to probe molecular binding interactions with signal enhancement via the water signal. Here, we detail the relayed nuclear overhauser effect (rNOE) based mechanisms of this signal enhancement, develop a strategy of quantifying molecular binding affinity, i.e., the dissociation constant (), and apply the method to detect electrostatic binding of several charged small biomolecules. Another goal was to estimate the detection limit for transient receptor‐substrate binding.Theory and Methods: The signal enhancement mechanism was quantitatively described by a three‐step magnetization transfer model, and numerical simulations were performed to verify this theory. The binding equilibria of arginine, choline, and acetyl‐choline to anionic resin were studied as a function of ligand concentration, pH, and salt content. Equilibrium dissociation constants () were determined by fitting the multiple concentration data.Results: The numerical simulations indicate that the signal enhancement is sufficient to detect the molecular binding of sub‐millimolar (∼100 μM) concentration ligands to low micromolar levels of molecular targets. The measured rNOE signals from arginine, choline, and acetyl‐choline binding experiments show that several magnetization transfer pathways (intra‐ligand rNOEs and intermolecular rNOEs) can contribute. The rNOEs that arise from molecular ionic binding were influenced by pH and salt concentration. The molecular binding strengths in terms of ranged from 70–160 mM for the three cations studied.Conclusion: The capability to use MRI to detect the transient binding of small substrates paves a pathway towards the detection of micromolar level receptor‐substrate binding in vivo.
- 5 April 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 901-915
Open AccessDetection of electrostatic molecular binding using the water proton signal
Purpose: Saturation transfer MRI has previously been used to probe molecular binding interactions with signal enhancement via the water signal. Here, we detail the relayed nuclear overhauser effect (rNOE) based mechanisms of this signal enhancement, develop a strategy of quantifying molecular binding affinity, i.e., the dissociation constant (), and apply the method to detect electrostatic binding of several charged small biomolecules. Another goal was to estimate the detection limit for transient receptor‐substrate binding.Theory and Methods: The signal enhancement mechanism was quantitatively described by a three‐step magnetization transfer model, and numerical simulations were performed to verify this theory. The binding equilibria of arginine, choline, and acetyl‐choline to anionic resin were studied as a function of ligand concentration, pH, and salt content. Equilibrium dissociation constants () were determined by fitting the multiple concentration data.Results: The numerical simulations indicate that the signal enhancement is sufficient to detect the molecular binding of sub‐millimolar (∼100 μM) concentration ligands to low micromolar levels of molecular targets. The measured rNOE signals from arginine, choline, and acetyl‐choline binding experiments show that several magnetization transfer pathways (intra‐ligand rNOEs and intermolecular rNOEs) can contribute. The rNOEs that arise from molecular ionic binding were influenced by pH and salt concentration. The molecular binding strengths in terms of ranged from 70–160 mM for the three cations studied.Conclusion: The capability to use MRI to detect the transient binding of small substrates paves a pathway towards the detection of micromolar level receptor‐substrate binding in vivo.