CBChongxue Bie

Chongxue Bie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chongxue Bie has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • GRACE ‐ MORE : A Motion‐Resolved Golden‐Angle Radial CEST MRI Technique for Free‐Breathing Abdominal Imaging

    by Yitian Fan, Chongxue Bie, Xinding Jiang, Zhekai Chen, Meijuan Li, Yang Zhou, Lin Chen

    Purpose: To develop a motion‐resolved acquisition and reconstruction framework for motion‐robust and spectrally reliable abdominal CEST imaging under free‐breathing conditions. Theory and Methods: A framework termed Golden‐angle RAdial CEST MRI with MOtion‐REsolved reconstruction (GRACE‐MORE) was developed to improve acquisition, respiratory‐phase binning, and reconstruction. An interleaved steady‐state saturation module with golden‐angle radial sampling was adopted to enhance saturation efficiency and ensure uniform k‐space coverage. Respiratory‐phase binning was performed using a self‐gated strategy, in which respiratory amplitude and phase were extracted from central k‐space via principal component analysis, followed by hybrid empirical mode decomposition‐continuous wavelet transform sorting to correct baseline drift and irregular breathing. Reconstruction was performed using a deep unrolled network constrained by low‐rank and sparsity priors, which incorporated a modified U‐Net with channel attention and a sliding‐window grouping scheme to capture spatio‐spectral correlations across saturation offsets. Results: Validation on simulated, preclinical, and clinical datasets demonstrated more than a threefold improvement in binning accuracy compared with conventional methods. GRACE‐MORE reduced reconstruction error, yielded a higher structural similarity index and peak signal‐to‐noise ratio in simulations, and achieved improved anatomical fidelity, effective motion suppression, and up to a fourfold increase in Z‐spectral signal‐to‐noise ratio in vivo. Conclusion: GRACE‐MORE enables motion‐robust and spectrally reliable abdominal CEST imaging under free‐breathing conditions.


  • Noninvasive Mapping of Creatine Kinase Metabolism in Human Muscle Using pH‐Insensitive PCrCEST MRI at 3 and 5 T

    by Xinran Chen, Xi Xu, Chongxue Bie, Peter van Zijl, Nirbhay Yadav, Jiadi Xu, Qizhi Yang, Tao Wang, Zhong Chen, Lin Chen, et al.

    Phosphocreatine (PCr) recovery after exercise reflects creatine kinase (CK) metabolism and is a key marker of muscle energetics. However, current chemical exchange saturation transfer (CEST)–based PCr imaging (PCrCEST) remains limited by pH‐dependent contrast. Here, we present a pH‐insensitive PCrCEST strategy that minimizes pH‐related signal variability, enabling more reliable in vivo quantification during exercise, when tissue pH may change. Theoretical derivation, simulations, and phantom studies confirmed that PCrCEST signals varied by less than 20% across the physiological pH range when the saturation radial frequency (γ B 1 ) matches the guanidinium proton exchange rate. Under this optimized B 1 condition, kinetic simulations further show that the PCrCEST‐derived recovery time constant ( τ PCr ) closely follows expected behavior even during dynamic pH changes. The pH‐insensitive strategy was implemented at both 3 and 5 T and assessed in human calf muscle during plantar flexion exercise. These results demonstrate that pH‐insensitive PCrCEST enabled robust mapping of muscle CK metabolism. The availability of pH‐insensitive CEST mapping improves the potential of CEST not only for exercise measurements but also for broader clinical translation.


  • Rapid 3D Saturation Transfer Imaging for Simultaneous Phosphocreatine and Glycogen Mapping in Human Muscle

    by Xi Xu, Xinran Chen, Yuanyuan Liu, Chongxue Bie, Hao Wu, Siqi Cai, Sen Jia, Lin Chen, Dong Liang, Hairong Zheng, et al.

    Objective: Phosphocreatine (PCr) and glycogen are key metabolites underpinning the skeletal muscle contractions. Simultaneous 3D imaging of these metabolites is valuable for understanding heterogeneous energetic events. While saturation transfer (ST) MRI can detect metabolites, 3D ST acquisition generally requires long scan times. We developed a rapid, high-resolution 3D scanning scheme for simultaneous quantification of PCr and glycogen. Methods: A 3D sequence was implemented on a 5 T MR scanner, using a continuous-wave saturation pulse and golden-angle stack-of-stars readouts. A patch-based low-rank algorithm was incorporated to reduce scan time. The sensitivity of sequence to concentration variations was validated in phantom experiments, and metabolite distribution was assessed in vivo. Furthermore, exercise protocols were employed to investigate metabolic heterogeneity. Results: The optimized acquisition strategy reduced the scan time to 26.7% of full sampling. Phantom studies showed a linear correlation between contrast signals and metabolite concentrations, in-vivo studies demonstrated uniform PCr and glycogen distribution across slices. Post-exercise, PCr and glycogen depletion was clearly observed. Conclusion and Significance: The 3D rapid ST imaging framework achieves 100 mm coverage of skeletal muscle in 11.2 minutes, showing the potential to monitor muscle physiological processes.


  • Open Access

    Brain temperature mapping based on chemical exchange saturation transfer signal at 2 ppm

    by Siqi Cai, Chongxue Bie, Yang Zhou, Chao Zou, Xi Xu, Ganghan Yang, Chunxiang Jiang, Lijuan Zhang

    Background: Brain temperature signifies the thermal homeostasis of the tissue, and may serve as a marker for neuroprotective therapy. Currently, it remains challenging to map the human brain temperature with high spatial resolution. The thermal dependence of chemical exchange saturation transfer (CEST) effects of endogenous labile protons may provide a promising mechanism for the absolute brain temperature imaging. In this study, we aimed to investigate the temperature dependency of the CEST effect of creatine (CrCEST), and contemplate its feasibility for brain temperature mapping. Methods: Creatine (Cr) was selected as the endogenous agent to probe the brain temperature. Proof-of-concept phantom experiments were first conducted using a 400 MHz nuclear magnetic resonance (NMR) spectrometer and a 5.0 T magnetic resonance (MR) scanner at various temperatures. A multi-pool Lorentzian fitting model was utilized to quantify the apparent chemical shift, amplitude, linewidth, and integral of CrCEST peak at around 2 ppm. Regression analysis was performed to estimate the thermal response of these CrCEST parameters. Finally, the temperature mapping of ex vivo swine brain tissues was conducted based on the CEST signal at 2 ppm (CEST@2ppm). Results: A robust linear correlation between the apparent chemical shift of CrCEST and temperature was identified in the in vitro phantom experiments (+0.005 ppm/℃, Pex vivo swine brain tissue, a comparable temperature dependency of the apparent chemical shift of CEST@2ppm peak was found (+0.008 ppm/℃), confirming the utility of this approach for mapping brain temperature. Conclusions: The CEST-based approach proposed in this study suggests a path toward label-free brain thermometry in vivo at high resolution and may be potentially applied in other tissues such as muscle and kidney.


  • Open Access

    In vivo imaging of glycogen in human muscle

    by Chongxue Bie, Yuxuan Ma, Peter C. M. van Zijl, Nirbhay N. Yadav, Xi Xu, Hairong Zheng, Dong Liang, Chao Zou, José L. Areta, Lin Chen, et al.

    Probing regional glycogen metabolism in humans non-invasively has been challenging due to a lack of sensitive approaches. Here we studied human muscle glycogen dynamics post-exercise with a spatial resolution of millimeters and temporal resolution of minutes, using relayed nuclear Overhauser effect (glycoNOE) MRI. Data at 5T showed a homogeneous distribution of glycogen in resting muscle, with an average concentration of 99 ± 13 mM. After plantar flexion exercise following fasting with recovery under fasting conditions, the calf muscle showed spatially heterogeneous glycogen depletion and repletion kinetics that correlated with the severity of this depletion. Three types of regional glycogen kinetics were observed: (i) single exponential repletion (type a); (ii) biphasic recovery of rapid repletion followed by additional depletion (type b); (iii) biphasic recovery where continued depletion is followed by an exponential recovery (type c). The study of the complex patterns of glycogen kinetics suggests that glycogen breakdown may be quantitatively important during the initial recovery.


  • Simultaneous monitoring of glycogen, creatine, and phosphocreatine in type II glycogen storage disease using saturation transfer MRI

    by Chongxue Bie, Shaowei Bo, Nirbhay N. Yadav, Peter C. M. van Zijl, Tao Wang, Lin Chen, Jiadi Xu, Chao Zou, Hairong Zheng, Yang Zhou

    Purpose: There is a need for non‐invasive approaches to assess the progression of glycogen storage diseases (GSD). Here, we use saturation transfer (ST) MRI via relayed nuclear Overhauser effects (glycoNOE) to detect abnormal changes in muscle glycogen of a GSD II mouse model. In addition to glycogen, the energy metabolites phosphocreatine (PCr) and creatine (Cr) were studied to assess the muscle disease. Methods: Water saturation (Z‐spectra) and 1 H MRS were acquired at 9.4 T on the skeletal muscle of healthy control mice and homozygous acid ‐glucosidase (GAA) knock‐out mice (ages of 2–48 weeks). The glycoNOE (−1 ppm), total creatine (tCr)* (+2 ppm, = a × [Cr] + b × [PCr]), and PCr (+2.5 ppm) from Z‐spectra and the ratio between tCr and taurine signals (tCr/Tau) from 1 H MRS spectra were quantified by using multi‐pool Lorentzian fitting methods. The concentrations of the metabolites were also measured via tissue assays. Results: The postnatal GSD II mice (age <12 weeks) showed a continued accumulation of muscle glycoNOE signal. GlycoNOE in adult GSD II mice (age ≥12 weeks) reached a plateau, at a level above 400% of that in normal mice. PCr, tCr*, and tCr/Tau gradually decreased in GSD II mice during the postnatal stage, then stabilized at levels comparable to adult control, yet PCr in adult GSD II mice was lower than that in controls. Conclusion: This study demonstrates that ST MRI of glycogen can provide in situ non‐invasive biomarkers for GSD II disease progression, with the potential to study the progression and treatment response of GSDs.


  • In vivo characterization of glycogen storage disease type III in a mouse model using glycoNOE MRI

    by Qing Zeng, Michael Machado, Chongxue Bie, Peter C. M. van Zijl, Sofi Malvar, Yuguo Li, Valentina D'SOuza, Kirsten Achilles Poon, Andrew Grimm, Nirbhay N. Yadav

    Purpose: Glycogen storage disease type III (GSD III) is a rare inherited metabolic disease characterized by excessive accumulation of glycogen in liver, skeletal muscle, and heart. Currently, there are no widely available noninvasive methods to assess tissue glycogen levels and disease load. Here, we use glycogen nuclear Overhauser effect (glycoNOE) MRI to quantify hepatic glycogen levels in a mouse model of GSD III.Methods: Agl knockout mice (n = 13) and wild‐type controls (n = 10) were scanned for liver glycogen content using glycoNOE MRI. All mice were fasted for 12 to 16 h before MRI scans. GlycoNOE signal was quantified by fitting the Z‐spectrum using a four‐pool Voigt lineshape model. Next, the fitted direct water saturation pool was removed and glycoNOE signal was estimated from the integral of the residual Z spectrum within −0.6 to −1.4 ppm. Glycogen concentration was also measured ex vivo using a biochemical assay.Results: GlycoNOE MRI clearly distinguished Agl knockout mice from wild‐type controls, showing a statistically significant difference in glycoNOE signals in the livers across genotypes. There was a linear correlation between glycoNOE signal and glycogen concentration determined by the biochemical assay. The obtained glycoNOE maps of mouse livers also showed higher glycogen levels in Agl knockout mice compared to wild‐type mice.Conclusion: GlycoNOE MRI was used successfully as a noninvasive method to detect liver glycogen levels in mice, suggesting the potential of this method to be applied to assess glycogen storage diseases.


  • Ultrafast Z‐spectroscopic imaging in vivo at 3T using through‐slice spectral encoding (TS‐UFZ)

    by Chongxue Bie, Peter C. M. van Zijl, Deng Mao, Nirbhay N. Yadav

    Purpose: Acquisition of high‐resolution Z‐spectra for CEST or magnetization transfer contrast (MTC) MRI requires excessive scan times. Ultrafast Z‐spectroscopy (UFZ) has been proposed to address this; however, the quality of in vivo UFZ spectra has been insufficient. Here, we present a simple approach to improve this.Theory and Methods: UFZ imaging acquires full Z‐spectra by encoding the spectral dimension spatially via a gradient applied concurrently with the RF saturation pulse. Different from previous implementations, both this saturation gradient and its readout were applied in the slice direction, resulting in a relatively uniform voxel composition. Phase‐encoding was applied in both in‐plane directions, allowing additional under‐sampling and acceleration.Results: In phantoms, UFZ imaging with through‐slice Z‐spectral encoding (TS‐UFZ) provided Z‐spectra of salicylic acid and egg white in excellent agreement with conventional acquisitions. In vivo brain Z‐spectra were influenced by flow through the imaging slice which affected the Z‐spectral baseline. Still, CEST signals could be quantified after baseline fitting and mapping the residual CEST signal. Amide proton transfer (APT) contrast intensities obtained by TS‐UFZ were on the same order of magnitude as conventional CEST but with different contrast across slice which likely is a result of different tissue regions contributing.Conclusion: TS‐UFZ approach improves signal stability and spectral uniformity over previous implementations and allows high spectral‐resolution imaging of saturation transfer effects in the human brain at 3T. This implementation allows for further acceleration by reducing phase encoding steps and thus opens up the possibility of mapping dynamic CEST signals in vivo with a practical temporal resolution.


  • Open Access

    The relayed nuclear Overhauser effect in magnetization transfer and chemical exchange saturation transfer MRI

    by Yang Zhou, Chongxue Bie, Peter C. M. van Zijl, Nirbhay N. Yadav

    Magnetic resonance (MR) is a powerful technique for noninvasively probing molecular species in vivo but suffers from low signal sensitivity. Saturation transfer (ST) MRI approaches, including chemical exchange saturation transfer (CEST) and conventional magnetization transfer contrast (MTC), allow imaging of low‐concentration molecular components with enhanced sensitivity using indirect detection via the abundant water proton pool. Several recent studies have shown the utility of chemical exchange relayed nuclear Overhauser effect (rNOE) contrast originating from nonexchangeable carbon‐bound protons in mobile macromolecules in solution. In this review, we describe the mechanisms leading to the occurrence of rNOE‐based signals in the water saturation spectrum (Z‐spectrum), including those from mobile and immobile molecular sources and from molecular binding. While it is becoming clear that MTC is mainly an rNOE‐based signal, we continue to use the classical MTC nomenclature to separate it from the rNOE signals of mobile macromolecules, which we will refer to as rNOEs. Some emerging applications of the use of rNOEs for probing macromolecular solution components such as proteins and carbohydrates in vivo or studying the binding of small substrates are discussed.


  • Open Access

    Detection of electrostatic molecular binding using the water proton signal

    by Yang Zhou, Chongxue Bie, Peter C. M. van Zijl, Jiadi Xu, Chao Zou, Nirbhay N. Yadav

    Purpose: Saturation transfer MRI has previously been used to probe molecular binding interactions with signal enhancement via the water signal. Here, we detail the relayed nuclear overhauser effect (rNOE) based mechanisms of this signal enhancement, develop a strategy of quantifying molecular binding affinity, i.e., the dissociation constant (), and apply the method to detect electrostatic binding of several charged small biomolecules. Another goal was to estimate the detection limit for transient receptor‐substrate binding.Theory and Methods: The signal enhancement mechanism was quantitatively described by a three‐step magnetization transfer model, and numerical simulations were performed to verify this theory. The binding equilibria of arginine, choline, and acetyl‐choline to anionic resin were studied as a function of ligand concentration, pH, and salt content. Equilibrium dissociation constants () were determined by fitting the multiple concentration data.Results: The numerical simulations indicate that the signal enhancement is sufficient to detect the molecular binding of sub‐millimolar (∼100 μM) concentration ligands to low micromolar levels of molecular targets. The measured rNOE signals from arginine, choline, and acetyl‐choline binding experiments show that several magnetization transfer pathways (intra‐ligand rNOEs and intermolecular rNOEs) can contribute. The rNOEs that arise from molecular ionic binding were influenced by pH and salt concentration. The molecular binding strengths in terms of ranged from 70–160 mM for the three cations studied.Conclusion: The capability to use MRI to detect the transient binding of small substrates paves a pathway towards the detection of micromolar level receptor‐substrate binding in vivo.