PBPascal Bebié
Pascal Bebié
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pascal Bebié has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Afroditi Eleftheriou
Institute of Pharmacology and Toxicology, University of Zurich, 8057 Zurich, Switzerland
1 shared publication - Agnieszka Zagozdzinska-Bochenek
Institute for Particle Physics and Astrophysics, ETH Zurich, 8093 Zurich, Switzerland
1 shared publication Bruno Weber
Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
1 shared publication- Bruno Weber
Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
1 shared publication - Charalampos Tsoumpas
University Medical Center Groningen, University of Groningen
1 shared publication Christian Ritzer
Institute for Particle Physics and Astrophysics, ETH Zurich, Zurich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 12 December 2023
- Published by Springer Nature in EJNMMI Physics
- Vol. 10 (1) , 1-20
SAFIR-I: first NEMA NU 4-2008-based performance characterization
Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a novel Positron Emission Tomography insert for a $$7\,\hbox {T}$$ Bruker BioSpec 70/30 Ultra Shield Refrigerated Magnetic Resonance Imaging (MRI) system. It facilitates truly simultaneous quantitative imaging in mice and rats at injected activities as high as $$500\,\hbox {MBq}$$ . Exploitation of the resulting high count rates enables quick image formation at few seconds per frame. In this investigation, key performance parameters of SAFIR-I have been determined according to the evaluations outlined in the National Electrical Manufacturers Association (NEMA) Standards Publication NU 4-2008 (NEMA-NU4) protocol.Results: Using an energy window of 391 to $$601\,\hbox {keV}$$ and a Coincidence Timing Window of $$500\,\hbox {ps}$$ , the following performance was observed: The average spatial resolution at $$5\,\hbox {mm}$$ radial offset (Full Width at Half Maximum) is $$2.54\,\hbox {mm}$$ when using Filtered Backprojection, 3D Reprojection reconstruction. For the mouse- and rat-like phantoms, the maximal Noise-Equivalent Count Rates (NECRs) are $$1368\,\hbox {kcps}$$ at the highest tested average effective concentration of $$14.7\,\hbox {MBq}\,\hbox {cc}^{-1}$$ , and $$713\,\hbox {kcps}$$ at the highest tested average effective concentration of $$1.72\,\hbox {MBq}\,\hbox {cc}^{-1}$$ , respectively. The NECR peak is not yet reached for either of these cases. The peak sensitivity is $$1.46\,\%$$ . The Image Quality phantom uniformity standard deviation is $$4.8\,\%$$ . The Recovery Coefficient for the $$5\,\hbox {mm}$$ rod is $$(1.08 \pm 0.10)$$ . The Spill-Over Ratios are $$(0.22 \pm 0.03)$$ and $$(0.22 \pm 0.02)$$ , for the water- and air-filled cylinder, respectively. An accuracy of $$4.3\,\%$$ was achieved for the quantitative calibration of reconstructed voxel values.Conclusions: The measured performance parameters indicate that the various design goals have been achieved. SAFIR-I offers excellent performance, especially at the high activities it was designed for. This facilitates planned experiments with fast tracer kinetics in small animals. Ways to potentially improve performance can still be explored. Simultaneously, further performance gains can be expected for a forthcoming insert featuring 2.7 times longer axial coverage named Small Animal Fast Insert for MRI detector II (SAFIR-II).- 12 December 2023
- Published by Springer Nature in EJNMMI Physics
- Vol. 10 (1) , 1-20
Open AccessSAFIR-I: first NEMA NU 4-2008-based performance characterization
Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a novel Positron Emission Tomography insert for a $$7\,\hbox {T}$$ Bruker BioSpec 70/30 Ultra Shield Refrigerated Magnetic Resonance Imaging (MRI) system. It facilitates truly simultaneous quantitative imaging in mice and rats at injected activities as high as $$500\,\hbox {MBq}$$ . Exploitation of the resulting high count rates enables quick image formation at few seconds per frame. In this investigation, key performance parameters of SAFIR-I have been determined according to the evaluations outlined in the National Electrical Manufacturers Association (NEMA) Standards Publication NU 4-2008 (NEMA-NU4) protocol.Results: Using an energy window of 391 to $$601\,\hbox {keV}$$ and a Coincidence Timing Window of $$500\,\hbox {ps}$$ , the following performance was observed: The average spatial resolution at $$5\,\hbox {mm}$$ radial offset (Full Width at Half Maximum) is $$2.54\,\hbox {mm}$$ when using Filtered Backprojection, 3D Reprojection reconstruction. For the mouse- and rat-like phantoms, the maximal Noise-Equivalent Count Rates (NECRs) are $$1368\,\hbox {kcps}$$ at the highest tested average effective concentration of $$14.7\,\hbox {MBq}\,\hbox {cc}^{-1}$$ , and $$713\,\hbox {kcps}$$ at the highest tested average effective concentration of $$1.72\,\hbox {MBq}\,\hbox {cc}^{-1}$$ , respectively. The NECR peak is not yet reached for either of these cases. The peak sensitivity is $$1.46\,\%$$ . The Image Quality phantom uniformity standard deviation is $$4.8\,\%$$ . The Recovery Coefficient for the $$5\,\hbox {mm}$$ rod is $$(1.08 \pm 0.10)$$ . The Spill-Over Ratios are $$(0.22 \pm 0.03)$$ and $$(0.22 \pm 0.02)$$ , for the water- and air-filled cylinder, respectively. An accuracy of $$4.3\,\%$$ was achieved for the quantitative calibration of reconstructed voxel values.Conclusions: The measured performance parameters indicate that the various design goals have been achieved. SAFIR-I offers excellent performance, especially at the high activities it was designed for. This facilitates planned experiments with fast tracer kinetics in small animals. Ways to potentially improve performance can still be explored. Simultaneously, further performance gains can be expected for a forthcoming insert featuring 2.7 times longer axial coverage named Small Animal Fast Insert for MRI detector II (SAFIR-II). - Open Access
SAFIR-I: Design and Performance of a High-Rate Preclinical PET Insert for MRI
(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7 Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of and an inner diameter of 114. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system’s Coincidence Resolving Time (CRT) and energy resolution are between separate-uncertainty and separate-uncertainty Full Width at Half Maximum (FWHM) at low activity and separate-uncertainty and separate-uncertainty FWHM at 550, respectively. The peak sensitivity is ∼. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300. Based on features visible in the acquired images, we estimate the spatial resolution to be ∼2 in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500.Open AccessSAFIR-I: Design and Performance of a High-Rate Preclinical PET Insert for MRI
(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7 Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of and an inner diameter of 114. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system’s Coincidence Resolving Time (CRT) and energy resolution are between separate-uncertainty and separate-uncertainty Full Width at Half Maximum (FWHM) at low activity and separate-uncertainty and separate-uncertainty FWHM at 550, respectively. The peak sensitivity is ∼. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300. Based on features visible in the acquired images, we estimate the spatial resolution to be ∼2 in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500.