David Rode
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
David Rode has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Connor Lane
Institute of Fluid Dynamics, ETH Zürich, Zürich, Switzerland
3 shared publications Thomas Rösgen
Institute of Fluid Dynamics
2 shared publications- Eva Schulz
Kardinal Schwarzenberg Clinic, Schwarzach im Pongau, Austria
1 shared publication Laurent Audigé
Affiliations Research and Development, Schulthess Klinik, Zurich, Switzerland, Surgical Outcome Research Center, University Hospital of Basel, Basel, Switzerland
1 shared publicationMario Bizzini
Affiliation Human Performance Lab, Schulthess Klinik, Zurich, Switzerland
1 shared publicationNicola A. Maffiuletti
Affiliation Human Performance Lab, Schulthess Klinik, Zurich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 23 July 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (7) , e0353801
Validation of markerless human pose estimation methods for clinical assessment of elbow range of motion
Clinicians rely on the assessment of joint range of motion to determine the necessity of clinical interventions and to track rehabilitation progress. They often perform visual assessments of these joint angles due to limited time for longer but more accurate methods. Markerless monocular human pose estimation methods could help reduce the workload of physicians in clinical practice, allow patients to conduct regular assessments remotely, and be used to provide reliable assessments in the absence of expert raters, but they have not been validated extensively on clinical populations. We measured the elbow flexion and extension ranges of motion of 46 patients with shoulder and elbow pathologies. These values were assessed by RTMW and HSMR, two different monocular pose estimation methods, and an experienced physician who performed visual assessments. A state-of-the-art passive-marker optical motion capture system was used as the reference system. For elbow flexion, HSMR outperformed visual assessment. HSMR had a higher concordance correlation coefficient of 0.92 and a lower minimal detectable change of 6.74° as determined by a concordance analysis and a linear mixed-effects model. Conversely, for elbow extension, visual assessment outperformed both markerless methods. RTMW was the best-performing markerless method with a concordance correlation coefficient of 0.83 and a minimal detectable change of 7.93°. Thus, HSMR represented a viable alternative to visual assessment for measuring elbow flexion range of motion in a clinical population, but neither RTMW nor HSMR offered an improvement over visual assessment for measuring elbow extension range of motion.
- 23 July 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (7) , e0353801
Open AccessValidation of markerless human pose estimation methods for clinical assessment of elbow range of motion
Clinicians rely on the assessment of joint range of motion to determine the necessity of clinical interventions and to track rehabilitation progress. They often perform visual assessments of these joint angles due to limited time for longer but more accurate methods. Markerless monocular human pose estimation methods could help reduce the workload of physicians in clinical practice, allow patients to conduct regular assessments remotely, and be used to provide reliable assessments in the absence of expert raters, but they have not been validated extensively on clinical populations. We measured the elbow flexion and extension ranges of motion of 46 patients with shoulder and elbow pathologies. These values were assessed by RTMW and HSMR, two different monocular pose estimation methods, and an experienced physician who performed visual assessments. A state-of-the-art passive-marker optical motion capture system was used as the reference system. For elbow flexion, HSMR outperformed visual assessment. HSMR had a higher concordance correlation coefficient of 0.92 and a lower minimal detectable change of 6.74° as determined by a concordance analysis and a linear mixed-effects model. Conversely, for elbow extension, visual assessment outperformed both markerless methods. RTMW was the best-performing markerless method with a concordance correlation coefficient of 0.83 and a minimal detectable change of 7.93°. Thus, HSMR represented a viable alternative to visual assessment for measuring elbow flexion range of motion in a clinical population, but neither RTMW nor HSMR offered an improvement over visual assessment for measuring elbow extension range of motion.
- Open Access
- 1 November 2021
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 146, 106724
Optical characterization method for birefringent fluids using a polarization camera
- 1 November 2021
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 146, 106724
Open AccessOptical characterization method for birefringent fluids using a polarization camera
- 25 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (6) , C37-C45
Calibration of a polarization image sensor and investigation of influencing factors
Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600 × 400 p i x e l s were analyzed, and it is shown that sufficiently large f -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.
- 25 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (6) , C37-C45
Calibration of a polarization image sensor and investigation of influencing factors
Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600 × 400 p i x e l s were analyzed, and it is shown that sufficiently large f -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.
- 16 September 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (27) , 8435-8444
Two-dimensional birefringence measurement technique using a polarization camera
A two-dimensional birefringence measurement method is described. In this procedure, we send light through a rotatable linear polarizer and subsequently through a transparent and birefringent specimen. A polarization camera measures the state of linear polarization from which the relative position of the refractive index axes and the relative phase difference is determined. The measurement range of the phase difference is up torad, which corresponds to an optical retardation of half the wavelength of the light. The imaging system can measure a large sample area within one measurement cycle. Measurement performance is demonstrated with a quarter-wave plate, and an exemplary test case is shown.- 16 September 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (27) , 8435-8444
Two-dimensional birefringence measurement technique using a polarization camera
A two-dimensional birefringence measurement method is described. In this procedure, we send light through a rotatable linear polarizer and subsequently through a transparent and birefringent specimen. A polarization camera measures the state of linear polarization from which the relative position of the refractive index axes and the relative phase difference is determined. The measurement range of the phase difference is up torad, which corresponds to an optical retardation of half the wavelength of the light. The imaging system can measure a large sample area within one measurement cycle. Measurement performance is demonstrated with a quarter-wave plate, and an exemplary test case is shown.