DRDavid Rode

David Rode

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David Rode has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of markerless human pose estimation methods for clinical assessment of elbow range of motion

    by David Rode, Romina Willi, Eva Schulz, Tim Schneller, Philipp Moroder, Laurent Audigé, Mario Bizzini, Nicola A. Maffiuletti, Peter Wolf, Robert Riener

    Clinicians rely on the assessment of joint range of motion to determine the necessity of clinical interventions and to track rehabilitation progress. They often perform visual assessments of these joint angles due to limited time for longer but more accurate methods. Markerless monocular human pose estimation methods could help reduce the workload of physicians in clinical practice, allow patients to conduct regular assessments remotely, and be used to provide reliable assessments in the absence of expert raters, but they have not been validated extensively on clinical populations. We measured the elbow flexion and extension ranges of motion of 46 patients with shoulder and elbow pathologies. These values were assessed by RTMW and HSMR, two different monocular pose estimation methods, and an experienced physician who performed visual assessments. A state-of-the-art passive-marker optical motion capture system was used as the reference system. For elbow flexion, HSMR outperformed visual assessment. HSMR had a higher concordance correlation coefficient of 0.92 and a lower minimal detectable change of 6.74° as determined by a concordance analysis and a linear mixed-effects model. Conversely, for elbow extension, visual assessment outperformed both markerless methods. RTMW was the best-performing markerless method with a concordance correlation coefficient of 0.83 and a minimal detectable change of 7.93°. Thus, HSMR represented a viable alternative to visual assessment for measuring elbow flexion range of motion in a clinical population, but neither RTMW nor HSMR offered an improvement over visual assessment for measuring elbow extension range of motion.


  • Calibration of a polarization image sensor and investigation of influencing factors

    by Connor Lane, David Rode, Thomas Rösgen

    Polarization measurements conducted with a polarization camera using the Sony IMX 250 MZR polarization image sensor are assessed with the super-pixel calibration technique and a simple test setup. We define an error that quantifies the quality of the polarization measurements. Multiple factors influencing the measurement quality of the polarization camera are investigated and discussed. We demonstrate that polarization measurements are generally consistent throughout the sensor if not corrupted by large chief ray angles or large angles of incidence. The central 600 × 400 p i x e l s were analyzed, and it is shown that sufficiently large f -numbers no longer influence measurement quality. We also argue that lens design and focal length have little influence on these central pixels. The findings of this study provide useful guidance for researchers using such a polarization image sensor.


  • Two-dimensional birefringence measurement technique using a polarization camera

    by Connor Lane, David Rode, Thomas Rösgen

    A two-dimensional birefringence measurement method is described. In this procedure, we send light through a rotatable linear polarizer and subsequently through a transparent and birefringent specimen. A polarization camera measures the state of linear polarization from which the relative position of the refractive index axes and the relative phase difference is determined. The measurement range of the phase difference is up toπrad, which corresponds to an optical retardation of half the wavelength of the light. The imaging system can measure a large sample area within one measurement cycle. Measurement performance is demonstrated with a quarter-wave plate, and an exemplary test case is shown.