PSPeng Shi

Peng Shi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peng Shi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Robotic Platform for Endovascular Surgery: Human–Robot Interaction Studies

    by Xiaoliang Jin, Shuxiang Guo, Aiguo Song, Peng Shi, Xinming Li, Masahiko Kawanishi

    Robot-assisted vascular interventional surgery (RVIS) is an emerging technology for the treatment of vascular diseases. It has obvious advantages over traditional manual operation, such as increased accuracy, reduced fatigue, and reduced tremor. However, current research suggests that natural human–robot interaction in RVIS is still a challenge that needs to be addressed. In this article, we developed a novel robotic platform that realized magnetorheological (MR) fluids-based haptic feedback to improve the interventionist’s tactile presence. In addition, we proposed a force sensing method to accurately detect the real-time force of the flexible instrument and a collaborative operation method of the guidewire and the catheter to assist the flexible instruments in selecting the target blood vessel branch and reduce the operation difficulty of the interventionist. To verify the developed robotic platform and the proposed methods, we conducted the performance evaluation experiments in a blood vessel model and an endo vascular evaluator. The results indicated that the developed robotic platform and the proposed methods have great potential to improve the natural human–robot interaction in RVIS and guarantee safety.


  • Soft Magnetic-Actuation-Based Haptic Interface for a Robot-Assisted Vascular Interventional System: A Feasibility Study

    by Xinming Li, Shuxiang Guo, Keisuke Suzuki, Peng Shi, Xiaoliang Jin

    As a promising alternative for minimally invasive vascular surgery, robot-assisted vascular interventional system (VIS) has expressed considerable benefits in preventing radiation, decreasing workload for surgeons, improving surgical environment, reducing post-operative risk for patients. However, existing robotic VISs ignore to employing proper haptic feedback for robot-assisted surgery owing to the short of flexible and controllable capabilities of haptic perception. In this work, we develop a dual-instrument operating robotic VIS to manipulate guidewire and catheter, which is capable for multi-instrument surgical tasks. Most importantly, a soft magnetic-actuation-based haptic interface, a prospective solution for haptic sensing based on flexible combination of soft material and magnetic material, is proposed to provide adjustable haptic information for operators. Moreover, a safety operation strategy based on proposed haptic interface is designed to ensure a safer operating environment for interaction between master side and slave side. Four kinds of experiments are performed to demonstrate the feasibility of soft magnetic-actuation-based haptic feedback, evaluate the tracking performance and operating performance of developed robot-assisted VIS. Results prove the engineering feasibility (haptic sensing range: 0.01 N-1.49 N) of the proposed haptic interface and the operating effectiveness of developed robot-assisted VIS (maximum linear error is 1.87 mm). Besides, this effort probably has a potential impact on implementation of soft haptic feedback, research of multi-instrument device, and improvement of safety operation for robotic systems.


  • A Bimodal Detection-Based Tremor Suppression System for Vascular Interventional Surgery Robots

    by Xinming Li, Shuxiang Guo, Peng Shi, Xiaoliang Jin, Masahiko Kawanishi, Keisuke Suzuki

    Vascular interventional surgery (VIS) robots generally rely on faster and more accurate signal interaction system between the master side and slave side. During actual operations, unconscious and nonlinear tremors limit the accuracy and safety for VIS robot’s operation. To solve above issues, this article proposes a novel bimodal detection-based tremor suppression system to improve the accuracy of data interaction. More precisely, a bimodal tremor detection combined self-designed force sensitive resistor (FSR) and a linear encoder sensor is employed for radial and axial tremor detection, respectively. Tremor suppression method based on active restraint and passive modification is presented in this study, which can not only reduce the regular tremor but also effectively suppress the suddenly burst tremor. Experiments and performance analysis of the proposed method are evaluated from simulations and actual experimental results. Based on these evaluations, the tremor suppression method has obvious advantages for suppressing non-linear tremors and enhancing the timeliness of signal interaction, which the average computing time for tremor is 140 ms and average maximum amplitude moves to 2.47 mm. Moreover, we also discuss the issues for time delay and the transmission loss existed in actual experiments. Besides, this article has a potential impact on eliminating non-linear errors, improving the safety performance of operations for master–slave robotic system, and solving the crossing problem for time–frequency domain.


  • Active Suppression Method of Dangerous Behaviors for Robot-Assisted Vascular Interventional Surgery

    by Xiaoliang Jin, Shuxiang Guo, Jian Guo, Peng Shi, Masahiko Kawanishi, Hideyuki Hirata

    The procedure of vascular interventional surgery (VIS) is very complicated. It requires doctors to wear the protecting suits and manipulate the flexible instruments (catheters and guidewires) for a long time to complete the treatment, which may fatigue the doctors and lead to misoperation. Besides, the X-ray radiation in the operating room is also bad for doctors’ health. So, to solve the above challenges, a novel robot-assisted system was developed for VIS, which realizes the separation of the doctor and the operating room; a preliminary method was used on the slave side to reduce the excessive collision force when the tip of the catheter travels through the curved blood vessel, and the active enhancing safety method of the robot-assisted system was proposed to reduce the danger caused by doctors’ misoperation (dangerous behaviors) during the surgery. Finally, to verify the proposed methods, a series of experiments in vitro were conducted, and experimental results indicated that the method of assisting the deflection of the tip of the catheter has the potential to reduce the excessive collision force, the collision force at the tip of the catheter was reduced by 0.104 N when a misoperation occurred during the operation procedure under the condition of the active enhancing safety method, and the stronger sense of the tactile presence was generated by the master manipulator when the total force of the slave side was greater than 1.0 N. Therefore, based on the above results, we believe that the proposed methods are effective.


  • Open Access

    An Endovascular Catheterization Robotic System Using Collaborative Operation with Magnetically Controlled Haptic Force Feedback

    by Xinming Li, Shuxiang Guo, Peng Shi, Xiaoliang Jin, Masahiko Kawanishi

    Robot-assisted technology is often used to perform endovascular catheterization surgeries, which generally depend on the flexible operability and the accurate force feedback of a robotic system. In this paper, an endovascular catheterization robotic system (ECRS) was developed to improve collaborative operation and haptic force feedback. A couple of operating handles were designed to maximize the use of the natural operations of surgeons on the master side, which is a flexible and ergonomic device. A magnetically controlled haptic force feedback structure is proposed based on hydrogel and solid magnetorheological (MR) fluid to offer a sense of haptic feedback to operators; this has potential influence on the field of force feedback. In addition, a unique tremor-reduction structure is introduced to enhance operating safety. Tracking performance experiments and in vitro experiments were conducted to evaluate the performance of the developed ECRS. According to these experimental results, the average translation-tracking error is 0.94 mm, and the average error of rotation is 0.89 degrees. Moreover, in vitro experiments demonstrated that haptic feedback has the advantage of reducing workload and shortening surgery completion time. The developed ECRS also has the benefits of inspiring other researchers to study collaborative robots and magnetically controlled feedback.


  • Total Force Analysis and Safety Enhancing for Operating Both Guidewire and Catheter in Endovascular Surgery

    by Xiaoliang Jin, Shuxiang Guo, Jian Guo, Peng Shi, Takashi Tamiya, Masahiko Kawanishi, Hideyuki Hirata

    In vascular interventional surgery (VIS), the doctors often need to be exposed to X-ray radiation for a long time, operate surgical instruments (Ex. Guidewires and catheters) to perform the operation, which is difficult to ensure the health of surgeons and the safety of operation. In addition, the force between the blood vessel wall and the surgical instrument is complex and variable, the existence of the external disturbance forces easily affects the judgment of the doctors. In this paper, to ensure the health and reduce the fatigue of the doctors, a novel tactile sensing robot-assisted system for VIS was developed to assist the surgeons to complete the operation. Then, the forces between the blood vessel and the surgical instrument during the surgery were analyzed. Besides, a self-developed force sensor was used to confirm the collision force between the tip of the catheter and the blood vessel wall. Finally, combining the haptic force feedback of the system and the developed force sensor, a series of experiments in “Vitro” were completed, and it was indicated by the experiment results that the accuracy of the force feedback can be improved by using the analysis method proposed in this paper, the collision force between the catheter tip and the blood vessel environment can be confirmed by the self-developed force sensor. Based on the results, the developed robot-assisted system for VIS has high safety.


  • Design and Evaluation of a Haptic Robot-Assisted Catheter Operating System With Collision Protection Function

    by Peng Shi, Shuxiang Guo, Linshuai Zhang, Xiaoliang Jin, Hideyuki Hirata, Takashi Tamiya, Masahiko Kawanishi

    In vascular interventional surgery, experienced physicians rely on proximal force sensing to detect the collision and reduce vascular injury caused by surgical tools. However, in robot-assisted tele-interventional surgery (RATIS), providing high-precision force feedback to physician is still a main challenge. In this paper, a haptic robot-assisted catheter operating system with a novel spring-based haptic force interface was developed. With a closed loop force adjustment system, the haptic force interface can provide accuracy force feedback. Moreover, a collision protection function with a proximal-force-based collision detection algorithm was proposed to improve surgical safety. In case of no collision, transparency of the teleoperated system is realized; in case of collision, the provided haptic force will be amplified. The results demonstrated the usability of the developed haptic robot-assisted catheter operating system with collision protection function.


  • An MR Fluids-based Master Haptic Interface with Adjustable Protection Threshold for Endovascular Catheterization

    by Linshuai Zhang, Shuxiang Guo, Shuoxin Gu, Dapeng Song, Peng Shi, Xiaoliang Jin

    Insufficient force feedback and collision warning of teleoperation surgical tools increase the risk of endovascular catheterization. This paper proposed a master haptic interface with the adjustable threshold that takes advantage of a surgeon’s natural manipulation skills obtained through experience, as well as generates collision warning with haptic cues to ensure safe operation. The experiments for performance evaluation regarding the haptic force assessment and the real-time adjustment of threshold are conducted. Results show that the magnitude of the instantaneous haptic change in the haptic interface is sufficient to elicit the operator's response, even for novices. Furthermore, for the setting thresholds after adjustment, the operator has a fast reaction to distinguish whether the catheter tip collides with blood vessels or not by collision warning with haptic cues, thus achieving the goal of safe operation.