Yifei Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yifei Sun has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Baosheng Wang
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
4 shared publications - Xiong Wang
ShanghaiTech University
4 shared publications Chenzhe Li
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2 shared publications- Lejia Zhang
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2 shared publications - Chenzhe Li
School of Information Science and Technology, ShanghaiTech University, 387433 Shanghai, Shanghai, China
1 shared publication - Chenzhe Li
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publication
Latest Publications
- 31 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (20) , 23588-23596
A Low-Cost Compressive Thermoacoustic Tomography System for Hot and Cold Foreign Bodies Detection
Microwave-induced thermoacoustic tomography (MITAT) is suitable for detecting foreign bodies (FBs) in human body due to the sufficient microwave contrast between the FBs and surrounding human tissues. But detection of both hot and cold FBs by the same modality has not been demonstrated. In addition, traditional widely used imaging algorithms for MITAT requires highly intensive measurements, which is not cost-effective or time-efficient. This work reports the application of a low-cost compressive thermoacoustic tomography (CTAT) system for the detection of both hot and cold FBs embedded in tissues, referred to as FBD. We give detailed description of the theory of MITAT and CTAT. We show experimental demonstrations using different shaped metallic samples as the hot FBs and glass and wood samples as the cold FBs. We achieve successful detection of all the hot and cold FBs embedded in different tissues. The CTAT-FBD method is a new paradigm promising for a bunch of diagnosis or sensing applications. It is also possible to build a portable system for this technique.
- 31 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (20) , 23588-23596
A Low-Cost Compressive Thermoacoustic Tomography System for Hot and Cold Foreign Bodies Detection
Microwave-induced thermoacoustic tomography (MITAT) is suitable for detecting foreign bodies (FBs) in human body due to the sufficient microwave contrast between the FBs and surrounding human tissues. But detection of both hot and cold FBs by the same modality has not been demonstrated. In addition, traditional widely used imaging algorithms for MITAT requires highly intensive measurements, which is not cost-effective or time-efficient. This work reports the application of a low-cost compressive thermoacoustic tomography (CTAT) system for the detection of both hot and cold FBs embedded in tissues, referred to as FBD. We give detailed description of the theory of MITAT and CTAT. We show experimental demonstrations using different shaped metallic samples as the hot FBs and glass and wood samples as the cold FBs. We achieve successful detection of all the hot and cold FBs embedded in different tissues. The CTAT-FBD method is a new paradigm promising for a bunch of diagnosis or sensing applications. It is also possible to build a portable system for this technique.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (4) , 371-378
2-D Noninvasive Temperature Measurement of Biological Samples Based on Compressive Thermoacoustic Tomography
There is a great need in temperature monitoring in biomedical applications. The current available temperature measurement techniques have some deficiencies in noninvasiveness, applicability, sensitivity and resolution. Microwave-induced thermoacoustic tomography (MITAT) has found diversified applications in biomedical related disciplines. It has been shown that MITAT can be used to estimate the temperature in a noninvasive manner. However, the applicability of the technique is still limited. This work presents experimental demonstration of two-dimensional (2-D) temperature detection of biological samples based on compressive TAT, referred to as MICTAT. Detailed principle of the method is established. A phantom sample and a biological sample are tested by experiments and 2-D temperature maps are obtained. This work provides a new route of getting 2-D temperature maps of biological samples and may find many applications in biomedical related areas.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (4) , 371-378
2-D Noninvasive Temperature Measurement of Biological Samples Based on Compressive Thermoacoustic Tomography
There is a great need in temperature monitoring in biomedical applications. The current available temperature measurement techniques have some deficiencies in noninvasiveness, applicability, sensitivity and resolution. Microwave-induced thermoacoustic tomography (MITAT) has found diversified applications in biomedical related disciplines. It has been shown that MITAT can be used to estimate the temperature in a noninvasive manner. However, the applicability of the technique is still limited. This work presents experimental demonstration of two-dimensional (2-D) temperature detection of biological samples based on compressive TAT, referred to as MICTAT. Detailed principle of the method is established. A phantom sample and a biological sample are tested by experiments and 2-D temperature maps are obtained. This work provides a new route of getting 2-D temperature maps of biological samples and may find many applications in biomedical related areas.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (1) , 123-130
Microwave-Induced Thermoacoustic Imaging of Small Animals Applying Scanning Orthogonal Polarization Excitation
Microwave-induced thermoacoustic tomography (MITAI) has found diversified applications in biomedical related disciplines. This work reports a novel MITAI modality to homogenize the microwave power deposition in the sample and improve the image quality for small animal imaging via scanning orthogonal polarization (SOP) excitation. Although circular polarization excitation has been reported to enhance MITAI, we perform some simulation works using realistic breast phantoms to prove that the homogeneity of microwave power distribution in the phantoms using orthogonal polarization excitation is comparable to that using circular polarization excitation. Compressive sensing is also applied to enhance the time efficiency of the system. Experiments applying a mouse and a frog sample are conducted. The results indicate that the SOP excitation mechanism can completely reveal the structure of the small animals due to improved power homogeneity. The proposed MITAI-SOP technique is superior to circularly polarized antenna (CPA) based modality since the former avoids the deficiency of CPA in bandwidth, power capacity and efficiency. This work presents a practical and easy-to-implement paradigm for high-quality imaging of small animals and big biological samples using MITAI.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (1) , 123-130
Microwave-Induced Thermoacoustic Imaging of Small Animals Applying Scanning Orthogonal Polarization Excitation
Microwave-induced thermoacoustic tomography (MITAI) has found diversified applications in biomedical related disciplines. This work reports a novel MITAI modality to homogenize the microwave power deposition in the sample and improve the image quality for small animal imaging via scanning orthogonal polarization (SOP) excitation. Although circular polarization excitation has been reported to enhance MITAI, we perform some simulation works using realistic breast phantoms to prove that the homogeneity of microwave power distribution in the phantoms using orthogonal polarization excitation is comparable to that using circular polarization excitation. Compressive sensing is also applied to enhance the time efficiency of the system. Experiments applying a mouse and a frog sample are conducted. The results indicate that the SOP excitation mechanism can completely reveal the structure of the small animals due to improved power homogeneity. The proposed MITAI-SOP technique is superior to circularly polarized antenna (CPA) based modality since the former avoids the deficiency of CPA in bandwidth, power capacity and efficiency. This work presents a practical and easy-to-implement paradigm for high-quality imaging of small animals and big biological samples using MITAI.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 53, 997-998
Investigation on Resolution of Thermoacoustic Imaging Based on Compressive Sensing: A Simulation Study
Microwave-induced thermoacoustic imaging (MITAI) has witnessed tremendous development in the past three decades and numerous related applications have been explored. Compressive sensing (CS) based MITAI is a newly emerging modality that can greatly reduce the number of measurements for obtaining acceptable imaging quality. This work investigates spatial resolution of CS based MITAI by using realistic frequency response of two transducers. Simulation results show that a transducer working at a higher frequency is able to image an object with smaller features. This finding agrees with the established theory of MITAI. This work is useful for potential applications and further improvement of the CS based MITAI technique.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 53, 997-998
Investigation on Resolution of Thermoacoustic Imaging Based on Compressive Sensing: A Simulation Study
Microwave-induced thermoacoustic imaging (MITAI) has witnessed tremendous development in the past three decades and numerous related applications have been explored. Compressive sensing (CS) based MITAI is a newly emerging modality that can greatly reduce the number of measurements for obtaining acceptable imaging quality. This work investigates spatial resolution of CS based MITAI by using realistic frequency response of two transducers. Simulation results show that a transducer working at a higher frequency is able to image an object with smaller features. This finding agrees with the established theory of MITAI. This work is useful for potential applications and further improvement of the CS based MITAI technique.