MKMiyuki Kadokura

Miyuki Kadokura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miyuki Kadokura has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Triaxial Accelerometer Based on a Semicircular Hetero-Core Fiber-Optic Sensor

    by Miyuki Kadokura, Hiroshi Yamazaki, Tokio Kasai, Kazuhiro Watanabe, Michiko Nishiyama

    In this paper, we present the characteristics and performance of a cost-effective triaxial accelerometer using three semicircular hetero-core optical fibers, which are caused optical loss due to mechanical deformation with low transverse sensitivity. In addition to the low transverse sensitivity, calibration with a sensitivity matrix accounts for the residual transverse sensitivity compensation further improved the error of the triaxial accelerometer from 20.2% to 6.97% equivalent to commercial accelerometers. The characteristic quality parameters of the proposed accelerometer include sensitivity in the primary axis, measurement range, bandwidth and discrimination threshold, which were 5.82±1.35 × 10 -3 dB/g, ±74 g, 10–90 Hz and 3.56 × 10 -2 g, respectively. The maximum phase difference was -12.8°due to the viscoelastic property of the UV curable resin fiber coating. The corrected accelerations using the 3 × 3 sensitivity matrix were evaluated under the condition that the triaxial accelerometer was tilted to change the acceleration applied to each axis. We have successfully demonstrated the practical triaxial accelerometer using semicircular optical fiber sensors for early fault detection of industrial machinery.


  • Open Access

    A Fiber-Optic Non-Invasive Swallowing Assessment Device Based on a Wearable Pressure Sensor

    by Masanori Maeda, Miyuki Kadokura, Ryoko Aoki, Noriko Komatsu, Masaru Kawakami, Yuya Koyama, Kazuhiro Watanabe, Michiko Nishiyama

    We developed a wearable swallowing assessment device using a hetero-core fiber-optic pressure sensor for the detection of laryngeal movement during swallowing. The proposed pressure sensor (comfortably attached to the skin of the neck) demonstrated a high sensitivity of 0.592 dB/kPa and a linearity of R2 = 0.995 within a 14 kPa pressure band, which is a suitable pressure for the detection of laryngeal movement. In addition, since the fabricated hetero-core fiber-optic pressure sensor maintains appreciable sensitivity over the surface of the sensor, the proposed wearable swallowing assessment device can accurately track the subtle pressure changes induced by laryngeal movements during the swallowing process. Sixteen male subjects and one female subject were evaluated in a variety of age groups ranging from 30 to 60 years old. For all subjects, characteristic swallowing waveforms (with two valleys based on laryngeal movements consisting of upward, forward, backward, and downward displacements) were acquired using the proposed wearable swallowing assessment device. Since the denoted time of the first valley in the acquired waveform determines the “aging effect”, significant differences in swallowing functions among the different age groups were ultimately determined based on the time of the first valley. Additionally, by analyzing each age group using the proposed device, due to p-values being consistently less than 0.05, swallowing times were found to exhibit statistically significant differences within the same groups.


  • Sensitivity Enhancement of a Semicircular Curved Hetero-Core Optical Fiber Accelerometer With Low Cross-Axis Sensitivity

    by Miyuki Kadokura, Hiroshi Yamazaki, Tokio Kasai, Kazuhiro Watanabe, Michiko Nishiyama

    In this article, the frequency, amplitude, and cross-axis sensitivity characteristics of a hetero-core fiber optic accelerometer subjected to mechanical vibrations are presented. The proposed accelerometer is based on a fixed-support structure and can be used for structural health monitoring. It consists of a semicircular curved hetero-core optical fiber with both ends fixed to a base, which operates as a vibration detector. To increase its sensitivity and reduce its cross-axis sensitivity, a hetero-core portion is placed near one of the fixed ends. By fabricating an ideal semicircular beam-shaped acceleration sensor with both ends fixed, good agreement between the experimentally obtained spectrum results and finite element analysis results when the accelerometer is subjected to mechanical vibrations is observed. The accelerometer’s sensitivity is clearly stable at frequencies less than approximately a quarter of the first natural frequencies of 1810, 850, and 350 Hz with sensitivities of 1.45 $\times 10^{-3}$ , 2.80 $\times 10^{-3}$ , and 6.16 $\times 10^{-3}$ dB/g for fiber curvature radii of 7, 10, and 15 mm, respectively. Owing to its highly linear acceleration characteristics, it is possible to efficiently convert the acceleration to optical loss. The cross-axis sensitivity is in the range 4.27%–15.9%, which is better than that of previously reported accelerometer structures, which use a hetero-core fiber sensor located at the center between the two fixed ends without a free supporting point. Therefore, the proposed accelerometer, which consists only of a semicircular-shaped optical fiber, is capable of improving the sensitivity and reducing the cross-axis sensitivity by adjusting the placement of the hetero-core fiber sensor.


  • Cantilever Type Accelerometer Based on a Mirror-Terminated Hetero-Core Optical Fiber

    by Akihito Matsuo, Miyuki Kadokura, Hiroshi Yamazaki, Michiko Nishiyama, Kazuhiro Watanabe

    This paper describes a novel cantilever type accelerometer using a mirror-terminated hetero-core optical fiber for fault diagnosis of machinery. Hetero-core optical fiber sensors are suitable for long-term measurement in on-site fields with attractive advantages of robustness to environmental disturbances such as electromagnetic interference, chemical corrosion, and temperature fluctuation. Moreover, the proposed sensor contained a mirror termination on the hetero-core fiber in order to form a compact and cantilever-shaped structure. It was experimentally found that the mirror-terminated hetero-core fiber worked as Mach-Zehnder interferometry having interference fringes in transmission spectrum, in which linear changes in peak intensities enabled to detect the deflection of fiber beam using a cost-effective LED/PD measurement instrument. For the vibration response characteristics, the sensor reproduced the waveforms of input vibrations to optical loss changes when sinusoidal vibration was applied. Furthermore, the sensitivities were stable in the range of $5.4\times10^{3}$ to $2.3\times10^{2}$ dB/g for the frequency ranges less than 620–130 Hz, when setting a fiber beam length by 6–13 mm. Additionally, finite element simulations indicated that the frequency response characteristics were well correlated with the vibration characteristics of the cantilever-shaped fiber beam, which implied that the sensor performance can be optimized with respects to the sensitivity and the measurable frequency range by changing the fiber beam length.