Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nir Fink has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical Prevalence and Impact of False Air–Bone Gaps in Clinical Audiometry: A Study of 1,000 Ears

    by Shai Chordekar, Liron Kariv, Nir Fink

    Purpose: Accurate hearing loss classification depends on air–bone relationships; however, “false” air–bone gaps (ABGs) in sensorineural hearing loss (SNHL) frequently compromise diagnostic clarity. By shifting the focus from ABG magnitude to clinical prevalence, this study uses the prevalence of clinical ABGs (≥ 15 dB) as a primary metric to quantify diagnostic ambiguity in routine practice and to evaluate the efficacy of bone-conduction (BC) testing at frequencies where frequent false ABGs occur. Method: We retrospectively analyzed audiometric data from 1,000 ears (500 adults). The analysis focused on the prevalence of clinical ABGs and ABG magnitudes across the tested frequencies, including a secondary analysis of their relationship with hearing loss severity. The clinical utility of the 250-Hz BC threshold was evaluated by examining whether audiologists relied on an isolated 250-Hz ABG when classifying hearing loss as conductive or mixed. Results: False ABGs in SNHL were most common at 250 Hz (43.5%) and 4000 Hz (13.9%), with an increasing severity of hearing loss. Audiologists did not rely on isolated ABG at 250 Hz to classify hearing loss as conductive, as all confirmed conductive/mixed cases were detected by ABGs at other frequencies. At 4000 Hz, false ABGs were intensity-dependent artifacts, mainly appearing when the air-conduction thresholds were 50 dB HL. Conclusions: False ABGs often occur at 250 and 4000 Hz. Routine 250-Hz BC testing is unnecessary for most adults and lacks diagnostic value. Focusing on the 500- to 4000-Hz range and using the cross-check principle for 4000-Hz high-intensity thresholds will improve accuracy and efficiency.

  • Recommended Audiological Test Battery Following Combat Noise Exposure: A Clinical Approach

    by Shai Chordekar, Devora Brand, Orit Svetlana Leiderman Badash, Cahtia Adelman, Rachel Fraenkel, Nitza Horev, Anat Ben Horin, Nir Fink

    Purpose: The purpose of this study was to establish a standardized, evidence-based audiological protocol for evaluating combat-exposed personnel and civilians. This comprehensive test battery emphasizes early detection, detailed assessment, and practical clinical implementation. This protocol addresses the current gap in assessment approaches for combat-related hearing injuries. Method: This protocol represents a comprehensive audiological assessment framework for combat noise exposure based on evidence-based practice developed by a working group of clinical audiologists. The protocol integrates a specialized form for documenting combat noise exposure history, conventional audiometry (0.25–8.0 kHz), extended high-frequency audiometry (9.0–20.0 kHz), otoacoustic emissions, immittance testing, and auditory evoked potentials. The recommended testing sequence begins with a comprehensive medical history intake followed by otoscopic examination, with the subsequent assessment order determined by clinician judgment and patient capacity. The interpretation criteria account for combat noise exposure characteristics, including blast effects and confounding factors such as traumatic brain injury and psychological trauma. This protocol enables auditory dysfunction detection even when standard audiometric results appear normal, facilitating a more accurate assessment of combat-related hearing impairment and early detection. Conclusions: This protocol advances the current clinical practice by providing a standardized and comprehensive approach for evaluating combat noise–induced auditory dysfunction. The test battery's integration of multiple assessment tools and specific interpretation guidelines enhances the clinicians' ability to detect and monitor auditory changes following combat noise exposure. The protocol's emphasis on early detection and practical implementation guidelines supports clinical decision-making and long-term monitoring strategies. While this protocol advances the current practice of evaluating combat-related auditory dysfunction, validation studies in military and clinical settings are required to establish its effectiveness.


  • Exploring the impact of physical activity on speech comprehension in loud noise while using hearing protection (L)

    by Shai Chordekar, Eli Kurtzman, Orlev Levy-Nissenbaum, Nir Fink

    This study examines how physical activity affects speech comprehension in noise while using hearing protection devices (HPDs). Forty-one participants, using either earplugs or earmuffs, were tested under four conditions (rest vs moderate activity and with vs without HPDs). Speech comprehension was assessed using the signal-to-noise ratio required for 50% accuracy. Results show that HPDs improve speech comprehension in high noise (95 dB SPL) by reducing external noise, despite increased internal noise from physical exertion. Findings highlight the dual effect of HPDs-enhancing speech perception in noise while potentially amplifying physiological sounds, influencing overall listening outcomes.


  • Open Access

    Measuring “Where”: A Comparative Analysis of Methods Measuring Spatial Perception

    by Leah Fostick, Nir Fink

    The literature offers various methods for measuring sound localization. In this study, we aimed to compare these methods to determine their effectiveness in addressing different research questions by examining the effect sizes obtained from each measure. Data from 150 participants who identified the location of a sound source were analyzed to explore the effects of speaker angle, stimuli, HPD type, and condition (with/without HPD) on sound localization, using six methods for analysis: mean absolute deviation (MAD), root-mean-squared error (RMSE), very large errors (VLE), percentage of errors larger than the average error observed in a group of participants (pMean), percentage of errors larger than half the distance between two consecutive loudspeakers (pHalf), and mirror image reversal errors (MIRE). Results indicated that the MIRE measure was the most sensitive to the effects of speaker angle and HPD type, while the VLE measure was most sensitive to the effect of stimuli type. The condition variable provided the largest effect sizes, with no difference observed between measures. The data suggest that when effect sizes are substantial, all methods are adequate. However, for cases where the effect size is expected to be small, methods that yield larger effect sizes should be considered, considering their alignment with the research question.


  • Open Access

    Evaluation of sound localization and speech recognition with a sound enhancing connection tube for non-linear earplugs

    by Nir Fink, Aaron Benn, Liron Grushko

    Noise-induced hearing-loss (NIHL) can occur when an individual is exposed to high-intensity acoustic stimuli. To prevent NIHL, individuals may use non-linear-earplugs (NLEPs) that provide some attenuation, substantially within the frequency range of 1–4 kHz. Wearing NLEPs can reduce speech recognition as well as sound localization. As weapon noise is mostly present in the 1–4 kHz range and is therefore partly attenuated by NLEPs, there is a downside to the reduced ability of a soldier using them to localize the source of enemy gunfire. A perforated sound-enhancing connection tube (SECT) was designed to connect to NLEPs for improving the user’s ability to localize sound and speech recognition in noise while retaining the NLEPs's noise attenuation benefits of protecting one's hearing. A previous experiment examined the effect of the SECT with NLEPs on the Head Related Transfer Function (HRTF) of a head-and-torso-simulator (HATS) (manikin). The obtained HRTF demonstrated a 3–10 dB difference in the 1–4 kHz frequency range relative to the HRTF with the NLEPs alone, implying that sound stimuli in that frequency range might be more audible to the user. The presented work will demonstrate the speech recognition in noise and sound localization of participants when using the SECT with NLEPs.

  • Open Access

    Perforated Concave Earplug (pCEP): A Proof-of-Concept Earplug to Improve Sound Localization without Compromising Noise Attenuation

    by Nir Fink, Rachel Levitas, Arik Eisenkraft, Linn Wagnert-Avraham, S. David Gertz, Leah Fostick

    Combat soldiers are currently faced with using a hearing-protection device (HPD) at the cost of adequately detecting critical signals impacting mission success. The current study tested the performance of the Perforated-Concave-Earplug (pCEP), a proof-of-concept passive HPD consisting of a concave bowl-like rigid structure attached to a commercial roll-down earplug, designed to improve sound localization with minimal compromising of noise attenuation. Primarily intended for combat/military training settings, our aim was an evaluation of localization of relevant sound sources (single/multiple gunfire, continuous noise, spoken word) compared to 3M™-Combat-Arms™4.1 earplugs in open-mode and 3M™-E-A-R™-Classic™ earplugs. Ninety normal-hearing participants, aged 20–35 years, were asked to localize stimuli delivered from monitors evenly distributed around them in no-HPD and with-HPD conditions. The results showed (1) localization abilities worsened using HPDs; (2) the spoken word was localized less accurately than other stimuli; (3) mean root mean square errors (RMSEs) were largest for stimuli emanating from rear monitors; and (4) localization abilities corresponded to HPD attenuation levels (largest attenuation and mean RMSE: 3M™-E-A-R™-Classic™; smallest attenuation and mean RMSE: 3M™-Combat-Arms™4.1; pCEP was mid-range on both). These findings suggest that the pCEP may benefit in military settings by providing improved sound localization relative to 3M™ E-A-R™-Classic™ and higher attenuation relative to 3M™-Combat Arms™-4.1, recommending its use in noisy environments.


  • Open Access

    Efficacy of Oral Steroids for Acute Acoustic Trauma

    by Elchanan Zloczower, Nir Tsur, Shir Hershkovich, Nir Fink, Tal Marom

    Objective: This study aimed to study the effect of steroid treatment on new-onset sensorineural hearing loss (SNHL) in subjects presenting shortly after an audiometry-confirmed acute acoustic trauma (AAT) injury. Study Design: This is a case-control study. Methods: We identified healthy military personnel who presented with AAT injury to the Israeli Defense Forces Medical Corps Otolaryngology/Audiology Services during 2016–2020. Patients were nonrandomly allocated to a treatment arm, where they received steroids (prednisone, 1 mg/kg, 60 mg maximal daily dose), administered for either ≥7 days or 35 dB). No statistically significant differences were observed in AC/BC pure tone average between the two groups. Conclusions: Early oral steroids are recommended in AAT injuries and were shown to improve hearing outcomes within 1 month.


  • Open Access

    Situational Awareness: The Effect of Stimulus Type and Hearing Protection on Sound Localization

    by Leah Fostick, Nir Fink

    The purpose of the current study was to test sound localization of a spoken word, rarely studied in the context of localization, compared to pink noise and a gunshot, while taking into account the source position and the effect of different hearing protection devices (HPDs) used by the listener. Ninety participants were divided into three groups using different HPDs. Participants were tested twice, under with- and no-HPD conditions, and were requested to localize the different stimuli that were delivered from one of eight speakers evenly distributed around them (starting from 22.5°). Localization of the word stimulus was more difficult than that of the other stimuli. HPD usage resulted in a larger mean root-mean-square error (RMSE) and increased mirror image reversal errors for all stimuli. In addition, HPD usage increased the mean RMSE and mirror image reversal errors for stimuli delivered from the front and back, more than for stimuli delivered from the left and right. HPDs affect localization, both due to attenuation and to limitation of pinnae cues when using earmuffs. Difficulty localizing the spoken word should be considered when assessing auditory functionality and should be further investigated to include HPDs with different attenuation spectra and levels, and to further types of speech stimuli.