YDYakai Dong

Yakai Dong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yakai Dong has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multi-Frequency Electric Field Measurement Method for Optical Under-Sampling System

    by Yan Yang, Shuguo Xie, Tianheng Wang, Yakai Dong, Xin Zhao, Meiling Yang

    This paper introduces an under-sampling E-field measurement system involving three femtosecond pulse lasers, which can be used to measure a multi-frequency electric field (E-field) in a wide frequency range. Optical under-sampling technology utilizes femtosecond laser pulses to sample the electrical signals and convert the high-frequency signal down to the first pulse repetition frequency (RPF) intervals for measurement, i.e., tens to hundreds of MHz. However, previous work rarely studied the measurement of multi-frequency signals. Therefore, in this work, we use three RPFs and propose the Remainder Matching (RM) method of three RPFs to eliminate false-alarm-triggered frequencies. Moreover, to solve the challenging problem of grouping the down-conversion components of each measured frequency, we suggest the Eigenvalue Matching of Remainder’s Difference (EMRD) method to obtain the correct group accurately. Hence, this work combines the RM and EMRD methods to improve the system’s measurement accuracy. To evaluate the suggested measurement technique, detailed theoretical analysis and simulation are performed to demonstrate the universality of our method that can effectively guide the design of E-field measuring systems using optical under-sampling technology. The proposed scheme manages an error rate less than 0.1% without any measurement error of the down-converted components when six frequencies exist simultaneously and is less than 5% when the measured frequency deviation is ±25kHz. Finally, the proposed system is challenged on noise perturbations, with the results demonstrating that the suggested combined RM and RDEM scheme attains an appealing performance.


  • A Frequency Recovering Method for Photonic Under-Sampling E-Field Measurement

    by Yan Yang, Shuguo Xie, Yakai Dong, Tianheng Wang, Xin Zhao

    An electric field measurement system with two optical pulse sources down-converts the high-frequency electric signal to the baseband through a probe exploiting the electro optic-effect. From that process, it is feasible to recover the measured frequency. However, the majority of the current studies focus on the case where the difference between the two repetition frequencies is quite small, while only a few involve larger frequency differences. Nevertheless, in a non-laboratory uncontrolled environment such as a field measurement, it is commonly unfeasible to guarantee a small frequency difference imposing further study on frequency recovery methods under larger frequency difference. Spurred by that, in this paper we propose a universal frequency recovery algorithm relying on the Remainder Matching (RM) technique, which is suitable for both large and small frequency differences. In our method, we employ the RM technique to determine the exact remainder combination in the first repetition frequency intervals and calculate the measured frequency. We also present the theoretical basis of RM, along with a summary of the system design rules, which have a significant impact on the performance of the measurement system. Finally, we challenge our RM-based solution on noise and analyze the corresponding false alarm rate metric. Our results demo nstrate that the proposed RM-based frequency recovery algorithm attains an appealing performance.