Karen Christine Lacerda Arnaud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karen Christine Lacerda Arnaud has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Andressa Cartaxo de Almeida
Faculdade de Odontologia de Pernambuco
1 shared publication - Fábio Luiz Cunha Dassunção
Universidade Federal da Paraíba
1 shared publication - Jozemar Pereira dos Santos
Universidade Federal da Paraíba
1 shared publication - Juan Ramon Salazar-Silva
Universidade Federal da Paraíba
1 shared publication - Thiago Bezerra Leite
Universidade Federal da Paraíba
1 shared publication - Verônica Cabral dos Santos Cunha D'Assunção
Federal University of Paraiba, Brazil
1 shared publication
Latest Publications
- Open Access
- 2 October 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (13)
Evaluation of the effect of irrigants on the accuracy and repeatability of three electronic apex locators: an ex vivo study
Objective: To evaluate the effect of 2% chlorhexidine (CHX) and 2.5% sodium hypochlorite (NaOCl) on the accuracy and repeatability of three Electronic Apex Locators (EALs). Methodology: Thirty one human teeth were connected to a platform, irrigated with 2.0% CHX, and obtained two readings, again irrigated with 2.5% NaOCl and obtained two more readings. The distance between the tip of the file and the apical constriction was measured. Repeatability was calculated using the intraclass correlation coefficient (ICC) and repeatability coefficient (CR). Results: For CHX 2%, with the Mini Apex Locator, 25 of 31 electronic measurements were accurate (80.6%), 28 of 31 measurements for iPex (90.3%) and for Root ZX II 26 (83, 9%). For 2.5% NaOCl, with the Mini Apex Locator, 25 of the 31 measurements were accurate (80.6%), 28 of the 31 measurements for the iPex (90.3%) and for the Root ZX II, 24 (77, 4%). There were no differences between the two irrigants (p>0.05). The values (ICC) were 0.975 and 0.994 for the Mini Apex Locator, 0.981 and 0.971 for the i Pex and 0.994 and 0.995 for the Root ZX II. When using CHX, the (CR) was 0.196 for the Mini Apex Locator, 0.152 for the iPex and 0.088 for the Root ZX II. When using 2.5% NaOCl, the (CR) was 0.088 for the Mini Apex Locator, 0.196 for the iPex and 0.088 for the Root ZX II. Conclusions: The use of 2% CHX and 2.5% NaOCl did not affect the accuracy and repeatability of the three devices.
- 2 October 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (13)
Open AccessEvaluation of the effect of irrigants on the accuracy and repeatability of three electronic apex locators: an ex vivo study
Objective: To evaluate the effect of 2% chlorhexidine (CHX) and 2.5% sodium hypochlorite (NaOCl) on the accuracy and repeatability of three Electronic Apex Locators (EALs). Methodology: Thirty one human teeth were connected to a platform, irrigated with 2.0% CHX, and obtained two readings, again irrigated with 2.5% NaOCl and obtained two more readings. The distance between the tip of the file and the apical constriction was measured. Repeatability was calculated using the intraclass correlation coefficient (ICC) and repeatability coefficient (CR). Results: For CHX 2%, with the Mini Apex Locator, 25 of 31 electronic measurements were accurate (80.6%), 28 of 31 measurements for iPex (90.3%) and for Root ZX II 26 (83, 9%). For 2.5% NaOCl, with the Mini Apex Locator, 25 of the 31 measurements were accurate (80.6%), 28 of the 31 measurements for the iPex (90.3%) and for the Root ZX II, 24 (77, 4%). There were no differences between the two irrigants (p>0.05). The values (ICC) were 0.975 and 0.994 for the Mini Apex Locator, 0.981 and 0.971 for the i Pex and 0.994 and 0.995 for the Root ZX II. When using CHX, the (CR) was 0.196 for the Mini Apex Locator, 0.152 for the iPex and 0.088 for the Root ZX II. When using 2.5% NaOCl, the (CR) was 0.088 for the Mini Apex Locator, 0.196 for the iPex and 0.088 for the Root ZX II. Conclusions: The use of 2% CHX and 2.5% NaOCl did not affect the accuracy and repeatability of the three devices.