LWLiming Wu

Liming Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Liming Wu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Xiaomin Liu

    School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China

    3 shared publications
  • Chen-Yin Pong

    Ching Yun University, Department of Electrical Engineering, 229, Chien-Hsin Rd., Jung-Li, Taiwan 320, R.O.C.

    1 shared publication
  • Chenye Tian

    School of Energy and Power Engineering

    1 shared publication
  • Gang Liu

    School of Energy and Power Engineering, Xi'an Jiaotong University , No. 28, Xianning West Road, Xi'an, Shaanxi 710049, China

    1 shared publication
  • Guang Xi

    School of Energy and Power Engineering, Xi'an Jiaotong University , No. 28, Xian Ning West Road, Xi'an, Shaanxi, 710049, People's Republic of China

    1 shared publication
  • Mingjun Wen

    Mechanical and Automotive Engineering College, Taiyuan University , Taiyuan, Shaanxi, People's Republic of China

    1 shared publication

Latest Publications

  • Open Access

    Numerical study on aerodynamic and noise performance of bionic asymmetric airfoil with surface grooves

    by Mingjun Wen, Liming Wu

    Based on the asymmetric NACA4412 baseline airfoil, a bionic airfoil with surface grooves is presented. For the bio-inspired airfoil, non-smooth grooves are placed on the trailing edge of NACA4412 airfoil. To reveal the effects of non-smooth structures of the trailing edge on the aerodynamic and noise performance of airfoil, large eddy simulation and Ffowcs Williams–Hawkings acoustic analogy are adopted to investigate the aerodynamic performance and acoustic characteristics of the baseline NACA4412 airfoil and bionic airfoil at the chord-based Reynolds number, Re = 1.2 ×105. The numerical results show that the aerodynamic performance of the bionic airfoil is better than that of the baseline airfoil when the angle of attack is 14°. For all the sound frequencies studied in this study, the overall sound pressure level of the bionic airfoil is reduced by 2.0 dB at angle of attack is 14°. At the same time, the mechanisms of flow control and noise reduction of non-smooth surface grooves at the trailing edge are also revealed. As a result, the presence of surface grooves near the trailing edge of the airfoil can effectively improve the aerodynamic performance and reduce the aerodynamic noise of the traditional asymmetric airfoil, especially at high angles of attack.


  • Using the combined flow control accessory to the aerodynamic performance enhancement of bio-inspired seagull airfoils

    by Liming Wu, Xiaomin Liu, Yang Liu, Guang Xi

    An airfoil with good stability and a high lift-drag ratio can effectively improve the stability and aerodynamic performance of the wind turbine blade. Inspired by the excellent gliding performance of the seagull wings, the unique profile and structure of the seagull wings are first extracted to restructure the bionic airfoil. Then, the flow control accessory combined the bionic flap and Gurney flap is introduced to further improve the static and dynamic aerodynamic performance of bionic seagull airfoil. Under different Reynolds numbers, the effects of the combined flow control accessory on the bionic seagull airfoil are investigated using the numerical simulation method. Based on the analysis of flow fields, the flow control mechanism of the combined flow control accessory on the stall characteristics of bionic seagull airfoil is revealed. The results show that for the static stall characteristics, when the flow control accessory is applied to the bionic airfoil, the static lift coefficient of the airfoil is increased by 15% at Reynolds numbers of Re 2.0 × 105. For the dynamic stall characteristics, the lift coefficient of the airfoil is improved during the whole dynamic stall process, the maximum is increased by 13.12%, and the area of the dynamic hysteresis loop is reduced.


  • Energy extraction of oscillating foil with an active deflecting trailing-edge flap

    by Gang Liu, Chenye Tian, Liming Wu, Xiaomin Liu

    The method of oscillating-foil energy extraction can be used to extract kinetic energy from the surrounding flow by a combined pitching and heaving motion of the foil. In order to improve the efficiency of energy extraction, a slotted foil with an active deflecting trailing-edge flap—inspired by the structure of the tail edge of bird wings—is designed. In this study, the unsteady Reynolds-averaged Navier–Stokes equation is solved to investigate the energy extraction performance of an oscillating foil at a Reynolds number of 5.0 × 105. In the numerical simulation, the dynamic overset mesh technology is used in order to ensure the accuracy and convergence of numerical solution. The effect of the deflecting motion of trailing-edge flaps on the efficiency of energy extraction is studied at a range of oscillating frequencies. In addition, the flow control mechanisms of slots on the oscillating foil are revealed by comparing the flow fields of the slotted foil and the NACA0015 foil. The result shows that active deflecting trailing-edge flaps can improve the efficiency of energy extraction over a wide range of oscillation frequencies. The active deflection of trailing-edge flaps increases the energy extraction efficiency of oscillating foils by 21.1% relative to conventional foils under a specific operating condition of oscillating frequency f* = 0.18. A detailed analysis of the flow fields indicates that the slot on the foil can suppress flow separation, while it has a negative effect on the attachment of leading-edge vortices. The deflecting trailing-edge flap enhances the heaving force. Therefore, the energy output and the efficiency of the oscillating foil are enhanced especially at the operating conditions of the oscillating foil without leading-edge vortex shedding.


  • Open Access

    Dynamic Stall Characteristics of the Bionic Airfoil with Different Waviness Ratios

    by Liming Wu, Xiaomin Liu

    A dynamic stall will cause dramatic changes in the aerodynamic performance of the blade, resulting in a sharp increase in the blade vibration load. The bionic leading-edge airfoil with different waviness ratios, inspired by the humpback whales flipper, is adopted to solve this problem. In this study, based on the NACA0015 airfoil, the three-dimensional unsteady numerical simulation and sliding mesh technique are used to reveal the flow control mechanism on the dynamic stall of the bionic wavy leading edge. The effects of the waviness ratio on the dynamic stall characteristics of the airfoil are also investigated. The results show that the peak drag coefficient is dramatically reduced when a sinusoidal leading edge is applied to the airfoil. Although the peak lift coefficient is also reduced, the reduction is much smaller. When the waviness ratio R is 0.8, the peak drag coefficient of the airfoil is reduced by 17.14% and the peak lift coefficient of the airfoil is reduced by 9.20%. The dynamic hysteresis effect is improved gradually with an increasing waviness ratio. For the bionic airfoil with R = 1.0, the area of the hysteresis loop is the smallest.


  • A half bridge flyback converter with ZVS and ZCS operations

    by Li-Ming Wu, Chen-Yin Pong

    An asymmetrical half bridge flyback converter without output inductor is presented in this paper, in which the power switches can be turned on with ZVS and the output diode can be turned on and off with ZCS. While the ZVS is obtained from the magnetizing current, the ZCS is achieved from the resonant current. The ZVS and ZCS conditions can be maintained for full load range. The characteristics of the proposed converter rely on the utilization of resonant inductor and blocking capacitor as resonant energy delivery devices rather than linearly charging and discharging components. The operational principle and circuit analysis of the proposed converter is described in this paper. The experimental test of a 90 W prototype converter is performed and the results are presented.