Yalaka Rami Reddy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yalaka Rami Reddy has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Kondal Reddy Mogili
Department of Medical Gastroenterology, Star Hospitals, Hyderabad, India
4 shared publicationsChandan Kumar Kedarisetty
Gleneagles Global Hospitals, Hyderabad, India
2 shared publicationsPankaj Gupta
Department of Radiodiagnosis, Postgraduate Institute of Medical Education and Research, Chandigarh, India
2 shared publicationsRakesh Kochhar
Department of Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
2 shared publicationsSaroj K. Sinha
Department of Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
2 shared publicationsAbhign Chennamadhavuni
Department of Medical Gastroenterology, Star Hospitals, Hyderabad, India
1 shared publication
Latest Publications
- Open Access
- 8 January 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 01) , E449-E450
A novel assisted technique for difficult 24-hour esophageal pH-impedance probe placement
Twenty-four-hour pH monitoring involves the transnasal placement of a thin, flexible probe for the evaluation of gastroesophageal reflux disease [1] [2] [3]. Excessive probe flexibility may lead to buckling and coiling, particularly in patients with altered anatomy like hiatal hernia, esophageal tortuosity, diverticula, or extrinsic compression or post-surgical changes and those with poor cooperation or a pronounced gag reflex. Common facilitating and alternative maneuvers include adequate lubrication, the swallow-and-advance technique, chin-tuck maneuver and head rotation. We demonstrate a simple technique to improve deliverability in difficult insertions. A 60-year-old woman diagnosed with reflux esophagitis, sliding hiatal hernia and post-sleeve gastrectomy was referred for 24-hour pH study ([Fig. 1]). Repeated transnasal attempts using a 6.4-Fr pH probe failed because of persistent coiling at the oropharynx. To facilitate advancement, the distal tip of the pH probe was introduced into the distal side port of a 16-Fr nasogastric tube, creating a temporary nasogastric tube-pH probe assembly ([Fig. 2]). The nasogastric tube was selected for its relative stiffness and ready availability. The assembly was advanced transnasally under fluoroscopic guidance. As buckling persisted, biopsy forceps were inserted ex-vivo into the nasogastric tube lumen up to 5 cm short of the tip, without exiting the side ports, thereby providing additional stiffness and improved directional control ([Fig. 3]). This reinforced assembly enabled smooth passage across the esophagogastric junction. Under fluoroscopic guidance, the nasogastric tube was gently advanced while the pH probe was stabilized at the nostril, allowing successful separation ([Video 1]). The probe was accurately positioned without adverse events ([Fig. 4]). The patient tolerated the procedure with minimal discomfort, and the study was completed successfully. This simple, reproducible technique may improve procedural efficiency and success in carefully selected patients with difficult pH probe placement. Endoscopy_UCTN_Code_CCL_1AB_2AH Endoscopy_UCTN_Code_CCL_1AB_2AC_3AC Article published online: 26 March 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 8 January 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 01) , E449-E450
Open AccessA novel assisted technique for difficult 24-hour esophageal pH-impedance probe placement
Twenty-four-hour pH monitoring involves the transnasal placement of a thin, flexible probe for the evaluation of gastroesophageal reflux disease [1] [2] [3]. Excessive probe flexibility may lead to buckling and coiling, particularly in patients with altered anatomy like hiatal hernia, esophageal tortuosity, diverticula, or extrinsic compression or post-surgical changes and those with poor cooperation or a pronounced gag reflex. Common facilitating and alternative maneuvers include adequate lubrication, the swallow-and-advance technique, chin-tuck maneuver and head rotation. We demonstrate a simple technique to improve deliverability in difficult insertions. A 60-year-old woman diagnosed with reflux esophagitis, sliding hiatal hernia and post-sleeve gastrectomy was referred for 24-hour pH study ([Fig. 1]). Repeated transnasal attempts using a 6.4-Fr pH probe failed because of persistent coiling at the oropharynx. To facilitate advancement, the distal tip of the pH probe was introduced into the distal side port of a 16-Fr nasogastric tube, creating a temporary nasogastric tube-pH probe assembly ([Fig. 2]). The nasogastric tube was selected for its relative stiffness and ready availability. The assembly was advanced transnasally under fluoroscopic guidance. As buckling persisted, biopsy forceps were inserted ex-vivo into the nasogastric tube lumen up to 5 cm short of the tip, without exiting the side ports, thereby providing additional stiffness and improved directional control ([Fig. 3]). This reinforced assembly enabled smooth passage across the esophagogastric junction. Under fluoroscopic guidance, the nasogastric tube was gently advanced while the pH probe was stabilized at the nostril, allowing successful separation ([Video 1]). The probe was accurately positioned without adverse events ([Fig. 4]). The patient tolerated the procedure with minimal discomfort, and the study was completed successfully. This simple, reproducible technique may improve procedural efficiency and success in carefully selected patients with difficult pH probe placement. Endoscopy_UCTN_Code_CCL_1AB_2AH Endoscopy_UCTN_Code_CCL_1AB_2AC_3AC Article published online: 26 March 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 4 January 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 01) , E996-E997
Novel technique of cholangioscopy-guided inwardly migrated stent retrieval
We present a case of a 54-year-old man who had undergone a liver transplant and developed a biliary anastomotic stricture. The patient underwent endoscopic retrograde cholangiopancreatography (ERCP) and stenting for the treatment of the condition. He visited our facility for a stent exchange. During the ERCP procedure, it was discovered that one of the stents had migrated inward ([Fig. 1]). Despite multiple attempts using the biliary balloon, basket, and snare for stent extraction, all efforts were unsuccessful [1] [2] [3] [4]. Consequently, we decided to perform cholangioscopy (SpyGlass DS; Boston Scientific, Marlborough, Massachusetts, USA), which revealed that the distal end of the stent was lodged in the wall of the distal common bile duct ([Video 1]). However, the deep impaction made it impossible to employ the spy snare. Therefore, we opted to disimpact the stent [5]. Video 1 Novel technique of cholangioscopy-guided inwardly migrated stent retrieval. During cholangioscopy, we identified a side opening at the distal flange of the stent. We inserted a guidewire through the side hole and into the stent lumen. Subsequently, we exchanged the cholangioscope with a sphincterotome (Ultratome; Boston Scientific) over the guidewire, engaging it into the side hole of the stent. By pushing the stent inward, we successfully disimpacted the distal end. Once disimpaction was achieved, we replaced the sphincterotome with a routine snare over the guidewire. Under fluoroscopy guidance, we captured the distal end of the stent with the snare. Finally, the guidewire, stent, and snare complex were retrieved along with the scope ([Fig. 2–5]). We then placed two new plastic stents across the stricture. To the best of our knowledge, this is the first case report highlighting the successful use of cholangioscope-guided guidewire cannulation through the side hole and the utilization of a sphincterotome and routine snare for the retrieval of a migrated stent, thus obviating the need for surgery. Endoscopy_UCTN_Code_CPL_1AK_2AD Article published online: 21 August 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 4 January 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 01) , E996-E997
Open AccessNovel technique of cholangioscopy-guided inwardly migrated stent retrieval
We present a case of a 54-year-old man who had undergone a liver transplant and developed a biliary anastomotic stricture. The patient underwent endoscopic retrograde cholangiopancreatography (ERCP) and stenting for the treatment of the condition. He visited our facility for a stent exchange. During the ERCP procedure, it was discovered that one of the stents had migrated inward ([Fig. 1]). Despite multiple attempts using the biliary balloon, basket, and snare for stent extraction, all efforts were unsuccessful [1] [2] [3] [4]. Consequently, we decided to perform cholangioscopy (SpyGlass DS; Boston Scientific, Marlborough, Massachusetts, USA), which revealed that the distal end of the stent was lodged in the wall of the distal common bile duct ([Video 1]). However, the deep impaction made it impossible to employ the spy snare. Therefore, we opted to disimpact the stent [5]. Video 1 Novel technique of cholangioscopy-guided inwardly migrated stent retrieval. During cholangioscopy, we identified a side opening at the distal flange of the stent. We inserted a guidewire through the side hole and into the stent lumen. Subsequently, we exchanged the cholangioscope with a sphincterotome (Ultratome; Boston Scientific) over the guidewire, engaging it into the side hole of the stent. By pushing the stent inward, we successfully disimpacted the distal end. Once disimpaction was achieved, we replaced the sphincterotome with a routine snare over the guidewire. Under fluoroscopy guidance, we captured the distal end of the stent with the snare. Finally, the guidewire, stent, and snare complex were retrieved along with the scope ([Fig. 2–5]). We then placed two new plastic stents across the stricture. To the best of our knowledge, this is the first case report highlighting the successful use of cholangioscope-guided guidewire cannulation through the side hole and the utilization of a sphincterotome and routine snare for the retrieval of a migrated stent, thus obviating the need for surgery. Endoscopy_UCTN_Code_CPL_1AK_2AD Article published online: 21 August 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 1 March 2022
- Published by Georg Thieme Verlag KG in Journal of Digestive Endoscopy
- Vol. 13 (01) , 044-045
A Novel Method of Esophageal Impacted Sharp Foreign Body Retrieval
A 54-year-old woman presented with dysphagia after meat ingestion. On contrast enhanced computed tomography, bony fragment with sharp edges impacted in the esophageal wall was found just beyond the upper esophageal sphincter ([Fig. 1]). On retrieval attempt during endoscopy with foreign body forceps (Cook Medical, Wilson-Salem, North Carolina, United States), further injury to esophageal wall was noted due to impacted sharp margins. To avoid further damage, the foreign body was pushed distally with the help of foreign body forceps. This maneuver disimpacted its sharp edges from esophageal wall. Subsequently, we sprayed glue (n-butyl-2-cyanoacrylate) (Samarth Life Sciences, Mumbai, Maharashtra, India) around the foreign body. This measure solidified it and blunted its sharp edges facilitating safe retrieval of the foreign body using Roth net (US endoscopy, Mentor, Ohio, United States) ([Fig. 2], [Video 1]). Video 1 Impacted foreign body was pushed distally with the help of foreign body forceps and glue applied around the foreign body. After solidification of glue foreign body retrieved with Roth net. Our technique averted severe trauma to esophagus. Glue (n-butyl-2-cyanoacrylate) polymerizes after contact with weak bases. It is commonly used for variceal obliteration and closure of fistulae.[1] [2] [3] This technique is a safe alternative in specific cases of sharp foreign body retrieval. Publication Date: 25 April 2022 (online) © 2022. Society of Gastrointestinal Endoscopy of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 March 2022
- Published by Georg Thieme Verlag KG in Journal of Digestive Endoscopy
- Vol. 13 (01) , 044-045
Open AccessA Novel Method of Esophageal Impacted Sharp Foreign Body Retrieval
A 54-year-old woman presented with dysphagia after meat ingestion. On contrast enhanced computed tomography, bony fragment with sharp edges impacted in the esophageal wall was found just beyond the upper esophageal sphincter ([Fig. 1]). On retrieval attempt during endoscopy with foreign body forceps (Cook Medical, Wilson-Salem, North Carolina, United States), further injury to esophageal wall was noted due to impacted sharp margins. To avoid further damage, the foreign body was pushed distally with the help of foreign body forceps. This maneuver disimpacted its sharp edges from esophageal wall. Subsequently, we sprayed glue (n-butyl-2-cyanoacrylate) (Samarth Life Sciences, Mumbai, Maharashtra, India) around the foreign body. This measure solidified it and blunted its sharp edges facilitating safe retrieval of the foreign body using Roth net (US endoscopy, Mentor, Ohio, United States) ([Fig. 2], [Video 1]). Video 1 Impacted foreign body was pushed distally with the help of foreign body forceps and glue applied around the foreign body. After solidification of glue foreign body retrieved with Roth net. Our technique averted severe trauma to esophagus. Glue (n-butyl-2-cyanoacrylate) polymerizes after contact with weak bases. It is commonly used for variceal obliteration and closure of fistulae.[1] [2] [3] This technique is a safe alternative in specific cases of sharp foreign body retrieval. Publication Date: 25 April 2022 (online) © 2022. Society of Gastrointestinal Endoscopy of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 25 October 2021
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (09) , E522-E523
A novel technique of migrated biliary stent retrieval
A 28-year-old man presented for stent removal one year after endoscopic retrograde cholangiogram and biliary stenting for anastomotic stricture after living-donor liver transplantation. On duodenoscopy, two biliary stents were visible at the papilla, and retrieval was attempted with the aid of a snare. However, only one stent could be removed completely and the second biliary stent broke off and migrated proximally. Subsequently, a guidewire was passed parallel to the migrated stent. Then a stone extraction balloon was passed over the guidewire in an attempt to retrieve the migrated stent by applying traction via the over-inflated balloon ([Fig. 1]). We could see the broken stent across the papilla upon traction. However, we could not exchange the balloon in the duodenoscope because the stent repeatedly migrated inwards once we deflated the balloon and attempted to exchange it for a snare. In this scenario, we considered a double-channel therapeutic scope (GIF-2TH180 EVIS EXERA II gastrovideoscope; Olympus, Tokyo, Japan) to retrieve the stent while simultaneously applying traction. To support insertion of the therapeutic scope, we initially placed a 5-Fr guide catheter (Boston Scientific, Marlborough, Massachusetts, USA) over the guidewire and the duodenoscope was exchanged for the therapeutic scope over the guide catheter. Once the therapeutic scope reached the papilla, the guide catheter was exchanged for a stone extraction balloon through one channel of the therapeutic scope and a snare loaded into the second channel. Then, by applying traction with the inflated balloon, the stent came across the papilla and the lower end of the stent was caught with the snare and successfully retrieved ([Video 1], [Fig. 2]). Video 1 Successful removal of a broken, proximally migrated plastic stent using a double-channel therapeutic endoscope along with a stone extraction balloon and snare in a patient with post-transplant biliary stricture. Various techniques have been described for retrieval of a migrated stent using forceps, a basket, snare, Soehendra stent retriever, cholangioscope, and balloon [1] [2] [3] [4]. To the best of our knowledge, this is the first case that highlights the use of a therapeutic scope in stent retrieval. Endoscopy_UCTN_Code_CPL_1AK_2AD Publication Date: 25 October 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 25 October 2021
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (09) , E522-E523
A novel technique of migrated biliary stent retrieval
A 28-year-old man presented for stent removal one year after endoscopic retrograde cholangiogram and biliary stenting for anastomotic stricture after living-donor liver transplantation. On duodenoscopy, two biliary stents were visible at the papilla, and retrieval was attempted with the aid of a snare. However, only one stent could be removed completely and the second biliary stent broke off and migrated proximally. Subsequently, a guidewire was passed parallel to the migrated stent. Then a stone extraction balloon was passed over the guidewire in an attempt to retrieve the migrated stent by applying traction via the over-inflated balloon ([Fig. 1]). We could see the broken stent across the papilla upon traction. However, we could not exchange the balloon in the duodenoscope because the stent repeatedly migrated inwards once we deflated the balloon and attempted to exchange it for a snare. In this scenario, we considered a double-channel therapeutic scope (GIF-2TH180 EVIS EXERA II gastrovideoscope; Olympus, Tokyo, Japan) to retrieve the stent while simultaneously applying traction. To support insertion of the therapeutic scope, we initially placed a 5-Fr guide catheter (Boston Scientific, Marlborough, Massachusetts, USA) over the guidewire and the duodenoscope was exchanged for the therapeutic scope over the guide catheter. Once the therapeutic scope reached the papilla, the guide catheter was exchanged for a stone extraction balloon through one channel of the therapeutic scope and a snare loaded into the second channel. Then, by applying traction with the inflated balloon, the stent came across the papilla and the lower end of the stent was caught with the snare and successfully retrieved ([Video 1], [Fig. 2]). Video 1 Successful removal of a broken, proximally migrated plastic stent using a double-channel therapeutic endoscope along with a stone extraction balloon and snare in a patient with post-transplant biliary stricture. Various techniques have been described for retrieval of a migrated stent using forceps, a basket, snare, Soehendra stent retriever, cholangioscope, and balloon [1] [2] [3] [4]. To the best of our knowledge, this is the first case that highlights the use of a therapeutic scope in stent retrieval. Endoscopy_UCTN_Code_CPL_1AK_2AD Publication Date: 25 October 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 22 January 2016
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 48 (S 01) , E240-E241
Endoscopic esophageal perforation extending upwards along the carotid arteries
A 21-year-old man presented to gastroenterology services with progressive dysphagia, 6 weeks after ingestion of dichlorvos (2,2-dichlorovinyl dimethyl phosphate), an organophosphate insecticide used to control household pests. Barium swallow revealed a long stricture involving the middle and lower thirds of the esophagus. The difficulties, complications, and failure rates of endoscopic dilation for long strictures were explained to the patient, and surgery was advised. However, the patient wanted a trial of endoscopic management prior to surgery. Esophagogastroduodenoscopy revealed a stricture starting at 20 cm from the incisors. It was dilated up to 10 mm with a controlled radial expansion (CRE) balloon (CRE single-use wireguided balloon dilator; Boston Scientific, Natick, Massachusetts, USA). However, the endoscope could not be negotiated beyond the stricture. A week later, a second session of endoscopic dilation was performed with an 8 – 10-mm balloon (Boston Scientific), during which the first stricture at 20 cm was dilated up to 10 mm, and the scope could be negotiated past the stricture. A second stricture starting at 24 cm was noted, and this was dilated up to 10 mm. After dilation, the scope could be passed as far as 27 cm; but further advancement was abandoned because of a circumferential ulceration seen at 27 cm. In the immediate post-procedure period, the patient complained of right-sided neck pain. On examination, mild crepitus was felt, raising suspicion of an iatrogenic esophageal perforation. Water-soluble contrast study revealed a leak in the mid esophagus. The contrast was seen to track into the neck along the right carotid sheath as far as the skull base. Later the contrast outlined the left pericardial surface ([Fig. 1], [Video 1]). Our patient was immediately taken for surgery. Intraoperatively, a 3 × 1-cm perforation was seen, 10 cm below the cricopharynx. Transhiatal esophagectomy with cervical esophagostomy was done. A feeding jejunostomy was also created. The patient was discharged after an uneventful 1-week postoperative period. The patient’s condition is being improved for definitive surgery. The carotid sheath is a condensation of cervical fascia around the common and internal carotid arteries, the vagus nerve, and the internal jugular vein, with contributions from prevertebral, pretracheal, and deep cervical fascias. The prevertebral lamina of the cervical fascia covers anterior vertebral muscles; its superior extension is attached to the base of the skull and inferiorly it extends to the superior mediastinum and blends with the anterior longitudinal ligament. The pretracheal lamina is very thin; it is attached superiorly to the arch of the cricoid cartilage, and continues below as far as the superior mediastinum, where it fuses with the pericardium [1] [2]. The esophagus and trachea are located in the space between the pretracheal and prevertebral fascia. In our patient, the leak site was at the level of the T4 vertebra ([Fig. 2]). The contrast first leaked into the middle mediastinum on the right side and later tracked up along the right carotid sheath to the base of skull, then spreading to the left pericardial surface ([Fig. 2]). Although dichlorvos is a potentially corrosive agent, to the best of our knowledge, no human case of esophageal stricture caused by dichlorvos has been reported so far in the literature. Esophageal perforation can occur in 0.1 % – 0.3 % patients during routine endoscopy [3] [4]. Neck pain is a common presentation after cervical esophageal perforation; however, it is rarely observed in cases of thoracic esophageal perforation. Also, contrast extravasation along the carotid vessels is rare; in the present case it can be explained on the basis of the fascial attachments. Endoscopy_UCTN_Code_CPL_1AH_2AG
- 22 January 2016
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 48 (S 01) , E240-E241
Endoscopic esophageal perforation extending upwards along the carotid arteries
A 21-year-old man presented to gastroenterology services with progressive dysphagia, 6 weeks after ingestion of dichlorvos (2,2-dichlorovinyl dimethyl phosphate), an organophosphate insecticide used to control household pests. Barium swallow revealed a long stricture involving the middle and lower thirds of the esophagus. The difficulties, complications, and failure rates of endoscopic dilation for long strictures were explained to the patient, and surgery was advised. However, the patient wanted a trial of endoscopic management prior to surgery. Esophagogastroduodenoscopy revealed a stricture starting at 20 cm from the incisors. It was dilated up to 10 mm with a controlled radial expansion (CRE) balloon (CRE single-use wireguided balloon dilator; Boston Scientific, Natick, Massachusetts, USA). However, the endoscope could not be negotiated beyond the stricture. A week later, a second session of endoscopic dilation was performed with an 8 – 10-mm balloon (Boston Scientific), during which the first stricture at 20 cm was dilated up to 10 mm, and the scope could be negotiated past the stricture. A second stricture starting at 24 cm was noted, and this was dilated up to 10 mm. After dilation, the scope could be passed as far as 27 cm; but further advancement was abandoned because of a circumferential ulceration seen at 27 cm. In the immediate post-procedure period, the patient complained of right-sided neck pain. On examination, mild crepitus was felt, raising suspicion of an iatrogenic esophageal perforation. Water-soluble contrast study revealed a leak in the mid esophagus. The contrast was seen to track into the neck along the right carotid sheath as far as the skull base. Later the contrast outlined the left pericardial surface ([Fig. 1], [Video 1]). Our patient was immediately taken for surgery. Intraoperatively, a 3 × 1-cm perforation was seen, 10 cm below the cricopharynx. Transhiatal esophagectomy with cervical esophagostomy was done. A feeding jejunostomy was also created. The patient was discharged after an uneventful 1-week postoperative period. The patient’s condition is being improved for definitive surgery. The carotid sheath is a condensation of cervical fascia around the common and internal carotid arteries, the vagus nerve, and the internal jugular vein, with contributions from prevertebral, pretracheal, and deep cervical fascias. The prevertebral lamina of the cervical fascia covers anterior vertebral muscles; its superior extension is attached to the base of the skull and inferiorly it extends to the superior mediastinum and blends with the anterior longitudinal ligament. The pretracheal lamina is very thin; it is attached superiorly to the arch of the cricoid cartilage, and continues below as far as the superior mediastinum, where it fuses with the pericardium [1] [2]. The esophagus and trachea are located in the space between the pretracheal and prevertebral fascia. In our patient, the leak site was at the level of the T4 vertebra ([Fig. 2]). The contrast first leaked into the middle mediastinum on the right side and later tracked up along the right carotid sheath to the base of skull, then spreading to the left pericardial surface ([Fig. 2]). Although dichlorvos is a potentially corrosive agent, to the best of our knowledge, no human case of esophageal stricture caused by dichlorvos has been reported so far in the literature. Esophageal perforation can occur in 0.1 % – 0.3 % patients during routine endoscopy [3] [4]. Neck pain is a common presentation after cervical esophageal perforation; however, it is rarely observed in cases of thoracic esophageal perforation. Also, contrast extravasation along the carotid vessels is rare; in the present case it can be explained on the basis of the fascial attachments. Endoscopy_UCTN_Code_CPL_1AH_2AG
- 1 October 2015
- Published by Wolters Kluwer Health in Tropical Gastroenterology
- Vol. 36 (4) , 270
Endoscopic biopsy
- 1 October 2015
- Published by Wolters Kluwer Health in Tropical Gastroenterology
- Vol. 36 (4) , 270
Endoscopic biopsy
- 20 January 2015
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 47 (S 01) , E339
Retrieval of migrated pancreatic stent: “stent-in-stent” technique
A 13-year-old boy, in whom a 10-Fr, 10-cm pancreatic stent had been placed 3 months earlier to manage chronic pancreatitis and pain syndrome, was admitted for stent exchange. On endoscopic retrograde cholangiopancreatography, the pancreatic stent was not visible at the papilla. The pancreatic duct was cannulated with a 0.025-inch guidewire (VisiGlide; Olympus America, Center Valley, Pennsylvania, USA). Fluoroscopy showed that the stent had migrated deeply into the pancreatic duct and that the guidewire had passed through the stent ([Fig. 1 a, b]). A novel method for stent retrieval was adopted. After ensuring that the tip of guidewire had passed through the migrated stent, we passed a 7-Fr, 7-cm stent over the guidewire and pushed it into the 10-Fr stent. After we confirmed under fluoroscopy that the 7-Fr stent had passed into the 10-Fr stent by monitoring the transmission of force through it, we removed the guidewire ([Fig. 1 c]). With the use of a foreign body forceps (Cook Medical, Bloomington, Indiana, USA) and a snare (Olympus, Tokyo, Japan), the 7-Fr/10-Fr stent “system” was withdrawn into the duodenum and finally removed ([Fig. 1 d]). Pancreatic stents can migrate distally in the pancreatic duct in up to 7.5 % of patients and proximally in 5.2 % of patients. These situations are clinically challenging, and surgical intervention may be required in 10 % to 17 % of cases [1] [2] [3]. Experienced endoscopists and dedicated devices are essential to increase the successful endoscopic retrieval of migrated stents. In practice, the availability of both is limited in many centers. Our novel technique requires only a guidewire and a pancreatic stent of smaller size, which are available in most centers. The chances of trauma to the pancreatic duct are less with this technique than with other techniques, in which an additional device must be accommodated within the pancreatic duct, increasing the likelihood of duct trauma. Endoscopy_UCTN_Code_CPL_1AK_2AD
- 20 January 2015
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 47 (S 01) , E339
Retrieval of migrated pancreatic stent: “stent-in-stent” technique
A 13-year-old boy, in whom a 10-Fr, 10-cm pancreatic stent had been placed 3 months earlier to manage chronic pancreatitis and pain syndrome, was admitted for stent exchange. On endoscopic retrograde cholangiopancreatography, the pancreatic stent was not visible at the papilla. The pancreatic duct was cannulated with a 0.025-inch guidewire (VisiGlide; Olympus America, Center Valley, Pennsylvania, USA). Fluoroscopy showed that the stent had migrated deeply into the pancreatic duct and that the guidewire had passed through the stent ([Fig. 1 a, b]). A novel method for stent retrieval was adopted. After ensuring that the tip of guidewire had passed through the migrated stent, we passed a 7-Fr, 7-cm stent over the guidewire and pushed it into the 10-Fr stent. After we confirmed under fluoroscopy that the 7-Fr stent had passed into the 10-Fr stent by monitoring the transmission of force through it, we removed the guidewire ([Fig. 1 c]). With the use of a foreign body forceps (Cook Medical, Bloomington, Indiana, USA) and a snare (Olympus, Tokyo, Japan), the 7-Fr/10-Fr stent “system” was withdrawn into the duodenum and finally removed ([Fig. 1 d]). Pancreatic stents can migrate distally in the pancreatic duct in up to 7.5 % of patients and proximally in 5.2 % of patients. These situations are clinically challenging, and surgical intervention may be required in 10 % to 17 % of cases [1] [2] [3]. Experienced endoscopists and dedicated devices are essential to increase the successful endoscopic retrieval of migrated stents. In practice, the availability of both is limited in many centers. Our novel technique requires only a guidewire and a pancreatic stent of smaller size, which are available in most centers. The chances of trauma to the pancreatic duct are less with this technique than with other techniques, in which an additional device must be accommodated within the pancreatic duct, increasing the likelihood of duct trauma. Endoscopy_UCTN_Code_CPL_1AK_2AD