Catharine I. Paules
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Catharine I. Paules has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Alexander G. Hajduczok
Department of Cardiology, Oklahoma Heart Institute, Tulsa (A.H.).
2 shared publications - Andrew Tinsley
Department of Medicine, Division of Gastroenterology and Hepatology, Pennsylvania State University College of Medicine, Hershey, USA
2 shared publications - Audrey K Thorp
Division of Internal Medicine, Department of Medicine, Penn State Health Milton S. Hershey Medical Center, Hershey, PA, United States
2 shared publications - Brinnae Bent
Duke University
2 shared publications - Cameron R. Wolfe
Division of Infectious Diseases Duke University Medical Center Durham North Carolina USA
2 shared publications - David Chien Lye
National Centre for Infectious Diseases, Singapore, Singapore
2 shared publications
Latest Publications
- 1 March 2024
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 177 (3) , 343-352
A Risk Profile Using Simple Hematologic Parameters to Assess Benefits From Baricitinib in Patients Hospitalized With COVID-19: A Post Hoc Analysis of the Adaptive COVID-19 Treatment Trial-2
The ACTT risk profile, which was developed from ACTT-1 (Adaptive COVID-19 Treatment Trial-1), demonstrated that hospitalized patients with COVID-19 in the high-risk quartile (characterized by low absolute lymphocyte count [ALC], high absolute neutrophil count [ANC], and low platelet count at baseline) benefited most from treatment with the antiviral remdesivir. It is unknown which patient characteristics are associated with benefit from treatment with the immunomodulator baricitinib. To apply the ACTT risk profile to the ACTT-2 cohort to investigate potential baricitinib-related treatment effects by risk quartile. Post hoc analysis of ACTT-2, a randomized, double-blind, placebo-controlled trial. (ClinicalTrials.gov: NCT04401579). Sixty-seven trial sites in 8 countries. Adults hospitalized with COVID-19 (n = 999; 85% U.S. participants). Baricitinib+remdesivir versus placebo+remdesivir. Mortality, progression to invasive mechanical ventilation (IMV) or death, and recovery, all within 28 days; ALC, ANC, and platelet count trajectories. In the high-risk quartile, baricitinib+remdesivir was associated with reduced risk for death (hazard ratio [HR], 0.38 [95% CI, 0.16 to 0.86]; P = 0.020), decreased progression to IMV or death (HR, 0.57 [CI, 0.35 to 0.93]; P = 0.024), and improved recovery rate (HR, 1.53 [CI, 1.16 to 2.02]; P = 0.002) compared with placebo+remdesivir. After 5 days, participants receiving baricitinib+remdesivir had significantly larger increases in ALC and significantly larger decreases in ANC compared with control participants, with the largest effects observed in the high-risk quartile. Secondary analysis of data collected before circulation of current SARS-CoV-2 variants. The ACTT risk profile identifies a subgroup of hospitalized patients who benefit most from baricitinib treatment and captures a patient phenotype of treatment response to an immunomodulator and an antiviral. Changes in ALC and ANC trajectory suggest a mechanism whereby an immunomodulator limits severe COVID-19. National Institute of Allergy and Infectious Diseases.
- 1 March 2024
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 177 (3) , 343-352
A Risk Profile Using Simple Hematologic Parameters to Assess Benefits From Baricitinib in Patients Hospitalized With COVID-19: A Post Hoc Analysis of the Adaptive COVID-19 Treatment Trial-2
The ACTT risk profile, which was developed from ACTT-1 (Adaptive COVID-19 Treatment Trial-1), demonstrated that hospitalized patients with COVID-19 in the high-risk quartile (characterized by low absolute lymphocyte count [ALC], high absolute neutrophil count [ANC], and low platelet count at baseline) benefited most from treatment with the antiviral remdesivir. It is unknown which patient characteristics are associated with benefit from treatment with the immunomodulator baricitinib. To apply the ACTT risk profile to the ACTT-2 cohort to investigate potential baricitinib-related treatment effects by risk quartile. Post hoc analysis of ACTT-2, a randomized, double-blind, placebo-controlled trial. (ClinicalTrials.gov: NCT04401579). Sixty-seven trial sites in 8 countries. Adults hospitalized with COVID-19 (n = 999; 85% U.S. participants). Baricitinib+remdesivir versus placebo+remdesivir. Mortality, progression to invasive mechanical ventilation (IMV) or death, and recovery, all within 28 days; ALC, ANC, and platelet count trajectories. In the high-risk quartile, baricitinib+remdesivir was associated with reduced risk for death (hazard ratio [HR], 0.38 [95% CI, 0.16 to 0.86]; P = 0.020), decreased progression to IMV or death (HR, 0.57 [CI, 0.35 to 0.93]; P = 0.024), and improved recovery rate (HR, 1.53 [CI, 1.16 to 2.02]; P = 0.002) compared with placebo+remdesivir. After 5 days, participants receiving baricitinib+remdesivir had significantly larger increases in ALC and significantly larger decreases in ANC compared with control participants, with the largest effects observed in the high-risk quartile. Secondary analysis of data collected before circulation of current SARS-CoV-2 variants. The ACTT risk profile identifies a subgroup of hospitalized patients who benefit most from baricitinib treatment and captures a patient phenotype of treatment response to an immunomodulator and an antiviral. Changes in ALC and ANC trajectory suggest a mechanism whereby an immunomodulator limits severe COVID-19. National Institute of Allergy and Infectious Diseases.
- Open Access
- 27 November 2023
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 10 (Supplement)
1339. Effects of Tixagevimab-Cilgavimab in Clinical Practice is Consistent with Preliminary Neutralization Studies
Emergency use of tixagevimab-cilgavimab was based on data collected prior to the emergence of SARS-CoV-2 omicron variant and subvariants. Dosing recommendations changed twice based on neutralization data alone, leading to patients receiving different doses at varying intervals. We provide real-world data on efficacy of tixagevimab-cilgavimab in immunocompromised patients throughout 2022, including the incidence and timing of infection based on dosing scheme. Charts of 471 patients who received and 126 patients who declined administration of tixagevimab-cilgavimab were analyzed through December 14th, 2022. We evaluated incidence of SARS-CoV2, severity, risk factors and vaccination status. For analysis, we grouped patients with similar dosing: Group A received one initial dose of 150mg/150mg of tixagevimab-cilgavimab, Group B received at least 300 mg/300 mg of tixagevimab-cilgavimab before July 1st, and Group C patients were up to date with the FDA dosing guidelines. Number of SARS-CoV-2 infections per month based on dosing regimen Group A patients received one initial dose of 150 mg/150mg of tixagevimab-cilgavimab. Group B patients received at least 300 mg/300 mg of tixagevimab-cilgavimab before July 1st, 2022 . Group C patients were up to date with the FDA dosing guidelines. The tixagevimab-cilgavimab group demonstrated increased incidence of SARS-CoV-2. This may reflect increased healthcare system utilization, as most infections were self-reported in this study. Those with the FDA recommended dose were most likely to develop SARS-CoV-2 in November and December 2022 when circulating variants were not neutralized by tixagevimab-cilgavimab in vitro. This suggests in vitro neutralization data correlates with clinical efficacy. All Authors: No reported disclosures
- 27 November 2023
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 10 (Supplement)
Open Access1339. Effects of Tixagevimab-Cilgavimab in Clinical Practice is Consistent with Preliminary Neutralization Studies
Emergency use of tixagevimab-cilgavimab was based on data collected prior to the emergence of SARS-CoV-2 omicron variant and subvariants. Dosing recommendations changed twice based on neutralization data alone, leading to patients receiving different doses at varying intervals. We provide real-world data on efficacy of tixagevimab-cilgavimab in immunocompromised patients throughout 2022, including the incidence and timing of infection based on dosing scheme. Charts of 471 patients who received and 126 patients who declined administration of tixagevimab-cilgavimab were analyzed through December 14th, 2022. We evaluated incidence of SARS-CoV2, severity, risk factors and vaccination status. For analysis, we grouped patients with similar dosing: Group A received one initial dose of 150mg/150mg of tixagevimab-cilgavimab, Group B received at least 300 mg/300 mg of tixagevimab-cilgavimab before July 1st, and Group C patients were up to date with the FDA dosing guidelines. Number of SARS-CoV-2 infections per month based on dosing regimen Group A patients received one initial dose of 150 mg/150mg of tixagevimab-cilgavimab. Group B patients received at least 300 mg/300 mg of tixagevimab-cilgavimab before July 1st, 2022 . Group C patients were up to date with the FDA dosing guidelines. The tixagevimab-cilgavimab group demonstrated increased incidence of SARS-CoV-2. This may reflect increased healthcare system utilization, as most infections were self-reported in this study. Those with the FDA recommended dose were most likely to develop SARS-CoV-2 in November and December 2022 when circulating variants were not neutralized by tixagevimab-cilgavimab in vitro. This suggests in vitro neutralization data correlates with clinical efficacy. All Authors: No reported disclosures
- 29 November 2022
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 175 (12) , 1716-1727
Temporal Improvements in COVID-19 Outcomes for Hospitalized Adults: A Post Hoc Observational Study of Remdesivir Group Participants in the Adaptive COVID-19 Treatment Trial
The standard of care (SOC) for COVID-19 evolved rapidly during 2020 and 2021, but its cumulative effect over time is unclear. In this post hoc analysis of a series of phase 3 trials that evaluated ... Visual Temporal Improvements in COVID-19 Outcomes for Hospitalized Adults. The standard of care (SOC) for COVID-19 evolved rapidly during 2020 and 2021, but its cumulative effect over time... Background: The COVID-19 standard of care (SOC) evolved rapidly during 2020 and 2021, but its cumulative effect over time is unclear. Objective: To evaluate whether recovery and mortality improved ...
- 29 November 2022
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 175 (12) , 1716-1727
Temporal Improvements in COVID-19 Outcomes for Hospitalized Adults: A Post Hoc Observational Study of Remdesivir Group Participants in the Adaptive COVID-19 Treatment Trial
The standard of care (SOC) for COVID-19 evolved rapidly during 2020 and 2021, but its cumulative effect over time is unclear. In this post hoc analysis of a series of phase 3 trials that evaluated ... Visual Temporal Improvements in COVID-19 Outcomes for Hospitalized Adults. The standard of care (SOC) for COVID-19 evolved rapidly during 2020 and 2021, but its cumulative effect over time... Background: The COVID-19 standard of care (SOC) evolved rapidly during 2020 and 2021, but its cumulative effect over time is unclear. Objective: To evaluate whether recovery and mortality improved ...
- Open Access
- 4 August 2021
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 5 (8) , e28568
Physiologic Response to the Pfizer-BioNTech COVID-19 Vaccine Measured Using Wearable Devices: Prospective Observational Study
Background: The Pfizer-BioNTech COVID-19 vaccine uses a novel messenger RNA technology to elicit a protective immune response. Short-term physiologic responses to the vaccine have not been studied using wearable devices. Objective: We aim to characterize physiologic changes in response to COVID-19 vaccination in a small cohort of participants using a wearable device (WHOOP Strap 3.0). This is a proof of concept for using consumer-grade wearable devices to monitor response to COVID-19 vaccines. Methods: In this prospective observational study, physiologic data from 19 internal medicine residents at a single institution that received both doses of the Pfizer-BioNTech COVID-19 vaccine was collected using the WHOOP Strap 3.0. The primary outcomes were percent change from baseline in heart rate variability (HRV), resting heart rate (RHR), and respiratory rate (RR). Secondary outcomes were percent change from baseline in total, rapid eye movement, and deep sleep. Exploratory outcomes included local and systemic reactogenicity following each dose and prophylactic analgesic use. Results: In 19 individuals (mean age 28.8, SD 2.2 years; n=10, 53% female), HRV was decreased on day 1 following administration of the first vaccine dose (mean –13.44%, SD 13.62%) and second vaccine dose (mean –9.25%, SD 22.6%). RHR and RR showed no change from baseline after either vaccine dose. Sleep duration was increased up to 4 days post vaccination, after an initial decrease on day 1. Increased sleep duration prior to vaccination was associated with a greater change in HRV. Local and systemic reactogenicity was more severe after dose two. Conclusions: This is the first observational study of the physiologic response to any of the novel COVID-19 vaccines as measured using wearable devices. Using this relatively small healthy cohort, we provide evidence that HRV decreases in response to both vaccine doses, with no significant changes in RHR or RR. Sleep duration initially decreased following each dose with a subsequent increase thereafter. Future studies with a larger sample size and comparison to other inflammatory and immune biomarkers such as antibody response will be needed to determine the true utility of this type of continuous wearable monitoring in regards to vaccine responses. Our data raises the possibility that increased sleep prior to vaccination may impact physiologic responses and may be a modifiable way to increase vaccine response. These results may inform future studies using wearables for monitoring vaccine responses. Trial Registration: ClinicalTrials.gov NCT04304703; https://www.clinicaltrials.gov/ct2/show/NCT04304703
- 4 August 2021
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 5 (8) , e28568
Open AccessPhysiologic Response to the Pfizer-BioNTech COVID-19 Vaccine Measured Using Wearable Devices: Prospective Observational Study
Background: The Pfizer-BioNTech COVID-19 vaccine uses a novel messenger RNA technology to elicit a protective immune response. Short-term physiologic responses to the vaccine have not been studied using wearable devices. Objective: We aim to characterize physiologic changes in response to COVID-19 vaccination in a small cohort of participants using a wearable device (WHOOP Strap 3.0). This is a proof of concept for using consumer-grade wearable devices to monitor response to COVID-19 vaccines. Methods: In this prospective observational study, physiologic data from 19 internal medicine residents at a single institution that received both doses of the Pfizer-BioNTech COVID-19 vaccine was collected using the WHOOP Strap 3.0. The primary outcomes were percent change from baseline in heart rate variability (HRV), resting heart rate (RHR), and respiratory rate (RR). Secondary outcomes were percent change from baseline in total, rapid eye movement, and deep sleep. Exploratory outcomes included local and systemic reactogenicity following each dose and prophylactic analgesic use. Results: In 19 individuals (mean age 28.8, SD 2.2 years; n=10, 53% female), HRV was decreased on day 1 following administration of the first vaccine dose (mean –13.44%, SD 13.62%) and second vaccine dose (mean –9.25%, SD 22.6%). RHR and RR showed no change from baseline after either vaccine dose. Sleep duration was increased up to 4 days post vaccination, after an initial decrease on day 1. Increased sleep duration prior to vaccination was associated with a greater change in HRV. Local and systemic reactogenicity was more severe after dose two. Conclusions: This is the first observational study of the physiologic response to any of the novel COVID-19 vaccines as measured using wearable devices. Using this relatively small healthy cohort, we provide evidence that HRV decreases in response to both vaccine doses, with no significant changes in RHR or RR. Sleep duration initially decreased following each dose with a subsequent increase thereafter. Future studies with a larger sample size and comparison to other inflammatory and immune biomarkers such as antibody response will be needed to determine the true utility of this type of continuous wearable monitoring in regards to vaccine responses. Our data raises the possibility that increased sleep prior to vaccination may impact physiologic responses and may be a modifiable way to increase vaccine response. These results may inform future studies using wearables for monitoring vaccine responses. Trial Registration: ClinicalTrials.gov NCT04304703; https://www.clinicaltrials.gov/ct2/show/NCT04304703
- Open Access
- 13 March 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Physiologic Response to the Pfizer-BioNTech COVID-19 Vaccine Measured Using Wearable Devices: Prospective Observational Study (Preprint)
BACKGROUND The Pfizer-BioNTech COVID-19 vaccine uses a novel messenger RNA technology to elicit a protective immune response. Short-term physiologic responses to the vaccine have not been studied using wearable devices. OBJECTIVE We aim to characterize physiologic changes in response to COVID-19 vaccination in a small cohort of participants using a wearable device (WHOOP Strap 3.0). This is a proof of concept for using consumer-grade wearable devices to monitor response to COVID-19 vaccines. METHODS In this prospective observational study, physiologic data from 19 internal medicine residents at a single institution that received both doses of the Pfizer-BioNTech COVID-19 vaccine was collected using the WHOOP Strap 3.0. The primary outcomes were percent change from baseline in heart rate variability (HRV), resting heart rate (RHR), and respiratory rate (RR). Secondary outcomes were percent change from baseline in total, rapid eye movement, and deep sleep. Exploratory outcomes included local and systemic reactogenicity following each dose and prophylactic analgesic use. RESULTS In 19 individuals (mean age 28.8, SD 2.2 years; n=10, 53% female), HRV was decreased on day 1 following administration of the first vaccine dose (mean –13.44%, SD 13.62%) and second vaccine dose (mean –9.25%, SD 22.6%). RHR and RR showed no change from baseline after either vaccine dose. Sleep duration was increased up to 4 days post vaccination, after an initial decrease on day 1. Increased sleep duration prior to vaccination was associated with a greater change in HRV. Local and systemic reactogenicity was more severe after dose two. CONCLUSIONS This is the first observational study of the physiologic response to any of the novel COVID-19 vaccines as measured using wearable devices. Using this relatively small healthy cohort, we provide evidence that HRV decreases in response to both vaccine doses, with no significant changes in RHR or RR. Sleep duration initially decreased following each dose with a subsequent increase thereafter. Future studies with a larger sample size and comparison to other inflammatory and immune biomarkers such as antibody response will be needed to determine the true utility of this type of continuous wearable monitoring in regards to vaccine responses. Our data raises the possibility that increased sleep prior to vaccination may impact physiologic responses and may be a modifiable way to increase vaccine response. These results may inform future studies using wearables for monitoring vaccine responses. CLINICALTRIAL ClinicalTrials.gov NCT04304703; https://www.clinicaltrials.gov/ct2/show/NCT04304703
- 13 March 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessPhysiologic Response to the Pfizer-BioNTech COVID-19 Vaccine Measured Using Wearable Devices: Prospective Observational Study (Preprint)
BACKGROUND The Pfizer-BioNTech COVID-19 vaccine uses a novel messenger RNA technology to elicit a protective immune response. Short-term physiologic responses to the vaccine have not been studied using wearable devices. OBJECTIVE We aim to characterize physiologic changes in response to COVID-19 vaccination in a small cohort of participants using a wearable device (WHOOP Strap 3.0). This is a proof of concept for using consumer-grade wearable devices to monitor response to COVID-19 vaccines. METHODS In this prospective observational study, physiologic data from 19 internal medicine residents at a single institution that received both doses of the Pfizer-BioNTech COVID-19 vaccine was collected using the WHOOP Strap 3.0. The primary outcomes were percent change from baseline in heart rate variability (HRV), resting heart rate (RHR), and respiratory rate (RR). Secondary outcomes were percent change from baseline in total, rapid eye movement, and deep sleep. Exploratory outcomes included local and systemic reactogenicity following each dose and prophylactic analgesic use. RESULTS In 19 individuals (mean age 28.8, SD 2.2 years; n=10, 53% female), HRV was decreased on day 1 following administration of the first vaccine dose (mean –13.44%, SD 13.62%) and second vaccine dose (mean –9.25%, SD 22.6%). RHR and RR showed no change from baseline after either vaccine dose. Sleep duration was increased up to 4 days post vaccination, after an initial decrease on day 1. Increased sleep duration prior to vaccination was associated with a greater change in HRV. Local and systemic reactogenicity was more severe after dose two. CONCLUSIONS This is the first observational study of the physiologic response to any of the novel COVID-19 vaccines as measured using wearable devices. Using this relatively small healthy cohort, we provide evidence that HRV decreases in response to both vaccine doses, with no significant changes in RHR or RR. Sleep duration initially decreased following each dose with a subsequent increase thereafter. Future studies with a larger sample size and comparison to other inflammatory and immune biomarkers such as antibody response will be needed to determine the true utility of this type of continuous wearable monitoring in regards to vaccine responses. Our data raises the possibility that increased sleep prior to vaccination may impact physiologic responses and may be a modifiable way to increase vaccine response. These results may inform future studies using wearables for monitoring vaccine responses. CLINICALTRIAL ClinicalTrials.gov NCT04304703; https://www.clinicaltrials.gov/ct2/show/NCT04304703