CFColin P. Froines

Colin P. Froines

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Colin P. Froines has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • METALLIC RETINAL ARTERY EMBOLUS AFTER PIPELINE EMBOLIZATION DEVICE

    by Colin P. Froines, Samuel A. Whittier, Justin L. Gottlieb

    Purpose: To describe a case of asymptomatic metallic retinal embolus after stent-in-stent pipeline embolization device placement. Methods: Case report of a 41-year-old woman with left ophthalmic artery aneurysm treated twice with pipeline embolization device referred to ophthalmology for incidentally found refractile object in left eye macula. Results: Clinical findings notable for fundoscopic examination with refractile foreign body at the temporal edge of fovea. Object was observed to be intravascular on optical coherence tomography and without vascular occlusion on optical coherence tomography angiography. Conclusion: Metallic embolus seems to be a rare complication of pipeline embolization device placement.

  • SCLEROCHOROIDAL CALCIFICATION PRESENTING WITH UNILATERAL FULL-THICKNESS MACULAR HOLE: PRESENTATION AND SUCCESSFUL SURGICAL CLOSURE

    by Alyssa C. Bs Huelsbeck, Colin P. Froines, Kathleen R. Schildroth

    Purpose: Describe a case of macular hole (MH) presenting in a patient with sclerochoroidal calcification (SCC). Only one previous case of an MH in the setting of SCC has previously been reported; however, that case was observed without surgery. We present a case of an MH in SCC in which successful surgical closure and visual acuity improvement were achieved. Methods: Case report. Results: A 70-year-old man presented for retinal evaluation of metamorphopsia with a visual acuity of 20/25 in the right eye and 20/300 in the left eye. Fundoscopic examination showed bilateral SCC. Ultrasonographic B-scan examination of the left eye was consistent with SCC. An optical coherence tomography showed a full thickness MH in the left eye, and surgical repair with pars plana vitrectomy, internal limiting membrane peel, and gas was performed. Postoperatively, the visual acuity in the left eye was 20/50; the examination and optical coherence tomography showed anatomic success with closure of the MH and stable SCC lesions. Conclusion: SCC may be associated with full thickness MH, possibly secondary to tangential traction from the elevated lesion. Despite the SCC lesion, successful MH closure may be achieved with typical maneuvers of vitrectomy, internal limiting membrane peel, and gas.

  • Open Access

    Comparison of Clarus, Optos, and Heidelberg Systems for Geographic Atrophy Area Measurements

    by Jacob Bogost, Thomas Saunders, Jennifer Heathcote, Jeong W. Pak, David Lopez, Colin Froines, Barbara Blodi, Roomasa Channa, Kathleen Schildroth, Kevin Kurt, et al.

  • Open Access

    Presumed Secondary Vitreoretinal Lymphoma with Response to Systemic Therapy Alone: Case Report

    by Alyssa C. Huelsbeck, Colin P. Froines, Julie E. Chang, Gordon S. Crabtree

    Introduction: Intraocular lymphoma is a rare malignancy with no standard treatment regimen. We describe a case of secondary vitreoretinal lymphoma (VRL) with excellent response to systemic chemotherapy alone without intravitreal treatment. Case Presentation: A 72-year-old male with a diagnosis of stage IVA diffuse large B-cell lymphoma presented for evaluation of subretinal involvement with visual acuity of 20/20-3 in the right eye and 20/100 in the left eye. Fundus examination was largely unremarkable. Fundus autofluorescence (FAF) showed hyperautofluorescence in the macula with an area of hypoautofluorescence that could not be detected on examination. Ocular coherence tomography showed subretinal material in the macula. A biopsy was deferred, and the treatment plan involved observation of response to systemic chemotherapy. Six-month follow-up showed resolution of the subretinal material and near resolution of the hyperautofluorescence, consistent with response to treatment. Conclusion: Select cases of isolated secondary VRL may be appropriate for management with systemic chemotherapy alone. Multimodal imaging including FAF can demonstrate lesions that may be less apparent clinically. Imaging may also be used for characterization of lesions when biopsy is deferred.

  • Longitudinal Assessment of Age-Related Macular Degeneration Using Ultrawidefield Imaging

    by Colin P. Froines, Jeong W. Pak, Elvira Agrón, Emily Y. Chew, Tunde Peto, Barbara A. Blodi, Amitha Domalpally


  • Threading the Needle: A Case of Periorbital Gold Threading

    by Colin P. B.A. Froines, Erin E. Godbout, Jennifer T. M.D. Yu, Lawrence D. Tang, G. Nina Lu, Christopher B. Chambers, Matthew M. Zhang

    While a rare periorbital finding, the aesthetic practice of gold threading is increasingly identified in Western care setting and may be misidentified as the practice of inserting charm needles (susuk). The authors present a unique case of gold threading discovered incidentally during workup of chronic sinusitis and report a rarely seen delayed local site reaction. The practice of gold threading and mimickers including the practice of inserting charm needles (susuk) are reviewed with emphasis on clinical and radiographic differentiation by oculoplastic surgeons.

  • Open Access

    Comparing Telephone Survey Responses to Best-Corrected Visual Acuity to Estimate the Accuracy of Identifying Vision Loss: Validation Study

    by John Wittenborn, Aaron Lee, Elizabeth A Lundeen, Phoebe Lamuda, Jinan Saaddine, Grace L Su, Randy Lu, Aashka Damani, Jonathan S Zawadzki, Colin P Froines, et al.

    Background: Self-reported questions on blindness and vision problems are collected in many national surveys. Recently released surveillance estimates on the prevalence of vision loss used self-reported data to predict variation in the prevalence of objectively measured acuity loss among population groups for whom examination data are not available. However, the validity of self-reported measures to predict prevalence and disparities in visual acuity has not been established. Objective: This study aimed to estimate the diagnostic accuracy of self-reported vision loss measures compared to best-corrected visual acuity (BCVA), inform the design and selection of questions for future data collection, and identify the concordance between self-reported vision and measured acuity at the population level to support ongoing surveillance efforts. Methods: We calculated accuracy and correlation between self-reported visual function versus BCVA at the individual and population level among patients from the University of Washington ophthalmology or optometry clinics with a prior eye examination, randomly oversampled for visual acuity loss or diagnosed eye diseases. Self-reported visual function was collected via telephone survey. BCVA was determined based on retrospective chart review. Diagnostic accuracy of questions at the person level was measured based on the area under the receiver operator curve (AUC), whereas population-level accuracy was determined based on correlation. Results: The survey question, “Are you blind or do you have serious difficulty seeing, even when wearing glasses?” had the highest accuracy for identifying patients with blindness (BCVA ≤20/200; AUC=0.797). The highest accuracy for detecting any vision loss (BCVA <20/40) was achieved by responses of “fair,” “poor,” or “very poor” to the question, “At the present time, would you say your eyesight, with glasses or contact lenses if you wear them, is excellent, good, fair, poor, or very poor” (AUC=0.716). At the population level, the relative relationship between prevalence based on survey questions and BCVA remained stable for most demographic groups, with the only exceptions being groups with small sample sizes, and these differences were generally not significant. Conclusions: Although survey questions are not considered to be sufficiently accurate to be used as a diagnostic test at the individual level, we did find relatively high levels of accuracy for some questions. At the population level, we found that the relative prevalence of the 2 most accurate survey questions were highly correlated with the prevalence of measured visual acuity loss among nearly all demographic groups. The results of this study suggest that self-reported vision questions fielded in national surveys are likely to yield an accurate and stable signal of vision loss across different population groups, although the actual measure of prevalence from these questions is not directly analogous to that of BCVA.


  • Open Access

    Comparing Telephone Survey Responses to Best-Corrected Visual Acuity to Estimate the Accuracy of Identifying Vision Loss: Validation Study (Preprint)

    by John Wittenborn, Aaron Lee, Elizabeth A Lundeen, Phoebe Lamuda, Jinan Saaddine, Grace L Su, Randy Lu, Aashka Damani, Jonathan S Zawadzki, Colin P Froines, et al.

    BACKGROUND Self-reported questions on blindness and vision problems are collected in many national surveys. Recently released surveillance estimates on the prevalence of vision loss used self-reported data to predict variation in the prevalence of objectively measured acuity loss among population groups for whom examination data are not available. However, the validity of self-reported measures to predict prevalence and disparities in visual acuity has not been established. OBJECTIVE This study aimed to estimate the diagnostic accuracy of self-reported vision loss measures compared to best-corrected visual acuity (BCVA), inform the design and selection of questions for future data collection, and identify the concordance between self-reported vision and measured acuity at the population level to support ongoing surveillance efforts. METHODS We calculated accuracy and correlation between self-reported visual function versus BCVA at the individual and population level among patients from the University of Washington ophthalmology or optometry clinics with a prior eye examination, randomly oversampled for visual acuity loss or diagnosed eye diseases. Self-reported visual function was collected via telephone survey. BCVA was determined based on retrospective chart review. Diagnostic accuracy of questions at the person level was measured based on the area under the receiver operator curve (AUC), whereas population-level accuracy was determined based on correlation. RESULTS The survey question, “Are you blind or do you have serious difficulty seeing, even when wearing glasses?” had the highest accuracy for identifying patients with blindness (BCVA ≤20/200; AUC=0.797). The highest accuracy for detecting any vision loss (BCVA <20/40) was achieved by responses of “fair,” “poor,” or “very poor” to the question, “At the present time, would you say your eyesight, with glasses or contact lenses if you wear them, is excellent, good, fair, poor, or very poor” (AUC=0.716). At the population level, the relative relationship between prevalence based on survey questions and BCVA remained stable for most demographic groups, with the only exceptions being groups with small sample sizes, and these differences were generally not significant. CONCLUSIONS Although survey questions are not considered to be sufficiently accurate to be used as a diagnostic test at the individual level, we did find relatively high levels of accuracy for some questions. At the population level, we found that the relative prevalence of the 2 most accurate survey questions were highly correlated with the prevalence of measured visual acuity loss among nearly all demographic groups. The results of this study suggest that self-reported vision questions fielded in national surveys are likely to yield an accurate and stable signal of vision loss across different population groups, although the actual measure of prevalence from these questions is not directly analogous to that of BCVA.

  • Breaking the mold: a case of recalcitrant eyelid subconjunctival infection by Exophiala Phaeomuriformis

    by Colin P. Froines, Nathe Connor, Emily Li, Rebecca A. Yoda, Luis F. Gonzalez-Cuyar, G. Nina Lu, Roxana Fu, Matthew Zhang

    While a rare ophthalmic pathogen, infections from Exophilia spp. are increasingly identified and have been associated with catastrophic vision loss. In this case report we present a previously undescribed manifestation of the melanin-producing fungus Exophilia Phaeomuriformis to the lower eyelid, establish an effective treatment, and review related cases. Previous cases of ophthalmic E. Phaeomuriformis were confined to the cornea and included iatrogenic tissue trauma. This case shares neither associations however includes a remote SJS history that likely led to changes in conjunctival tissue integrity. Previous cases of Exophilia spp. infecting the eyelid both included surgical source control and adjuvant antibiotic. In this case, topical therapy was deferred due to SJS-related ocular cicatricial disease. Fortunately, a full resolution was achieved with surgical resection and oral antifungal treatment.