Abigail Wade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abigail Wade has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Robert Beadling
School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds LS2 9JT, UK
1 shared publication Ar Beadling
School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
1 shared publication- Danielle de Villiers
MatOrtho®, Mole Business Park, Randalls Rd, Surrey KT22 7BA, UK
1 shared publication - Dominic Jones
University of Leeds
1 shared publication F Webster
School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, UK
1 shared publication- Jo Cullum
MatOrtho®, Mole Business Park, Randalls Rd, Surrey KT22 7BA, UK
1 shared publication
Latest Publications
- Open Access
How Angular Mismatch and Surface Topography in Modular Head–Stem Taper Junctions in Total Hip Replacements Affects Fretting-Corrosion and Motion Under Uni-Axial Loading
Morse-type tapers at the head–stem junction in total hip replacements (THRs) provide many benefits to permit a successful surgical outcome. However, with the introduction of modular tapered devices comes complications associated with fluid ingress and motion at the interface that can cause fretting corrosion, which has been implicated in clinical failure. Increased surface roughness amplitude (Ra) and angular mismatch to ensure taper contact closer to the equator of the femoral head are design features introduced for use with ceramic heads but have been adopted by metal head couples. While increased surface roughness amplitude has been found to contribute to fretting corrosion, there is a distinct lack of systematic studies investigating the interactions between angular mismatch and Ra. This study measured the fretting corrosion and motion response of clinically representative samples, in part reference to ASTM F1875, when subjected to uniaxial incremental dynamic loading. The fretting corrosion response was measured in situ with an integrated three electrode electrochemical cell. Motion at the head–neck interface was measured with a bespoke motion measurement solution based on eddy-current principles which uses four sensors to allow motion to be fully characterised in three dimensions. Key findings from this study included a 5–10-fold increase in current measured in the increased roughness amplitude samples, suggesting an increased susceptibility to fretting corrosion without a corresponding increase in motion. The distal samples engaged around the opening of the taper interface and presented the lowest current measurements but most off-axis subsidence. Findings from this study indicate that optimisation of the taper interfaces in THR, in terms of fretting corrosion and motion, can be made and can be assessed using short-term preclinical tests.
Open AccessHow Angular Mismatch and Surface Topography in Modular Head–Stem Taper Junctions in Total Hip Replacements Affects Fretting-Corrosion and Motion Under Uni-Axial Loading
Morse-type tapers at the head–stem junction in total hip replacements (THRs) provide many benefits to permit a successful surgical outcome. However, with the introduction of modular tapered devices comes complications associated with fluid ingress and motion at the interface that can cause fretting corrosion, which has been implicated in clinical failure. Increased surface roughness amplitude (Ra) and angular mismatch to ensure taper contact closer to the equator of the femoral head are design features introduced for use with ceramic heads but have been adopted by metal head couples. While increased surface roughness amplitude has been found to contribute to fretting corrosion, there is a distinct lack of systematic studies investigating the interactions between angular mismatch and Ra. This study measured the fretting corrosion and motion response of clinically representative samples, in part reference to ASTM F1875, when subjected to uniaxial incremental dynamic loading. The fretting corrosion response was measured in situ with an integrated three electrode electrochemical cell. Motion at the head–neck interface was measured with a bespoke motion measurement solution based on eddy-current principles which uses four sensors to allow motion to be fully characterised in three dimensions. Key findings from this study included a 5–10-fold increase in current measured in the increased roughness amplitude samples, suggesting an increased susceptibility to fretting corrosion without a corresponding increase in motion. The distal samples engaged around the opening of the taper interface and presented the lowest current measurements but most off-axis subsidence. Findings from this study indicate that optimisation of the taper interfaces in THR, in terms of fretting corrosion and motion, can be made and can be assessed using short-term preclinical tests.
- Open Access
- 25 October 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (2) , 158-168
Importance of surgical assembly technique on the engagement of 12/14 modular tapers
Fretting-corrosion at the modular taper junction in total hip replacements (THR), leading to implant failure, has been identified as a clinical concern and has received increased interest in recent years. There are many parameters thought to affect the performance of the taper junction, with the assembly process being one of the few consistently identified to have a direct impact. Despite this, the assembly process used by surgeons during THR surgery differs from a suggested ‘ideal’ process. For example, taper junctions of cutting tools should be pushed together rather than impacted, while ensuring as much concentricity as possible between the male and female taper and loading axis. This study devised six simple assembly methodologies to investigate how surgical variations affect the success of the compressive fit achieved at the taper interface compared to a controlled assembly method, designed to represent a more ‘ideal’ scenario. Key findings from this study suggest that a more successful and repeatable engagement can be achieved by quasi-statically loading the male and female taper concentrically with the loading axis. This was shown by a greater disassembly to assembly force ratio of 0.626 ± 0.07 when assembled using the more ‘ideal’ process, compared to 0.480 ± 0.05 when using a method closer to that used by a surgeon intraoperatively. Findings from this study can be used to help inform new surgical instrumentation and an improved surgical assembly method.
- 25 October 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (2) , 158-168
Open AccessImportance of surgical assembly technique on the engagement of 12/14 modular tapers
Fretting-corrosion at the modular taper junction in total hip replacements (THR), leading to implant failure, has been identified as a clinical concern and has received increased interest in recent years. There are many parameters thought to affect the performance of the taper junction, with the assembly process being one of the few consistently identified to have a direct impact. Despite this, the assembly process used by surgeons during THR surgery differs from a suggested ‘ideal’ process. For example, taper junctions of cutting tools should be pushed together rather than impacted, while ensuring as much concentricity as possible between the male and female taper and loading axis. This study devised six simple assembly methodologies to investigate how surgical variations affect the success of the compressive fit achieved at the taper interface compared to a controlled assembly method, designed to represent a more ‘ideal’ scenario. Key findings from this study suggest that a more successful and repeatable engagement can be achieved by quasi-statically loading the male and female taper concentrically with the loading axis. This was shown by a greater disassembly to assembly force ratio of 0.626 ± 0.07 when assembled using the more ‘ideal’ process, compared to 0.480 ± 0.05 when using a method closer to that used by a surgeon intraoperatively. Findings from this study can be used to help inform new surgical instrumentation and an improved surgical assembly method.