WEWilliam Evans

William Evans

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William Evans has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enabling nondestructive observation of electrolyte composition in batteries with ultralow-field nuclear magnetic resonance

    by Anne M. Fabricant, Román Picazo-Frutos, Florin Teleanu, Gregory Jon Rees, Raphael Kircher, Mengjiang Lin, William Evans, Paul-Martin Luc, Robert A. House, Peter G. Bruce, et al.

    Ultralow-field nuclear magnetic resonance has the power to see chemistry through metallic enclosures—enabling nondestructive quantitative tracking of the state and composition of liquid-state electrolytes in batteries.


  • Open Access

    Key Metrics and Experimental Test Bench for Assessing Highly Sensitive Magnetometers in Research

    by Eric Elzenheimer, Silvia Knappe-Grüneberg, Jan Zerfowski, William Evans, Fabian Grüneberg, Michael Höft, Surjo R. Soekadar, Stephen Robinson, Jens Voigt

    Ultra-low magnetic field sensing is rapidly emerging as a technology in various applications, providing a non-invasive and instantaneous method of data acquisition. The increasing availability of improved or innovative types of magnetometers promotes the need for a benchmark metric. This contribution focuses on the evaluation of single magnetometer devices that detect magnetic fields in the femtotesla range and are usually used in a magnetically shielded environment. For assessment, a Device Alignment Actuator system is presented that enables an accurate 3D alignment of the Device Under Test around a single point within a known, homogeneous magnetic test field inside the highly magnetically shielded room, called BMSR-2.1 at the Physikalisch-Technische Bundesanstalt Berlin, Germany. The defined benchmark metric includes several key parameters, such as frequency response, amplitude stability, frequency stability, and directivity, to name just a few. These parameters are introduced by using different commercial state-of-the-art optically pumped magnetometers (SERF-OPMs) and compared to the reference system based on superconducting quantum interference devices, which remain the gold standard in magnetometry. This approach ensures consistent evaluation across different magnetometer types, provided they operate at room temperature and fit within the evaluation platform. The platform can also be adapted for multi-channel magnetometer systems.


  • Open Access

    A modular optically pumped magnetometer system

    by T Coussens, A Gialopsou, C Abel, M G Bason, T M James, W Evans, M T M Woodley, D Nightingale, D Nicolau, L Page, et al.

    To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.


  • Open Access

    Quantum Gas-Enabled Direct Mapping of Active Current Density in Percolating Networks of Nanowires

    by Julia Fekete, Poppy Joshi, Thomas J. Barrett, Timothy Martin James, Robert Shah, Amruta Gadge, Shobita Bhumbra, William Evans, Manoj Tripathi, Matthew Large, et al.

    Electrically percolating nanowire networks are among the most promising candidates for next-generation transparent electrodes. Scientific interest in these materials stems from their intrinsic current distribution heterogeneity, leading to phenomena like percolating pathway rerouting and localized self-heating, which can cause irreversible damage. Without an experimental technique to resolve the current distribution and an underpinning nonlinear percolation model, one relies on empirical rules and safety factors to engineer materials. We introduce Bose-Einstein condensate microscopy to address the longstanding problem of imaging active current flow in 2D materials. We report on performance improvement of this technique whereby observation of dynamic redistribution of current pathways becomes feasible. We show how this, combined with existing thermal imaging methods, eliminates the need for assumptions between electrical and thermal properties. This will enable testing and modeling individual junction behavior and hot-spot formation. Investigating both reversible and irreversible mechanisms will contribute to improved performance and reliability of devices.


  • Open Access

    An environmental monitoring network for quantum gas experiments and devices

    by Thomas Barrett, William Evans, Amruta Gadge, Shobita Bhumbra, Scott Sleegers, Robert Shah, Julia Fekete, Fedja Orucevic, P Krüger, Peter Krueger

    Quantum technology is approaching a level of maturity, recently demonstrated in space-borne experiments and in-field measurements, which would allow for adoption by non-specialist users. Parallel advancements made in microprocessor-based electronics and database software can be combined to create robust, versatile and modular experimental monitoring systems. Here, we describe a monitoring network used across a number of cold atom laboratories with a shared laser system. The ability to diagnose malfunction, unexpected or unintended behavior and passively collect data for key experimental parameters, such as vacuum chamber pressure, laser beam power, or resistances of important conductors, significantly reduces debugging time. This allows for efficient control over a number of experiments and remote control when access is limited.


  • Inequalities and Operators Involving Magnetic Fields

    by Alexander A. Balinsky, W. Desmond Evans, Roger T. Lewis

  • Hardy, Sobolev, Maz’ya (HSM) Inequalities

    by Alexander A. Balinsky, W. Desmond Evans, Roger T. Lewis

  • Open Access

    On the evaluation of the norm of an integral operator associated with the stability of one-electron atoms

    by V. I. Burenkov, W. D. Evans

    The norm of an integral operator occurring in the partial wave decomposition of an operator B introduced by Brown and Ravenhall in a model for relativistic one-electron atoms is determined. The result implies that B is non-negative and has no eigenvalue at 0 when the nuclear charge does not exceed a specified critical value.