Jacob McAloney
Research Subjects
Research Interests
Jacob McAloney has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Matthew Sobolewski
2 shared publicationsCody Crewson
1 shared publication- Derek R. Lane1 shared publication
- Fada Guan
Department of Radiation Physics MD Anderson Cancer Center Houston Texas USA
1 shared publication - Jacob Rembish1 shared publication
- Matthew Jennings
School of Chemistry & Physics, University of Adelaide, Adelaide, SA 5000, Australia ; Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000, Australia
1 shared publication
Latest Publications
- Open Access
- 16 October 2022
- Published by The Open Journal in Journal of Open Source Software
- Vol. 7 (78) , 4555
PyMedPhys: A community effort to develop an open, Python-based standard library for medical physics applications
- 16 October 2022
- Published by The Open Journal in Journal of Open Source Software
- Vol. 7 (78) , 4555
Open AccessPyMedPhys: A community effort to develop an open, Python-based standard library for medical physics applications
- 25 October 2021
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 44 (4) , 1377-1382
Linac reported steering error insensitive to 6 MV FFF transverse beam position deviations
Clinically significant beam position deviations were observed for a 6 MV FFF beam during patient specific QA on an Elekta linear accelerator. There was no significant reported transverse steering error from the machine ion chamber, and routine linac QA practices, including cardinal angle Winston-Lutz test, did not identify the deviations. Subsequent investigation using an electronic portal imaging device (EPID) revealed clinically significant beam position deviations for small steering errors. This prompted investigation into further impact and possible solutions. Testing set-points were established by adjusting transverse steering current to achieve introduced 2 T steering errors. Tests at each set-point included scanning water tank profiles and EPID images. A proposed method for adjusting the 2 T error sensitivity was tested via adjusting the 2 T loop parameter such that a reported error corresponds to specific beam position deviations. The testing set-points resulted in positional deviations of greater than 3 mm for reported errors of less than 1. A new method for improving 2 T error sensitivity was implemented. This work has shown that existing vendor protocol for establishing beam steering error for 6 MV FFF beams can lead to beam position deviations without machine interlocks or significant reported steering errors. Thus, an alternative method of establishing steering error sensitivity based on positional deviations is presented.
- 25 October 2021
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 44 (4) , 1377-1382
Linac reported steering error insensitive to 6 MV FFF transverse beam position deviations
Clinically significant beam position deviations were observed for a 6 MV FFF beam during patient specific QA on an Elekta linear accelerator. There was no significant reported transverse steering error from the machine ion chamber, and routine linac QA practices, including cardinal angle Winston-Lutz test, did not identify the deviations. Subsequent investigation using an electronic portal imaging device (EPID) revealed clinically significant beam position deviations for small steering errors. This prompted investigation into further impact and possible solutions. Testing set-points were established by adjusting transverse steering current to achieve introduced 2 T steering errors. Tests at each set-point included scanning water tank profiles and EPID images. A proposed method for adjusting the 2 T error sensitivity was tested via adjusting the 2 T loop parameter such that a reported error corresponds to specific beam position deviations. The testing set-points resulted in positional deviations of greater than 3 mm for reported errors of less than 1. A new method for improving 2 T error sensitivity was implemented. This work has shown that existing vendor protocol for establishing beam steering error for 6 MV FFF beams can lead to beam position deviations without machine interlocks or significant reported steering errors. Thus, an alternative method of establishing steering error sensitivity based on positional deviations is presented.