Yaping Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yaping Zhong has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Dong Wang
Wuhan Textile University
6 shared publications Lijuan Guo
Key Laboratory of Textile Fiber and Products (Wuhan Textile University), Ministry of Education, Hubei International Scientific and Technological Cooperation Base of Intelligent Textile Materials &Application, Wuhan Textile University, Wuhan 430200, China
5 shared publicationsKayi Shao
4 shared publicationsLinlong Zhang
4 shared publicationsYibiao Zou
Key Laboratory of Textile Fiber and Products (Wuhan Textile University), Ministry of Education, Hubei International Scientific and Technological Cooperation Base of Intelligent Textile Materials &Application, Wuhan Textile University, Wuhan 430200, China
4 shared publications- Zhentan Lu
Wuhan Textile University
4 shared publications
Latest Publications
- 2 November 2025
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 704 (Pt 1) , 139393
Glutathione-responsive oxidative stress nanoamplifier boosts sonodynamic/chemodynamic synergistic antibacterial therapy
- 2 November 2025
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 704 (Pt 1) , 139393
Glutathione-responsive oxidative stress nanoamplifier boosts sonodynamic/chemodynamic synergistic antibacterial therapy
- 23 September 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 326, 125189
Molybdenum disulfide quantum dots for rapid fluorescence detection of glutathione and ascorbic acid
- 23 September 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 326, 125189
Molybdenum disulfide quantum dots for rapid fluorescence detection of glutathione and ascorbic acid
- 9 April 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (8) , 8645-8654
Carbon Quantum Dots for Rapid and Ratiometric Fluorescence Determination of Hypochlorite
- 9 April 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (8) , 8645-8654
Carbon Quantum Dots for Rapid and Ratiometric Fluorescence Determination of Hypochlorite
- 21 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 6 (23) , 22355-22362
Cys-Functionalized MoS2 Quantum Dots and Calcium Ion for Ratiometric Fluorescence Probes for Doxycycline
- 21 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 6 (23) , 22355-22362
Cys-Functionalized MoS2 Quantum Dots and Calcium Ion for Ratiometric Fluorescence Probes for Doxycycline
- 6 December 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (1) , 1-12
3-Aminophenylboronic acid–functionalized molybdenum disulfide quantum dots for fluorescent determination of hypochlorite
A simple method is reported for hypochlorite determination based on fluorescence 3-aminophenylboronic acid–functionalized molybdenum disulfide quantum dots (B-MoS2 QDs). B-MoS2 QDs with strong fluorescence at 380 nm have been successfully synthesized by the amidation reaction between APBA and hydrothermal MoS2 QDs. Hypochlorite sensing was proposed utilizing the fluorescent quenching effect of 3,3ʹ,5,5ʹ-tetramethylbenzidine dihydrochloride (TMB) on B-MoS2 QDs and the fast redox reaction between hypochlorite and TMB. The fluorescent quenching effect of TMB to B-MoS2 QDs was proved to be caused by static dynamic quenching and inner filter effect. A good linear relationship was obtained in the hypochlorite concentration range from 1 to 20 μM, and the limit of detection (LOD) was 36.8 nM. The proposed fluorescent detection assay was simple and fast, taking only 5 min at room temperature. Satisfactory results were obtained in the standard spike recovery tests on tap water and milk samples, which indicate high potential in constructing fluorescent bio-detection assays. Graphical Abstract
- 6 December 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (1) , 1-12
3-Aminophenylboronic acid–functionalized molybdenum disulfide quantum dots for fluorescent determination of hypochlorite
A simple method is reported for hypochlorite determination based on fluorescence 3-aminophenylboronic acid–functionalized molybdenum disulfide quantum dots (B-MoS2 QDs). B-MoS2 QDs with strong fluorescence at 380 nm have been successfully synthesized by the amidation reaction between APBA and hydrothermal MoS2 QDs. Hypochlorite sensing was proposed utilizing the fluorescent quenching effect of 3,3ʹ,5,5ʹ-tetramethylbenzidine dihydrochloride (TMB) on B-MoS2 QDs and the fast redox reaction between hypochlorite and TMB. The fluorescent quenching effect of TMB to B-MoS2 QDs was proved to be caused by static dynamic quenching and inner filter effect. A good linear relationship was obtained in the hypochlorite concentration range from 1 to 20 μM, and the limit of detection (LOD) was 36.8 nM. The proposed fluorescent detection assay was simple and fast, taking only 5 min at room temperature. Satisfactory results were obtained in the standard spike recovery tests on tap water and milk samples, which indicate high potential in constructing fluorescent bio-detection assays. Graphical Abstract
- 29 November 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (12) , 1-12
Co(OH)2/MXene-Ti3C2 nanocomposites with triple-enzyme mimic activities as hydrogel sensing platform for on-site detection of hypoxanthine
Novel Co(OH)2/MXene-Ti3C2 nanocomposites with oxidase (OXD)-mimic, peroxidase (POD)-mimic, and catalase (CAT)-mimic activities were prepared by a simple two-step method. The Co(OH)2/MXene-Ti3C2 nanocomposites with triple-enzyme mimic activities were embedded into sodium alginate (SA) gels for the first time to fabricate a target-responsive hydrogel-assisted assay. The catalytic mechanism and steady-state kinetics of Co(OH)2/MXene-Ti3C2 nanocomposites were investigated. Subsequently, hypoxanthine (Hx) was catalyzed by xanthine oxidase (XOD) to form H2O2, which reacts with 3,3′,5,5′-tetramethyl-benzidine (TMB) in the presence of Co(OH)2/MXene-Ti3C2 nanocomposites to form a blue oxide (ox-TMB) in the hydrogel. The visible color change of the hydrogel with the increase of Hx concentration can be recognized through a smartphone App to transfer the red (R), green (G), and blue (B) values for the quantitative determination of Hx, with a detection range from 5 to 250 μM, and detection limit of 0.2 μM. The method was applied to the determination of Hx content in different aquatic products. The spiked recoveries of the aquatic products were from 94.1 to 106.4%, and the relative standard deviations (RSD) were less than 5.4%. Our results show that the Co(OH)2/MXene-Ti3C2 nanocomposites hydrogel-assisted colorimetric biosensor is cost-effective, sensitive, and selective and has excellent application prospects for in-the-field determination of Hx. Graphical abstract
- 29 November 2022
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (12) , 1-12
Co(OH)2/MXene-Ti3C2 nanocomposites with triple-enzyme mimic activities as hydrogel sensing platform for on-site detection of hypoxanthine
Novel Co(OH)2/MXene-Ti3C2 nanocomposites with oxidase (OXD)-mimic, peroxidase (POD)-mimic, and catalase (CAT)-mimic activities were prepared by a simple two-step method. The Co(OH)2/MXene-Ti3C2 nanocomposites with triple-enzyme mimic activities were embedded into sodium alginate (SA) gels for the first time to fabricate a target-responsive hydrogel-assisted assay. The catalytic mechanism and steady-state kinetics of Co(OH)2/MXene-Ti3C2 nanocomposites were investigated. Subsequently, hypoxanthine (Hx) was catalyzed by xanthine oxidase (XOD) to form H2O2, which reacts with 3,3′,5,5′-tetramethyl-benzidine (TMB) in the presence of Co(OH)2/MXene-Ti3C2 nanocomposites to form a blue oxide (ox-TMB) in the hydrogel. The visible color change of the hydrogel with the increase of Hx concentration can be recognized through a smartphone App to transfer the red (R), green (G), and blue (B) values for the quantitative determination of Hx, with a detection range from 5 to 250 μM, and detection limit of 0.2 μM. The method was applied to the determination of Hx content in different aquatic products. The spiked recoveries of the aquatic products were from 94.1 to 106.4%, and the relative standard deviations (RSD) were less than 5.4%. Our results show that the Co(OH)2/MXene-Ti3C2 nanocomposites hydrogel-assisted colorimetric biosensor is cost-effective, sensitive, and selective and has excellent application prospects for in-the-field determination of Hx. Graphical abstract
- 7 December 2021
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (1) , 1-12
Ascorbic acid detector based on fluorescent molybdenum disulfide quantum dots
A rapid and facile method is reported for the detection of ascorbic acid using molybdenum disulfide quantum dots (MoS2 QDs) as a fluorescence sensor. Water-soluble and biocompatible MoS2 QDs with the maximum fluorescence emission at 506 nm have been successfully synthesized by hydrothermal method and specific detection for ascorbic acid (AA) was constructed to utilize the modulation of metal ion on the fluorescence of MoS2 QDs and the affinity and specificity between the ligand and the metal ion. The fluorescence of MoS2 QDs was quenched by the irreversible static quenching of Fe3+ through the formation of a MoS2 QDs/Fe3+ complex, while the pre-existence of AA can retain the fluorescence of MoS2 QDs through the redox reaction between AA and Fe3+. Based on this principle, a good linear relationship was obtained in the AA concentration range 1 to 150 μM with a detection limit of 50 nM. The proposed fluorescent sensing strategy was proven to be highly selective, quite simple, and rapid with a requirement of only 5 min at room temperature (RT), which is particularly useful for rapid and easy analysis. Satisfactory results were obtained when applied to AA determination in fruits, beverages, and serum samples as well as AA imaging in living cells, suggesting its great potential in constructing other fluorescence detection and imaging platforms. Graphical abstract
- 7 December 2021
- Published by Springer Nature in Microchimica Acta
- Vol. 189 (1) , 1-12
Ascorbic acid detector based on fluorescent molybdenum disulfide quantum dots
A rapid and facile method is reported for the detection of ascorbic acid using molybdenum disulfide quantum dots (MoS2 QDs) as a fluorescence sensor. Water-soluble and biocompatible MoS2 QDs with the maximum fluorescence emission at 506 nm have been successfully synthesized by hydrothermal method and specific detection for ascorbic acid (AA) was constructed to utilize the modulation of metal ion on the fluorescence of MoS2 QDs and the affinity and specificity between the ligand and the metal ion. The fluorescence of MoS2 QDs was quenched by the irreversible static quenching of Fe3+ through the formation of a MoS2 QDs/Fe3+ complex, while the pre-existence of AA can retain the fluorescence of MoS2 QDs through the redox reaction between AA and Fe3+. Based on this principle, a good linear relationship was obtained in the AA concentration range 1 to 150 μM with a detection limit of 50 nM. The proposed fluorescent sensing strategy was proven to be highly selective, quite simple, and rapid with a requirement of only 5 min at room temperature (RT), which is particularly useful for rapid and easy analysis. Satisfactory results were obtained when applied to AA determination in fruits, beverages, and serum samples as well as AA imaging in living cells, suggesting its great potential in constructing other fluorescence detection and imaging platforms. Graphical abstract
- 11 October 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (43) , 5211-5215
A simple colorimetric method for viable bacteria detection based on cell counting Kit-8
In this study, Cell Counting Kit-8 (CCK-8) was introduced to detect the concentration of live bacteria for the first time depending on the redox reaction between CCK-8 solution and dehydrogenase. CCK-8 solution can be reduced to form water soluble orange-yellow formazan by the dehydrogenase present in bacterial cells, and the concentration of live bacteria is proportional to the absorbance value of formazan at 450 nm. Based on this principle, Staphylococcus aureus and Escherichia coli were chosen as the model bacteria. The optimal detection conditions were investigated and a good linear relationship was obtained in the concentration range from 2.600 × 102 to 1.160 × 109 CFU mL−1 with a linear equation of Y = 0.06305 log10 X-0.1153 (X in CFU mL−1, R2 = 0.9747) for S. aureus and 9.750 × 102 to 6.000 × 108 CFU mL−1 with a linear equation of Y = 0.06122 log10 X-0.1358 (X in CFU mL−1, R2 = 0.9958) for E. coli. The CCK-8 based viable bacteria detection method can be completed within 2 h with a wide bacterial detection concentration range. Satisfactory results were obtained when applied to an actual sample analysis and there is a good consistency between the proposed CCK-8 based method and the traditional plate counting method. More importantly, this method can realize the one-time detection of a large number of samples with high sensitivity, which suggests its great potential in high-throughput bacterial detection.
- 11 October 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (43) , 5211-5215
A simple colorimetric method for viable bacteria detection based on cell counting Kit-8
In this study, Cell Counting Kit-8 (CCK-8) was introduced to detect the concentration of live bacteria for the first time depending on the redox reaction between CCK-8 solution and dehydrogenase. CCK-8 solution can be reduced to form water soluble orange-yellow formazan by the dehydrogenase present in bacterial cells, and the concentration of live bacteria is proportional to the absorbance value of formazan at 450 nm. Based on this principle, Staphylococcus aureus and Escherichia coli were chosen as the model bacteria. The optimal detection conditions were investigated and a good linear relationship was obtained in the concentration range from 2.600 × 102 to 1.160 × 109 CFU mL−1 with a linear equation of Y = 0.06305 log10 X-0.1153 (X in CFU mL−1, R2 = 0.9747) for S. aureus and 9.750 × 102 to 6.000 × 108 CFU mL−1 with a linear equation of Y = 0.06122 log10 X-0.1358 (X in CFU mL−1, R2 = 0.9958) for E. coli. The CCK-8 based viable bacteria detection method can be completed within 2 h with a wide bacterial detection concentration range. Satisfactory results were obtained when applied to an actual sample analysis and there is a good consistency between the proposed CCK-8 based method and the traditional plate counting method. More importantly, this method can realize the one-time detection of a large number of samples with high sensitivity, which suggests its great potential in high-throughput bacterial detection.