Alishir B. Gamzaev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alishir B. Gamzaev has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Сослан Тайсумович Энгиноев
Federal Center for Cardiovascular Surgery, Ministry of Health of Russia; Astrakhan State Medical University, Ministry of Health of Russia
11 shared publications - Igor I. Chernov
Federal Center for Cardiovascular Surgery of the Ministry of Health of the Russian Federation (FCCVS (Astrakhan))
10 shared publications - A. P. Semagin
Polyakov Samara Regional Clinical Cardiology Dispensary
6 shared publications - Bakytbek K. Kadyraliev
FCCS named after S.G. Sukhanov
6 shared publications - Boris M. Tlisov
Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University)
6 shared publications - D. V. Kuznetsov
Polyakov Samara Regional Clinical Cardiology Dispensary
6 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 30 (3) , 65-77
Immediate Outcomes of Heart Valve Prostheses with a Rapid-Deployment Sutureless Cuff versus Standard Sutured Prostheses in the Correction of Degenerative Aortic Valve Failure
Introduction: Sutureless valves represent an alternative approach to aortic valve replacement, enabling rapid prosthesis implantation without placement of multiple interrupted sutures. Objective: To compare prostheses with a rapid-deployment sutureless cuff with standard sutured prostheses in patients with degenerative aortic valve disease. Methods: This prospective, single-centre, non-randomised pilot studyincluded 105 patients who underwent aortic valve replacement between January 2022 and March 2024. Patients were allocated to three groups: a rapid-deployment sutureless cuff with mechanical or biological valve cartridges (n = 35), the Medeng-2 mechanical prosthesis (n = 41), and the UniLine biological prosthesis (n = 29). The primary endpoints were allcause and prosthesis-related mortality within 30 days. Secondary endpoints included mean transprosthetic pressure gradients at discharge and the frequency and nature of complications. Results: The groups were comparable for most preoperative characteristics,including EuroSCORE II (p = 0.213). Statistically significant differenceswere observed in age and left ventricular ejection fraction, reflectingclinical selection rather than systematic differences in operative risk. Cardiopulmonary bypass and aortic cross-clamp times were significantlyshorter in the sutureless cuff group (p < 0.001). Thirty-day all-cause mortalitywas 8.6% (3/35) in the RDSC group, 7.3% (3/41) in the Medeng-2 group, and 3.3% (1/29) in the UniLine group (p = 0.78). Permanent pacemaker implantation rates were 8.8%, 0%, and 3.3%, respectively (p = 0.18). At discharge, mean pressure gradients were lower in the sutureless cuff group than in the mechanical prosthesis group. Conclusion: Preliminary findings from this pilot study suggest that a rapid-deployment sutureless cuff reduces operative time and provides satisfactory early haemodynamic outcomes. Further studies are required to confirm safety with respect to rare complications and to evaluate longterm outcomes. Received 18 April 2026. Revised 22 June 2026. Accepted 4 August 2026. Informed consentThe patient’s informed consent to use the records for medical purposes is obtained. FundingThe study did not have sponsorship. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev, A.A. Golubev Data collection and analysis: A.M. Osipov, M.L. Kalinina, M.B. Sukhova, E. Kurmanbek uulu, D.I. Lashmanov Statistical analysis: A.M. Osipov Drafting the article: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev Critical revision of the article: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev Final approval of the version to be published: all authors
- 21 October 2026
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 30 (3) , 65-77
Open AccessImmediate Outcomes of Heart Valve Prostheses with a Rapid-Deployment Sutureless Cuff versus Standard Sutured Prostheses in the Correction of Degenerative Aortic Valve Failure
Introduction: Sutureless valves represent an alternative approach to aortic valve replacement, enabling rapid prosthesis implantation without placement of multiple interrupted sutures. Objective: To compare prostheses with a rapid-deployment sutureless cuff with standard sutured prostheses in patients with degenerative aortic valve disease. Methods: This prospective, single-centre, non-randomised pilot studyincluded 105 patients who underwent aortic valve replacement between January 2022 and March 2024. Patients were allocated to three groups: a rapid-deployment sutureless cuff with mechanical or biological valve cartridges (n = 35), the Medeng-2 mechanical prosthesis (n = 41), and the UniLine biological prosthesis (n = 29). The primary endpoints were allcause and prosthesis-related mortality within 30 days. Secondary endpoints included mean transprosthetic pressure gradients at discharge and the frequency and nature of complications. Results: The groups were comparable for most preoperative characteristics,including EuroSCORE II (p = 0.213). Statistically significant differenceswere observed in age and left ventricular ejection fraction, reflectingclinical selection rather than systematic differences in operative risk. Cardiopulmonary bypass and aortic cross-clamp times were significantlyshorter in the sutureless cuff group (p < 0.001). Thirty-day all-cause mortalitywas 8.6% (3/35) in the RDSC group, 7.3% (3/41) in the Medeng-2 group, and 3.3% (1/29) in the UniLine group (p = 0.78). Permanent pacemaker implantation rates were 8.8%, 0%, and 3.3%, respectively (p = 0.18). At discharge, mean pressure gradients were lower in the sutureless cuff group than in the mechanical prosthesis group. Conclusion: Preliminary findings from this pilot study suggest that a rapid-deployment sutureless cuff reduces operative time and provides satisfactory early haemodynamic outcomes. Further studies are required to confirm safety with respect to rare complications and to evaluate longterm outcomes. Received 18 April 2026. Revised 22 June 2026. Accepted 4 August 2026. Informed consentThe patient’s informed consent to use the records for medical purposes is obtained. FundingThe study did not have sponsorship. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev, A.A. Golubev Data collection and analysis: A.M. Osipov, M.L. Kalinina, M.B. Sukhova, E. Kurmanbek uulu, D.I. Lashmanov Statistical analysis: A.M. Osipov Drafting the article: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev Critical revision of the article: S.A. Zhurko, A.M. Osipov, A.B. Gamzaev Final approval of the version to be published: all authors
- 30 July 2026
- Published by Media Sphere Publishing Group in Russian Journal of Cardiology and Cardiovascular Surgery
- Vol. 19 (4) , 51-56
Redo surgeries after total repair of tetralogy of Fallot
Objective. To study the causes of redo surgeries after total repair of tetralogy of Fallot and specific factors leading to complications. Material and methods. Between January 1986 and December 2024, 411 total corrections of tetralogy of Fallot were performed. Of these, 30 patients underwent redo surgeries for various complications. Thus, the redo surgery rate was 7.3%. Results. There were no deaths after redo surgery. Complicated postoperative period was observed in 3 (10%) patients. There was moderate heart failure with necessary inotropic support for 2—3 days. In addition, pericardial effusion was observed in 3 cases after 6—8 days with effective therapy. We found no significant differences in complication rates or hospital-stay between primary and redo surgeries. Conclusion. Redo surgeries after total correction of tetralogy of Fallot significantly improve the quality of life with favorable immediate and long-term results.
- 30 July 2026
- Published by Media Sphere Publishing Group in Russian Journal of Cardiology and Cardiovascular Surgery
- Vol. 19 (4) , 51-56
Redo surgeries after total repair of tetralogy of Fallot
Objective. To study the causes of redo surgeries after total repair of tetralogy of Fallot and specific factors leading to complications. Material and methods. Between January 1986 and December 2024, 411 total corrections of tetralogy of Fallot were performed. Of these, 30 patients underwent redo surgeries for various complications. Thus, the redo surgery rate was 7.3%. Results. There were no deaths after redo surgery. Complicated postoperative period was observed in 3 (10%) patients. There was moderate heart failure with necessary inotropic support for 2—3 days. In addition, pericardial effusion was observed in 3 cases after 6—8 days with effective therapy. We found no significant differences in complication rates or hospital-stay between primary and redo surgeries. Conclusion. Redo surgeries after total correction of tetralogy of Fallot significantly improve the quality of life with favorable immediate and long-term results.
- 24 June 2026
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Messenger of ANESTHESIOLOGY AND RESUSCITATION
- Vol. 23 (3)
The impact of intraoperative fluid therapy on the risk of hyperlactatemia in patients undergoing cardiac surgery with cardiopulmonary bypass: a prospective single-center study
The objective was to evaluate the association between the volume of intraoperative fluid therapy and the risk of postoperative hyperlactatemia in patients undergoing cardiac surgery with cardiopulmonary bypass. Materials and methods . This single-center prospective cohort study included 733 adult patients who underwent cardiac surgery with cardiopulmonary bypass between 2024 and 2025. The total intraoperative fluid volume (crystalloids and colloids), normalized to body weight (mL/kg), was used as the exposure variable; the priming volume of the cardiopulmonary bypass circuit was excluded from the analysis. Patients were stratified according to quartiles of fluid volume distribution: the first quartile (Q1) represented the low-volume («restrictive») group, the second and third quartiles (Q2–Q3) represented the moderate-volume group, and the fourth quartile (Q4) represented the high-volume («liberal») group. The quartile boundaries were calculated based on the distribution of infusion volume in the entire study cohort. Hyperlactatemia was defined as a lactate level ≥3 mmol/L within the first 6 hours after admission to the intensive care unit. The type of hyperlactatemia (ischemic or metabolic) was determined using a predefined algorithm incorporating lactate level, ScvO 2 , Pv-aCO₂, and lactate clearance at 6 hours. Indicators of tissue hypoperfusion included ScvO₂ < 65%, Pv–aCO₂ > 6 mmHg, and lactate clearance < 10%. Multinomial logistic regression was used to evaluate the independent association between fluid volume and hyperlactatemia type (no hyperlactatemia, ischemic type, metabolic type). Results . The overall incidence of postoperative hyperlactatemia (lactate ≥3.0 mmol/L within 6 hours after ICU admission) in the general cohort occurred in 30.2% of patients (n = 733). The median intraoperative fluid volume differed significantly between groups (p < 0.001). The incidence of ischemic hyperlactatemia demonstrated a U-shaped relationship with fluid volume: the lowest rate was observed in the moderate-volume group (9.5% per the entire group of patients), whereas in the low-volume («restrictive») group, the frequency increased (13.1%), and the probability of this type of hyperlactatemia also increased according to regression analysis (OR 1.52; 95% CI 1.01–2.29; p = 0.04), peaking in the high-volume («liberal») group (18.0%; OR 1.95; 95% CI 1.28–2.98; p = 0.002). When fluid volume was analyzed as a continuous variable, the lowest predicted risk of ischemic hyperlactatemia corresponded to an infusion range of approximately 35–45 mL/kg. The incidence of metabolic hyperlactatemia differed between groups (p = 0,001), but without a consistent pattern and without a nonlinear association. Conclusion . In patients undergoing cardiac surgery with cardiopulmonary bypass, a U-shaped association was observed between the volume of intraoperative fluid therapy and the risk of ischemic hyperlactatemia following cardiac surgery with cardiopulmonary bypass. The lowest risk of hypoperfusion-related hyperlactatemia was observed with a moderate fluid volume of approximately 35–45 mL/kg. These findings suggest that a moderate intraoperative fluid strategy may be associated with a more favorable postoperative tissue perfusion profile in cardiac surgical patients.
- 24 June 2026
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Messenger of ANESTHESIOLOGY AND RESUSCITATION
- Vol. 23 (3)
The impact of intraoperative fluid therapy on the risk of hyperlactatemia in patients undergoing cardiac surgery with cardiopulmonary bypass: a prospective single-center study
The objective was to evaluate the association between the volume of intraoperative fluid therapy and the risk of postoperative hyperlactatemia in patients undergoing cardiac surgery with cardiopulmonary bypass. Materials and methods . This single-center prospective cohort study included 733 adult patients who underwent cardiac surgery with cardiopulmonary bypass between 2024 and 2025. The total intraoperative fluid volume (crystalloids and colloids), normalized to body weight (mL/kg), was used as the exposure variable; the priming volume of the cardiopulmonary bypass circuit was excluded from the analysis. Patients were stratified according to quartiles of fluid volume distribution: the first quartile (Q1) represented the low-volume («restrictive») group, the second and third quartiles (Q2–Q3) represented the moderate-volume group, and the fourth quartile (Q4) represented the high-volume («liberal») group. The quartile boundaries were calculated based on the distribution of infusion volume in the entire study cohort. Hyperlactatemia was defined as a lactate level ≥3 mmol/L within the first 6 hours after admission to the intensive care unit. The type of hyperlactatemia (ischemic or metabolic) was determined using a predefined algorithm incorporating lactate level, ScvO 2 , Pv-aCO₂, and lactate clearance at 6 hours. Indicators of tissue hypoperfusion included ScvO₂ < 65%, Pv–aCO₂ > 6 mmHg, and lactate clearance < 10%. Multinomial logistic regression was used to evaluate the independent association between fluid volume and hyperlactatemia type (no hyperlactatemia, ischemic type, metabolic type). Results . The overall incidence of postoperative hyperlactatemia (lactate ≥3.0 mmol/L within 6 hours after ICU admission) in the general cohort occurred in 30.2% of patients (n = 733). The median intraoperative fluid volume differed significantly between groups (p < 0.001). The incidence of ischemic hyperlactatemia demonstrated a U-shaped relationship with fluid volume: the lowest rate was observed in the moderate-volume group (9.5% per the entire group of patients), whereas in the low-volume («restrictive») group, the frequency increased (13.1%), and the probability of this type of hyperlactatemia also increased according to regression analysis (OR 1.52; 95% CI 1.01–2.29; p = 0.04), peaking in the high-volume («liberal») group (18.0%; OR 1.95; 95% CI 1.28–2.98; p = 0.002). When fluid volume was analyzed as a continuous variable, the lowest predicted risk of ischemic hyperlactatemia corresponded to an infusion range of approximately 35–45 mL/kg. The incidence of metabolic hyperlactatemia differed between groups (p = 0,001), but without a consistent pattern and without a nonlinear association. Conclusion . In patients undergoing cardiac surgery with cardiopulmonary bypass, a U-shaped association was observed between the volume of intraoperative fluid therapy and the risk of ischemic hyperlactatemia following cardiac surgery with cardiopulmonary bypass. The lowest risk of hypoperfusion-related hyperlactatemia was observed with a moderate fluid volume of approximately 35–45 mL/kg. These findings suggest that a moderate intraoperative fluid strategy may be associated with a more favorable postoperative tissue perfusion profile in cardiac surgical patients.
- Open Access
- 1 January 2026
- Published by A.V. Vishnevsky National Medical Research Center of Surgery of the Ministry of Healthcare of the Russian Federation in Minimally Invasive Cardiovascular Surgery
- Vol. 2 (2) , 28-38
COMPARISON OF ENDOSCOPIC AND OPEN GREAT SAPHENOUS VEIN HARVESTING IN OFF-PUMP CORONARY ARTERY BYPASS GRAFTING: A RETROSPECTIVE PROPENSITY SCORE-MATCHED STUDY
Цель: оценить непосредственные и отдалённые результаты эндоскопического и открытого забора БПВ при КШ на работающем сердце. Материалы и методы: выполнен ретроспективный одноцентровый анализ результатов КШ на работающем сердце у 1851 пациента, оперированного в период с 2009 по 2022 гг. В зависимости от методики забора БПВ пациенты были разделены на две группы: эндо- скопический забор БПВ — 115 пациентов и открытый забор БПВ — 1736 пациентов. Для минимизации влияния исходной неоднород- ности групп выполнена propensity score matching (PSM), после чего сформированы две сопоставимые группы по 114 пациентов. Оце- нивались интраоперационные показатели, ранние послеоперационные осложнения, госпитальная летальность и отдалённая выживаемость. Результаты: частота проблем с заживлением раны нижней конечности была статистически значимо ниже в группе эндоскопического забора БПВ по сравнению с открытым способом (0% против 8,8%; p<0,001). Различий по частоте периоперационного ИМ (1,8% про- тив 0,9%; p=1,0), инсульта (1,8% против 2,6%; p=1,0), ОПП (0,9% против 3,5%; p=0,369), ПОФП (9,6% против 10,5%; p=0,826) и госпи- тальной летальности (1,8% против 0,9%; p=1,0) выявлено не было. Медиана периода наблюдения составила 77 [10–125] месяцев. Десятилетняя выживаемость составила 86,0% в группе эндоскопического забора и 91,6% в группе открытого доступа без статистиче- ски значимых различий между кривыми Каплана–Мейера. Заключение: эндоскопический забор БПВ при КШ на работающем сердце является безопасной и клинически эффективной методи- кой, обеспечивающей значительное снижение частоты раневых осложнений нижней конечности без ухудшения непосредственных и отдалённых результатов хирургической реваскуляризации миокарда
- 1 January 2026
- Published by A.V. Vishnevsky National Medical Research Center of Surgery of the Ministry of Healthcare of the Russian Federation in Minimally Invasive Cardiovascular Surgery
- Vol. 2 (2) , 28-38
Open AccessCOMPARISON OF ENDOSCOPIC AND OPEN GREAT SAPHENOUS VEIN HARVESTING IN OFF-PUMP CORONARY ARTERY BYPASS GRAFTING: A RETROSPECTIVE PROPENSITY SCORE-MATCHED STUDY
Цель: оценить непосредственные и отдалённые результаты эндоскопического и открытого забора БПВ при КШ на работающем сердце. Материалы и методы: выполнен ретроспективный одноцентровый анализ результатов КШ на работающем сердце у 1851 пациента, оперированного в период с 2009 по 2022 гг. В зависимости от методики забора БПВ пациенты были разделены на две группы: эндо- скопический забор БПВ — 115 пациентов и открытый забор БПВ — 1736 пациентов. Для минимизации влияния исходной неоднород- ности групп выполнена propensity score matching (PSM), после чего сформированы две сопоставимые группы по 114 пациентов. Оце- нивались интраоперационные показатели, ранние послеоперационные осложнения, госпитальная летальность и отдалённая выживаемость. Результаты: частота проблем с заживлением раны нижней конечности была статистически значимо ниже в группе эндоскопического забора БПВ по сравнению с открытым способом (0% против 8,8%; p<0,001). Различий по частоте периоперационного ИМ (1,8% про- тив 0,9%; p=1,0), инсульта (1,8% против 2,6%; p=1,0), ОПП (0,9% против 3,5%; p=0,369), ПОФП (9,6% против 10,5%; p=0,826) и госпи- тальной летальности (1,8% против 0,9%; p=1,0) выявлено не было. Медиана периода наблюдения составила 77 [10–125] месяцев. Десятилетняя выживаемость составила 86,0% в группе эндоскопического забора и 91,6% в группе открытого доступа без статистиче- ски значимых различий между кривыми Каплана–Мейера. Заключение: эндоскопический забор БПВ при КШ на работающем сердце является безопасной и клинически эффективной методи- кой, обеспечивающей значительное снижение частоты раневых осложнений нижней конечности без ухудшения непосредственных и отдалённых результатов хирургической реваскуляризации миокарда
- Open Access
- 5 October 2025
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 40 (3) , 161-169
Hospital outcomes of transaortic implantation of the «MedLAB-CT» prosthesis in patients with combined coronary artery disease: a single-center study
Introduction. Aortic valve replacement (AVR) is one of the most frequently performed procedures in cardiac surgery, which significantly improves the quality of life and increases its duration. Recently, transcatheter aortic valve implantation (TAVI) has been actively used, which is especially important in patients with concomitant pathology, in particular coronary heart disease (CHD). In this article, we describe the experience of successful surgical treatment of patients who underwent TAVI in combination with coronary artery bypass grafting.Aim: To compare the results of open transaortic implantation of the “MedLAB–CT” prosthesis in combination with coronary bypass surgery, in comparison with similar indicators when replacing the aortic valve with a mechanical prosthesis with coronary artery bypass grafting, at the hospital stage.Material and Methods. Patients operated in the clinic from June 2020 to November 2023. A retrospective observational comparison of the results of surgical treatment of two groups of patients was performed: Group 1 study group, which consisted of 60 patients who underwent open transaortic implantation of the prosthesis “MedLAB-CT” in combination with CABG. Group 2 control group, it included 99 patients who underwent AVR with a mechanical prosthesis and CABG. Using the Propensity Score Matching (PSM) pseudorandomization method, 60 patients were selected from the comparison group.Results. Cardiopulmonary bypass time was significantly less in the “MedLAB-CT” + CABG group – 57.4 ± 8.3 min (p = 0.003). A statistical difference in the time of aortic clamping was revealed: in the study group had a value of 43.2 ± 5.2 min, in the comparison group 75.4 ± 9.2 min (p = 0.002). There were no statistically significant differences in the duration of surgery (p = 0.224), length of stay in the intensive care unit (p = 0.805) and hospitalization (p = 0.783).Conclusion. The proposed method of open transaortic implantation of the MedLAB-CT prosthesis in combination with coronary bypass surgery can significantly reduce the time of cardiopulmonary bypass and myocardial ischemia, which has a positive effect on the course of the postoperative period.
- 5 October 2025
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 40 (3) , 161-169
Open AccessHospital outcomes of transaortic implantation of the «MedLAB-CT» prosthesis in patients with combined coronary artery disease: a single-center study
Introduction. Aortic valve replacement (AVR) is one of the most frequently performed procedures in cardiac surgery, which significantly improves the quality of life and increases its duration. Recently, transcatheter aortic valve implantation (TAVI) has been actively used, which is especially important in patients with concomitant pathology, in particular coronary heart disease (CHD). In this article, we describe the experience of successful surgical treatment of patients who underwent TAVI in combination with coronary artery bypass grafting.Aim: To compare the results of open transaortic implantation of the “MedLAB–CT” prosthesis in combination with coronary bypass surgery, in comparison with similar indicators when replacing the aortic valve with a mechanical prosthesis with coronary artery bypass grafting, at the hospital stage.Material and Methods. Patients operated in the clinic from June 2020 to November 2023. A retrospective observational comparison of the results of surgical treatment of two groups of patients was performed: Group 1 study group, which consisted of 60 patients who underwent open transaortic implantation of the prosthesis “MedLAB-CT” in combination with CABG. Group 2 control group, it included 99 patients who underwent AVR with a mechanical prosthesis and CABG. Using the Propensity Score Matching (PSM) pseudorandomization method, 60 patients were selected from the comparison group.Results. Cardiopulmonary bypass time was significantly less in the “MedLAB-CT” + CABG group – 57.4 ± 8.3 min (p = 0.003). A statistical difference in the time of aortic clamping was revealed: in the study group had a value of 43.2 ± 5.2 min, in the comparison group 75.4 ± 9.2 min (p = 0.002). There were no statistically significant differences in the duration of surgery (p = 0.224), length of stay in the intensive care unit (p = 0.805) and hospitalization (p = 0.783).Conclusion. The proposed method of open transaortic implantation of the MedLAB-CT prosthesis in combination with coronary bypass surgery can significantly reduce the time of cardiopulmonary bypass and myocardial ischemia, which has a positive effect on the course of the postoperative period.
- 25 April 2025
- Published by Media Sphere Publishing Group in Russian Journal of Cardiology and Cardiovascular Surgery
- Vol. 18 (2)
Immediate and mid-term results of the Ross and Ozaki procedures in adults
Objective. To compare the immediate and mid-term results of the AVNeo and Ross procedures for aortic valve disease in adults. Material and methods. After PSM, we distinguished 2 groups by 30 patients: group I — the AVNeo procedure (n=30), group II (n=30) — the Ross procedure. Inclusion criteria: patients aged ≥16 years who underwent the Ross or AVNeo surgery. There were no exclusion criteria. The median follow-up period was 27 [13; 76] months (24 [17; 32] and 80 [33; 103], respectively). Results. Demographic and preoperative clinical and echocardiographic characteristics after PSM did not differ between groups. Mean age of patients was 48 [37; 59] and 50 [42; 54] years, respectively (p=0.707). Surgery time was similar (220 vs 235 min, p=0.705). Cardiopulmonary bypass and myocardial ischemia time was significantly shorter after the AVNeo procedure (108 vs 148 min, p<0.001; 82 vs 115 min, p<0.001, respectively). In-hospital mortality did not differ significantly (3.3% (n=1) and 0, p=0.356). There were no differences in postoperative complications: resternotomy for bleeding (3.3% vs 0, p=1), implantation of permanent pacemaker (0 vs 3.3%, p=0.356), stroke (0 vs 3.3%, p=0.807). Sepsis, AKI and wound superficial infection were not observed in any patient. Three-year overall survival was lower in the AVNeo group (89.4% vs 100%, p=0.015). Three-year freedom from redo surgery was lower in the AVNeo group (79.7% vs 100%, p=0.034). Conclusion. In-hospital mortality and postoperative complications did not differ between groups. Overall 3-year survival and freedom from redo surgery were higher after the Ross procedure.
- 25 April 2025
- Published by Media Sphere Publishing Group in Russian Journal of Cardiology and Cardiovascular Surgery
- Vol. 18 (2)
Immediate and mid-term results of the Ross and Ozaki procedures in adults
Objective. To compare the immediate and mid-term results of the AVNeo and Ross procedures for aortic valve disease in adults. Material and methods. After PSM, we distinguished 2 groups by 30 patients: group I — the AVNeo procedure (n=30), group II (n=30) — the Ross procedure. Inclusion criteria: patients aged ≥16 years who underwent the Ross or AVNeo surgery. There were no exclusion criteria. The median follow-up period was 27 [13; 76] months (24 [17; 32] and 80 [33; 103], respectively). Results. Demographic and preoperative clinical and echocardiographic characteristics after PSM did not differ between groups. Mean age of patients was 48 [37; 59] and 50 [42; 54] years, respectively (p=0.707). Surgery time was similar (220 vs 235 min, p=0.705). Cardiopulmonary bypass and myocardial ischemia time was significantly shorter after the AVNeo procedure (108 vs 148 min, p<0.001; 82 vs 115 min, p<0.001, respectively). In-hospital mortality did not differ significantly (3.3% (n=1) and 0, p=0.356). There were no differences in postoperative complications: resternotomy for bleeding (3.3% vs 0, p=1), implantation of permanent pacemaker (0 vs 3.3%, p=0.356), stroke (0 vs 3.3%, p=0.807). Sepsis, AKI and wound superficial infection were not observed in any patient. Three-year overall survival was lower in the AVNeo group (89.4% vs 100%, p=0.015). Three-year freedom from redo surgery was lower in the AVNeo group (79.7% vs 100%, p=0.034). Conclusion. In-hospital mortality and postoperative complications did not differ between groups. Overall 3-year survival and freedom from redo surgery were higher after the Ross procedure.
- Open Access
- 1 January 2025
- Published by A.V. Vishnevsky National Medical Research Center of Surgery of the Ministry of Healthcare of the Russian Federation in Minimally Invasive Cardiovascular Surgery
- Vol. 1 (4) , 58-67
Experience with the use of the heartstring device for proximal anastomosis in 1,720 patients undergoing off-pump coronary
Цель исследования: оценить непосредственные результаты применения устройства Heartstring при формировании проксимальных анастомозов у пациентов, перенесших изолированное коронарное шунтирование (КШ) на работающем сердце. Материалы и методы: проведён ретроспективный анализ 1720 пациентов, оперированных в период с 2009 г. по 2022 г. Изучались демографические характеристики, интраоперационные данные и непосредственные результаты послеоперационного периода. Все вмешательства выполнены без искусственного кровообращения, с использованием устройства Heartstring для проксимальных анастомозов. Оценивались частота инсульта, периоперационного инфаркта миокарда, осложнений, требующих реэксплорации, а также госпитальная летальность. Результаты: медиана возраста пациентов составила 63 (58–69) лет, мужчин — 88,3%. Атероматоз аорты выявлен у 54,3% больных. Медиана длительность операции составила 155 (135–180) минут, конверсия к искусственному кровообращению потребовалась в 0,6% случаев. Частота периоперационного инфаркта миокарда составила 1%, инсульта — 1,2%, острого почечного повреждения — 1,6%, реэксплорации по поводу кровотечения — 1,6%. Госпитальная летальность составила 0,9%. Использование устройства Heartstring позволило безопасно выполнить проксимальные анастомозы без пережатия аорты даже у пациентов с выраженным атероматозом, обеспечив низкий уровень неврологических и геморрагических осложнений. Заключение: применение устройства Heartstring при КШ на работающем сердце является надёжной и безопасной технологией, позволяющей снизить риск инсульта и других осложнений, связанных с манипуляциями на аорте. Методика может рассматриваться как эффективная альтернатива традиционному способу анастомозирования у пациентов с высоким риском атероэмболии.
- 1 January 2025
- Published by A.V. Vishnevsky National Medical Research Center of Surgery of the Ministry of Healthcare of the Russian Federation in Minimally Invasive Cardiovascular Surgery
- Vol. 1 (4) , 58-67
Open AccessExperience with the use of the heartstring device for proximal anastomosis in 1,720 patients undergoing off-pump coronary
Цель исследования: оценить непосредственные результаты применения устройства Heartstring при формировании проксимальных анастомозов у пациентов, перенесших изолированное коронарное шунтирование (КШ) на работающем сердце. Материалы и методы: проведён ретроспективный анализ 1720 пациентов, оперированных в период с 2009 г. по 2022 г. Изучались демографические характеристики, интраоперационные данные и непосредственные результаты послеоперационного периода. Все вмешательства выполнены без искусственного кровообращения, с использованием устройства Heartstring для проксимальных анастомозов. Оценивались частота инсульта, периоперационного инфаркта миокарда, осложнений, требующих реэксплорации, а также госпитальная летальность. Результаты: медиана возраста пациентов составила 63 (58–69) лет, мужчин — 88,3%. Атероматоз аорты выявлен у 54,3% больных. Медиана длительность операции составила 155 (135–180) минут, конверсия к искусственному кровообращению потребовалась в 0,6% случаев. Частота периоперационного инфаркта миокарда составила 1%, инсульта — 1,2%, острого почечного повреждения — 1,6%, реэксплорации по поводу кровотечения — 1,6%. Госпитальная летальность составила 0,9%. Использование устройства Heartstring позволило безопасно выполнить проксимальные анастомозы без пережатия аорты даже у пациентов с выраженным атероматозом, обеспечив низкий уровень неврологических и геморрагических осложнений. Заключение: применение устройства Heartstring при КШ на работающем сердце является надёжной и безопасной технологией, позволяющей снизить риск инсульта и других осложнений, связанных с манипуляциями на аорте. Методика может рассматриваться как эффективная альтернатива традиционному способу анастомозирования у пациентов с высоким риском атероэмболии.
- Open Access
- 5 December 2024
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 39 (4) , 56-65
Comparison of the results of aortic valve neocuspidalization (Ozaki procedure) with aortic valve bioprosthetics in patients with a narrow aortic annulus: a multicenter retrospective study
In aortic valve (AV) replacement surgery in patients with a narrow annulus fibrosus (AF), the likelihood of prosthesis-patient mismatch (PPM) is high. PPM, in turn, significantly affects the hemodynamic and functional capabilities of AV, morbidity and mortality in the postoperative period. The “gold standard” for the treatment of AV diseases is prosthetics with mechanical and biological prostheses. However, there are alternative methods, such as neocuspidalization of AV according to the S. Ozaki (AVNeo) method.Aim: To compare the immediate and medium-term results of AV prosthetics using the S. Ozaki (AVNeo) technique and AV prosthetics with a biological prosthesis in patients with a small aortic annulus.Material and Methods: A retrospective multicenter study of 309 patients with a narrow fibrous ring of the aortic valve (FR AV) who underwent surgery between February 2010 and December 2021 was conducted. Inclusion criteria: prosthetics of AV, FR AV = 21 mm, age 18 years and older. Exclusion criteria: left ventricle ejection fraction ≤ 40%, repeated interventions, mini-stop. 153 patients underwent Aveo and 156 patients underwent AV prosthetics using biological prostheses. After “pseudorandomization” (propensity score matching), 92 patients were selected: 46 patients in the AVNeo group and 46 patients in the biological prosthesis group. The primary endpoint was hospital mortality. Postoperative complications, transvalvular gradients, and medium-term outcomes (three-year overall survival and freedom from surgery on AV) were evaluated as secondary endpoints.Results. There was no statistically significant difference in the duration of surgery (275.9 ± 34.2 min in the AVNeo group and 285.8 ± 37 min in the bioprosthesis group, p < 0.4), artificial circulation (98 min in the AVNeo group and 115 min in the bioprosthesis group, p < 0.3), aortic compression (80 min in the AVNeo group and 93 min in the bioprosthesis group, p < 0.7). Hospital mortality among the studied patients did not differ: in the AVNeo group – 2 (4.3%) and 1 (2.2%) in the bioprosthesis group, p = 1.0. There were no significant differences in postoperative complications: wound surface infection (3 (6.5%) in the AVNeo group and 1 (2.2%) in the bioprosthesis group, p = 0.617), acute kidney injury (1 (2.2%) in the AVNeo group and 0 in the bioprosthesis group, p = 1.0), stroke ( 1 (2.2%) in the AVNeo group and 2 (4.3%) in the bioprosthesis group, p = 1.0), resternotomy for bleeding (0 in the AVNeo group and 2 (4.3%) in the bioprosthesis group, p = 0.495). Permanent pacemaker implantation was not required by any patient. There was also no statistically significant difference in the three-year overall survival and re–operation, in the AVNeo group it was 83% and 92.5% in the bioprosthesis group, p = 0.23; three-year freedom from re-operation was 96.4% in the AVNeo group and 97.1% in the bioprosthesis group, p = 0.27. However, peak and average gradients were statistically less after AVNeo surgery. The peak and average gradients after AVNeo were 12 and 6 mmHg, after prosthetics 32 and 20 mmHg, p < 0.001.Conclusions: There was no statistically significant difference in hospital mortality, postoperative complications, and three-year survival and re-operation. The values of the peak and average pressure gradient at discharge differed statistically significantly in favor of the AVNeo group.
- 5 December 2024
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 39 (4) , 56-65
Open AccessComparison of the results of aortic valve neocuspidalization (Ozaki procedure) with aortic valve bioprosthetics in patients with a narrow aortic annulus: a multicenter retrospective study
In aortic valve (AV) replacement surgery in patients with a narrow annulus fibrosus (AF), the likelihood of prosthesis-patient mismatch (PPM) is high. PPM, in turn, significantly affects the hemodynamic and functional capabilities of AV, morbidity and mortality in the postoperative period. The “gold standard” for the treatment of AV diseases is prosthetics with mechanical and biological prostheses. However, there are alternative methods, such as neocuspidalization of AV according to the S. Ozaki (AVNeo) method.Aim: To compare the immediate and medium-term results of AV prosthetics using the S. Ozaki (AVNeo) technique and AV prosthetics with a biological prosthesis in patients with a small aortic annulus.Material and Methods: A retrospective multicenter study of 309 patients with a narrow fibrous ring of the aortic valve (FR AV) who underwent surgery between February 2010 and December 2021 was conducted. Inclusion criteria: prosthetics of AV, FR AV = 21 mm, age 18 years and older. Exclusion criteria: left ventricle ejection fraction ≤ 40%, repeated interventions, mini-stop. 153 patients underwent Aveo and 156 patients underwent AV prosthetics using biological prostheses. After “pseudorandomization” (propensity score matching), 92 patients were selected: 46 patients in the AVNeo group and 46 patients in the biological prosthesis group. The primary endpoint was hospital mortality. Postoperative complications, transvalvular gradients, and medium-term outcomes (three-year overall survival and freedom from surgery on AV) were evaluated as secondary endpoints.Results. There was no statistically significant difference in the duration of surgery (275.9 ± 34.2 min in the AVNeo group and 285.8 ± 37 min in the bioprosthesis group, p < 0.4), artificial circulation (98 min in the AVNeo group and 115 min in the bioprosthesis group, p < 0.3), aortic compression (80 min in the AVNeo group and 93 min in the bioprosthesis group, p < 0.7). Hospital mortality among the studied patients did not differ: in the AVNeo group – 2 (4.3%) and 1 (2.2%) in the bioprosthesis group, p = 1.0. There were no significant differences in postoperative complications: wound surface infection (3 (6.5%) in the AVNeo group and 1 (2.2%) in the bioprosthesis group, p = 0.617), acute kidney injury (1 (2.2%) in the AVNeo group and 0 in the bioprosthesis group, p = 1.0), stroke ( 1 (2.2%) in the AVNeo group and 2 (4.3%) in the bioprosthesis group, p = 1.0), resternotomy for bleeding (0 in the AVNeo group and 2 (4.3%) in the bioprosthesis group, p = 0.495). Permanent pacemaker implantation was not required by any patient. There was also no statistically significant difference in the three-year overall survival and re–operation, in the AVNeo group it was 83% and 92.5% in the bioprosthesis group, p = 0.23; three-year freedom from re-operation was 96.4% in the AVNeo group and 97.1% in the bioprosthesis group, p = 0.27. However, peak and average gradients were statistically less after AVNeo surgery. The peak and average gradients after AVNeo were 12 and 6 mmHg, after prosthetics 32 and 20 mmHg, p < 0.001.Conclusions: There was no statistically significant difference in hospital mortality, postoperative complications, and three-year survival and re-operation. The values of the peak and average pressure gradient at discharge differed statistically significantly in favor of the AVNeo group.
- Open Access
- 10 July 2024
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 39 (2) , 94-103
Short-term outcomes of the Tiara bioprosthesis and the Ozaki procedure comparison: a multicenter retrospective study with propensity score analysis
Cardiac surgery research shows that isolated aortic valve (AV) procedures account for 9% of all cardiac surgeries, with a surgery mortality rate of 2.3% and the predominance of bioprosthese use. Despite the widespread use of these methods, there is a high rate of patient-prosthesis mismatch affecting long-term survival. In this context, new technologies are emerging, such as Tiara bioprostheses and Ozaki neocuspidization of AV, but their comparative analysis is currently lacking.Aim: to compare short-term outcomes of the Tiara bioprosthesis implantation and the Ozaki procedure.Methodology and Research Methods. Retrospective analysis of 387 patients who underwent Ozaki procedure or the Tiara bioprosthesis implantation was performed. Inclusion criteria are patient age 18 years or older, Ozaki procedure performed or the Tiara bioprosthesis implantation. Exclusion criteria are use of a mini-access, the presence of infective endocarditis and repeated cardiac surgery. Ultimately, 352 patients were selected. Given the statistically significant differences in clinical and demographic characteristics between the groups, a propensity score matching was used in a 1 : 1 ratio. As a result two balanced groups of 58 patients each were formed.Results. In the group, where the Tiara bioprosthesis was implanted, the average age was 69 ± 5 years. In the group, where the Ozaki procedure was performed, the average age was 68 ± 6 years (p = 0.3). There were 14 men and 44 women in the Tiara group and 21 men and 37 women in the Ozaki group (p = 0.1). The median diameter of the annulus in the Tiara group was 20 (20–22) mm, while in the Ozaki group it was 21 (20–22) mm (p = 0.2). Statistically significant differences were noted in the duration of the surgery, cardiopulmonary bypass and cross-clamp time, which were statistically less in the Tiara group compared to the Ozaki group: surgery duration – 160 (145–199) minutes versus 250 (220–295) minutes (p < 0.001 ), cardiopulmonary bypass time – 72 (60–97) minutes versus 112 (92–133) minutes (p < 0.001), cross-clamp time – 55 (46–70) minutes versus 81 (71–100) minutes (p < 0.001). There was no statistically significant difference between the groups in terms of postoperative complications and hospital mortality. In-hospital mortality was 0% versus 2 (3.4%) cases (p = 0.4). Resternotomy due to bleeding was performed in 1 patient (1.7%) in the Tiara group and in 4 patients (6.9%) in the Ozaki group (p = 0.3). Pacemaker implantation was required in 2 patients (3.4%) in the Tiara group, whereas such a need did not arise in the Ozaki group (p = 0.4). Stroke occurred in 4 patients (6.9%) in the Tiara group and in 1 patient (1.7%) in the Ozaki group (p = 0.3). Acute kidney injury was recorded only in 1 patient in the Ozaki group (1.7%) (p = 1). Both groups had similar rates of patient-prosthesis mismatch; moderate discrepancy was noted in only one patient (1.7%) in the Tiara group; no such cases were recorded in the Ozaki group. However, significant differences were found in peak and mean gradients on AV. In the Tiara group, the peak gradient was 32 ± 12 mmHg, and the average was 17 (11–20) mmHg. In comparison, in the Ozaki group the average values were significantly lower: peak gradient – 11 ± 5 mmHg, average – 5 (3–8) mmHg. (p < 0.001 for both comparisons).Conclusion. The study showed that the surgery duration, cardiopulmonary bypass, and myocardial ischemia period was statistically significantly shorter in the Tiara group compared with the Ozaki group. Despite this, transvalvular gradients on the AV were smaller in the Ozaki group.
- 10 July 2024
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 39 (2) , 94-103
Open AccessShort-term outcomes of the Tiara bioprosthesis and the Ozaki procedure comparison: a multicenter retrospective study with propensity score analysis
Cardiac surgery research shows that isolated aortic valve (AV) procedures account for 9% of all cardiac surgeries, with a surgery mortality rate of 2.3% and the predominance of bioprosthese use. Despite the widespread use of these methods, there is a high rate of patient-prosthesis mismatch affecting long-term survival. In this context, new technologies are emerging, such as Tiara bioprostheses and Ozaki neocuspidization of AV, but their comparative analysis is currently lacking.Aim: to compare short-term outcomes of the Tiara bioprosthesis implantation and the Ozaki procedure.Methodology and Research Methods. Retrospective analysis of 387 patients who underwent Ozaki procedure or the Tiara bioprosthesis implantation was performed. Inclusion criteria are patient age 18 years or older, Ozaki procedure performed or the Tiara bioprosthesis implantation. Exclusion criteria are use of a mini-access, the presence of infective endocarditis and repeated cardiac surgery. Ultimately, 352 patients were selected. Given the statistically significant differences in clinical and demographic characteristics between the groups, a propensity score matching was used in a 1 : 1 ratio. As a result two balanced groups of 58 patients each were formed.Results. In the group, where the Tiara bioprosthesis was implanted, the average age was 69 ± 5 years. In the group, where the Ozaki procedure was performed, the average age was 68 ± 6 years (p = 0.3). There were 14 men and 44 women in the Tiara group and 21 men and 37 women in the Ozaki group (p = 0.1). The median diameter of the annulus in the Tiara group was 20 (20–22) mm, while in the Ozaki group it was 21 (20–22) mm (p = 0.2). Statistically significant differences were noted in the duration of the surgery, cardiopulmonary bypass and cross-clamp time, which were statistically less in the Tiara group compared to the Ozaki group: surgery duration – 160 (145–199) minutes versus 250 (220–295) minutes (p < 0.001 ), cardiopulmonary bypass time – 72 (60–97) minutes versus 112 (92–133) minutes (p < 0.001), cross-clamp time – 55 (46–70) minutes versus 81 (71–100) minutes (p < 0.001). There was no statistically significant difference between the groups in terms of postoperative complications and hospital mortality. In-hospital mortality was 0% versus 2 (3.4%) cases (p = 0.4). Resternotomy due to bleeding was performed in 1 patient (1.7%) in the Tiara group and in 4 patients (6.9%) in the Ozaki group (p = 0.3). Pacemaker implantation was required in 2 patients (3.4%) in the Tiara group, whereas such a need did not arise in the Ozaki group (p = 0.4). Stroke occurred in 4 patients (6.9%) in the Tiara group and in 1 patient (1.7%) in the Ozaki group (p = 0.3). Acute kidney injury was recorded only in 1 patient in the Ozaki group (1.7%) (p = 1). Both groups had similar rates of patient-prosthesis mismatch; moderate discrepancy was noted in only one patient (1.7%) in the Tiara group; no such cases were recorded in the Ozaki group. However, significant differences were found in peak and mean gradients on AV. In the Tiara group, the peak gradient was 32 ± 12 mmHg, and the average was 17 (11–20) mmHg. In comparison, in the Ozaki group the average values were significantly lower: peak gradient – 11 ± 5 mmHg, average – 5 (3–8) mmHg. (p < 0.001 for both comparisons).Conclusion. The study showed that the surgery duration, cardiopulmonary bypass, and myocardial ischemia period was statistically significantly shorter in the Tiara group compared with the Ozaki group. Despite this, transvalvular gradients on the AV were smaller in the Ozaki group.
- Open Access
- 28 April 2024
- Published by Scientific Research Institute - Ochapovsky Regional Clinical Hospital No 1 in Innovative Medicine of Kuban
- No. 2,p. 16-25
Long-term Outcomes of Surgical Correction of Ischemic Mitral Regurgitation
Objective: To evaluate long-term outcomes of mitral valve annuloplasty using an autologous pericardial strip (“soft support ring” type) and a rigid support ring in combination with coronary artery bypass graft (CABG) in patients with ischemic mitral regurgitation.Materials and methods: We carried out retrospective and prospective analyses of the treatment outcomes in 90 patients with coronary heart disease (CHD) and ischemic mitral regurgitation. Ischemic mitral regurgitation (grade 2 or above) was an inclusion criterion for patients with CHD. Exclusion criteria were as follows: nonischemic mitral regurgitation, acute myocardial infarction, progressive angina pectoris, and repeated heart interventions. The patients were divided into 2 groups. Patients from group 1 underwent CABG with mitral regurgitation correction using a strip of glutaraldehyde-treated autologous pericardium (“soft support ring” type) according to our own method, whereas patients from group 2 underwent CABG with mitral regurgitation correction using a rigid support ring. The analysis revealed that the groups were comparable in all the studied parameters.Results: There was no statistically significant difference in the number of postoperative complications and hospital mortality between the groups. According to the analyzed data obtained at the time of discharge, all the patients had grade 0-1 mitral regurgitation, which shows a complete restoration of the mitral valve function after annuloplasty. In addition, there was a statistically significant decrease in the end-diastolic volume and an increase in ejection fraction, which is a sign of reverse left ventricular (LV) remodeling. The mean follow-up was 44±7.4 months. No deaths were reported during the follow-up. The results of the examination in the long-term period did not reveal negative dynamics in most patients compared with the findings in the early postoperative period. The LV size also did not change significantly, and the ejection fraction demonstrated an upward trend. One patient in each group had a recurrence of grade 3 mitral regurgitation.Conclusions: The immediate outcomes showed no recurrence of mitral regurgitation, a low number of intraoperative and postoperative complications, and pronounced reverse LV remodeling. We observed stable results in the long-term follow-up: only one patient in each group had a recurrence of mitral regurgitation. Reverse LV remodeling persisted throughout the follow-up. There were no significant differences between the groups in any parameter, which indicates that the developed annuloplasty method is not inferior to the traditional technique with a rigid support ring.
- 28 April 2024
- Published by Scientific Research Institute - Ochapovsky Regional Clinical Hospital No 1 in Innovative Medicine of Kuban
- No. 2,p. 16-25
Open AccessLong-term Outcomes of Surgical Correction of Ischemic Mitral Regurgitation
Objective: To evaluate long-term outcomes of mitral valve annuloplasty using an autologous pericardial strip (“soft support ring” type) and a rigid support ring in combination with coronary artery bypass graft (CABG) in patients with ischemic mitral regurgitation.Materials and methods: We carried out retrospective and prospective analyses of the treatment outcomes in 90 patients with coronary heart disease (CHD) and ischemic mitral regurgitation. Ischemic mitral regurgitation (grade 2 or above) was an inclusion criterion for patients with CHD. Exclusion criteria were as follows: nonischemic mitral regurgitation, acute myocardial infarction, progressive angina pectoris, and repeated heart interventions. The patients were divided into 2 groups. Patients from group 1 underwent CABG with mitral regurgitation correction using a strip of glutaraldehyde-treated autologous pericardium (“soft support ring” type) according to our own method, whereas patients from group 2 underwent CABG with mitral regurgitation correction using a rigid support ring. The analysis revealed that the groups were comparable in all the studied parameters.Results: There was no statistically significant difference in the number of postoperative complications and hospital mortality between the groups. According to the analyzed data obtained at the time of discharge, all the patients had grade 0-1 mitral regurgitation, which shows a complete restoration of the mitral valve function after annuloplasty. In addition, there was a statistically significant decrease in the end-diastolic volume and an increase in ejection fraction, which is a sign of reverse left ventricular (LV) remodeling. The mean follow-up was 44±7.4 months. No deaths were reported during the follow-up. The results of the examination in the long-term period did not reveal negative dynamics in most patients compared with the findings in the early postoperative period. The LV size also did not change significantly, and the ejection fraction demonstrated an upward trend. One patient in each group had a recurrence of grade 3 mitral regurgitation.Conclusions: The immediate outcomes showed no recurrence of mitral regurgitation, a low number of intraoperative and postoperative complications, and pronounced reverse LV remodeling. We observed stable results in the long-term follow-up: only one patient in each group had a recurrence of mitral regurgitation. Reverse LV remodeling persisted throughout the follow-up. There were no significant differences between the groups in any parameter, which indicates that the developed annuloplasty method is not inferior to the traditional technique with a rigid support ring.