Amina Mohsen Abass
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amina Mohsen Abass has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Omar Salih Hassan
Department of Chemistry, College of Education for Pure Sciences, Tikrit University, Tikrit, Iraq
3 shared publications- Sahar S. M. Alabdullah
Department of Chemistry, College of Science, Al-Nahrain University, Al-Jaderia, Baghdad-Iraq
3 shared publications - Ahmed Ahmed
Department of Chemistry, College of Science, Al-Nahrain University, Al-Jaderia, Baghdad-Iraq
2 shared publications Ahmed Ahmed
Department of Chemistry, College of Science, Al-Nahrain University. Baghdad, Al-Jaderia ,Iraq
1 shared publicationChemistry Science
1 shared publicationHaider Th.Salim AL Rikabi
Department of Electrical Engineering, College of Engineering ,Wasit University , Wasit, Iraq
1 shared publication
Latest Publications
- Open Access
- 20 April 2023
- Published by College of Science for Women, University of Baghdad in Baghdad Science Journal
- Vol. 20 (5) , 2234-2240
Fabrication of PVC Enrofloxacin-Selective Electrodes for Estimating Enrofloxacin in Pure Form and as Preparation Formula
This study explored the development and qualities of the response of electrochemical properties of enrofloxacin-selective electrodes using precipitation based on producing phosphotungstic, after utilizing a matrix of polyvinyl chloride (PVC) and dibutyl phthalate or dibutyl phosphate as a plasticizer. The resulting membrane sensors were an enrofloxacin-phosphotungstic electrode (sensors 1) and an ENR-DOP-PTA electrode (sensors 2). Linear responses of (ENR-DBPH-PTA) and (ENR-DOP-PTA) within the concentration ranges of 2.1×10-6-10-1 and 3.0×10-6-10-2 mol. L-1, respectively, for both sensors were observed. Slopes of 51.61±0.24 and 39.40± 0.16 mV/decade and pH ranges equal to 2.5-8.5 and 2.0-9.0 were observed for sensors 1 and 2, respectively. The coefficients of selectivity of the created sensors demonstrated phenomenal selectivity for ENR. The proposed sensors showed useful scientific properties for the assurance of ENR in drug dosage and pure form.
- 20 April 2023
- Published by College of Science for Women, University of Baghdad in Baghdad Science Journal
- Vol. 20 (5) , 2234-2240
Open AccessFabrication of PVC Enrofloxacin-Selective Electrodes for Estimating Enrofloxacin in Pure Form and as Preparation Formula
This study explored the development and qualities of the response of electrochemical properties of enrofloxacin-selective electrodes using precipitation based on producing phosphotungstic, after utilizing a matrix of polyvinyl chloride (PVC) and dibutyl phthalate or dibutyl phosphate as a plasticizer. The resulting membrane sensors were an enrofloxacin-phosphotungstic electrode (sensors 1) and an ENR-DOP-PTA electrode (sensors 2). Linear responses of (ENR-DBPH-PTA) and (ENR-DOP-PTA) within the concentration ranges of 2.1×10-6-10-1 and 3.0×10-6-10-2 mol. L-1, respectively, for both sensors were observed. Slopes of 51.61±0.24 and 39.40± 0.16 mV/decade and pH ranges equal to 2.5-8.5 and 2.0-9.0 were observed for sensors 1 and 2, respectively. The coefficients of selectivity of the created sensors demonstrated phenomenal selectivity for ENR. The proposed sensors showed useful scientific properties for the assurance of ENR in drug dosage and pure form.
- Open Access
- 7 June 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (6) , 216
Deep Eutectic Solvents Enhance Stability of Ag/AgCl Solid State Miniaturised Reference Electrode
A new class of solid-state miniaturised reference electrodes with a deep eutectic solvent as an alternate enhancement electrode system is described. A simple and accurate stable electrochemical sensor was prepared by developing a conventional reference electrode using an Ag/AgCl planar micro-reference electrode covered with a PVC polymer. A conductive deep eutectic solvent (DES), ethaline, was added in small quantities and mixed with an internal electrolyte to maintain the Cl− ion concentration in the constructed electrode. The fabricated microelectrode showed good stability, reproducibility, and long-term stability against varying concentrations of different ions. The potential response of the fabricated microelectrode was studied under varying concentrations of Cl− ions in the presence of 0.1 to 1.0% DES in a concentrated electrolyte system (20 mM Na2SO4). The stability of the fabricated microelectrode was addressed against Br− and Cl− ions using different inorganic salts, and the potential measurements were found to be insensitive toward all responsive ions. The stability response of the fabricated microelectrode against Cl− ions was optimised in the presence of 1.0% DES. The experimental data showed good agreement with the potential change of the fabricated electrode in the presence of the supporting DES electrolyte. The liquid junction-free PVC solid-state miniaturised reference electrode demonstrated a constant potentiometric measurement over a long period of time. The concentrated supporting DES electrolyte solution (20 mM) exhibited better stability values and was a more suitable fabricated microelectrode than other additive concentrations. The long-term stability of the developed microelectrode displayed a good lifetime and high stability of around 60 days.
- 7 June 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (6) , 216
Open AccessDeep Eutectic Solvents Enhance Stability of Ag/AgCl Solid State Miniaturised Reference Electrode
A new class of solid-state miniaturised reference electrodes with a deep eutectic solvent as an alternate enhancement electrode system is described. A simple and accurate stable electrochemical sensor was prepared by developing a conventional reference electrode using an Ag/AgCl planar micro-reference electrode covered with a PVC polymer. A conductive deep eutectic solvent (DES), ethaline, was added in small quantities and mixed with an internal electrolyte to maintain the Cl− ion concentration in the constructed electrode. The fabricated microelectrode showed good stability, reproducibility, and long-term stability against varying concentrations of different ions. The potential response of the fabricated microelectrode was studied under varying concentrations of Cl− ions in the presence of 0.1 to 1.0% DES in a concentrated electrolyte system (20 mM Na2SO4). The stability of the fabricated microelectrode was addressed against Br− and Cl− ions using different inorganic salts, and the potential measurements were found to be insensitive toward all responsive ions. The stability response of the fabricated microelectrode against Cl− ions was optimised in the presence of 1.0% DES. The experimental data showed good agreement with the potential change of the fabricated electrode in the presence of the supporting DES electrolyte. The liquid junction-free PVC solid-state miniaturised reference electrode demonstrated a constant potentiometric measurement over a long period of time. The concentrated supporting DES electrolyte solution (20 mM) exhibited better stability values and was a more suitable fabricated microelectrode than other additive concentrations. The long-term stability of the developed microelectrode displayed a good lifetime and high stability of around 60 days.
- Open Access
- 27 October 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (55) , 34820-34827
Novel potentiometric sensors for determination of ondansetron hydrochloride in pure and dosage form
A new and sensitive potentiometric method has been developed and characterized for four novel sensors responsive to ondansetron hydrochloride. The potentiometric sensor method includes advancement of ondansetron hydrochloride sensors using a membrane comprised of molybdophosphoric acid (MPA) and ondansetron as an electro-active material in a polyvinylchloride (PVC) matrix membrane plasticized with di-butyl phthalate (DBPH), ortho-nitrophenyloctyl ether (O-NPOE), di-octyl phthalate (DOPH), or di-butyl phosphate (DBP). The validity of sensors in the present work has been examined, and steady and reproducible responses were obtained over the concentration ranges of 7.3 × 10−5 to 1.0 × 10−2, 6.6 × 10−6 to 1.0 × 10−2, 1.0 × 10−5 to 1.0 × 10−2, and 2.0 × 10−5 to 1.0 × 10−2 M for DBPH-, O-NPOE-, DOPH-, and DBP-ondansetron, respectively. The sensors revealed Nernstian gradients of 59.61 ± 0.50, 57.71 ± 0.23, 53.01 ± 0.14, and 53.20 ± 0.35 mV per decade individually with pH ranges of 2.5–5.5 in DBPH and 3.5–5.0 in O-NPOE electrodes, and 4.0–5.5 for both individual DOPH and DBP plasticized film-based sensors. The time responses for the sensors were 30, 32, 31, and 29 s for DBPH-, O-NPOE-, DOPH-, and DBP-ondansetron, respectively. The developed sensors also exhibited high selectivity towards ondansetron hydrochloride against different interfering species of inorganic particles with long-term stability of approximately 41, 36, 18, and multiple days for the DBPH, O-NPOE, DOPH, and DBP electrodes.
- 27 October 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (55) , 34820-34827
Open AccessNovel potentiometric sensors for determination of ondansetron hydrochloride in pure and dosage form
A new and sensitive potentiometric method has been developed and characterized for four novel sensors responsive to ondansetron hydrochloride. The potentiometric sensor method includes advancement of ondansetron hydrochloride sensors using a membrane comprised of molybdophosphoric acid (MPA) and ondansetron as an electro-active material in a polyvinylchloride (PVC) matrix membrane plasticized with di-butyl phthalate (DBPH), ortho-nitrophenyloctyl ether (O-NPOE), di-octyl phthalate (DOPH), or di-butyl phosphate (DBP). The validity of sensors in the present work has been examined, and steady and reproducible responses were obtained over the concentration ranges of 7.3 × 10−5 to 1.0 × 10−2, 6.6 × 10−6 to 1.0 × 10−2, 1.0 × 10−5 to 1.0 × 10−2, and 2.0 × 10−5 to 1.0 × 10−2 M for DBPH-, O-NPOE-, DOPH-, and DBP-ondansetron, respectively. The sensors revealed Nernstian gradients of 59.61 ± 0.50, 57.71 ± 0.23, 53.01 ± 0.14, and 53.20 ± 0.35 mV per decade individually with pH ranges of 2.5–5.5 in DBPH and 3.5–5.0 in O-NPOE electrodes, and 4.0–5.5 for both individual DOPH and DBP plasticized film-based sensors. The time responses for the sensors were 30, 32, 31, and 29 s for DBPH-, O-NPOE-, DOPH-, and DBP-ondansetron, respectively. The developed sensors also exhibited high selectivity towards ondansetron hydrochloride against different interfering species of inorganic particles with long-term stability of approximately 41, 36, 18, and multiple days for the DBPH, O-NPOE, DOPH, and DBP electrodes.
- 9 June 2021
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 64 (11) , 6293-6300
Potentiometric Determination Of Fexofenadine Hydrochloride Drug By Fabrication Of Liquid Membrane Electrodes
This paper presents a study in the electrochemical methods for the preparation three new electrodes of Fexofenadine hydrochloride in a polymeric membrane. The first electrode was prepared from ion pair: molybdophosphoric acid reagent and fexofenadine cation with Di-n-butyl phthalate (DBPH), the subsequent electrode was prepared with O-Nitro phenyl octyl ether( NPOE) and the third electrode was set up by Tri-n-butyl phthalate (TBP), respectively as a plasticizers for determination of Fexofenadine hydrochloride drug. Two electrodes indicated a Nernstian response with a slope of [57.01, 56.70] mV.decade−1 for the first and second electrodes individually, with detection limits 5.6×10-6 mole.L-1 for first electrode and 3.5×10-6 mole.L-1 for second electrode and the third electrode was gave a non Nernstain response equivalent to 14.30 mV.decade−1. The electrodes work adequately over pH range (2.0-4.5),(2.5-4.0) and (2.0- 4.0) for Fexofenadine hydrochloride electrodes. The impact of interfering species was insignificant as demonstrated by selectivity coefficient values. The viability of the electrodes proceeded in a timeframe (41,36,and 13) days. The recommended electrodes were successfully used for the determination of Fexofenadine hydrochloride in pure form and pharmaceuticals preparations. This work arrived at excellent outcomes as far as the linearity, exactness, selectivity, and accuracy of the methods.
- 9 June 2021
- Published by Egyptian Knowledge Bank in Egyptian Journal of Chemistry
- Vol. 64 (11) , 6293-6300
Potentiometric Determination Of Fexofenadine Hydrochloride Drug By Fabrication Of Liquid Membrane Electrodes
This paper presents a study in the electrochemical methods for the preparation three new electrodes of Fexofenadine hydrochloride in a polymeric membrane. The first electrode was prepared from ion pair: molybdophosphoric acid reagent and fexofenadine cation with Di-n-butyl phthalate (DBPH), the subsequent electrode was prepared with O-Nitro phenyl octyl ether( NPOE) and the third electrode was set up by Tri-n-butyl phthalate (TBP), respectively as a plasticizers for determination of Fexofenadine hydrochloride drug. Two electrodes indicated a Nernstian response with a slope of [57.01, 56.70] mV.decade−1 for the first and second electrodes individually, with detection limits 5.6×10-6 mole.L-1 for first electrode and 3.5×10-6 mole.L-1 for second electrode and the third electrode was gave a non Nernstain response equivalent to 14.30 mV.decade−1. The electrodes work adequately over pH range (2.0-4.5),(2.5-4.0) and (2.0- 4.0) for Fexofenadine hydrochloride electrodes. The impact of interfering species was insignificant as demonstrated by selectivity coefficient values. The viability of the electrodes proceeded in a timeframe (41,36,and 13) days. The recommended electrodes were successfully used for the determination of Fexofenadine hydrochloride in pure form and pharmaceuticals preparations. This work arrived at excellent outcomes as far as the linearity, exactness, selectivity, and accuracy of the methods.