  • A Single-Phase Grid-Tied Transformer-Less Multilevel Solar Inverter With Voltage Boost

    by Soham Chakraborty, Koustuv Sarkar, Dipten Maiti, Abanishwar Chakrabarti, Sukanya Dasgupta, Sujit K. Biswas

    This work proposes a single-phase multilevel grid-tied transformer-less solar inverter with voltage boost. The system comprises of two cascaded stages: the first is a partially rated dc–dc boost converter to create four dc voltage levels, while the second is a new topology of single-phase multilevel sinusoidal pulse width modulated (SPWM) inverter at rated volt-ampere (VA) coupled to the dc–dc converter output voltage levels. This scheme does not require capacitor voltage balancing due to the floating dc supply created in the dc–dc conversion stage. The inverter is controlled using a multicarrier SPWM logic. This scheme exhibits near sinusoidal line current, hence offering reduced filter requirements and reduced common mode currents during grid integration. The device losses in this scheme are low compared to the existing schemes, thus reducing heat-sink requirements. The voltage boost capability becomes cost-effective due to the partial rated conversion stage that offers seamless integration of the inverter at the grid voltage without any additional coupling transformer. Simulation and experimental study confirm the effectiveness of the proposed scheme in applications of single-phase grid interfaced harnessing of solar photovoltaic energy and injecting the power to the utility network.


  • Smart Hybrid Energy Management System for Green Microgrid With Optimized Energy and Enhanced Voltage Stability

    by Soham Chakraborty, Pavan Mehta, Pallavi Bharadwaj

    Energy management systems (EMSs) are an integral part of power networks with distributed energy resources (DERs) for optimized energy transactions. Conventional EMS performs rule-based actions for energy transactions between the DERs without considering optimization of resource and network stability. This paper proposes a smart hybrid EMS for an AC microgrid with optimal energy transactions with the utility distribution grid for improved cost-benefits along with stabilizing the voltage levels at the point of common coupling (PCC) using VAr compensation. The proposed EMS incorporates a hybrid scheme of rule based prioritization combined with an optimization module for energy management based on forecasted data of AC microgrid under grid-connected and islanded conditions. This reduces the operational cost of energy by at least 20% compared to classical EMS through a systematic cost-benefit analysis of microgrid. Besides, it aims at reduction of carbon emissions by at least 30% compared to classical EMS by prioritizing renewable energy sources and optimizing energy transfers. The proposed EMS not only ensures the active power management of a photovoltaic (PV) source, a battery energy storage system (BESS) and a diesel generator under different operating conditions but also performs VAr compensation using the grid-tied converters of PV and BESS which are dynamically limited by the EMS depending on the rated VA of the respective entities and the real-time active power injected. The simulation results from MATLAB/SIMULINK, analysis along with validation using the laboratory grid-tied converter prototype with PV source and battery setups establish the effectiveness of the proposed smart EMS.


  • Optimized design coordination of a single phase static VAr compensator for AC railway traction

    by Soham Chakraborty, Dipten Maiti, Susovan Mukhopadhyay, Abanishwar Chakrabarti, Sujit K. Biswas


  • Negative Sequence Current Injection Based Active Islanding Detection Method

    by Chiranjit Biswas, Soham Chakraborty, Kamakshi Patro, Jyotsna Nain, Abanishwar Chakrabarti, Rakesh Roy, Bikram Das, Prabir R. Kasari, Swanirbhar Majumder, Joyashree Das, et al.

    This article presents a fast and accurate active islanding detection scheme for a grid-tied voltage source inverter (VSI). In the proposed scheme, the VSI generates a small negative sequence voltage to continuously inject a small negative sequence current into the system. The voltage at the point of common coupling (PCC) is measured and the negative sequence component of PCC voltage is extracted. The negative sequence voltage generated by the VSI and the negative sequence voltage at PCC are combined to yield a time-invariant coefficient, which is proposed here to be used for islanding detection. In case detection is done solely based on the magnitude of negative sequence voltage at PCC, higher threshold has to be set as a small magnitude of negative sequence voltage at PCC may also be present due to grid unbalance and other transient events. In the proposed scheme, the islanding detection coefficient depends on the similarity between the injected and measured negative sequence voltage and hence is not dependent on the absolute magnitude of the negative sequence voltage. Thus a very low magnitude of negative sequence current can be injected to effectively detect islanding conditions without a significant impact on power quality. Simulation results show that the proposed scheme is effective for unbalanced grid voltage, or unbalanced load, even in the presence of noise in acquired data. Experimental studies on a laboratory prototype validate the performance of the proposed islanding detection scheme.


  • A Rotor-Tied DFIG Scheme With One Phase Open Circuit Fault-Tolerant Capability

    by Soham Chakraborty, Abanishwar Chakrabarti, Dipten Maiti, Susovan Mukhopadhyay, Sujit K. Biswas

    This article proposes a fault-tolerant control scheme for a transformer isolated three-phase rotor-tied doubly fed induction generator (RT-DFIG) suitable for grid connected wind energy conversion system (WECS). The scheme uses back-to-back connected three-phase four-wire two-level converters having a common dc bus with the grid side converter (GSC) connected to the point of common coupling via a delta/star/star isolation transformer whose neutral is joined to the dc bus midpoint. The stator side converter (SSC) is coupled to the star connected stator terminals of the RT-DFIG with the stator neutral joined to the dc bus midpoint. The rotor is connected directly to the grid via the other star winding of the isolation transformer. This fault-tolerant topology along with the control scheme restrict negative sequence current and allows circulation of zero sequence current through the neutral wire via the dc bus midpoint. This enables seamless operation with time-invariant power transfer and balanced grid side line currents during one-phase open-circuit fault in either the GSC or SSC or one phase of transformer secondary or line reactors or one phase of RT-DFIG stator. This proposed scheme uses a simple control without any extra hardware and hence is cost-effective. Simulation and experimental results are provided to validate the proposed concept.


  • Fault-Tolerant Control of Active Power Filter With Balanced Three-Phase Line Currents

    by Soham Chakraborty, Dipten Maiti, Abanishwar Chakrabarti, Sujit K. Biswas

    Transformer isolated three-phase three-wire two-level active power filters (APF) using pulse width modulated (PWM) control are widely used for shunt compensation of harmonic currents. In a situation when only two of the converter legs remain connected to the grid due to an open circuit fault in one of the converter legs or its internal lines or in one of its line reactors, the existing fault-tolerant schemes cannot continue operation with balanced grid side line currents, resulting in improper harmonic compensation. A new control scheme is proposed in this article by which APF can seamlessly continue fault-tolerant operation during single line open-circuit fault and inject balanced three-phase harmonic currents into the line for proper compensation, without requiring any redundant legs or switches to change the internal power configuration. Unlike conventional APF schemes, a simple control scheme is proposed to adjust the phase shift between the composite harmonic currents in the two operative legs of the converter connected to the grid via a full rated delta/star isolation transformer (or an existing delta-star distribution transformer) with neutral connected to dc bus midpoint to inject balanced harmonic currents into the grid. Simulation and experimental results are provided to validate the effectiveness of proposed concept.


  • Optimal Placement of PV-DSTATCOM Based EV Charging Stations With Dynamic Pricing

    by Soham Chakraborty, Susovan Mukhopadhyay, Sujit K Biswas

    This paper proposes incorporation of a method for optimal sizing and placement of a PV-DSTATCOM (a D-STATCOM feeding active power through the dc link from a PV array) combined with an electric vehicle charging station (EVCS) in a radial distribution system. This device can inject active power from DC side and also compensate var on AC side to maintain voltage stability of the network. The DC side of the PV-DSTATCOM is also utilized for an EVCS, drawing power from PV source or the distribution grid based on PV availability and demand at a given time. The point of common coupling (PCC) of the PV-DSTATCOM is determined by the proposed method for IEEE-38 bus system. It uses modal analysis with sensitivity indices to assess the voltage stability and find critical buses where PV-DSTATCOMs can be placed to improve the overall network stability. The method also combines particle swarm optimization (PSO) for optimal sizing of the PV-DSTATCOM with EVCS provision. In addition, this work proposes a dynamic pricing scheme using an adaptively trained artificial neural network (ANN) for EVCSs to effectively manage demands during peak hours (thereby improving network stability) and benefit EV users in terms of charge per kWh of electricity depending upon the present state of charge (SOC) of their vehicle battery and the level of congestion at EVCS. The results obtained show that the proposed scheme improves voltage stability and reduce line loss of the radial distribution system.


  • Transformer Isolated Fault Tolerant Three Phase Active Front End Converter for EV Charging

    by Soham Chakraborty, Abanishwar Chakrabarti, Dipten Maiti, Sujit K. Biswas

    An Electric Vehicle (EV) charging scheme is proposed using a transformer isolated 3-phase 4-wire two level pulse width modulated fault-tolerant active front end converter (AFEC) followed by DC-DC converters for charge control. The AFEC is controlled to exhibit fault tolerant operation with balanced 3-phase supply line currents at unity displacement factor (DF) in the event of zero current in one line of the converter. While existing fault-tolerant schemes incorporate additional hardware switchover in the form of the redundant leg for the open circuit fault of one phase, the proposed scheme can maintain balanced supply line current at unity DF using a modified control scheme without any additional hardware during an open circuit failure of either a leg of AFEC, line reactor, connecting cable or one secondary phase of transformer. The proposed scheme uses a method of re-adjusting the phase positions of the converter controlled line currents using the Delta(Δ)-Star(Y) isolation transformer. The scheme can be conveniently used to enhance fault tolerant capability of EV charging stations. Simulation and experimental results validate the effectiveness of the proposed scheme.


  • Phase-Controlled Multibank Resistive Heating With Optimized Current Harmonics

    by Susovan Mukhopadhyay, Dipten Maiti, Soham Chakraborty, Sujit K. Biswas

    This article proposes a silicon-controlled rectifier (SCR) phase-controlled 3-phase 3-wire industrial heating system using multiple Delta Banks of resistors. In the proposed scheme, out of two similar groups denoted as “Set,” each has two resistance banks with a finite ratio of maximum power dissipation between them and operating with the same controlled firing angle. Each bank of resistance is “Delta” connected, one with SCRs in phase while the other with SCRs in line. This proposed configuration eliminates triplen besides some major characteristic harmonics in the line current. “Delta” connection permits the use of the same voltage rating of all resistors. In the proposed scheme, two such Sets are operated with a fixed firing angle difference to substantially reduce residual harmonics without any additional filters. An offline-optimization process determines the operating conditions of the sets. The proposed scheme with simple construction and operation, wide power range, and low total harmonic distortion makes it a practical and cost-effective solution. The modeling, analysis, and performance of the proposed scheme are presented, with supporting simulation and experimental results.